Am entrtfu ting September 5, 2024 ACO 24-0075 ATTN: Document Control Desk John W. Lubinski, Director Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Laura Dudes, Regional Administrator U.S. Nuclear Regulatory Commission, Region II Marquis One Tower 245 Peachtree Center Ave. NE, Suite 1200 Atlanta, GA 30303-1200 American Centrifuge Plant; Docket Number 70-7004; License Number SNM-2011 Correction to Previous Submittal of 10 Code of Federal Regulations 70.59 Effluent Reporting

Dear John Lubinski and Laura Dudes:

The purpose of this letter is to submit corrected pages for American Centrifuge Operating, LLC's (ACO) 10 Code of Federal Regulations 70.59 effluent report previously submitted on August 29, 2024 (Reference 1). Specifically, two conservative errors were identified during further internal reviews of the sampling data relating to the total estimated exposure. Enclosure 1 contains corrected pages 1 and 2 for Enclosure 1 of ACO 24-0069 and are shown with a revision bar in the right-hand margin.

If you have any questions regarding this matter, please coritact Stephen Howie, Radiation Protection Manager at (740) 897-2347.

Enclosure:

As Stated Sincerely,

~fl~U Kelly L. Fitch Regulatory Manager American Centrifuge Operating, LLC 3930 U.S. Route 23 South - P.O. Box 628 Piketon, OH 45661

~f:43 M SS 20 p__~. N02-NM S S

~j 'f'\ - \'

John Lubinski and Laura Dudes September 5, 2024 ACO 24-0075, Page 2

Reference:

I

1. ACO 24-0069 from K.L. Fitch to J.W. Lubinski (NRC HQ) and L. Dudes (NRC RII) regarding Submittal of 10 Code of Federal Regulations 70.59 Effluent Reporting, dated August 29, 2024 cc:

C. Blanton, DOE Idaho J. Downs, NRC HQ Y. Faraz, NRC HQ A. Ford, DOE Idaho J. Hutson, Contractor J. Lingard, DOE Idaho L. Pitts, NRC Region /II M. Reim, DOE-NE D. Woodyatt, NRC HQ of ACO 24-0075 Corrected Pages for ACO's Effluent Reporting for the Period of January 1 through June 30, 2024 Previously Submitted Under ACO 24-0069 Dated August 29, 2024 Information Contained Within Does Not Contain Export Controlled Information Reviewer: Lori A. Hawk/ ACO Date: 09/05/2024 ACO 24-0069 Page 1 of 3 American Centrifuge Plant (ACP)-High-Assay Low-Enriched Uranium (HALEU) Demonstration Cascade Reporting Period of January 1 through June 30, 2024 Overview of Results During the reporting period of January 1, 2024, to June 30, 2024, enrichment operations for American Centrifuge Operating, LLC (ACO) occurred twice between March and June 2024.

Inventory removal or other maintenance activities were ongoing during the dates that enrichment operations were not occurring.

The information provided within this report provides the total release data, specifically uranium and technetium (if any) amounts and concentrations for ACO gaseous and liquid effluents. There were no quantities of radioactive materials released during the reporting period that are significantly above ACO's design objectives previously reviewed as part of the licensing action.

ACO's total estimated exposure is 1.6 E -05 millirem (mrem). Doses were determined using CAP88 Version 4.1.1 for readings obtained during the reporting period.

Additionally, as requested by U.S. Nuclear Regulatory Commission staff in June 2024, the Hydrogen Fluoride (HF) concentration for the maximumly exposed individual is also provided within this report.

The total release data for the reporting period of January 1 through June 30, 2024, is as follows:

Radionuclide Total Gaseous Releases Total Liquid Releases Unit of Measure 234u 8.94 E-03 1.30 E -01 milliCurie (mCi) 23su 1.lOE-03 5.47 E -03 mCi 23su 8.75 E-03 9.08 E -02 mCi 99Tc 0.00 E +00 0.00 E +00 mCi 99Tc lab results were undetectable.

As shown above, the total release data is well below ACO's As Low As Reasonably Achievable goals for both airborne and waterborne radioactive releases as committed within Chapter 9 ofLA-3605-0001, License Application for the American Centrifuge Plant.

\

Airborne Releases Monitored Vents

  • Enclosure 1 ACO 24-0069 Page 2 of3 The estimate of public dose due to gaseous effluents over the previous year is 1.6 E -05 mrem.

Combined ACP Monitored Vents Total Stack Flow (cubic meter fm3l) 8.28 E +05 Minimmp

..I Percent

?

Concentration. :,

Detectable

.Maximum..

  • /

microcuries per.'

Estimated Activity

, Potential ****

,, ~," '

milliliter Error

Release

  • Concentrat c11ci/m*n.. **

',/',,.,,

ion (MPC) *

, Radionuclid~ *.

µCi/ml*

    • **, µCi/ml.

mCi 234U (boundary) 1.04 E -18 8.53 E-20 3.61 E -19 0.000035%

235U (boundary) 1.29 E -19 1.41 E -20 6.94 E-20 0.000004%

238U (boundary) 1.02 E -18 1.08 E -19 1.20 E -19 0.000034%

99Tc (boundary) 0.00 E 0 0.00 E+00 0.00 E +00 0.00 E 0 99Tc lab results were undetectable.

X-3001 Process Building North Purge Vacuum~vacuation Vacuum Vent for HALEU Demonstration Cascade Total Stack Flow (m3) 8.28 E +05 Estimated,

,,concentr~tion Err9r MD.A\

    • Re.ease Percent Radionuclid~;;*

, µCi/ml

µCi/ml'*

µCi/ml.*

.. mCi MPC 234U (vent) 1.08 E -11 8.83E-13 3.47 E-12 8.94 E -03 234U (boundary) 1.04 E ~18 8.53 E,.20 3.61 E -19 0.000035%

235v (vent) 1.33 E -12 1.46 E -13 7.19 E -13 1.10 E-03 235U (boundary) 1.29 E-19 1.41 E -20 6.94 E-20 0.000004%

238U (vent) 1.06 E-11 1.llE-12 1.25 E -12 8.75 E -03 238U (boundary) 1.02 E-18 1.08 E -19 1.20 E -19 0.000034%

99Tc (vent) 0.00 E +00 0.00 E+00 0.00 E +00 0.00 E +00 99Tc (boundary) o.oo E +oo o.oo E +oo.

0.00 E+00 0.00 E+00 99Tc lab results were undetectable.