Text

-

MSMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT C P. O. Box 15830, Sacramento CA 95852-1830,(916) 452 3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA GCA 87-908 DEC 2 71987 U. S. Nuclear Regulatory Commission Attn:

Frank J. Miraglia. Jr.

Associate Director for Projects Phillips Building 7920 Norfolk Avenue Bethesda, MD 20014 DOCKET NO. 50-312 RANCHO SECO NUCLEAR GENERATING STATION LICENSE NO. DPR-54 0FFSITE DOSE CALCULATION MANUAL (00CM)

Dear Mr. Miraglia:

The District hereby submits the approved Rancho Seco Offsite Dose Calculation Manual (0DCM), AP.310 Revision 5 for your review to support the evaluation of Proposed Amendment No. 155, Revision 2.

The attached ODCM represents a significant rewrite of the previous ODCM submitted to you via letter GCA 87-737, dated 10/30/87.

The revised ODCM incorporates the results of verification and validation (V&V) as well as NRC and internal reviews.

In preparing the ODCM an independent third-party V&V was conducted to provide assurance that the ODCM is ready to support plant operations.

The District is compiling an ODCM V&V report and will maintain the report in Rancho Seco files for future reference.

Please contact me if you have any questions. Members of your staff with questions requiring additional information or clarification may contact Mr. Richard Mannheimer at (209) 333-2935, extension 4919.

Sincerely,

/dfAhn G(Carl Andogfiini Chief Executive Officer, 1

Nuclear 8801110474 871227 PDR ADOCK 05000312 Attachment P

PDR

/

7 0$

0 i

l,(g){

cc:

G. Kalman, NRC, Bethesda (w/atch)

A. D'Angelo, NRC, Rancho Seco (

)

C. Willis, NRC, Bethesda

(

)

J.B. Martin, NRC, Region V

(

)

RANCHO SECO NUCLEAR GENERATING STATION O 1444o Twin Cities Road. Herald, CA 95638 9799;(209) 333 2935