ML20207D388

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 880606-0610.Violation Noted:Audit of Liquid & Gaseous Radioactive Effluent Portions of Tech Specs Not Performed within 12 Month Interval as Required
ML20207D388
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 08/08/1988
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20207D376 List:
References
50-333-88-10, NUDOCS 8808150336
Download: ML20207D388 (1)


Text

..- ..

APPENDIX A NOTICE OF VIOLATION New York Power Authority Docket No. 50-333 James A. FitzPatrick Nuclear Power Plant License No. OPR-59 As a result of the inspection conducted on June 6-10, 1988 and in accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions,"

10 CFR Part 2, Appendix C (Enforcement Policy) (1988), the following violation was identified:

Technical Specification 6.5.2.8 of Appendix A to Facility Operating License No. OPR-59, Technical Specifications, requires audits of the conformance of the facility operation to provisions contained within the Technical Specifications (TS) and applicable license conditions at least once per 12 months; and audits of the Radiological Environmental Monitoring Program (REMP) and results at least once per 12 months.

Contrary to the above requirements, an audit of the liquid and gaseous radioactive effluent portions of the TS and the REMP was not performed within the 12 month interval as required. The last audit.of the radioactive effluents portion of the TS and the REMP was. conducted in November, 1986.

This is a Severity level V Violation (Supplement 1)

Pursuant to the provisions of 10 CFR 2.201, New York Power Authority is hereby required to submit to this office within thirty days of the date of the letter which transmitted this Notice, a written statement or explanation in. reply, including: (1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further violations; and (3) the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending this response time.

Nk G

D f OFFICIAL RECORD COPY IR FITZ 88 0003.0.0 08/02/88 l