Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
PNO-II-99-045, on 991018,Hurricane Irene Was Located Approx 105 Miles East of Cape Hatteras,Nc.Ctr of Hurricane Was Estimated Near Latitude 35.6 North & Longitude 73.8 West. Storm Was Moving Northeast at 35 Mph | 18 October 1999 | PNO-II-99-045:on 991018,Hurricane Irene Was Located Approx 105 Miles East of Cape Hatteras,Nc.Ctr of Hurricane Was Estimated Near Latitude 35.6 North & Longitude 73.8 West. Storm Was Moving Northeast at 35 Mph | |
IR 05000335/1999011 | 8 October 1999 | Partially Deleted Insp Repts 50-335/99-11 & 50-389/99-11 on 990827 & 990907-08 (Ref 10CFR73.21).No Violations Noted. Major Areas Inspected:Plant Support Re Physical Security Program for Power Reactors | |
IR 05000321/1999009 | 7 October 1999 | Insp Repts 50-321/99-09 & 50-366/99-09 on 990607-11 & 0823- 27.One Violation Being Treated as Ncv.Major Areas Inspected: Maint & Engineering | Safe Shutdown Power Uprate |
IR 05000324/1999006 | 6 October 1999 | Insp Repts 50-324/99-06 & 50-325/99-06 on 990801-0911.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support | Locked High Radiation Area Siren |
IR 05000321/1999005 | 16 September 1999 | Insp Repts 50-321/99-05 & 50-366/99-05 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | High Radiation Area Locked High Radiation Area |
PNO-II-99-037D, on 990915,Hurricane Floyd Was Located Approx 380 Miles Southeast of Wilmington,Nc.Ctr of Hurricane Was Estimated Near Latitude 28.8 North & Longitude 78.8 West. Storm Was Moving Northwest at 14 Mph.Max Winds Were 140 Mph | 15 September 1999 | PNO-II-99-037D:on 990915,Hurricane Floyd Was Located Approx 380 Miles Southeast of Wilmington,Nc.Ctr of Hurricane Was Estimated Near Latitude 28.8 North & Longitude 78.8 West. Storm Was Moving Northwest at 14 Mph.Max Winds Were 140 Mph | Siren |
PNO-II-99-037E, on 990915,Hurricane Floyd Was Located Approx 380 Miles Southeast of Wilmington,Nc.Ctr of Hurricane Was Estimated Near Latitude 29.3 North & Longitude 78.8 West. Storm Was Moving north-northwest at 14 Mph | 15 September 1999 | PNO-II-99-037E:on 990915,Hurricane Floyd Was Located Approx 380 Miles Southeast of Wilmington,Nc.Ctr of Hurricane Was Estimated Near Latitude 29.3 North & Longitude 78.8 West. Storm Was Moving north-northwest at 14 Mph | |
PNO-II-99-037F, on 990915,Hurricane Floyd Was Located Approx 350 Miles Southeast of Wilmington,Nc.Ctr of Hurricane Was Estimated Near Latitude 29.9 North & Longitude 79.0 West. Storm Was Moving north-northwest at 14 Mph | 15 September 1999 | PNO-II-99-037F:on 990915,Hurricane Floyd Was Located Approx 350 Miles Southeast of Wilmington,Nc.Ctr of Hurricane Was Estimated Near Latitude 29.9 North & Longitude 79.0 West. Storm Was Moving north-northwest at 14 Mph | |
PNO-II-99-037G, on 990915,Hurricane Floyd Was Located Approx 216 Miles Southeast of Bsep.Ctr of Hurricane Was Estimated Near Latitude 30.6 North & Longitude 79.1 West.Storm Was Moving north-northwest at 14 Mph with Max Winds at 125 Mph | 15 September 1999 | PNO-II-99-037G:on 990915,Hurricane Floyd Was Located Approx 216 Miles Southeast of Bsep.Ctr of Hurricane Was Estimated Near Latitude 30.6 North & Longitude 79.1 West.Storm Was Moving north-northwest at 14 Mph with Max Winds at 125 Mph | |
PNO-II-99-037H, on 990915,Hurricane Floyd Was Located Approx 168 Miles Southeast of Bsep.Ctr of Hurricane Was Estimated Near Latitude 31.3 North & Longitude 79.0 West.Storm Was Moving North at 17 Mph with Max Winds at 115 Mph | 15 September 1999 | PNO-II-99-037H:on 990915,Hurricane Floyd Was Located Approx 168 Miles Southeast of Bsep.Ctr of Hurricane Was Estimated Near Latitude 31.3 North & Longitude 79.0 West.Storm Was Moving North at 17 Mph with Max Winds at 115 Mph | |
IR 05000280/1999302 | 8 September 1999 | NRC Operator Licensing Retake Exam Repts 50-280/99-302 & 50-281/99-302 for Retake Exam Tests Administered on 990824. Exam Results:One SRO Candidate Received Part B re-take Operating Exam & Passed | Job Performance Measure |
ML20216F128 | 8 September 1999 | Insp Rept 70-1113/99-05 on 990809-13.No Violations Noted. Major Areas Inspected:Rountine Unannounced Insp Involved Observation of Work Activities,Review of Selected Records | Deep Dose Equivalent |
ML20211L300 | 31 August 1999 | Insp Rept 70-1113/99-04 on 990726-0805.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Emergency Preparedness | High winds |
PNO-II-99-035, on 990830,util Secured from Notification of Unusual Event After Hurricane Warning Lifted for Area.Plant Had Been Placed in Hot Shutdown Due to Predicted Hurricane Track.Unit 2 Commenced Restart on 990831 | 31 August 1999 | PNO-II-99-035:on 990830,util Secured from Notification of Unusual Event After Hurricane Warning Lifted for Area.Plant Had Been Placed in Hot Shutdown Due to Predicted Hurricane Track.Unit 2 Commenced Restart on 990831 | Siren |
PNO-II-99-033, on 990830,Hurricane Dennis Was Located Approx 72 Miles Southeast of Bsep.No Significant Damage Has Been Sustained at Site.Ge Facility Suspended Fuel Fabrication Processes & No Significant Damage Was Sustained | 30 August 1999 | PNO-II-99-033:on 990830,Hurricane Dennis Was Located Approx 72 Miles Southeast of Bsep.No Significant Damage Has Been Sustained at Site.Ge Facility Suspended Fuel Fabrication Processes & No Significant Damage Was Sustained | Siren |
IR 05000324/1999005 | 27 August 1999 | Insp Repts 50-324/99-05 & 50-325/99-05 on 990620-0731.Two Violations Noted Being Treated as Ncv.Major Areas Inspected: Operations,Maint & Plant Support | Condition Adverse to Quality Foreign Material Exclusion Excess Flow Check Valve Through-Wall Leak Through Wall Leak Loss of condenser vacuum |
ML20211F255 | 25 August 1999 | Insp Rept 70-1113/99-202 on 990802-06.No Violations Noted. Major Areas Inspected:Implementation of GE Fire Protection Program Commitments Re Safe Plant Operations | Fire Barrier Fire Protection Program Fire Watch Fatality |
ML20210V205 | 13 August 1999 | Insp Rept 70-1113/99-03 on 990712-16.No Violations Noted. Major Areas Inspected:Environ Monitoring Program | |
IR 05000321/1999004 | 4 August 1999 | Insp Repts 50-321/99-04 & 50-366/99-04 on 990530-0710.One Violation Noted & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support | Offsite Dose Calculation Manual Annual Radiological Environmental Operating Report Power change |
IR 05000321/1999010 | 20 July 1999 | Insp Repts 50-321/99-10 & 50-366/99-10 on 990616-25.One Violation Occurred & Being Treated as Ncv.Major Areas Inspected:Aspects of Licensee Operations,Maint,Problem Identification & Resolution & Corrective Actions | Half scram Temporary Modification Condition Adverse to Quality |
IR 05000324/1999004 | 19 July 1999 | Insp Repts 50-324/99-04 & 50-325/99-04 on 990509-0619. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.Includes Results of Y2K Readiness Program Review | High Radiation Area Locked High Radiation Area Condition Adverse to Quality Missed surveillance Foreign Material Exclusion Fuel cladding Fire Watch |
IR 05000321/1999003 | 25 June 1999 | Insp Repts 50-321/99-03 & 50-366/99-03 on 990418-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support | Temporary Modification Power Uprate |
PNO-II-99-025, on 990615,CR Operators Manually Shutdown Unit 2 Reactor from 41% Power,Due to Decreasing Condenser Vacuum. Cause of Decreasing Vacuum Has Not Been Determined.All Rods Installed as Required & All Safety Sys Functioned Properly | 17 June 1999 | PNO-II-99-025:on 990615,CR Operators Manually Shutdown Unit 2 Reactor from 41% Power,Due to Decreasing Condenser Vacuum. Cause of Decreasing Vacuum Has Not Been Determined.All Rods Installed as Required & All Safety Sys Functioned Properly | |
PNO-II-99-023, on 990601,one CEA Descended Into Reactor Core for Unknown Reasons,With Unit 2 Rated Power.Licensee Noted Voltage Fluctuations on CEA Power Supplies.Licensee Is Continuing to Investigate CEA Problems | 8 June 1999 | PNO-II-99-023:on 990601,one CEA Descended Into Reactor Core for Unknown Reasons,With Unit 2 Rated Power.Licensee Noted Voltage Fluctuations on CEA Power Supplies.Licensee Is Continuing to Investigate CEA Problems | |
IR 05000324/1999003 | 7 June 1999 | Insp Repts 50-324/99-03 & 50-325/99-03 on 990328-0508.Two Violations Noted & Being Treated as non-cited Violations. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support | Safe Shutdown Reactor Vessel Water Level Non-Destructive Examination Fire Barrier Weld Overlay Past operability Emergency Lighting Condition Adverse to Quality Missed surveillance Local Leak Rate Testing Fire Protection Program Power Uprate |
ML20195D413 | 4 June 1999 | Partially Withheld Insp Rept 70-1113/99-201 Conducted on 990510-14.No Violations Noted.Details Withheld,Per 10CFR2.790 | |
IR 05000280/1999301 | 14 May 1999 | NRC Operator Licensing Exam Repts 50-280/99-301 & 50-281/99-301 (Including Completed & Graded Exams) for Tests Administered on 990329-0401 & 990412-15 | Shutdown Margin Reserve Station Service Transformer Job Performance Measure Coast down |
PNO-II-99-016, on 990505,Hatch Unit 2 Had Main Generator Trip Form 98% Power,Due to Electrical Fault.Licensee Continuing Investigation Has Been Hampered Due to Inclement Local Weather Conditions.Plant Being Depressurized | 7 May 1999 | PNO-II-99-016:on 990505,Hatch Unit 2 Had Main Generator Trip Form 98% Power,Due to Electrical Fault.Licensee Continuing Investigation Has Been Hampered Due to Inclement Local Weather Conditions.Plant Being Depressurized | |
IR 05000321/1999002 | 6 May 1999 | Insp Repts 50-321/99-02 & 50-366/99-02 on 990307-0417.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | High Radiation Area Weld Overlay Nondestructive Examination Temporary Modification Foreign Material Exclusion Scram Discharge Volume |
IR 05000324/1999002 | 26 April 1999 | Forwards Insp Repts 50-324/99-02 & 50-325/99-02 on 990214-0327.No Violations Noted.Major Areas Inspected: Licensee Operation,Engineering,Maint & Plant Support | Safe Shutdown Fitness for Duty High Radiation Area Fire Barrier Hydrostatic Fire impairment Missed surveillance Coast down |
IR 05000321/1999001 | 2 April 1999 | Insp Repts 50-321/99-01 & 50-366/99-01 on 990124-0306.Non- Cited Violations Identified.Major Areas Inspected:Maint, Operations & Plant Support | Fire Barrier Fire Protection Program |
IR 05000324/1998014 | 18 March 1999 | Insp Repts 50-324/98-14 & 50-325/98-14 on 990111-15,25 & 29. No Violations Noted.Major Areas Inspected:Licensee Calculations,Analysis,Performance Test Procedures & Other Engineering Activities | Safe Shutdown Stroke time Operability Determination Maintenance Rule Program Power Uprate Overspeed trip Loss of condenser vacuum |
IR 05000324/1999001 | 15 March 1999 | Insp Repts 50-324/99-01 & 50-325/99-01 on 990103-0213.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support | Non-Destructive Examination Offsite Dose Calculation Manual Nondestructive Examination Annual Radiological Environmental Operating Report Stress corrosion cracking Fire Protection Program Power change Downpower Reverse polarity Siren |
IR 05000321/1998009 | 24 February 1999 | Insp Repts 50-321/98-09 & 50-366/98-09 on 981213-990123.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.Rept Covers Insp in Health Physics & Independent Spent Fuel Storage | Operability Assessment |
ML20203G467 | 5 February 1999 | Insp Rept 70-1113/99-01 on 990111-15.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Personnel in Area of Radiation Protection | Deep Dose Equivalent |
ML20202J100 | 29 January 1999 | Insp Rept 70-1113/99-02 on 990104-08.No Violations Noted. Major Areas Inspected:Plant Operations,Environ Protection & Training | |
IR 05000324/1998011 | 28 January 1999 | Insp Repts 50-324/98-11 & 50-325/98-11 on 981122-990102.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Plant Support | High Radiation Area Fire Protection Program |
IR 05000321/1998007 | 29 December 1998 | Insp Repts 50-321/98-07 & 50-366/98-07 on 981101-1212.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support | Power Uprate |
IR 05000324/1998010 | 21 December 1998 | Insp Repts 50-324/98-10 & 50-325/98-10 on 981011-1121. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.Also Includes Results of Engineering & Health Physics Insp | Safe Shutdown Time of Discovery Stroke time Anchor Darling Locked High Radiation Area Scaffolding |
ML20198P026 | 21 December 1998 | Notice of Violation from Insp on 981011-1121.Violation Noted:On 981030,licensee Failed to Correctly Shutdown & Verify That Unit 1 Standby Gas Treatment Sys in Standby Alignment Per Section 7.1 of Procedure 1OP-10 | |
IR 05000324/1998013 | 24 November 1998 | Partially Withheld Insp Repts 50-324/98-13 & 50-325/98-13 on 981026-30 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Aspects of Licensee Plant Support | |
PNO-II-98-050, on 981123,licensee Declared Notification of Unusual Event,Due to Release of Chlorine Gas from Svc Water Injection Sys in Chlorination Bldg.Personnel Were Moved to Alternate Locations Away from Gas Leak,As Precautionary | 24 November 1998 | PNO-II-98-050:on 981123,licensee Declared Notification of Unusual Event,Due to Release of Chlorine Gas from Svc Water Injection Sys in Chlorination Bldg.Personnel Were Moved to Alternate Locations Away from Gas Leak,As Precautionary | |
IR 05000321/1998006 | 24 November 1998 | Insp Repts 50-321/98-06 & 50-366/98-06 on 980920-1031. Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support | Offsite Dose Calculation Manual |
ML20195G419 | 9 November 1998 | Notice of Violation from Insp on 980830-1010.Violation Noted:On 980916,licensee Failed to Perform Section 7.1.5 of Procedure OMST-RHR-28Q as Required When Returning Flow Transmitter E11-FT-3338 to Service | Stroke time |
IR 05000324/1998009 | 9 November 1998 | Insp Repts 50-324/98-09 & 50-325/98-09 on 980830-1010. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support | Offsite Dose Calculation Manual Stroke time Past operability Job Performance Measure Operability Determination Operability Assessment |
IR 05000321/1998005 | 15 October 1998 | Insp Repts 50-321/98-05 & 50-366/98-05 on 980802-0919.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support.Insp Also Included Insps by Regional Maint & Emergency Preparedness | High Radiation Area Grab sample Fire Barrier Maintenance Rule Program |
ML20155A856 | 30 September 1998 | Insp Rept 70-1113/98-05 on 980908-10.No Violations Noted. Major Areas Inspected:Licensee Program for Security & Safeguards | |
IR 05000324/1998008 | 28 September 1998 | Insp Repts 50-324/98-08 & 50-325/98-08 on 980719-0829.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support | Safe Shutdown Fire Barrier Stroke time Emergency Lighting Missed surveillance Fire Protection Program Early Warning Fire Detection Siren |
PNO-II-98-040, on 980917,licensee Declared Notification of Unusual Event Based on Transport of Two Injured & Potentially Contaminated Individuals to Local Hospital.Two Individuals Found Not to Have Sustained Serious Injury | 18 September 1998 | PNO-II-98-040:on 980917,licensee Declared Notification of Unusual Event Based on Transport of Two Injured & Potentially Contaminated Individuals to Local Hospital.Two Individuals Found Not to Have Sustained Serious Injury | |
ML20154C342 | 11 September 1998 | Insp Rept 70-1113/98-03 on 980817-21.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Transportation Program for Radioactive Matls & Radioactive Waste Mgt Program |