Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19318A556 + (ML19318A556)
- ML19318A557 + (ML19318A557)
- ML19318A558 + (ML19318A558)
- 05000348/LER-1980-033-03, /03L-0:on 800516,1-2A Diesel Generator Declared Inoperable Due to Speed Control Failure.Caused by Personnel Error in Installing Dc Recorder Which Blew Ac Fuse.Fuse Replaced,Personnel Instructed + (ML19318A560)
- ML19318A561 + (ML19318A561)
- ML19318A562 + (ML19318A562)
- ML19318A563 + (ML19318A563)
- ML19318A564 + (ML19318A564)
- IR 05000369/1980007 + (ML19318A565)
- ML19318A566 + (ML19318A566)
- ML19318A567 + (ML19318A567)
- 05000348/LER-1980-032-03, /03L-0:on 800515,both Chlorine Detectors Were Inoperable.Caused by Plastic Strip Lodged in B Detector & Cracked Diaphragm in a Detector.Strip Removed & B Made Operable on 800515.Pump Replaced & a Operable on 800516 + (ML19318A569)
- ML19318A570 + (ML19318A570)
- ML19318A571 + (ML19318A571)
- ML19318A572 + (ML19318A572)
- ML19318A573 + (ML19318A573)
- ML19318A574 + (ML19318A574)
- ML19318A575 + (ML19318A575)
- ML19318A576 + (ML19318A576)
- ML19318A577 + (ML19318A577)
- ML19318A578 + (ML19318A578)
- 05000254/LER-1980-015, Forwards LER 80-015/03L-0 + (ML19318A579)
- ML19318A580 + (ML19318A580)
- 05000254/LER-1980-015-03, /03L-0:on 800511,during Manual Operation of Relief Valves,Valve 1-203-3B Failed to Open.Hpci & Other Valves Operable.Caused by Dirty Contact on Valve Operator hold-in Coil Switch.Switch Replaced & Valve Returned to Svc 80051 + (ML19318A581)
- ML19318A582 + (ML19318A582)
- ML19318A583 + (ML19318A583)
- ML19318A584 + (ML19318A584)
- ML19318A585 + (ML19318A585)
- ML19318A586 + (ML19318A586)
- 05000339/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19318A587)
- ML19318A588 + (ML19318A588)
- 05000339/LER-1980-013-03, /03L-0:on 800520 & 27,w/unit in Hot Standby, Samples of Boron Injection Tank & C Boric Acid Storage Found to Contain Less than 20,000 Ppm Boron.Caused by Leaks Past Inlet Valves MOV-2867 a & B.Switch Settings Increased + (ML19318A589)
- ML19318A590 + (ML19318A590)
- ML19318A591 + (ML19318A591)
- ML19318A592 + (ML19318A592)
- ML19318A593 + (ML19318A593)
- ML19318A594 + (ML19318A594)
- ML19318A596 + (ML19318A596)
- ML19318A597 + (ML19318A597)
- ML19318A599 + (ML19318A599)
- 05000339/LER-1980-020, Forwards LER 80-020/03L-0 + (ML19318A600)
- ML19318A601 + (ML19318A601)
- ML19318A602 + (ML19318A602)
- ML19318A603 + (ML19318A603)
- 05000339/LER-1980-020-03, /03L-0:on 800529,during Mode 3 condition,72-h Periodic Test of Containment Personnel Hatch Was Not Accomplished Due to Failure of Doors to Close.Caused by Failure of Limit Switch on Inner Door.Switch Replaced + (ML19318A604)
- ML19318A606 + (ML19318A606)
- ML19318A607 + (ML19318A607)
- IR 05000309/1980002 + (ML19318A608)
- ML19318A609 + (ML19318A609)
- ML19318A610 + (ML19318A610)
- ML19318A613 + (ML19318A613)