4 4.4 Detroit re ma Ecison _w._ -

em Feb rua ry 26, 1992 NRC-92-0033 Mr. John R. Jolicoeur EFDS Project Manager Mail Stop MNBB 3206 U. S. Nuclear Regulatory Commission Washingt on, D. C. 20555

References:

1) Fermi 2 NRC Docke t No. 50-341 NRC License No. NPF-43
2) 10 CFR Part 50 Emergency Response Data System.

Final Rule. Federul Register (56 FR 40178),

da t ed Augu s t 13, 1991

3) NUREG-1394, Rev. 1. " Emergency Response Data System (ERDS) Implementation," dated June 1991
4) Detroit Edison Letter to NRC, " Fermi 2 Emergency Fesponse Data System (ERDS) Implementation Program Plan," NRC-91-0132, dated October 28, 1991

Subject:

Submittal of ERDS Data _ Point Library for Fermi 2 As discussed in Detroit Ediron leeter to the NRC dated October 28, 1991 (Reference 4) enclosed is the ERDS Data Point Library for Fermi

2. This Data Point Library has been prepared in accordance with NUREG-1394, Rev. 1 (Ref e rence 3) .

An described in Reference 4, assuming the NRC approval of this Data Point Libraty by June 1992, Detroit Edison expects to complete the Engineering Design Package (EDP) on ERDS by July 1992. As commit t ed to in the Referance 4 letter, implementation of the EDP is expected to be completed by November 1992 and the ERDS will be available for use at Fermi 2 by February 13, 1993. l I

r n : ' (? '*

l l

I^&Ovo ( ,

1,

- # I 9203030200 920226 }

PDR ADOCK 03000341 1 F PDR

9

. Mr. John R. Jolicoeur Februa ry 26, 1992 NRC-92-0033 Page 2 If you have any q sestions, please contact Mr. Girija S. Shukla at (313) 586-4270.

Sincerely, A. C. Set tles Director, Nuclear Licensing Enclosure ACS/raa ec: T. G. Colburn (w/c encl. )

A. B. Davis (w/o encl.)

R. W. DeFayette (w/o encl.)

S. Stasek (w/o encl . )

U. S. Nuclear Regulatory Commission Document Control Desk (w/ encl.)

J a

Enclosure to NL-92-0051

~

DETR01T EDISON - FERMI 2 DATA POINT LIBRARY REFERENCE FILE ,

TABLE OF CONTENTS NRC ERDS PARAMETER PLANT SPECIFIC POINT DESC PAGE NO.

Reactivity Control Ni POWER RNG Neutron Monitoring APRM A 1 NI POWER RNG Noutron Monitoring APRM B 2 Ni POWER RNG Neutron Monitoring APRM C 3 ,

Ni POWER RNG Noutron Monitoring APRM D 4 NI POWER RNO Neutron Monlioring APRM E 5 N1 POWER RNG Neutron Monitoring APRM F 6 NI SOURC RNO Neutron Monitoring SRM A 7 NI SOURC RNG Neutron Monitoring SRM B 8 NI SOURC RNG Neutron Monitoring SRM C 9 N1 SOURC RNG Neutron Monitoring SRM D 10 Core Cooling RLAC VES LEV RPV Water Level Flood Up Range 11 REAC VES LEV RPV Water Level Wide Range Div i 12 REAC VES LEV RPV Water Level Wide Range Div ll 13 REAC VES LEV RPV Water Level Narrow Range Div i 14 REAC VES LEV RPV Water Level Narrow Range Div 11 15 REAC VES LEV RPV Water Level Fuel Zone Div i 16 REAC VES LEV RPV Water Lovel Fu. Zono Div 11 17 MAIN FD FLOW Total Feedwater flow 18 NL North Reactor Feed Pump Flow 19 NL South Reactor Feed Pump Flow 20 RCIC FLOW RCIC Pump Flow 21 RCS Integrity RCS PRESSURE RPV Press Wide Range (PAM) A 22

, RCS PRESSURE RPV Press Wide Range (PAM) B 23 HPCI FLOW HPCI Pump Flow 24 LPCI FLOW RHR Flow Loop A 25 LPCI FLOW RHR Flow Loop B 26 CR SPRAY FL Core Spray System Flow Loop A 27 CR SPRAY FL Core Spray Syrtem Flow Loop B 28 DW FD SMP LV Drywell Floor Drain Sump Lovel 29

,d ,

J DATA POINT LIBRARY REFERENCE FILE TABLE OF CONTENTS PLANT SPECIFIC POINT DESC PAGE NO, NRC EROS PARAMETER Raoloactivity Control EFF GAS RAD SGTS Exhaust Rad 1 - Noble Gas 30 EFF GAS RAD SGTS Exhaust Rad 11 - Noble Gas 31 EFF GAS RAD Reactor Bldg Vent Rad - Noble Gas 32 EFF GAS RAD Turbino Bldg. Vent Rad - Noble Gas 33 i

t EFF GAS RAD Radwaste Bldg Vent Rad - Nobla Gas 34 CND A/E RAD SJAE Radiation Mon A 35 l

CND A/E RAD SJAE Radiation Non B 36 DW RAD Containment High Range Div i Rad Mon 37 DW RAD Containment High Range Div 11 Rad Mon 38

! MN STEAM RAD Main S+eam Line Rad C 39 Containment Conditions DW PRESS Drywell Pressure Wide Range Div i 40 DW PRESS Drywell Pressure Wide Range Div 11 41 DW PRESS Drywell Pressure Narrow Range Div i 42 l 43 i DW PRESS Drywell Pressure Narrow Range Div II DW TEMP Drywell Temp Volumetic Avg. 44 I

SP TEMP Torus Water Temperature Avg. 45 SP LEVEL Torus Water Level Wide Range .

46 SP LEVEL Torus Water Level Narrow Range Div i 47 H2 CONC Containment H2 Level Div i -48 H2 CONC Containment H2 Level Div 11 49 02 CONC Containment O2 Level Div i 50 I O2 CONC Containment 02 Level Div 11 51 l NL DrywellRorus Select Div i 52 ,

NL Drywell/ Torus Select Div 11 53 Miscellaneous Parameters l

CST LEVEL Condensate Storage Tank Level 54 WIND SPEED 10 Meter Wind Speed - 15 Min Avg. 55 i WIND SPEED 60 Meter Wind Speed 15 Min Avg. 56 l WIND DIR 10 Meter Wind Direction - 15 Min Avg. 57

! WIND DIR 60 Meter Wind Direct'on - 15 Min Avg. 58 l STAB CLASS Stabliity Class 59 l

l 1

1 i

l l J l

l 1

l l -

Page 1

{

  • DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC EROS Parameter: NI POWER RNG _.

Point ID: B11SN029 Plant Spec Point Desc.: Neutron Monitoring APRM A Generic /Cond Desc.: Nuclear Instruments. Power Range Anslog/ Digital: A Engr Units / Dig Stater.:  % ,

Engr Units Conversion: N/A Minimum instr Range: 0 Maximum Instr Range: __125 .

Zero Point

Reference:

N/A Reference Point Notes: N/A PROC er SENS: P Number of Sensors: 021 How Processed: Average Sensot Locations: Reactor Coro _

Alarm / Trip / Set Points: See unique system descrigtlon NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply T.arn-on Power Level: N/A Instrument Fal!ure Mode: Value = -999 Quality - Bad Temperature Compensation For DP Transmitters: 'N/A Level Reference Leg: N/A Unique System Desc: Alarm conditions are: High neutron flux alarm at 118% run mode,15% startup mode,3% shutdown mode and 3% refuel m od o..

i

_ _ _ _ _ . _ _ _ _ _ _ _ _ ._)

- . _ . . . .. = , . -- .- . .

Page 2; DATA POINT LIBRARY REFERENCE F;LE Date: 02/20/92-4 Reactor Unit: .FE2 _ , , _ _ _ _

Data Feeder: N/A- _ ,,.

NRC ERDS Parameter: NI POWER RNG j Point ID: B11SNO30 Plant Spec Point Desc.: Neutron Mordtoring APRM B Generic /Cond Dese.: Nuclear instruments, Power Ra. ige Analog / Digital: A Engr Units / Dig States:  %

Engr Units Convert.lon: N/A Minimum instr Range: 0 Maxinium Instr Range; 125 Zero Point

Reference:

N/A Reference Point Notes: N/A ,

PROC or SENS: .P Number of Sensors: 022 How Processed: Average Sensor Locations: Reactor Core Alarm / Trip / Set Points: See unique system description

- NI Detector Power Supply Cut-off Power Level: -N/A --

NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation 4 For DP Transmitters: 'N/A Level Reference Leg: N/A' Unique System Desc: Alarm conditions are: High neutron flux alarm' at 118% run mode,' 15% startup mode,3% shutdown mode and 3% refuel modec

~ -

Page 3 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: 32 Data Feeder: N/A _

NRC ERDS kerameter: NI POWER RNG Point ID: 811SN031 Plant Spec Point Desc.: _ Neutron Monitoring APRM C Generic /Cond Desc.: Nuclear instrume:.ts Power Range Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 125 Zero Point

Reference:

N/A Reference Point Notes: N/A _

PROC or SENS: P Number of Sensors: 021 _

How Processed: Average Sensor Locations: Reactor Core i

Alarm / Trip / Set Points: __See unique system description Ni Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power twel: N/A Instrument Failure Mode: Valuo = -999 Quality = Sad Temperature Campensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Alarm conditions are: Hi9h neutron flux alarm at 118% run mode,15% staitup mode,3% shutdown mode and 3% refuel mode.

ye

Page 4

+

- DATA POINT LIBRARY REFERENCE FILE '

Date: 02/20/92 =

f Reactor Unit: FE2 Data Feeder: N/A -

NRC EROS Parameter: N1 POWER RNG Point ID: 811SNO32 Plant Spec *oint Des:..: Neutron Monitoring APRM D 3 '

Generic /Cond Desc.: _ Nuclear instruments, Power Range Analog / Digital. A Er:gr Units /DiD States:  %

Engr Units Conversion: N/A -

Minimum instr Range: 0 Maximum instr Range: 125 Zero Point

Reference:

N/A Reference Point Notes: N/A-PROC or SEfJS: P Number of Senserrn ,022 How Processed: Average Sensor Locations: Reactor Core Alarm / Trip / Set Points: See unique system description NI Detector Power Supply Cut-off Power Level: -N/A-NI Detector Power Supply Turn-on Power Lovel: N/A instrument Failure Mode: Value = -999 - Quality - Bad , ,,,

- Temperature Compensation i

For DP Transmitters: N/A Level Reference Leg: N/A ,  ;

Unique System Desc: Alarm conditions are: High neutron flux -alarm.at 118% run .

mode.15% startup mode,3% shutdown mode and 3% refuel mode.

a g -w b' Tt'r--- m- g- p w p g s-s go

v Page 5 DATA POINT LIBRARY REFERENCE FILE Cate: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter- NI POWER RNG Point ID: B11SNO33 Plant Spec Point Desc.: _Ne ._

fon Monitoring APRM E Generic /Cond Desc.: Nuclear instruments, Power Range Analog / Digital: A Engr Units / Dig States:  % __ __ f Engr Units Conversion: N/A _

Minimstm Instr Range: 0 Maximum Instr Range: 125 Zero Point

Reference:

N/A Referenes Point Notes. N/A PROO or SENS:

~

P .

n.

Number of Sensorn 021 How Processed: Average Sensor Locations: Reactor Core Alarm / Trip / Set Points: __See unigt.a system description-N1 Detector Power Supply Cut-o'l Power Level:_ N/A _

N1 Detector Power Supply .

Turn-on Powsr Level: N/A instrument Fallure Mode: _Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A- __

Unique System Desc:  : Alarm conditions are; . High neutron flux alarm at 118% run mode,15% startup mude,3% shutdown rnode and 3% refuel mode.

s.

..: .i L- -- _ 1

Page 6 DATA POINT LIBRARY REFERF.f4CF FILE Date: 02/20/92 Fieactor Linit: FE2 Osta Feeder: N/A _ ___

NRC ERDS Parameter: NI POWER RNG Pofr t ID: B11SND34 Plant tipec Point Desc.: _ Neutron Monitoring APRM F _ ,

Generic /Cond Dese.: Nuclear Instruments, Power Range .

Analog / Digital: A _

Engr Units / Dig States:  % __

Engr Units Conversion: N/A Minimum instr Range: 0 Maximum Inst Range: __125 Zero Point

Reference:

N/A Referenca Point Notes: N/A _ ___

PROC or SENS: P Number of Sensors: 072 How Processed: Average __

Sensor Locations: Reactor Core ,_ __

Alrirm/ Trip / Set Points: ,See unique system description NI Detector Power Supply Cut-off Power Level: N/A ___

NI Detector Power Supply Turn-on Power Level: N/A _ _

instrument failure Mode: ,Value = -999 Quality = Rart Temperature Compensation For DP Transmitters: N/A _

Level Reference Leg: N/A Unique System Desc: Alarm conditions are. High neutron flux alarm at 118% run mode,15% 6tartup mndo,3% shutdown mode and 3% refuel modo,

  • Page 7 DATA POINT LIBRARY REFERENCE FILE Date: 32/20/92 Reactor Unit: FE2 Data Feeder: _N/A NRC ERDS Parameter: NI SOUR _C RNG y Point ID: C51DNO35 Plant Spec Point Desc.: Neutron Monitoring SRM A __

Generic /Cond Desc.: Nuclear Instruments, Source Range Analog / Digital: A Engr Units / Dig States: CPS _

Engr Units Conversion: fuA

Minimum Instr Range: _0.1 Maximum Instr Range: 1.0E6 Zero Point

Reference:

N/A 4- Reference Point Notes: N/A. . g PROC or SENS: S _

Number of Sensors: 001 How Proceused: Direct Reading Sensor Locatirins: See unigsystem description Alarm / Trip /Sct Points: Sea, unique system description

. NI Detector Power Supply -

Cut-off Power Levet: _N,/A N1 Detector-Power Supply Turn-on Power Level: N/A. _

instrument Failure Mode: Value = -999 Quality = Bad, Temperature Compensation -

For DP Trarismitters: N/A Level Reference Leg: N/A Unique System Dor.c: Sensor location is in reactor core variert between 18* above core center line and 30* below bottom of active fuel. Alarm and trip setpoints are ag follows; Upscale alarm = 1 x go cps Upscale trip = 2 x 10 cps-

+; instrument downscale alarm = 3 cps '

Computer input has no alarm setpoint.

, 3 m .. . . .. .______________-_U

_ _ ~

. Page 8 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A ,

NRC EROS Parameter: Ni fiOURC RNG Poir,t ID: C51Df4036 Plant Spec Point Desc.: Neutron Monitoring SRM B Generic /Cond Desc.: Nuclear instruments, Source Range Analog / Dig'tal: _

A Engr Units / Dig States: -CPS Engr Units Conversion: N/A Minimum Instr Range: 0.1 Maximum Instr Range: 1.0E6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: See unique system description Alarm / Trip / Set Points: See unique system description NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Sensor location is in reactor core varied between 18* above core centee line and 30* belcw bottom of active fuel. Alarm l and trip setpoints are ag follows:

l Upscale alarm = 1 x go cps Upscale trip = 2 x 10 cps Instrument downscale alarm = 3 cps Computer input has no alarm setpoint.

l . Page 9 DATA FOINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 -;

Data Feeder: N/A ,_

i NRC ERDS Parameter: N1 SOURC RNG e .

Point 10: C510NO37 Plant Spec Point Dese.: Neutron Monitoring SRM C _

Generic /Cond Dese,: Nuclear Instruments, Source Rango Analog / Digital: A Engr Volts / Dig States: CPS Engr Units Conversica: N/A _

Minimum Instr Range: 0.1 ,

Maximum Instr Range: 1.0E6 Zero Point

Reference:

N/A Reference Pcint Notes: N/A PROC or SENS: S Nurnber of Sensors: 001 How Processed: Direct Reading Sensor Locations: See unique system description l Alarm / Trip / Set Points: See unique system description NI Detector Power Supply Cut-off Power Level: N/A ,

NI Detector Power Supply  ;

Turn-on Power Level: N/A instrument Failure Mode: Value = -999 - Quality = Bad ,

Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Sensor location is in reactor core varied between 18" above core center line and 30' below bottom of active fuel. Alarm and trip setpoints are ag follows:

Upscale alarm = 'l x g0 cps

. Upscale trip = 2 x 10 cps Instrument downscale alarm = 3 cpa Computer input has no alarm setpoint.

- - _ . _ . . _ - _ - _ , _ , - . - - - ._-.-_,_u..--.- . _ . - . _ . , _ .

, Page 10 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 _ . ,

Data Feeder: N/A _ ,. _ ,

a NRC ERDS Parameter: NI SOURC RNG _

Point ID: C51DN038 _,_

Plant Spec Point Desc.: Neutron Monitoring SRM D Generic /Cond Dese.: Nuclear instruments Source Range Analog / Digital: A Engr Units / Dig States: CPS Engr Unita Conversion: N/A Minimum instr Range: 0.1 Maximum Instr Range: 1.0E6 d

Zero Point

Reference:

N/A Reference Polni Notes: N/A PROC of SENS: S ,

Number of Sensors: 001 How Processed: Direct head;ng Sensor locations: See unique system description __ _

Alarm / Trip / Set Points: See unique system description i

i NI Detector Power Supply Cut-off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A _

instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Referenco Leg: N/A l Unique System Desc: Sensor location is in reactor core varied between 18' ebove l

core center line and 30" below bottom of active fuel. Alarm ar'd trip setpoints are ag fcito vs:

Upscale alarn. = 1 x g0 c.ps Upscale trip = 2 x 10 cps Instrument downscale alarm = 3 cps Computer input has no alarm setpoint.

t

m. ~ . .

Pa00 11 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feener: N/A NRC ERDS Parameter; REAC VES LEV Point 10: 821SL005 Plant Spec Point Dese.: RPV Water Level Flood Up Range c

Generic /Cond Dese.: Reactor Vessel Water Level ,

AnaloD/ Digital: A Engr Units / Dig States: INCHliS Engr Units Conversion: N/A Minimurn Instr Range: 160 _

Maximum Instr Range: 560 _

Zero Point

Reference:

TAF Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: Rx Vessel Nozzle, AZ 220 , Elev. 675'-12" Alarm / Trip / Set Points: N/A NI Detector Power Supply Cut-off Power Level: _N/A _

NI Detector Power Supp!y Turn-on Powstr Level: N/A _ _

instrument Failure Mode: _

Value - -999 Quality = Bad Temperature Compensation For DP Transmitters: ,_N/A Ledel Reference Leg. WET Unique System Desc:

M E

h

. . . . _ . . . ._. . _..- _ ._ - .~ ._ ... . _ _ _- . - . . _ _ _ _ _ _.. _. _ _ -

-- e,wm..  ; m- -

m . . , , ,.m .,, , , , , . . , . ,,, ., -

Page 12 -

F e

DATA POINT LIBRARY REFERENCE FILE -

Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: REAC VES LEV _

Point ID: B21.9L006 Plant Spec Point Desc.: RPV Water Level Wide Range Div i Generic /Cond Dese.: Peactor Vessel Water Level , ,. ,

Analog / Digital: ._A Engr Units / Dig States: INCHES Engt Units Conversion: N/A ,

Minimum Instr Range: 10 _

r Maximum instr Range: 220 .;

Zero Point

Reference:

TAF __

, E.aference Point Notes: N/A-PROC or SENS: S _

I Number of Sensors: 001 * <

i- How Processed: _Djoct Reading Sensor 1.ocations: Rx Vessel Nozzle. AZ 40 ,- Eles 630'-11" *

j. Alarm / Trip / Set Points: See unigue system description NI Detector Power Supply Cut-off Power Lavel: >N/A t-NI Detector Power Supply Turn-on Power Level: N/A- __

l Instrument Failure Mode: Valuo = -999'- Ouality = Cad '

l l -Temperature Compensation For DP Transmitters: 'N/A Level Reference Leg: Wet- ,

t Unique System Desc: Plant trip and computer alarm set-points aro: High at 214*.

tow at 173.4* for both run and startup modes.

-r r- . 1 -

w--r .v 4

  • we w -m- , -- m-e er .wm- -

rww n e w - e s -ew. = E - m- .fe p. v er = y wr e- eer wre - - , = w.u "v. t e

<m. , , 4 . . , ,

Page 13 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A _

NRC ERDS Parameter: REAC VES LEV Point 10: B21DLOO7 Plant Spoc Point Desc.: RV Water Level Wide Range Div 11 i

l Generic /Cond Desc.: Reactor Vessel Water Level Analog / Digital: A l

EnDr Units / Dig States: INCFIES i

Engr Units Conversion: N/A Minimum Instr Range: 10 Maximum Instr Range: 220 Zero Point

Reference:

_TAF ,

Reference Point Notos: N/A i

PROC or SENS: S _

Number of Sensors: 001 How Processed: Direct Reading U

Sensor Locations: Rx Vessel Nozzle. AZ 220 . Elev. 630'-11*

Alarm / Trip / Set Points: See unigae system description l NI Detector Power Supply l Cut-off Power Level: N/A N1 Detector Power Supply l

Turn-nn Power Level: N/A _ _.

Instrument Failure Mode: Valee = -999 Quality u Bad ,

Temperature Compensation For DP Transmitters- N/A , ,

Level Peterence Lap: Wet Unique System Desc: Plant trip and computer alarm Jet points are: High at 214".

l Low at 173.4* for both run anC startup modes.

1

c~ . .n,~ nm n . , , , , _ , . . , , .,

Page 14 DATA POINT LIBRARY REFERENCE RLE Date: 02/20p1 Ret.: tor Unit: FE2 Data Feeder: N/A, _

NRC ERDS Parameter: REAt: VES LEV _

Point ID: C32DLO98 Plant Spec Point Desc.: RPV Water Level Narrow Range Div i Generic /Cond Dese.: Reactor Vassel Water Level _

Analog / Digital: A Er'gr Units / Dig States: i!JCHES __

Engr Unith Conversion: N/A Minimum instr Range: 160 <

Maximum Instr Range: 220 _ _ _

lero Point

Reference:

TAF Referenco Poiitt Notes: N/A _

FROC or SENS: S Number of Sensors: 008 Flow Processed: _ Direct Peading 0

Tensor Locations: Rx vessel nuzzleJN11 A). A2 40 Flev. 643'-6" Alarra/ Trip / Set Points: See unlaue systsm deseqion __

NI Detector Power Supply Cut-off Power Level: N/A l

NI Detector Power Supply l

Turn-on Power Levo 8: N/A l

instrument Failure Mode: Value = -900 Quality = Bad Temperature Compensatinn For DP Transmitters: _W/A Levei Reference Leg: W.t _ ,

Unique Eystem Desc: Feedwater system alorm conditions ce: High alarm at 202*

bwi alarm at 193*. Pbut trip and computer atarrn setpo'.nts are: High at 214" and Low at 173A",

/ If I h L;yh "

am t n. g pg g g Page 15 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 _

Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parametor: REAC VES LEV Point 10: _C32SLOO9 Plant Spec Point Desc: RPV Water Level Narrow Range Div 11 Generic /Cond Des:: Reactor Vessel Water Level Analog / Digital; _A Engr Units / Dig States: INCHES _

Engr Units Conversion: _N/A

f. Ainimum Instr Range: 160 Maximum Instr RanDt'. 220 2ero Point

Reference:

TAF Reference Polit Notos: _N/A PROC or SENJ: S Number of Sensors: 001 How Processod: Direct Reading -

0 Sensor Locations: Rx vossel nozzle. (N118). AZ 220 , Elev 643'-6*

Alarm / Trip / Set oo ints: See unique systern description Ni Detector Puwer Supply Cut-off oower Level: N/A ,

NI Detector Power Supply 1' urn-on Powe- :.4..t: N/A _ _ _

lat::s.nent Failure Mode: Value = -999 Quality = Bad Temperature compensation For DP Yransmitters: N/A Levst faderence Leg: Wet Umque System Dese: Feedwater system ularm conditions are: High alarm at 202".

Low alarm at 193*. Plant trip and computer alarm setpoints are: High ai 214* and low at 173.4*.

t f- y'g y ' g -

,j " "

% b5 *0 O f

  • 8 Y 7% -fv -(( ..._{.--

b ha k $k k u"- ]  %,4frgh (% Q h g. Mg g ,qf 4 f Qa * '" ..

Page 16 J

DATA POINT LIBRAM REFERENCE FILE .

Date: 0_2/20/92 Reactor Unit: .FE2 _

Data Feeder: fuA ..

NRC ERDS Parameter; REAC VES LEV ,

Point 10: 821D_LO10 , _ _ __ ,

s Plant Spec Point Desc.: RPV Water Level Fuel Tone Div i ~

Generic /Cond Desc: Reactor Vessel Water Leve; Analog / Digital: A _

Engr Units / Dig States: INCHES _

Engr Units Cnnversion: N/A Minimum Instr Range: -150 Maximum Instr Range: , 50 2ero Point

Reference:

TAF _

Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading -

Sensor Locations: Rx vessel nozzle, AZ 40", Elev. 650'-6" '

Alarm / Trip / Set Points: See unique system description NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Ouality = Bad

~

Instrument Failure Mode: Value = -999 Temperature Compensation i

For DP Transmitters: N/A'-

Level Reference Leg: WET _

Unique System Desc: Due to the range of this instrument, the computer would ,

provide e low reactor water level status alarm for any "on .

scale" indication, i

I

.1

, . - - , , , , . , = , . - ----- ... . .k , n.-,, - - - . , , , . , ,,,,.a.- , , . - , - . - , -

.,,: ,,.m.m.,._ 4 - .-..

Page 17 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter; REAC VES LEV Point ID: B 1DLO11 Plant Spec Point Desc.: RPV Water Level Fuel Zone Div fl Generic /Cond Desc.: Reactor Vessel Water Level Analog / Digital: A Engr Units / Dig States: INCHES Engr Units Conversion: N/A Minimum Instr Range: -150 Maximum Instr Range: 50 Zero Point

Reference:

TAF Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: Rx vessel nozzle. AZ 220 , Elev 650'- 6" Alarm / Trip / Set Points: See unique system description NI Detector Power Supply Cut-off Power Level: N/A _

NI Detector Power Supply Turn-on Power Level: N/A instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: Wet Unique System Desc: Due to the range of this instrument, the computer would provide a low reactor water level status alarm for any "on scale

  • indication.

l l

l

J., m

~

. . . g. ..-t L - . ~~.~ ~ , _ , . , , ,

Page 18 DATA oOINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 ___.

Data Feeder: ;N/A NRC ERDS Parameter: MAIN FD FLOW Point 10: C32SF250 Plant Spec Point Desc.: Total Feedwater Flow _

Generic /Cond Desc.: Feedwater Flow into the Reactor System Analog / Digital: A ,

Engr Units / Dig States: MLB/HR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum instr Range: ,17 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 002 How Processed: Sum Sensor Locations: See unique system description Alarm / Trip / Set Points: N/A NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: _

N/A Instrument Failure Mode: Value = -999 - Quality a Bad .

Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Two flow sensors are used; one for each of the two 24" main feedwater pipelines, One sensor is located in one of the pipelines at elevation 635'-3*, The other is located in the other pipeline at elevation 635'-2 5/16".

I i .T. .

.,.i ,. _ . .

.___._a_.a,o__. _ , _ __

.. -a m. . ,

Page 19 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: NL Point ID: N21SF003 .

Plant Spec Point Dese.: North Reactor Feed Pump Flow Generic /Cond Desc.: North Reactor Feed Pump Flow Analog / Digital: A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 17500 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: In 24' Pipe on Suction Side of Pump Alarm / Trip / Set Points: N/A l N1 Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A l

! Unique System Desc:

4 v, -

w ~

,....."x,c_.i.~.,.

  • ~

_ , n ,.r.n .. me.... .

. m, . . .

, , ,1,.. n , , . , , .

- Page 20 DATA POINT LIBFIARY REFERENCE FILE Date: -02/20/92

( Reactor Unit: FE2 Data Feeder: N/A NRC ERteS Parameter:. NL .

, Point ID: N21SF004  ;

Plant Spec Point Desc.: South Reactor Feed Pump Flow i

i Generic /Cond Desc.: South Reactor Feed I ;mp Flow Analog / Digital: A _

. Engr Units / Dig States
GPM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 17500 _

Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensars: 001 How Processed: Direct Reading Sensor Locations: In 24* Pipe on Suction Side of Pump' Alarm / Trip / Set Points: N/A NI Detector Power Supply Cut-off Power Level: N/A NI Detectur Power Supply Turn-on Power Level:._ N/A Insteumont Failure Mode: Value = -999 Quality = Bad

! Temperature Compensation '

, For DP Transmitters: N/A-l Level Reference Leg: N/A-

~

Unique System Desc:

i l

_=w,,,,,,...,c. - . . . , , , , , - m ,, e, - w .m .u - , - s . ~ . ...:, ,

. Pags 21 DATA POINT LIBRARY REFERENCE FILE ,,

8 Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: RCIC FLOW -

Point ID: E51SF023 Plant Spec Point Desc.: RCIC Pump Flow Generic /Cond Dese.: Reactor Core Isolation Cooling Flow Analog / Digital: A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 700 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: Pump Discharge Pipe Alarm / Trip / Set Points: N/A Ni Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply <

Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality = Bed Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A U11que System Desc:

i y

. _ .~ _

..c

. Pego 22 DATA POINT LIBRARY REFERENCE FILE  ;

Date: 02/20/92 Reactor Unit: _FE2 j i

. Data. Feeder: N/A ._. ..

l NRC ERDS Parameter: .RCS PRESSURE i

l Foint ID: 021DP020 _ __

Plant Spec Point Desc.: _ RPV Press Wide Range (PAM) A _

Generic /Cond Desc.: Reactor Coolant System Pressure Analog / Digital: _A Engr Units / Dig Stateo: ,PSIO Engr Units Conversion: N/A Minimum instr Range: ,0 _

Maximum Instr Range: 1600 l Zero Point

Reference:

N/A i

Reference Point Notes: N/A _ _

PROC or SENS: S Number of Sensors: 001

How Processed
Direct Reading Sensor Locations: Rx Vessel Norzle, AZ 40 , Elev G50'-6' Alarm / Trip / Set Points: High Alarm at 1068 PSIO I

f N1 Detector Power Supply 1

Cut-off Power Level: N/A , ,.

N1 Detector Power Supply ,

Turn-on Power Level: N/A Instrument Failure Mode: _Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: _ _

e

.w-,

-- , . . -e v , -am- ~m-e

. Page 23 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92_

Reactor Unit: FE2 Data Feede , N/A NRC EROS Parameter. RCS PRESSURE Point 10: 021DP021 Plant Spec Point Desc.: RPV Press Wide Range (PAM) D Generic /Cond Desc.: _ Reactor Coolant System Pressure ,__

Analog / Digital: A Engr Units / Dig States: PSIO Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 1500 Zero Point

Reference:

N/A Referenco Point Notest N/A PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: Rx Vessel Norrie, AZ 220 , Elev 650'-6*

Alarm / Trip / Set Points: High Alarm at 1068 PSIG , ,

NI Detector Power Supply Cut-off Power Level: _N/A N1 Detector Power Supply Turn-on Power Level: N/A __

instrument Fellure Mode: Value = -999 Ouality = Dad Temperature Compensation For DP Transmitters: N/A Level Reference f.eg: N/A Unique System Desc; _ ._

n. v , . ,- n.- - .,, , - 1- -w

_. _ _ _ . . ._.__ ~ ._._

. 4 ,, , ,

Pege 24 DATA POINT LleRARY REFERENCE FILE Date: 02/20/02 ,

Reactor Unit: F02 Data Ferder: ,N/A NRC EROS Parameter: HPCI FLOW Point ID: E41SF024 _ _

Plant Spec Point Desc.: HPCI Pump Flow ,

Generic /Cond Desc.: ,High Pressure Coolant injection Flow __

Analog / Digital: A Enct Units / Dig States: _GPM Engr Units Conversion: N/A ,

Minimum instr Range: 0 Maximum Instr Range: 6000 Zero Point

Reference:

N/A j Reference Point Note.: N/A _ ,

PROC or SENS: S. .

Number of Sensors:- 001 How Processed: Direct Reading Sensor Locations: Pump Discharge Pipo __ __

Alarm / Trip / Set Points: N/A N1 Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: ,N/A, _

insttument Failure Mode: Value = -999 Quality = Dad , _

Temperature Compensation ,

Fo." DP Transmitters: N/A Level Reference Leg: N/A ,_ _ , ,

Unique System Dese: __ _ _

e~ ...a. .

Pege 25 DATA PotNT LIBRARY REFERENf.,i FILE

)

i i

Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: LPCI FLOW Point 10: E11DF0/2 Plant Spec Point Desc.: ,RHR Flow Loop A Genetic /Cond Dese.: Low Pressure CEolant Injection Flow Analog / Digital: ,A ___

Engr Unlis/ Dig States: GPM Engr Units Conversion: N/A Minimum instr Range: 0 _

Maximum Instr Range: 28.000 Zero Point

Reference:

N/A Reference Point Notes: N/A __

PROC or SENS: S , __

Number uf Sensors: 001

How Processed
Direct Reading Sensor Locations: RHR System 24* Pipe inside Reactor Building Alarm /Trlp/ Set Points: N/A NI Detector Power Supply Cut-off Power Level: N,A

( NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality = Bad _

Temperature Compensation For DP Transmitters: N/A Level Reference Leg: _N/A l

Unique System Desc:

~ _ . ~ .

, , . n . ,, ..- ,, n- ,

, PaDe 20  ;

DATA POINT l.lBRARY REFERENCE FILE  !

Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A .,

NRC ERDS Parameter; LPCI FLOW Point ID: E11DF073 Plant Spec Point Desc.: RHR Flow Loop B Generic /Cond Desc.: Low Pressure Coolant injection Flow i

Analog / Digital: A Engr Units / Dig States: GPM Engr Units Conversion: N/A Minimum instr Range: 0 _

Maxircum Instr Range: 28.000 Zero Point

Reference:

,N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: RHR System 24* Pipe inside Reactor Building .

Alarm / Trip / Set Points: N/A N1 Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -099 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc:

l-

-.,~,-v.. . ~ , ,. . . . - ,, .n. , ,. , ; -......,.n.. .,m. - - - ~ . . . . . . , , . . - . , ,,e..,,..'. - - , ., ,.,,,,,,.n.n-,,,.,,,,,.~,,,

,a , , ,, . , ,, ,,,+,,,..o.,,.,,a,m..,, ,- ,~ , , , ,J . , , , , , , , . , . . . , , , -, , , , , ,

i ,

Page 27 1 .

DATA PDiNT Ll#RARY REFERENCE FILE l

Dato: 02/20/92 i

Reactor Unit: -

FE2 Data Feeder: N/A _ _

l ,,

NRC ERDS Parameter: CR SPRAY FL i

j Point 10: [21DF094 Plant Spec Point Desc.: Core Spray System Flow Loop _A Generic /Cond Dese.: _ Core Spray Cooling System Flow i

Analog / Digital: _A_,

Engr Units / Dig States: 0PM __

Engr Units Conversion
N/A Minimum Instr Range: _0 i

Maximum Instr Mange: 91rio Zero Point

Reference:

N/A i

fieference Point Notes: .N/A PROC or SENS: S._.

Number of Sensors: 001 How Processed: grcet ReadinD Sensor Locations: Mountad in 14" dirchargo pipe -

Alarm / Trip / Set Points: N/A NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Vatue = -999 Quellty = Bad -

. Temperature Compensation For DP Transmitters: N/A , .,

Level Reference Leg: N/A Unique System Desc:

9 eesm 9.

. . . _ _ - , , - - . - , . . ,_ _ _ _ _ . _ . _ , , . . , _ . , _ , . . . , , _ . _ . . . . . . . _ _ . . , , . . . . , . . . , , _ . , . _ _ _ _ _ . _ . , . L . ,_ _.....y_,.L,.,.,,._,_,,_., . ,__ . . . _ , , '

~ ~

  • l Page 28 l 1

DATA PDINT LIBRARY REFERENCE FILE Date: 0?/20/02 Reactor Unit: FE2 __

Data Feeder: N/A _ _

NRC EROS .'arameter: CR SPRAY FL Point ID: E21DF095 Plant Spec Point Desc.: Core Spray System Flow Loop 8 _

Generic /Cond Desc.: Core Spray Cooling System Flow Analog / Digital: _A Engr Units / Dig States: GPM Engr Units Conversion: N/A _ ,

Minimum Instr Range: 0 Maximum Instr Range: 9150 Zero Point

Reference:

N/A Reference Point Notes: _N/A PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations- Mounted in 14" discharge pipe i

Alarm / Trip / Set Points: N/A l N1 Detector Power Supply 1

Cut-off Power Level: N/A NI Detector Power Cupply Turn-on Power Level: N/A instrument Failure Mode: J'alua = -999 Quality = Dad Temperature Compensation r For DP Transmitters: N/A l

Level Reference LeR: N/A __

Unique System Desc:

l M

n.3. , ,

f..x, ._..e.,.,,.4 , m, , n . ..ie _ _ . . , . .n..., , , , ,

, ,, , , . g,

. Pago 29 l

, DATA POINT LIBRARY REFERENCE FILE .

4 l Date: 02/20/92  ;

i i

Reactor Unit: FE2 Data Feeder: ,N/A l i NRC ERDS Parameter: DW FD SMP LV '

4 l Point ID: 011DL121 l Plant Spec Point Desc.: _Drywell Floor Drain Sump _ Level ,

G$neric/Cond Desc.: Drywell floor Drain Sump Level. ,

Analog / Digital: A Engr Units / Dig States: INCHES [

i Engr Units Conversion: N/A

Minimum instr Range
0 Maximum Instr Range: 42 i Zero Point

Reference:

TNKBOT [

i Reference Point Notes: Sensor is 12* from the sumgbottom _

t

'L PROC or SENS: S ,

Number of Sensors: 001 .;

How Processed: Direct Reading Sensor Locations: Drywell Flr Drains Sump i

Alarm / Trip / Set Points: N/A I

NI Detector Power Supply l Cut-off Power Level: N/A I

l NI Detector Power Supply Turn-on Power Level: N/A , t instrument Failure Mode: Value = -999 Quality = Bad-

, Temperature Compensation l

For DP Transmitters: N/A l Level Reference Leg: Wet 1

' Unique System Desc:

4

.~,+,,e r--w -

em-7,,-p-,-c..,yw,wy-,w---wm mme,- y w,p.r, .w ,ew.,.v,, ,,.w  %,., mw-,, ve,- 4 e *-.wier,-+< ,,.,-4--++-,4 w m ,e, - , _ -.-. _ _evam-*

- ~ . - . - - .

. m . . .. m ,s, , , - 4 , , , ...,,,.

i Page 30 DATA POINT LIBRARY REFERENCE FILE t Date: 02/20/92 I tienctor Unit: FE2 -

Data Feeder: N/A 4

NRC ERDS Parameter: EFF GAS RAD i

Point ID: D11RR710 l

Plant Spec Point Dese.: SOTS Exhaust Rad 1 - Noble Gas t Generic /Cond Desc.: Radioactivity of Released Gasses Analog / Digital: A 1 Engr Units / Dig States: uCl/CC Engr Units Conversion: _N/A i

~

Minimum Instr Range: 10 uCl/CC 0 '

Maximum instr Range; 10 uCI/CC Zero Point

Reference:

N/A  ;

Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 004 Hoty Processed: See uniquo system description Sensor Locations: SOTS exh Div 1, El 690'-03*/692*-06" Alarm / Trip / Set Points: High alarm at 4.0E -6 uCl/CC l NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Ouslity = Bad Temperature Compensation For DP Transmitters: _N/A-Level Reference Leg: N/A i

Unique System Dese: Noble gas radiation is obtained from the Eberline radiation monitoring system every ten minutes. For SGTS Div I , there are 4 channels of data. The Individual channels are analyzed to determine the most accurate range. The value of that channel is stored as the selected value. l i

'I i

4,- 4 m - ew me,- * -,e , r - r w- y v~ + + - w r4%.- -

.-~..--,---.-r-- ---n,-e---.-*

  • vere----+ r e,--+ - e,== +-c'r+-r-----i,-,w--*---r+-+,--e-

e .a.I..t ,.. .. . _ _ _ . _ _ . . _ . _ _ . _ _ _ _ _ . . . _ _ . . _ . .

.~,., . . . ,s Page 31 DATA POINT LIBRARY REFERCNCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A

- NRC ERDS Parameter: EFF GAS RAD Point 10: 011RR7 7 J

Plant Spec Point Desc.: _SGTS Exhaust Rad 11 - Noble Gas Generic /Cond Desc.: Radloactivity of Released Oasses Analog / Digital: A Engr Units / Dig States: uCl/CC Engr Units Conversion: N/A Minimum Instr Range: I uCl/CC 0

Maximum instr Range: 10 oCl/CC Zero Point

Reference:

N/A Relotence Point Notes: _N /,A PROC or SENS: P , _

Number of Sensors: 004 How Processed: _See unique system description Sensor Locations: SGTS exh Div 11 El 690*-03*/692'-06"

~0 l Alarm / Trip / Set Points: High alarm at 4.0E uCl/CC N1 Detector Power Supply Cut +off Power Level: N/A _

hl Detector Power Supply Turn-on Power Level: N/A 1

Instrument Fallure Mode: Value = -999 Ouality = Bad ,

Temperature Compensation-For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Noble gas radiation is obtained from the Eberlilie radiation monitoring system every ten minutes, For SOTS Div 2, there are 4 channels of data. The individual channels are analyzed to determine the most accurate range. The value of that channel.

is stored as the selected value.

?

_ - . . . . , _ . , _ . . . . ._. . , . , _ . , _ . . , , . , _ , ,._, . _.. _.- ___,__._._, . . ~ , . , . . . . , , - . . , . , _ . . _ . _ _ _ _ . . . , . . . ,

,. 1 9

Pago 32 1

DATA POINT LIBHARY REFERENCE FILE Date: 02/20/02 l

Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: EFF GAS RAD ,

Point ID: 011RR714 ,_ _ _ l Plant Spec Point Desc.: Reactor Ridg. Vent Rad ,- Noble Gas Generic /Cond Desc.: Radioactivity of Rolessed Oasses 1 l

Analog / Digital: A l

Engr Units / Dig Ctates: uCl/CC Engr Units Conversion: N/A _ , _ _

Minimum instr Range: 10" uCl/CC Maximum Instr Range: 100 uCl/CC Zero Point

Reference:

N/A >

Reference Point Notes: N/,A PROC or SENS: P _ __

Number of Sensors: 003 _ ,

How Processed: See unique systern description Sensor Locations: Rx Bldg Exhuust EL 721' 00*/722*-06

High alarm at 6 SE

-5 uCl/CC Alarm / Trip / Set Points: ,

Ni Detector Power Supply Cut-off Power Level: N/A , ,

HI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: _N/A _

Unique System Desc: Noble gas radiation is obtained from the Eberline radiation monitoring system every ten minutes. For Reactor Bldg., there are 3 channels of data. The individual channels are analyzed to determine the most occurate range. The value of that channel is stored as the selected value,

~ .y ,, m.-_. .., m.,... ,,,,.m. , , s i l

. Page 33 DATA PDINT LlDRARY REFERENCE FILE l l

02/20/92 Date:

Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: EFF GAS RAD Point ID: _D11 AH715 Plant Spec Point Desc.: Turbine Bldg. Vent flad - Noble Gas Generic /Cond Desc.: Radioactivity of Released Cases Analog /DiDital: A Engr Units / Dig States: UCl/CC _

Engr Units Conversioni: N/A Min! mum instr Range: 10 uCl/CC Maximurn Instr Range: 10 uCl/CC Zero Point

Reference:

N/A _

Referene,s Point Notes: ,N/A PRDC or SENS: P _ ,

Number of Sent. ors: 002 How Processed; Sea unique system dese.rlgon Sensor Locations: _Turb Bldg Exh El 669'-09"/859'-10'

, Alarrv' Trip / Set Points: See units ua system description NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: NA Instrument Failure Mode: Value = -909 Quality = Bad Temperature Compensation For DP Transmitters: N/A ,

l Level Reference Leg: N/A _ _

Unique System Desc: Noble gas radiation is obtained from the Iberline fadiation monitoring system every ten minutes. For Turbine Bldg., there are 2 channels of data. The individual channels are analyrod t >

determine the most accurate range. The valua of that channel is stored as the selected value. Vgtilauon system trip / computer alarm is set at 1.7E 'J/Cl/CC.

- - - __ _ ._ __ _ .__ , . ~ . . .

_.,,. . , . ~ , . , , . . . . m .s , , ; . . . s . . ,m , .. m .m m , t wo . - - - -

. Page 34 .

DATA PDINT ilSRARY REFERENCE FILE  :

Date: 02/.20/92 Reactor Unit: JE2 _ ,_ ,,,,,_, , , , , ,

i Data Feeder: N/A ,

NRC EP.DS Parameter: EFF GAS RAD Point ID: 011RR710 Plant Spec Point Dese.: Radweste Bldg _ Vent Ran - Noble Gus

Generic /Cond Desc.
Radioactivity of ReMased Gases ,

Analog / Digital: A ,

Engr Units / Dig States: OCl/CC _ _,,

Engr Units Conversion: N/A _,

~7 Minlanum Instr Rat:De: 10 uCl/CC 4

Maximum instr Range:-

10 uCl/CC. -

Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 001 How Processed: _Sen unique gt,em descriptI,9 Sensor Locations: Adweste Bid 1Exh El 669'-06*/669'-04" Alarm / Trip / Set Points: See unique systern'descr,lgtlon,,_ _,

4 l NI Detector Power Supply i Cut-off Pnwer Livet: N/A' 7 NI Detector Power Supply Turn-on Power Level: -N/A-

, instrument Fellure Mode: Value = -909 ,

0ualhy = Dad _

i Tetnparatuto Compensation . _

For DP Transmitters: N/A ,

Level Reference Leg: N/A , _

Unique System Desc: Noble gas radletion it obtained from the Eberline radiatfor: '

monitoring system every ten minutes. For Radwkste Bldg.,

there are 2 channels of data. The individual channels are -

analyzed to da,termine the most accurate range.1The value of-

= that charinel la stored as the selected value. Ventitation system trip / computer alarm is set at 1.2E'3 uCl/CC.

^

l 9-,,v-- e w m e av - or- e- evp w w -- e v vee ~ e -- , ww e. + -w.-w.www-w.w.-e,.-+.+ii.,d.ver... e---. ,e- w 4e  % .-: +, m e aw- W-,..-e+~.re--w ww-, .~ w e a # w-e-e e 6 ev -e w r-,r

, , . , . ,, .. .w .s Pc0e 35 3

DATA POINT LlRRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feeder: _N_/A __ _ ,

NRC ERU3 Parameter: CND A/,E RAD ,

Point ID: D11DR266 Pfaret $pso Point Desc.: SJAE Radiation Mon A _

Generic /Cond Dese.: Condenser Air Elector Radioactivty ,

Analog /Digisms: A Engr Unitt/ Dig States: ,,M R/H R, Engr Units Conversion: N/A ,

Minirautn Instr Ratigv: 1.0 ,,,

Mani.mism Instr Rtinge: _1.0 E 6 Zero Point

Reference:

N/A_,, ,,

Reference Point Notes: N/A PROC of SENS: ,S ,,

Number of Sensors: 001 j How Processed: Direct Reading Sensor Locations: _0ffgas System 2.2 Min Delay Pipe Alarm / Trip / Set Points: See unique cystem description _

NI Detector Power Supply Cut-off Power Level: N/A ,_, ,,, ,,,,,,

i N8 Detector Power Supply .

Turn on Powir Level: N/A (nstrument Failuie Mode: Value = -999 Onality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A , ,,

Unique System Dese: Alarm setpoints are as follows:

Upscale trip = 750 mR/hr (Plant and computer alarm) 1 Downscale trip = 1 mR/hr (Plant alarm) 5 i High High Alarm = 1000 mR/ht (Plant aferm)

. Psgs 36 DATA PotNT LIBRARY REFERENCE FILE Date: 02/20/92___

Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: CND A/E RAD Point ID: 011DR301 Plant Spec Point Desc.: SJAE Radiation Mon B Generic /Cond Desc.: Condenser Air Elector Radioactivity Analog / Digital: A Engr Units / Dig States: MR/HR Engr Units Conversion: N/A Minimum instr Range: 1.0 Maximum Instr Range: 1.0E6 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number of Sensors: 001 l How Processed: Direct Reading 1

l Sensor Locations: Offgas System 2.2 Min Delay Pipe Alarm / Trip / Set Points: See unique system description NI Detector Power Supply Cut-off Power Level: N/A l NI Detector Pow at Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Lag: N/A l Unique System Desc: Alarm and trip setpoints are as follows:

Upscale trip = 750 mR/hr (Plant and computer alarn?

Downscale trip = 1mR/hr (Plant alarm)

High High alarm = 1000 r/hr (Plant alarm)

__ _ .._- .. _ _ _ . - _ - ._ _._ _-..~.__ _ _ - _ __._ _ __

. Pago 37 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2

,, Data Feeder: N/A NRC ERDS Parameter: DW RAD Point ID: D11DR040 Plant Spec Point Desc.: Containment High Range Div i Rad Mon Generic /Cond Dese,: Radiation Level in the Drywell Analog / Digital: A Engr Units / Dig States: R/HR-Engr Units Conversion: N/A Minimum Instr Range: 1 Maximum instr Range: 1.0E8 __

Zero Point

Reference:

_N/A Reference Point Notes: N/A j

PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: Rx Bldg inside drywell AZ 3C2 - El. 605' Alarm / Trip / Set Points: _See unique system description.

N1 Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply i Turn-on Power Level: N/A instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Alarm setpoints are as follows:

Alert = 500 R/HR (Plant alarm)

High Radiation = 1000 R/HR (Plant and computer alarm) 1 l

.... .4,. ..._ . 4 , , ,

~

. Page 38 l DATA POINT Ll8RARY REFERENCE FILE Date: 02/20/92_

Reactor Unit: FE2 f

Data Feeder: N/A

. NRC ERDS Parameter: DW RAD Point 10: D11DR163 Plant Spec Point Desc.: Containment High Range Div 11 Rad Mon Generic /Cond Desc.: Radiation Level in the Drywell ,

Analog / Digital: A Engr Units / Dig States: R/HR Engr Units Conversion: N/A Minimum lustr Range: 1 Maximum Instr Range: 1.0E 8 Zero Point

Reference:

N/A Reference Point Notes: N/A PRDC or SENS: S Number of Sensors: 001 How Processed: Direct Reading 0

Sensor 1.ocations: El 605'-0* at AZ 125 Alarm / Trip / Set Points: See unique system description NI Detector Power Supply Cut-off Power Level: N/A I

i N1 Detector Power Supply Turn-on Power Level: N/A instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: Alarm setpoints are as follows:

Alert = 500 R/HR (Plant alarm)

High Radiation = 1000 R/HR (Plant and computer alarm)'

g%... -. ..., s.y , , - - , ,,g,-...y.y....,,, ....__..m ...p_,, 4,... , ,. . , . , ...,y,m.,.,.- p.m. w.~ , ,r.,,,,%,,. , ,

" ~~~ ~~^ ~ ~~~

,. . . . , . . . . . , , _ . . . J T . .. ~

PaDe 39  ;

I DATA PDINT LlDRARY REFERENCE FILE I

Date: 0_2_/20/02 I Reactor Unit: JE_2 Data Feeder: 4/A , ,,,, l l NRC ERDS Parameter: MN STEAM RAD i Point ID: D11DR039 l l Plant Spec Point Desc.: Main Steam Line_ Rad C ,

Generic /Cond Desc.: Radja, tion Level of the Main Steam Line Analog / Digital: _A _

Engr Units / Dig States: MR/Hr Engr Units Conversion: N/A Minimum instr Range: 1 ,

Maximum instr Range: 1.0E6 _

Zero Point

Reference:

N/A l Reference Point Notes: N/A l

PROC or SENS: S l

Number of Sensors: 001 I How Processed: Direct Reading Sensor Locations: 613'-6* Reactor Btdg G-4 (Steam Tunnel) l Alarm / Trip / Set Points: See unique system description i NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument F611ure Mode: Value - -999 Quality - Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: High radiation level alarm is 2800 mR/hr. Instrument failure alarm is 1 mR/hr downscale. Trip setpoint is 3000 mR/hr.

Computer input has no alarm setpoint.

.. = _ ~ - . . . - - ~ . - .

. .nm .. , ,. , , , . - - , , . . , .,. . . u,,,,

. PaDe 40 DATA POINT LIBRARY REFERl!NCE FILE Date: 02/20/92 Reactor Unit: FE2 _

Data Fender: _N /,,A, _ ,,,_ .,

NRC ERDS Parameter: DW PRESS , ,,, _,_

Point 10: T60DP_0,97 _ , , , , , _ _ _

Plant Spec Point Desc.: Drywell Pressure Wide Range Div i I

Generic /Cond Desc.: ,Drywell Pressure Analog / Digital: A Engr Units / Dig States: PSIO Engt Units Conversion: JJ/A_

Minimum Instr Range: 0 _ _

Maximum instr Range: 250 Zero Point

Reference:

N/A Reference Point Notes: N/A_ ,,

PRDC or SENS: S i

Number of Sensors: ,,001 How Processeu: Direct Readi,nj Sensor Locatluns: Drywell penet AZ 330U, Elev. 630'-3*

Alarm / Trip / Set Points: N/A _

NI Detector Power Supply Cut-of t Power Level: N/A l

Ni Cetector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality = Bad i

l Temperature Compensation For DP Transmitters: N/A-Level Reference Leg: N/A Unique System Desc:  ;

. .-. -. . . -...-- . . . . _ . . . . ..- . . - . ~ - - . . - - . . . . . ..-.. . - -.- - - - . - . . ~ ..-.

. . . . . , . . . , ..m

....-, , , , , , ,. ,.,a -,s.-

,-,,.,...,mm.,- , , . -.s...< m.,_ --

e P

. Page 41

?

DATA POINT LIBRtHY REFERENCE FILE Date: 0,2,/2_9/92 Reactor Unit: FL , _ , , _ ,

t l

Data Feeder: JJ/A ,,,,_ ,_ _. , _ , . . _

NRC ERDS Parsmeter, DW PRESS . _ _ _ _ ,_ _

Point 10: T50DP090 , _,,,,_ , , _ , ,

Plant Spec Point Dese.: prywell Pressu_re Wide Ran2e Civ 11_

Genetic /Comi Dese,: _Drywell Pressure _ _ _ ,

! Analog /Digitti: .A_ _

5 l Engr Units / Dig Statow PSIG Engr Units Converelon: N/A , , , , , , , , , , _ _ , __, , ,

eilnimum instr Range: 0 Maximum Instr Range: 250 Zero Point

Reference:

N/A Reference Point Notes: N/A I

l PROC or S2NS: S Number of Sensors: 001 "

i How Processed: Direct Reading o

Sensor Locations: Drywell Panet AZ g ,-30', Elev. 630'-3*

Alarm / Trip / Sat Points: N/A ,,_

Ni Detector Power Supply l ,

Cut-off Power Level: N/A _

NI Detector Power Supply r Turn-on Power Level: N/A , , , _

instrument Failure Mode: Value = -999 Quality = Bad _

Temperatura Compensation For DP Transmitters: N//A -

Level Reference Leg: N/A Unique System Dese:

\.

  • ,*w.r. - . . ., - ,,.7,,yr.,w--- --.-wr.--..,. ...<r -+,~..w. .

..y..r,,-w.- .-<.,+.,me.e,.-i,< ,r y v v~.e..-.e.,,.,w.<- - e,-.

. 6

. Page 92 DATA POINT LIBftARY HEFER!!NCE Fil.E f

Date: 02/20/02 ,

Reactor Unit: FE2 _,_ _, .

Data Feeder: 2/A_ _, .

. NRC ERDS Paramater: DW PRESS s Po!nt ID: ._TS,0DP099 __

Plant Spe(. Polt:t Desc.: _Drywell Pressure Narrow Range Dh I Generi:iCond Dese.: Drywell Pressurn  ;

Analog /Dirital: A ,

Engr Units / Dig States- PSIG Engr Unitt Conversion: ,N_/ A i

Minimum Instr Range: -5.00 -

A4aximum Instr Nange: _5;0_0 I Iero Point Referen( a: N/A , ,,

Refarence I olne Notes: N/A PROC or f. ENS: S __

Number of Sensors: 01 ,

y How Processed: , Direct Reading 0

C,ensor Locatienes Elev. 630' 3',81 Aalmuth 330 ,

Alarm / Trip / Set Points: High/Loar alarm = 160/-0.68 PSIG _ __

NI Detector Power Supply l

Cut-off Power Level: J4/A .

N Detector Power Supply -

l- Turn-on Potter Leve': N/A i instrument Failure MorJe: ,Value = 999 Ouality _

Bad _

Temperature Compensation for DP Transmitters: N/A __ , _

l Level Reference Leg: N/A __ __

l Unique System Dese: __ _ _

4-eeusands Gutess MM

'. j

. meme endet -.

1 . . . . .,... . . _ _ . . . _ , _ _ _ - . . . , . . . . . - , _ _ _ , - . _ . - . _ . . , . _ . . . . . . . . ._. -.. ......;..~.,..,_, . ..- .._. - . , , . ..

_ . . _ - . _ -._.~ . . . _ _ _ . _ . . -. ._ _ _.._ _ _ - _ _ _ - - _

PaDe 43 l

i i DATA POINT LlDRARY HEFERENCE FILE Date: 02/20/92 Henctor Uriit: FE2 Data Feerfer: N/A NRC ERDS Parameter; DW PRESS l,

Point 10: T50DP100 l Plant Spec Point Dese,? Dr,ywell Pressure Narrow Range Div 11 Generic /Cond Desc.: ,Drywell Pressure Analog / Digital: A _

I Engr Units / Dig States: PStG l Engr Units Conversion: N/A Minimum instr Range: ,-S.0 Maximum instr Range: ___5.0 l Zero Point

Reference:

N/A _

P.afetence Point Notes: N/A l PRDC ct SENS: _S.

l l Nurnber of Sensorst 001 ~

l l

liow Processed: Direct Readinj Drywell Penet. AZ 187U -30', Elev. 630'-3" i~ stor L%edons:

i N -m/ Trip / Set Points: High/ Low Alarm = 1.68/-0.68 PSIG l

l

', Detector Power Supply cut-off Power Levet: ,N/A -

NI Detector Power Supply ,_

Turn-on Power Level: N/A _

l l

Instru6, Failure Mode: ,Value ' -999 Ouslity = Bad i

Trny<.t -

  • Compenselion For D' asmitters: N/A l Level %:ference Leg: ,N/A l

l Unique System Desc:

4--

m.

r- - e m m-- -~ e - w -- g ,-- e- --ve--

e. . . .

. Page 44 r

DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter. _DW TEMP Point ID: T47CT206 Plant Spec Point Desc.: Drywell Temp Volumetric Avg.

Generic /Cond Desc.: Drywell Temperature _

Analog /D101.al: _A Engr Units / Dig States: DEGF Engr Units Conversion: N/A ,_.

Minimum Instr Range: 0 Maximum Instr Range: ,450 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 028 How Processed: Volumetric Weighted AveraDe of 28 inputs Sensor Locations: See uniqac System Description Alarm / Trip / Set Points: High Alarm at 145 F NI Detector Power Supply Cut-off Power Level: N/A N1 Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 jhtality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: There are a total of 28 thermocouples. 4 at elevation 590',10 at elev 597',4 at elev 621'; 4 at elev 647',4 at elev 662' and 2 at elev 665' l

l t

,, . . , , c .~..

d PO0e 45 DATA PDINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 ,

Data Feeder: N/A NRC EROS Parameter: SP TEMP Point ID: _T23CT005 Plant Spec Point Desc.: To~us Water Temperature Avg.

Generic /Cond Desc.: _ Suppression Pool Temperature _

Analog / Digital: .A Engr Units / Dig States: DEGF Engr Units Converaion: N/A Minimum Instr Range: 60 Maximum Instr Range: _260 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 008 How Processed: Average of 8 healthy input is calculated l

Sensor Locations: See unique system description Alarm / Trip / Set Points: High Alarm at 95 F NI Detector Power Supply

, Cut-off Power Level: N/A l

i NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: plue = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A 1

l Unique System Desc: There are 8 thermecouples located on the same elevation (556'-01") but at different lateral locations in the torus as0 0 0 0 0 follows: 22 ,67 ,112 ,157 ,202 ,247 ,292 and 337 . 0 Valldity of torus water temperature is partially determined by torus water level. If the water level is below the level of tha torus T/C, this data is. flagged as bad.

, Po00 46 DATA POINT LIBRARY REFERENCE FILC Date: 02/20/92 l

Reactor Unit: FE2 j

Data Feeder: N/A NRC ERDS Parameter: SP LEVEL Point ID: T5fiOL110 Plant Spec Point Desc.: Torus Watst Level Wide Range Generic /Cond Desc.: . Suppression Pool Water Level Analog / Digital: A Engr Units / Dig States: INCHES Engr Units Conversion: N/A Minimum Instr Range: -144 Maximum Instr Range: 56 Zero Point

Reference:

_COMPLX Reference Point Notes: _ Normal Wtr Lvl is 0* from torus CL PRO * 't S' NS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: Rx Bldg Sub Basement .

Alarm / Trip / Set Points: N/A N1 Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality - Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: WET Unique Systet.4 Dese: Inside diameter of torus is 30'6" Zero point reference is 14'-6* of torus water level Center line of torus is at elev 557'9*

l

~ ~~ ~ ^ ~ ~~ ~ - - ~ ~ ~ ~

.- ~ . . , . . . . , . ,

,,--,;....~ ,-

. Pago 47 DATA POINT LIBRARY REFERENCE FILE Date: 02/20]U2_

Reactor Unit: FE2 _

Data Feeder: N/A _

NRC ERDS Parameter; _S P_,L_EV E L Point ID: E41DL120 Plant Spec Point Desc.: Torus Water Level Narrow RanDe Div 1 Generic /Cond Desc.: Suppression Pool Water Level Analog / Digital: A r

Engr Units / Dig States: INCHES Engr Units Conversion: N/A Minimum instr Range: -10 Maximum Instr Range: 10 Zero Point

Reference:

COMPLX Reference Point Notes: See unique system description PROC or SENS: S Number of Sensors: 001 How Processed: Direct headinj Sensor Locations: Elev. 551' 4" on torus Alarm / Trip / Set Points: , Low alarm at -2* Hit,h alerm at +2*

NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Fallure Mode: Value = -999 Quality = Bad l Temperature Compensation I

For DP Transmitters: Y Level Reference Leg: Wet Unique System Desc: Inside diameter of torus is 30'6".

Zero Point Reference is 14'6' of Torus water level Center line of Torus is at elev. 55T9'

.. - ~-

.m._ _ . _ _ . . . _ _ _ _ . _ _ _ . _ . _ . . _ __ _ ____ . _ _._-_..__.__ _ . _ _ . _ .___._. _ _

-- - - 4 . . . . . .. s _ . . . , ,, 1 PaDe 68 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92

Reactor Un'.<: F52 Data Feeder: N/A NRC ERDS Parameter; H2 CONC  :

Point 10: i JL255 Plant Spec Point Desc.: Containment H2 Level Div i l

Generic /Cond Desc.: Drywell or Torus Hydrogen Concentratlog Analog / Digital: _A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 30 Zero Point

Reference:

,,N/A _,

Reference Point Notes: N/A ,

PROC or SENS: S j Number of Sensors: 001 How Processed: Direct Reading Sensor Locationst 2nd Flr Rx Bldg instrument tack Alarm / Trip / Set Points: High Alarm at 1%

NI Detector Power Supply Cut-off Power Level: _N/A NI Detector Power supply Turn-on Power Level: N/A i

j instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation -

For DP Transmitters: N/A' Level Reference Leg: N/A _

Unique Systera Desc:

l

, _ - . . . . _ . . _ . _ . . _ , _ . _ . - . , _ , . . _ _ _ . _ _ - _ _ _ _ _ _ _ _ _ , _ . _ . . _ . _ , . , . . _ ~ . . . . . . _ _ _ _ _ . _ _ . _ .

2 i

. Pogo 49 i

DATA POINT LIBRARY REFERENCE FILE ,

4 Date: 02/20/92__ ,

Reactor Unit: FE2 .

! Data feeder: N/A i

s NRC ERDS Parameter: H2 00NC _

i Point ID: T50DL293 l

Plant Spec Point Dese.: Containment H2 Level Div 11 Generic /Cond Desc.: Drywell or Torus Hydrogen Concentration Analog / Digital: A ,

1 Engr Units / Dig States:  %

i

Engr Units Conversion: _N/A Minimum instr Range: 0  ;

Maximum Instr Range: 30 ______

Zero Point

Reference:

N/A Reference Point Notes: N/A

PROC or SENS
S Number of Sensors: 001 How Processed: Direct Reading I

I Sensor Locations: 3rd Fir Rx Bldg instrument rack-Alarm / Trip / Set Points: High Alarm at 1%

NI Detector Power Supply l Cut-off Power Level: N/A l NI Detector Power Supply j Turn-on Power Level: N/A l

Quality = Bad l' Instrument Failure Mode: Value = -999 Temperature Compensation ,

For DP Transmitters: N/A .

Level Reference Leg: N/A Unique System Desc:

9

-v.w--.. ..m , ,#..%,,.--e,w-,-,-- ,, ..-,-,,,,--4 -4,,y--+,,g,,,,,-,,v.#,-,,-- ,r.y,-,--, , . ,wmp.y.y,- .

wv. yw,v.-,, ..m.-. ,r,=, ,,.ge-ww,, -.,e,--,, , , , ,-n v .,g-g-, mw w.r,

.4 9

. Page 50 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 ,

Reactor Unit: FE2 _

Dita Feeder: N/A NRC ERDS Parameter; O2 CONC _

Point ID: T50CL188 Plant Spec Point Desc.: _

Containment 02 Level Div I Oonetic/Cond Desc.: Drywell or Torus Oxygen Concentration Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 _

Maximum Instr Range: 30 Zero Point

Reference:

N/A Referenci

  • oint Notes: N/A PROC or SENS: P Number of Sensoa 003 How Processed: See Unique System Description Sensor Lor:mtions: See Unique System Description Alarm / Trip / Set Points: High Alarm at 4% O2 Level (Run Mode)

Ni Detector Power Supply Cut-off Power Lvvel: !J/A NI Detector Power Supply

  • Turn-on Power Level: N/A instrument Failure Mode: ,Value = -999 Ouality = Bad Temperature Compensation For DF Transmitters: N/A Level Reference Leg: N/A Unique System Desc: This is a calculated point based on the following inputs: 1.

Range select 2. 02 level 10% vol 3. 02 Level 30% vol, if the value of range select is 1, then the wide range has been selecto1 and the output point is set to wide range (30%) point.

The narrow range point is not scanned. If the value of range select is not 1, then the narrow range has been selected and the output point is set to narrow range (10%) point. The wide range pc' int is not scanned

~^ ~^ =

, _ ~ ^c ... ,y,_,,,

Page 51 DATA POINT LIBRARY REFERENCE FILE

(

Date: ,

02/20/92 ,

Reactor Unit: FE2 __

Data Feeder: N/A NRC ERDS Parameter: 02 CONC Point ID: T50CL189 Plant Spec Point Desc.: Containment 02 Level Div 11 Generic /Cond Desc.: Drywell or Torus Oxygen Concentration _

Analog / Digital: A Engr Units / Dig States:  %

Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum instr Range: 30 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 003 _

How Processed: See unique system description Sensor Locations: See unique system description Alarm / Trip / Set Points: High Alarm at 4% 0, Level (Run Mode)

N1 Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A _

Level Reference Leg: N/A _

Unique System Dese: This is a c.alculated point based on the following inputs. 1.

Range select; 2. 0 2 level 10% vol; 3. O 2 level 30% vol. If the value of range select is 1, then the wide range has been selected and the output point is set to \ tide range (30%) point.

The narrow range is not scanned. If the value of the range select is not 1, then the narrow range has been selected and the output point is set to narrow range (10%) point.

. Paga 52 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92_

Reactor Unit: FE2 * ,

Data Feeder: N/A NRC ERDS Parameter: NL Point 10: T50DC270 Plant Spec Point Desc.: Drywell/ Torus Select Div I Generic /Cond Desc.: Drywell/ Torus Select Div I Analog / Digital: D Engr Units / Dig States: On = Drywell Engr Units Conversion: N/A Minimum instr Range: N/A Maximum Instr Range: N/A Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S .

Number of Sensors: 001 _

How Processed: See unique system descrgtion Sensor Locetions: N/A Alarm / Trip / Set Points: N/A NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A _

Level deference Leg: N/A _

Unique System Dese: This digital signal is provided by a switch contact. When the contact is closed, the drywell is selected when the contact is -

opened, the t' ras is setected. This signal is used to salect the oxygen and hydrogen sensor location.

W - . . . . . . . . . . . . . . . . . . .

, Page 53 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 .

Reactor Unit: , FE2 Data Feeder: N/A NRC ERDS Parameter; NL Point ID: T50DC311 Plant Spec Point Desc.: Drywell/ Torus Select Div ll Generic /Cor.d Desc.: Drywell/ Torus Select Div II Analog / Digital: D Engr Units /DiD States: On = Drywell Engr Units Conversion: N/A Minimum Instr Range: N/A Maximum instr Range: N/A Zero Point

Reference:

N/A

. Reference Point Notes: N/A I PROC or SENS: S l

Ntimber of Sensors: 001 How Processed: See unique system description Sensor Locations: N/A Alarm / Trip / Set Points: N/A NI Detector Power Supply Cut-off Power Level: N/A ,

Ni Detector Power Supply Turn-on Power Level: N/A ,

Instrument Failure Mode: Value = -938 Quality = Bad Temperature Compens? tion For DP Transmitters: N/A Level Reference Leg: N/A Unique System Dese: This digital signal is provided by a switch contact. When the contact is closed, the drywell is selected. When the contact is opened, the torus is selected. This signal is used to select the oxygen and hydrogen sensor location.

. Page 54 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 ,

Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: CST LEVEL Point ID: P11DLO71 Plant Spec Point Desc.: _ Condensate Storage Tank Level Generic /Cond Desc.: Condensate Storage Tank Level Analog / Digital: A Engr Units / Dig States: FEET Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 35 Zero Point Referen::c: TNKBOT Reference Point Notes: See unique s'/ stem description PROC or SENS: S Number of Sensors: 001 How Processed: Direct Reading Sensor Locations: 2 Feet Above the Tank Bottom Alarm / Trip / Set Points: See unique system dascription NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A ,

Level Reference Leg: N/A Unique System Dese: Level instrumentation uses bourdon tube type with a range of 0-14.2 PSIG for a 0-35 feet level. High level setpoint is 12.14 PSIG (30 Feet). Lcw level setpoint is 4.12 PSIG (10 Feet).

Computer input has no alarm setpoint.

_ ... .. . .._ . .. _ .,_ .... .... ., _ ~ m._ _. . .m.,~ , , , , ,

Pags 55 DATA POINT LIBRARY REFERENCE FILE Date; 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: WIND SPEED Point ID: D40MS064 Plant Spec Point Desc.: 10 Meter Wind Speed - 15 Min Avg Generic /Cond Desc.: Wind Speed at the Reactor Site Analog / Digital: A Engr Units / Dig States: MPH Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum instr Range: 100 Zero Point

Reference:

N/A ..

Reference Point Notes: N/A PROC or SENS: P Number of Sensors: 002 How Processed: See unique system description Sensor Locations: 10 Meters above ground at 60 meter tower ,

Alarm / Trip / Set Points: None NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation l For DP Transmitters: N/A i

, Level Reference Leg: N/A l

Unique System Desc: The output of the wind speed transmitter is transmitted to the specific signal translator located in the instrument shelter at the base of the tower. The voltage output from the signal translator is transmitted to the Meteorological Data Acquisition computer located in the computer room. The Met computer,

- among its other functions, converts the sensor signal to l; appropriate engineering units and communicates with the Emergency Response Inf6rmation System (FRIS) computer.

l These data received by ERIS is then passed on to .ERDS.

1

- . . - - - . ....a. - .. . . . = . - . .,. - - . . , ,

. , , ~ . . .,_.,,s

..n-.;.,...n,,,

.. Pegs 56 DATA POINT LIBRARY REFERENCE FILE Date: 02/20/92 Reactor Unit: FE2 Data Feeder: N/A NRC ERDS Parameter: WIND SPEED Point ID: D40MS065 Plant Spec Point Desc.: 60 Meter Wind Speed - 15 Min Avg.

Generic /Cond Dese,: Wind Speed at the Reactor Site

, Analog / Digital: A l

Engr Units /Diji States: MPH Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 100 Zero Point

Reference:

N/A l

Refer nee Point Notes: -N/A PROC or SENS: P Number of Sonsors: 002 How Processed: See unique systnm description.

Sensor Locations: 60 Meters above ground at 60 meter tower Alarm / Trip / Set Points: None

- NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A Instrument Failure Mode: Value = -999 ' Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: The output of the wind speed transmitter is transmitted to the specific signal translator located in the instrument shelter at the base of the tower. The= voltage output from the signal translator is transmitted to the Meteorological Data Acquisition computer located in the computer room. The Met computer, among its other functions, converts the sensor signal to appropriate engineering units and communicates with the Emergency-Response Information System (ERIS) computer.

These' data received by ERIS is then passed on to ERDS.

. _ . . . . . . . , - . . . _ . . - _ - , , . w, a 1 .,e m ete i ,. ., .

i .* Pags 57-

+

DATA POINT LIBRARY REFERENCE FILE I Date: 02/20/92 4

Reactor Unit: FE2 Data feeder: N/A NRC ERDS Parameter: WIND DIR Point ID: D40MS069 i

Plant Spec Point Dese.: 10 Meter Wind Direction - 15 Min. Avg Generic /Cond Desc.: Wind Direction at the Reactor Site Analog / Digital: A Engr Units / Dig States: DEOFR Engr Units Conversion: N/A Minimum Instr Range: 0 Maximum Instr Range: 360 Zero Point

Reference:

N/A Reference Point Notes: N/A i PNOC or SENS: P Number of Sensors: _002 How Processed: See unique system description.

Sensor Locations: 10 Meters above ground at 60 Meter Tower Alarm / Trip / Set Points: None NI Detector Power Supply Cut-off Power Level: N/A '

NI Detector Power Supply Turn-on Power. Level: N/A-Instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A Unique System Desc: The output of the wind direction transmitter is transmitted to the specific signal translator located in the instrument shelter.

at the base of the tower,- The voltage output from the signal translator is transmitted to the Met computer located in the -

computer room. The Met computer, among its other functions, .

converts the sensor signal to appropriate engineering units and -

communicates with the Emergency Response Information-System (ERIS) computer. These' data received by ERIS is then passed on to ERDS. Car'dinal directions are: North = 0 or 360 ,

East = 90 . South = 180 , West = 270 U

- - - . . - . . . . . . . . - . .. - =

. _ . - . . . . _ ., _ _ ,s, . ,.m. m s , m ,. m s Page 58 DATA POINT LIBRARY REFERENCE FILE r  :

Date: 02/20/92 .

Reactor Unit: FE2 i

Data Feeder: N/A

, NRC ERDS Parameten WIND DlR ,

! Point ID: D40MS070 l

Plant Spec Point Desc.: 60 Meter Wind Direction-15 Min Avg i

Generic /Cond Desc.: Wind Direction at the Reactor S!te l

Arialog/ Digital: A I

l Engr Units / Dig States: __ DEGFR l Engr Units Conversion: N/A i

( Minimum Instr Range: 0 Maximum Instr riange: 360 Zero Point

Reference:

_N/A Reference Point Notes: N/A-PROC or SENS: P i

Number of Sensors: 00t I How Processed: See unique system description l

Sensor Locations: 60 Meters above ground at 60 meter tower l A! arm / Trip / Set Points: None NI Detector Power Supply Cut-off Power Level: __N/A NI Detector Power Supply Turn-on Power Level: N/A l

Instrument Failure Mode: Value = -999 Quality = Bad Temperature Compensation For DP Transmitters: N/A-Level Reference Leg: N/A Unique System Desc: The output of the wind direction transmitter is sent to the specific signal translator located in the instrument shelter at the base of the tower. The voltage output from the signal translator is transmitted to the Met computer located in the computer room. The Met computer, among its other functions,

- converts the sensor _ signal to appropriate engineering units and communicates with the Emergency Response information System (ERIS) computer. .These data received by ERIS is then ,

passed on0 to ERDS.-' Cardinal directions are: .. North = 0 or 360 ,

East = 90 . South = 1800. West = 2700.

. ._ _.. - . ,_ . _ . _ . _ , _ . . . _ . ~ . . _ - _ . ,

.. -. .. .- .. - . ... . .. . .- - . . ~ . . - . . . _ - . . . . - . . . . . . .

_-,_...._..._.....-r... >

> m '

v * )

,: ,J Page 59 l

, .* i e l DATA POINT LIBRARY REFERENCE FILE

Date
02/20/92 ~

Reactor Unit: FE2 l

, Data Feeder: N/A NRC ERDS Parameter: STAP CLASS 4 Point 10: _D40MB168 Plant Spec Point Desc.: Stability Class Generic /Cond Dese.: Mr Stability at the Reactor Site Analog / Digital: A Engr Units / Dig States: STABI l Engr Units Conversion: See unique system description i

Minimum Instr Range: 1 Maximum Instr Range: 7 Zero Point

Reference:

N/A ~

Reference Point Notes: N/A PROC or sells: P

,- Number of Sensors: 002 l

How Processed: See unique system description Sensor Locations: See unique system description Alarm / Trip / Set Points: N/A NI Detector Power Supply Cut-off Power Level: N/A NI Detector Power Supply Turn-on Power Level: N/A=

Instrument Failure Mode: Value = -999 - Quality = Bad Temperature Compensation For DP Transmitters: N/A Level Reference Leg: N/A i Unique System Desc: Measured using differential temperature between 10 & 60

! meters. The stability classification is per Reg. Guide 1.21f Table 48.

t