APPENDIX A NOTICE OF VIOLATION New York Power Authority Docket No.

50-333 James A. FitzPatrick Nuclear Power Plant License No. DPR-59 Lycoming, New York 13093 As a result of the inspection conducted on July 14-18, 1986, and in accordance with the NRC Enforcement Policy (10 CFR 2. Appendix C), the following violation is identified:

10 CFR 50 Appendix B, Criterion'XIII states: " Measures shall be established to control..... storage.....and preservation of material and equipment...

to prevent damage or deterioration......"

Paragraph 6.4.2 of ANSI N45.2.2-1972, committed to by the licensee in FSAR Chapter 17, Appendix 17.2.B. requires the " Care of Items" in storage, including periodic rotation of shafts of rotating equipment and other in-storage maintenance requirements specified by the manufacturer.

Contrary to the above as of July 18, 1986 the licensee's measures for the care of items in storage was inadequate as evidenced by the following examples:

1.

The shafts of safety related Residual Heat Removal System Pumps pro-cured under Puchase Order (P0) 84-2595 and stored since April 1984 were not rotated on montiely basis as specified by the manufacturer.

2.

Safety related cylinders procured under P0 83-1491 and stored since November 1983 were not lubricated and cycled as specified by the manufacturer.

This is a Severity Level IV Violation (Supplement I)

Pursuant to the provisions of 10 CFR 2.201, the New York Power Authority, is hereby required to submit to this office within thirty days of the date of the letter which transmitted this Notice, a written statement or expla-nation in reply, including (1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further violations; and (3) the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending this response time.