Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML20198L409 | 17 December 1998 | Notice of Violation from Insp on 981005-1122.Violation Noted:Mod DI-96-007,replacement of Mssrv 3 Way Solenoid Valves,Conducted Feb 1996 Forced Outage Installed Cabling to Mssrv Solenoid Valves Without Use of Conduit | |
ML20154B828 | 28 September 1998 | Notice of Violation from Insp on 980727-0814.Violation Noted:Util Did Not Correctly Translate Applicable Design Basis for safety-related Sys & Components Into Plant Design | |
ML20151V787 | 10 September 1998 | Notice of Violation from Insp on 980713-0823.Violation Noted:On 980722,inspectors Observed Performance of Inadequate Vehicle Search.Specifically,Security Force Member Failed to Thoroughly Search Passenger Compartment | |
ML20236M312 | 2 July 1998 | Notice of Violation from Insp on 980420-0531.Violation Noted:On 980501,actions Taken Per Other Plant Procedures Contradicted Actions Specified by EOPs | |
ML20247P097 | 18 May 1998 | Notice of Violation from Insp on 980222-0419.Violations Noted:On 980213,test Program for Reactor Bldg Sys Did Not Assure That All Testing Required to Demonstrate That Sys Would Perform Satisfactorily in Service,Performed | |
ML20216G477 | 12 March 1998 | Notice of Violation from Insp on 971222-980222.Violation Noted:On 980128,licensee Failed to Isolate Secondary Containment & Starts SBGTS When Only Channel of Reactor Bldg Radiation Monitor Sys Below Refueling Floor,Inoperable | |
IR 07100027/2012021 | 20 January 1998 | Notice of Violation from Insp on 971027-1221.Violation Noted:Procedures Not Followed While Performing AOP-23,DC Power Sys Ground Isolation,In Sequence That Breakers Shall Be Opened to Isolate Sys Grounds Not Followed | |
ML20199H184 | 17 November 1997 | Notice of Violation from Insp on 970831-1026.Violation Noted:Maintenance That Affects Performance of Safety Related Equipment Not Properly Preplanned & Performed in That Main Procedure Was Incorrect & Resulted in Using Wrong Oil | |
ML20141E411 | 23 June 1997 | Notice of Violation from Insp on 970304-13.Violation Noted: ST-20C Was Not Followed,In That CR That Was Not Fully Withdrawn to Position 48 Was Selected for Movement & Shift Manager Permission Was Not Obtained Prior to Performance | |
ML20141A233 | 13 June 1997 | Notice of Violation from Insp on 970413-0525.Violation Noted:Radiation Workers Did Not Comply W/Radiation Protection Instructions as Identified in Listed Examples | |
ML20196G498 | 8 May 1997 | Notice of Violation from Insp on 970223-0412.Violation Noted:Licensee Failed to Take Prompt & Adequate Corrective Action for Condition Adverse to Quality | Condition Adverse to Quality |
ML20137E969 | 24 March 1997 | Notice of Violation from Insp on 970105-0222.Violation Noted:No Safety Evaluation Was Performed & Documented to Provide Bases for Determination That Change Did Not Involve Unreviewed Safety Question | |
ML20134E370 | 30 January 1997 | Notice of Violation from Insp on 961117-970104.Violations Noted:All Four RHR Sys Pumps Were Operated in Suppression Pool Cooling Mode for Ten Hours,Prior to Performance & Documentation of SE | |
ML20132C839 | 13 December 1996 | Notice of Violation from Insp on 960929-1116.Violation Noted:On 961111,CRDs to Be Removed Not Accurately Located Prior to Removal Which Resulted in Incorrect Removal of Tree CRDs | High Radiation Area Locked High Radiation Area Pressure Boundary Leakage |
ML20129F441 | 24 October 1996 | Notice of Violation from Insp on 960728-0928.Violation Noted:On 960916,during Work Associated W/Wr 96-02875-00,to Perform Calibration of 71-59N-1UPRN05,two Instances Occurred Where Procedures Not Followed Resulted in Reactor Trip | |
ML20058B727 | 18 October 1990 | Notice of Violation from Insp on 900812-0922.Violation Noted:Util Did Not Determine & Correct Conditions Adverse to Quality Re 900628 Unplanned Isolation of RWCU Sys | |
ML20059L227 | 4 September 1990 | Notice of Violation from Insp on 900701-0811.Violation Noted:Nine Security Guards Failed to Adhere to Posting Requirements | High Radiation Area |
ML20246F750 | 22 August 1989 | Notice of Violation from Insp on 890501-26.Violations Noted: Reactor Bldg Closed Loop Cooling Water Sys May Not Remain Closed Following LOCA Due to Plant Design & Failure of Stated Functional Test to Address Calibr of Level Switches | |
ML20248A589 | 2 August 1989 | Notice of Violation from Insp on 890613-15.Violations Noted: Surveys Provided to Support on-going Spent Fuel Pool Work on 890612 Inadequate to Readily Identify Presence of Highly Radioactive Object,Causing Personnel Exposure | |
ML20247J951 | 22 May 1989 | Notice of Violation from Insp on 890305-0418.Violation Noted:Licensee Failed to Notify NRC Operations Ctr within 4 Hr of Determinig That Condition Existed,Dealing W/ Potential Loss of Instrument Air | |
ML20247A037 | 22 March 1989 | Notice of Violation from Insp on 890122-0304.Violation Noted:Controlled Drawing FE-1AW,in Control Room,Unmarked to Reflect Affecting Mod 87-45 | |
ML20236D669 | 13 March 1989 | Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $75,000.Violations Noted:Inoperable Room Coolers & Excessive Svc Water Temp | |
ML20206K805 | 21 November 1988 | Notice of Violation from Insp on 881011-14.Violation Noted: Noted:Installed half-lapped Layers of Okonite Cable Splices Less than 3/8-1/2 Inch half-lapped Layer Required Per Qualified Configuration | |
ML20195H300 | 16 November 1988 | Notice of Violation from Insp on 881011.Violation Noted: Waste Shipment of Solidified Resin Transferred for Disposal, But Not Completely Solidified & Contained 7.6% Picolinic Acid | |
ML20206C832 | 3 November 1988 | Notice of Violation from Insp on 880808-1005.Violation Noted:Nitrogen Precharge of Discharge Accumulator Performed W/Scram Valves Open & Caused Inadvertent Insertion of Associated Control Rod | |
ML20205J553 | 20 October 1988 | Notice of Violation from Insp on 880808-19.Violation Noted: Pipe Supports Removed on or Before 880121 Not Reconnected Until After NRC Inspectors Identified Concern on 880815 & Unauthorized Hose Clamps Installed on RCIC Sys | |
ML20151Y455 | 18 August 1988 | Notice of Violation from Insp on 880618-0807.Violation Noted:Failure to Complete Required Tech Spec Surveillance Test Identified | |
ML20207D388 | 8 August 1988 | Notice of Violation from Insp on 880606-0610.Violation Noted:Audit of Liquid & Gaseous Radioactive Effluent Portions of Tech Specs Not Performed within 12 Month Interval as Required | |
ML20153D769 | 29 April 1988 | Notice of Violation from Insp on 880222-26.Violation Noted: Figure 8.1 Not Used to Record Test Info for Listed Valves or for power-operated Category B Valves | Stroke time |
ML20150G065 | 29 March 1988 | Notice of Violation from Insp on 880112-0307.Violation Noted:Lpci Manual Isolation Valve 10-RHR-81A Open But Not Locked on 880123 | |
ML20236Q495 | 13 November 1987 | Notice of Violation from Insp on 870901-1020.Violation Noted:High Vibration Trip of Reactor a Feed Pump Turbine Disabled W/O Written Safety Evaluation to Determine That Change Does Not Involve Unreviewed Safety Question | Scaffolding |
ML20235J504 | 23 September 1987 | Notice of Violation from Insp on 870427-0501.Violations Noted:Verification Data for Two Commercial Grade Items Not Available to Demonstrate That Specified Critical Component Character Met | |
ML20235H484 | 11 September 1987 | Notice of Violation from Insp on 870825-28.Violation Noted: Two Limitorque Operators Located in Reactor Bldg at Elevation 326 Ft & 338 Ft,Containing Nine Cable Splices Whose Qualification Not Established | |
ML20214E002 | 12 May 1987 | Notice of Violation from Insp on 870330-0403 | |
ML20209H620 | 22 April 1987 | Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $75,000.Noncompliance Noted:Worker Hands Exposed to Excessive Radiation on 870213.Radiation Safety Inadequate Re Surveys Training & Adherence to Tech Specs | |
ML20209D587 | 20 April 1987 | Notice of Violation from Insp on 870316-20 | High Radiation Area |
ML20205G250 | 23 March 1987 | Partially Withheld Notice of Violation from Insp on 870112-16 (Ref 10CFR73.21) | |
ML20213F664 | 10 November 1986 | Notice of Violation from Insp on 860809-0929 | |
ML20203K506 | 14 August 1986 | Notice of Violation from Insp on 860721-25 | |
ML20214J603 | 8 August 1986 | Notice of Violation from Insp on 860714-18 | |
ML20202F626 | 9 April 1986 | Notice of Violation from Insp on 860118-0310 | |
ML20154D428 | 27 February 1986 | Notice of Violation from Insp on 851201-860117 | |
ML20140C896 | 17 January 1986 | Notice of Violation from Insp on 851012-1130 | |
ML20137F586 | 21 August 1985 | Notice of Violation from Insp on 850617-21 | Safe Shutdown Fire Barrier |
ML20128C683 | 21 June 1985 | Notice of Violation from Insp on 850422-26 | High Radiation Area |
ML20128B165 | 10 May 1985 | Notice of Violation from Insp on 850318-22 | High Radiation Area |
ML20054J698 | 14 June 1982 | Notice of Violation from Insp on 820501-31 | Fire Barrier Continuous fire watch Fire Protection Program Fire Watch |