- GO2-87-278, Application for Amend to License NPF-21,modifying Snubber Functional Testing Sampling Plans,Per Guidelines of Draft Ansi/Asme - OM-4 Document, Exam & Performance Testing of Nuclear Power Plant Dynamic Restraints. Fee Paid + (ML17279A658)
- ML17279A659 + (ML17279A659)
- ML17279A660 + (ML17279A660)
- ML17279A662 + (ML17279A662)
- ML17279A665 + (ML17279A665)
- ML17279A666 + (ML17279A666)
- ML17279A672 + (ML17279A672)
- ML17279A675 + (ML17279A675)
- ML17279A676 + (ML17279A676)
- ML17279A679 + (ML17279A679)
- ML17279A680 + (ML17279A680)
- ML17279A681 + (ML17279A681)
- ML17279A682 + (ML17279A682)
- GO2-86-367, Provides Supplemental Info Re 860226 Reload Summary Rept Concerning Changes in Expected Cycle 2 Reload Batch.Meeting Requested to Address NRC Concerns w/860520 Restart Date + (ML17279A692)
- ML17279A693 + (ML17279A693)
- ML17279A694 + (ML17279A694)
- ML17279A696 + (ML17279A696)
- ML17279A700 + (ML17279A700)
- ML17279A702 + (ML17279A702)
- ML17279A708 + (ML17279A708)
- IR 05000397/1987029 + (ML17279A710)
- 05000397/LER-1987-030, :on 871106,upgraded Plant Tech Spec Fire Wall Not Constructed to Qualify as 3 H Fire Barrier & Wall Penetration Not Sealed.Cause Unknown.Engineering Evaluation of Wall & Penetration Will Be Conducted + (ML17279A714)
- RC-17-0107, (Vcsns), Unit 1 - Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change + (ML17279A715)
- ML17279A718 + (ML17279A718)
- ML17279A720 + (ML17279A720)
- ML17279A724 + (ML17279A724)
- IR 05000397/1987028 + (ML17279A726)
- GO2-87-282, Forwards Feedwater Nozzle Insp Rept for Refueling Outage RF87A,Spring 1987, Per NUREG-0619 Requirements + (ML17279A727)
- ML17279A728 + (ML17279A728)
- ML17279A730 + (ML17279A730)
- ML17279A732 + (ML17279A732)
- ML17279A734 + (ML17279A734)
- ML17279A735 + (ML17279A735)
- ML17279A740 + (ML17279A740)
- ML17279A742 + (ML17279A742)
- GO2-87-290, Forwards Final Response to IE Bulletin 85-003 Per .Responses to Items a Through E Have Been Changed to Reflect Addition of & Uses of Movats,Inc Test Equipment + (ML17279A743)
- GO2-87-288, Requests Extension to Required Response Time to 880205 for Responding to Violations Noted in Insp Rept 50-397/87-19,per 871216 Telcon + (ML17279A744)
- GO2-87-289, Responds to Violation Noted in Insp Rept 50-397/86-25 Re Failure to Follow Procedures That Implemented Fire Protection Program.Special fire-rated Window Will Be Installed in Shift Manager Ofc by 880430 + (ML17279A747)
- ML17279A750 + (ML17279A750)
- ML17279A752 + (ML17279A752)
- ML17279A753 + (ML17279A753)
- GO2-87-292, Summarizes Util Concerns Re Accuracy of HVAC Flow Data That Will Become Part of Nureg/Cr on Control Room Habitability + (ML17279A754)
- GO2-87-028, Informs of Plans to Fund plant-specific Study of Sampling Sys in Spring 1989 to Evaluate Position on Iodine Plate Out + (ML17279A762)
- GO2-87-294, Responds to NRC Re Violations Noted in Insp Rept 50-397/87-27.Corrective Actions:Overtime Control Directive Rev & Other Plant Procedures Review & Rev Planned.Full Compliance Expected by 880229 + (ML17279A763)
- ML17279A764 + (ML17279A764)
- GO2-88-001, Requests Removal of Notes Added to Pages 3/4 3-71 & 3/4 3-74 in Amend 47 to License NPF-21.During Outage,Begun on 871206, Util Repaired Acoustical Monitor.Changes Granted on Emergency Basis by Amend No Longer Necessary + (ML17279A766)
- ML17279A767 + (ML17279A767)
- GO2-87-293, Application for Amend to License NPF-21 to Implement Requirements of Rev 2 to Reg Guide 1.97 for Flux Monitoring Prior to Startup Following Fourth Refueling Outage.Fee Paid + (ML17279A768)
- GO2-88-002, Application for Amend to License NPF-21,annotating Encl Table 3.3.2-1 to Reflect Transfer of RHR V-8 to Alternative Remote Shutdown Panel During Normal Operation & Clarifying Action a.2 on Encl Table 3.6.3-1.Fee Paid + (ML17279A769)
- ML17279A770 + (ML17279A770)