 Issue dateTitleTopic
ML20217A16922 September 1999Part 21 Rept Re Engine Sys,Inc Controllers,Manufactured Between Dec 1997 & May 1999,that May Have Questionable Soldering Workmanship.Caused by Inadequate Personnel Training.Sent Rept to All Nuclear Customers
ML20207M92312 March 1999Amended Part 21 Rept Re Cooper-Bessemer Ksv EDG Power Piston Failure.Total of 198 or More Pistons Have Been Measured at Seven Different Sites.All Potentially Defective Pistons Have Been Removed from Svc Based on Encl Results
ML20140A96629 May 1997Part 21 Rept Re Ksv Emergency Diesel Generator Power Piston Failure.Caused by Jacket Water in Combustion Chamber. Recommends That Users Verify That Crown Thickness at Valve Cutout Be 100 MinimumFinite Element Analysis
NSD-NRC-97-5093, Part 21 Rept Re W Identified Defects That Could Create Substantial Safety Hazard Should Defect Remain Uncorrected. Plans to Complete Proper Refurbishment of All of Returned Breakers Being Established14 May 1997Part 21 Rept Re W Identified Defects That Could Create Substantial Safety Hazard Should Defect Remain Uncorrected. Plans to Complete Proper Refurbishment of All of Returned Breakers Being Established
ML20137G62625 March 1997Svcs Part 21 Rept Re Emergency Generators Installed at Zion Station Which Developed Significant Drop in Crankcase Lube Oil Level.Caused by Crack in Liner Wall,Allowing Jacket Water to Enter ChamberFinite Element Analysis
ML20135E3813 March 1997Part 21 Rept Re Output Drift W/Increasing Temperature on Several RTD Amplifiers Noted During Installation of RTD by-pass Mod at Station.Action to Identify All Circuit Cards W/Affected Date Codes,Identified
ML20117G46414 May 1996Part 21 Rept Re Cooper Bessemer Reciprocating Products,Div of Cooper Cameron Corp,Issued Ltr to Define Utils/Plants Containing Similar Equipment as Supplied on Cooper Bessemer Ksv & Enterprise Dsr EDGs
ML20097J63530 January 1996Part 21 Rept Re Intermittent Failure of DG Relay Mfg by Amerace Electronic Components.Suspect Relays at Plants Identified & Replaced.Amerace Indicated That Operators & QC Personnel Made Aware of Need for Proper Soldering
ML20096E65118 January 1996Part 21 Rept Re Failure of MOV Motor Pinion Gear Mfg by Limitorque at Byron Station.Replacement & Insp Activities Initiated for Potentially Impacted Populations of MOVs at Byron & Braidwood StationsTime of Discovery
ML20094R73928 November 1995Potential Part 21 Rept Re Ksv EDG Sys Mfg by Cooper-Bessemer Reciprocating Products Div,Div of Cooper Cameron Corp. Recommends That All Utils Verify Open Oil Passage in Assembly
ML20082Q94921 April 1995Part 21 Rept Re Notifying Commission of Potential Design Defect of Ksv EDG Sys
ML20077D34329 November 1994Part 21 Rept Re Suspect Master Connecting Rods & Contains Info Location in Engine for Rods
ML20078G3059 November 1994Rev to Part 21 Rept Re Potential Problem W/Master Power Connecting Rods.Vendor Recommends Listed Utils Perform Visual Insp of Master Rods to Determine Applicability of Rept
ML20071J18922 July 1994Final Part 21 Rept Re Cracks Found in Body to Bonnet Nuts on Copes-Vulcan Airoperated Valves.Operability Evaluation for Byron Units 1 & 2,of Affected Valves W/Nuts of Heat Numbers H & I Completed on 940622Time of Discovery
ML20073S95427 June 1994Part 21 Rept Re Incorrect Matl Supply Discovered on Unshipped Order.Pump Div Will Notify Enertech W/ Recommendation That Items Supplied W/Incorrect Matl Be Removed & Destroyed
ML20070A14422 June 1994Part 21 Rept Re Conditions Which Affect Hydraulic Valve Operators Supplied by Bw/Ip to Enertech Co & Listed Utils. Vendor Will Notify Enertech W/Recommendations That All Items Supplied W/Incorrect Matl Be Removed & Destroyed
ML20059L98611 November 1993Part 21 Rept Re Deviation Wherein Fully Open Butterfly Valve Located 15 Pipe Diameters Upstream of Sensors Was Disturbing Flow Profile Enough to Cause Ultrasonic Meter to Indicate 3 to 4% Low.Customers Notified & Valve Removed
ML20127M52024 November 1992Final Part 21 Rept Re Reject Lot Serial Numbers of Defective Fuel Nozzle Tips,Consisting of Corrected Page 6 of 921102 Rept Re Reject Lots for Fuel Injector Assembly
ML17223A74526 January 1990Part 21 Rept Re Backup Rings Furnished in Spare Parts Seal Kits & in 25 Gpm 4 Way Valves as Part of Actuators Made of Incorrect Matl.Rings Should Be Viton & Have Been Identified as Buna N
ML20207P0154 October 1988Part 21 Rept Re Fuel Nozzle Tips in Standby Diesel Generator KSV-20-T W/Cracks Permitting Diesel Fuel to Be Sprayed Into Cylinders.Heavy Vapors Observed Emitting from Breathers on Some Cylinder Heads
ML20149H82111 February 1988Final Deficiency Rept 457/87-01 Re Diesel Engine Generator Rocker Arm Failure.Initially Reported on 870217.Util Took Steps to Determine Strength of Rocker Arms.Low Strength Rocker Arms Replaced W/New Rocker Arms
ML20214H82215 May 1987Interim Deficiency Rept Re Diesel Engine Generator Rocker Arm Failure.Initially Reported on 870217.Test/replacement Program Started,Contingent on Receipt of Replacement Exhaust Rocker Arms from Cooper-Bessemer
ML20206Q8822 April 1987Interim Deficiency Rept Re Diesel Engine Generator Rocker Arm Failure.Initially Reported on 870217.Investigation Emcompasses Both Metallurgical Analysis & Mechanical Interactions.Next Rept Will Be Submitted by 870501
ML20205B66917 March 1987Deficiency Rept Re Diesel Engine Generator Rocker Arm Failure.Initially Reported on 870217.Diesel Generator Repaired by Honing Out Crosshead to Crosshead Guide Clearance to 0.006 Inches.Next Rept Submitted by 870430
ML20211P72123 February 1987Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly
ML20212H54512 January 1987Part 21 Rept Re Break of Master Power Rod at Fractured Surface.Caused by Fatigue Failure Originating in Rod When Iron Plating in Articulated Rod Pin Bore Failed,Resulting in Engine Inoperability.Rod Replaced
ML20207P18029 December 1986Final Deficiency Rept 86-02 Re Rejectable Indications During Preservice Insp on Loop 1 Steam Generator.Actions Necessary to Resolve Items Completed,Per Suppls 1 & 2 to NUREG-1002
ML20212D97223 December 1986Interim Deficiency Rept 84-14 Re Weld & Grindout Identified During Preservice Insp.Initially Reported on 841121.New Data Demonstrates That Indication Size Meets ASME Section XI 1WB-3512,1977 Edition.Indication Grindout No Longer Needed
ML20215F95319 December 1986Part 21 Rept Re Design Error Uncovered in Certain Safety Shutdown Circuits for Standby Diesel Generator.Switches 12E0-1,12E0-2,33E0-1 & 33E0-2 Not Intended to Initiate Emergency Mode Trip as Drawings Indicate
ML20214T51126 November 1986Deficiency Rept Re Misplaced Radiographs for Westinghouse Equipment.Initially Reported on 861030.Item Not Reportable Per 10CFR50.55(e)
ML20215H22317 October 1986Revised Final Deficiency Rept 84-07 Re Crush Strength of Energy Absorbing Matl Used in Pipe Whip Restraints.Removal of Four Addl Restraints in Unit 1 Took Place on 851004 During Unit 1 Outage
ML20210N65626 September 1986Final Deficiency Rept 85-06 Re Failure of Diesel Generators 1A & 1B to Sustain Adequate Prime During Testing.Initially Reported on 850822.Fuel Oil Sys Modified & Tested
ML20214W56419 September 1986Deficiency Rept Re 860818 Inadvertent Discharge of Water Into Spent Fuel Pit Where 64 New Fuel Assemblies for Initial Core Load Being Stored.Initially Reported on 860819.Event Not Reportable Per 10CFR50.55(e)
ML20210F47817 September 1986Final Part 21 & Deficiency Rept 86-06 Re Fastener Matl Supplied by Cardinal Industrial Products.Initially Reported on 860617.Fastener Matl Met ASME Code Requirements. Documentation of Corrective Actions Available Onsite
ML20203N19316 September 1986Final Deficiency Repts 84-05 & 84-15 Re Inconsistencies in Documentation of Gk Newberg Structural Steel Installations & Welding Program,Respectively.Initially Reported on 840417. Installation Travelers Reviewed.Deficiencies Resolved
ML20214M3184 September 1986Potential Part 21 Rept Re Contromatics Actuator W/Jackscrew/ Handwheel Emergency Override Operator.Jackscrew/Handwheel Should Be Used for Emergency Manual Operation Only.Encl Ltr Also Sent to Listed Utils/Ae Firms
ML20214P5122 September 1986Final Deficiency Rept 83-08 Re Fabrication of Pullman Sheet Metal Duct Fittings W/O Approved Design Documentation. Initially Reported on 830630.Unit 1 Fitting Mods Completed on 860501.Reworking of 12 Fittings Remain for Unit 2
ML20205F72112 August 1986Revised Final Deficiency Rept 84-12 Re Removal of Name Plates from ASME Large Bore Spool Pieces.Initially Reported on 840824.Replacement Identification Plate Not Attached to Installed Spool Pieces.Procedure Revised to Reflect Change
ML20212K27412 August 1986Final Deficiency Repts 84-05 & 84-11 Re Boeing Steam Generator Snubber Failure.Initially Reported on 840628. Snubber Functional Test Results Reviewed & Acceptable. Snubbers Refurbished for Listed Units
ML20212B37929 July 1986Interim Deficiency Rept 86-06 Re Fastener Matl Supplied by Cardinal Industrial Products.Initially Reported on 860617. Matls Over 1 Inch in Diameter Shipped During 840109-850815 & Not Included in Notification Ltrs Acceptable
ML20206B13711 June 1986Final Deficiency Rept 84-04 Re out-of-tolerance Radiographic Film Densities.Initially Reported on 840406. Unit 1 Production Welds Repaired &/Or Reradiographed & Welder Qualifications Evaluated & Confirmed
ML20211F1975 June 1986Final Deficiency Repts 86-03 by & 86-05 Bw Re Cold Leg Safety Injection Pipe Vibration & Cracks.Initially Reported on 860430.D Loops Changed to 5-D Bends & Support Added for Addl Stiffness
ML20211E3474 June 1986Final Deficiency Repts 84-06(BY) & 84-14(BW) Re Large Laminar Indication in Steam Generator Snubber Piston Rod End Blade.Initially Reported on 840731.Rod End & Six End Caps Replaced
ML20198E89820 May 1986Final Deficiency Repts 86-01 & 86-03 Re Defective Spot Welds on Cable Tray Hanger Strut Matl.Initially Reported on 860306.Engineering Evaluation Performed for Hangers Remaining W/Suspect Control Numbers
ML20197E8269 May 1986Final Deficiency Rept 86-04 Re 21 Rejectable Weld Indications Identified During Preservice Insp.Initially Reported on 860409.Relief from Repair Requirements Will Be Requested for 12 Unacceptable IndicationsNon-Destructive Examination
Hydrostatic
ML20210L04422 April 1986Final Deficiency Repts 86-02 for Byron & 86-04 for Braidwood Re Failures of Diesel engine-generator Rocker Arm.Initially Reported on 860327 by Util & 860311 by Cooper Industries Under Part 21
ML20210E08018 March 1986Final Deficiency Rept 84-17 Re Concrete Expansion Anchor Installations.Sargent & Lundy Evaluation Complete.No Significant Design Discrepancies Noted.Util Nonconformance Repts 658 & 659 Closed
ML20141N86012 March 1986Interim Deficiency Rept 86-01 Re Discrepant Spot Welds on Cable Tray Hangers Made of P1004A Unistrut Matl.Initially Reported on 860210.Walkdown of Hangers Completed & All Discrepant Welds Recorded
ML20141N79011 March 1986Part 21 Rept Re Inlet Rocker Arm Failure in Cooper Bessemer Corp Engines S/N 7177 & 7178.Broken Rocker Arms Constitute Secondary Failure.Primary Failure Was Seizure of Valve Train Crossheads in Up Position
ML20137Z5006 March 1986Interim Deficiency Rept 86-03 Re Defective Spot Welds on Cable Tray Hanger Strut Matl.Initially Reported on 860121. Unit 2 Containment Hangers Will Be Replaced & Unit 1 Hangers Will Be Repaired or Replaced