Text

-

b

\\

l I

NATHAN M.

NEWMARK j

caesutrwa sp.omtrmwo samvicas sss4 cnnt specmcramo suuma unnANA, su.moes eisoi 7 Septeniber 1971

)

.I

~~~0 s,

i e@tp" 1

i SEPg1971s9 an Mr. Edson G. Case, 0! rector Civtsfon of' Reactor Standards U.S. Atomic Energy Connission i

Washington, D.C.

20545 Re: Contract No. AT(49 5)-2667 i

William H. Zinner Nuclear Power Station Cincinnatl Gas and Electric Company, et al.

AEC Docket No. 50-358 Deer Mr. Case:

We are tr.nnaltting herewith 8 copies of our final report (? Septder 1971) c >ncerning 'Edequacy cf Structural Criterla for william H. Zinner Nuclear Power station" prepared by N. M. Newnerk, W. J. Hall, and A. J. Hendron, Jr.

l Respectfully suba.itted, t

I Sh % % wt.

N. M. Newma rk P9 Enclosure cc:

W. J. Hall A. J. Hendron, Jr.

l l

1709250109 870921?

C j,q Q j C/