Commonresith Edison
.1 < Ona First Ndonal Plaza, Chicago, Illinois th10RITY RCUTING Address Reply to: Post Offee Box 767 dif.it Ip"d i
Chicago, Illinois 60690 - 0767 gg 9/L RL_;w a dss l t,;
20)5 l I
November 26, 1986 FILE M bmB Mr. James G. Keppler Regional Administrator l
U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL. 60137 l
Subj ect: Byron Station Unit 2 Retrievability of Radiographs NRC Docket No. 50-455 Reference (a): October 29, 1986 letter from S.C. Hunsader to J.G. Keppler
Dear Mr. Keppler:
On October 30, 1986 a potential deficiency was reported to Mr. Robert Lerch of your office pursuant to 10CFR 50.55(e). The deficiency involved misplaced radiographs for equipment supplied by Westinghouse. Based on further review of this item, we have concluded it does not meet the reportir.g requirements of 10CFR 50.55(e).
Reference (a) documents Connonwealth Edison's corrective actions regarding the misplaced radiographs.
Please direct any questions regarding this matter to this office.
Very truly yours, K. A. Ainger Nuclear Licensing Administrator
/klj cc: Resident Inspector-Byron 2451K 8612090613 861126 PDR ADOCK 05000455 S