Final Deficiency Repts 84-05 & 84-11 Re Boeing Steam Generator Snubber Failure.Initially Reported on 840628. Snubber Functional Test Results Reviewed & Acceptable. Snubbers Refurbished for Listed Units
ML20212K274
Person / Time
Site: Byron, Braidwood, 05000000
Issue date: 08/12/1986
From: Miosi A
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
1973K, 84-05, 84-11, 84-5, NUDOCS 8608190318
Download: ML20212K274 (2)


Text

'

pmg l

't

/

'S Commonwealth Edison l

-g One First Nabonal Plaza Ch' ago, Illinois c

\\

Address Reply t;: Post Office Box 767 ke/ Chicago, Illinois 60690 - 0767 August 12, 1986 Mr. James G. Keppler Regional Administrator U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL. 60137

Subject:

Byron Station Units 1 and 2 Braidwood Station Units 1 and 2 10 CFR 50.55(e) 84-05(BY) and 84-ll(BW) Final Report Steam Generator Snubber Failure NRC Docket Nos. 50-454/455 and 50-456/457 References (a):

E.D.

Swartz letter to J.G.

Keppler dated July 31, 1984 (b):

O.R.

Sanders letter to R.A.

Salsbury dated September 10, 1984 (c):

E.D.

Swartz letter to J.G.

Keppler dated September 26, 1984

Dear Mr. Keppler:

On June 28, 1984, the Commonwealth Edison Company notified your office of a deficiency reportable pursuant to 10CFR 50.55(e) concerning the unsatisfactory operation Curing confirmatory testing I

of the Steam Generator Snubbers supplied by the Boeing Company for our Byron and Braidwood Stations.

Reference (a) provided the thirty day report concerning this matter.

The purpose of this letter is to provide the Final Report.

We have reviewed the steam generator snubber functional j

test results and find them acceptable.

The snubbers have been refurbished and tested for By'ron Unit 2 and Braidwood 1 and 2.

This testing was performed per procedures which were reviewed by CECO, Sargent & Lundy, and NRC Region III.

1 l

8608190318 860812 ADOCKOSOOOg4 PDR S

-T5c2 ?

,\\

s.

- Please address any questions that you may have concerning this matter to this office.

Very truly yours, h

t4'

!!l4T*

A. D. Miosi Nuclear Licensing Administrator

/klj cc:

Resident Inspector-Byron

-Braidwood Director of Inspection & Enforcement U.S. Nuclear Regulatory Commission Washington, DC. 20555 1

1973K l

\\

r i

l