MONTHYEARML23229A5262023-08-17017 August 2023 Inservice Inspection Summary Report - 1 RE24, ML23221A3002023-08-0909 August 2023 RE22 Inspection Summary Report for Steam Generator Tubinq, Rev. 1 (Epld L-2023-LRO-0029) ML23044A6192023-02-13013 February 2023 Summary Report for Inservice Inspection (2RE22) Completed in November 2022 ML22033A5442022-02-0202 February 2022 Inservice Inspection Summary Report -1RE23 NOC-AE-21003819, Inservice Inspection Summary Report - 2RE212021-07-15015 July 2021 Inservice Inspection Summary Report - 2RE21 ML21196A4922021-07-15015 July 2021 Inservice Inspection Summary Report - 2RE21 NOC-AE-21003806, Inservice Inspection Program Plan and Inservice Testing Program Snubber Inservice Test Plan for the Fourth Ten-Year Interval2021-05-20020 May 2021 Inservice Inspection Program Plan and Inservice Testing Program Snubber Inservice Test Plan for the Fourth Ten-Year Interval ML21144A1092021-05-20020 May 2021 Inservice Inspection Program Plan and Inservice Testing Program Snubber Inservice Test Plan for the Fourth Ten-Year Interval NOC-AE-20003765, Inservice Testing Program Description for the Fourth Ten-Year Interval2020-10-28028 October 2020 Inservice Testing Program Description for the Fourth Ten-Year Interval ML20303A2602020-10-28028 October 2020 Inservice Testing Program Description for the Fourth Ten-Year Interval NOC-AE-20003764, 1 RE22 Inspection Summary Report for Steam Generator Tubing2020-10-0707 October 2020 1 RE22 Inspection Summary Report for Steam Generator Tubing ML20281A8542020-10-0707 October 2020 1 RE22 Inspection Summary Report for Steam Generator Tubing ML20191A2702020-07-0909 July 2020 Inservice Inspection Summary Report -1RE22 NOC-AE-20003700, Proposed Alternatives to ASME OM Code 2012 Edition for the Fourth Inservice Test Interval (Relief Request PRR-01)2020-01-22022 January 2020 Proposed Alternatives to ASME OM Code 2012 Edition for the Fourth Inservice Test Interval (Relief Request PRR-01) NOC-AE-20003703, Proposed Alternatives to ASME OM Code 2012 Edition for the Fourth Inservice Test Interval (Relief Request PRR-04)2020-01-22022 January 2020 Proposed Alternatives to ASME OM Code 2012 Edition for the Fourth Inservice Test Interval (Relief Request PRR-04) NOC-AE-19003696, Supplemental Information for Proposed Alternative to ASME Code Requirements for the Repair/Replacement of Essential Cooling Water System Class 3 Buried Piping (Relief Request RR-ENG-3-24) EPID: L 2019-LLR-0096)2019-11-26026 November 2019 Supplemental Information for Proposed Alternative to ASME Code Requirements for the Repair/Replacement of Essential Cooling Water System Class 3 Buried Piping (Relief Request RR-ENG-3-24) EPID: L 2019-LLR-0096) NOC-AE-19003620, Proposed Alternative for Extension of Volumetric Examination Interval for Reactor Vessel Closure Head with Alloy 690 Nozzles in Accordance with 10 CFR 50.55a(z)(1) (Relief Request RR-ENG-3-23)2019-02-28028 February 2019 Proposed Alternative for Extension of Volumetric Examination Interval for Reactor Vessel Closure Head with Alloy 690 Nozzles in Accordance with 10 CFR 50.55a(z)(1) (Relief Request RR-ENG-3-23) NOC-AE-19003624, Inservice Inspection Summary Report- 1RE212019-02-0707 February 2019 Inservice Inspection Summary Report- 1RE21 NOC-AE-18003603, Transmittal of 2RE19 Inspection Summary Report for Steam Generator Tubing2018-10-18018 October 2018 Transmittal of 2RE19 Inspection Summary Report for Steam Generator Tubing NOC-AE-18003587, Inservice Inspection Summary Report -2RE192018-07-25025 July 2018 Inservice Inspection Summary Report -2RE19 NOC-AE-17003503, Inservice Inspection Summary Report - 1 RE202017-07-20020 July 2017 Inservice Inspection Summary Report - 1 RE20 NOC-AE-17003440, Inservice Inspection Summary Report -2RE18 Completed in November 20162017-02-0808 February 2017 Inservice Inspection Summary Report -2RE18 Completed in November 2016 NOC-AE-16003364, 1RE19 Inspection Summary Report for Steam Generator Tubing2016-04-25025 April 2016 1RE19 Inspection Summary Report for Steam Generator Tubing NOC-AE-16003355, Inservice Inspection Summary Report, 1RE192016-03-24024 March 2016 Inservice Inspection Summary Report, 1RE19 NOC-AE-15003282, Inservice Inspection Summary Report -2E172015-08-0606 August 2015 Inservice Inspection Summary Report -2E17 NOC-AE-14003170, Inservice Inspection Summary Report - 1 RE182014-08-26026 August 2014 Inservice Inspection Summary Report - 1 RE18 NOC-AE-14003139, RE16 Inspection Summary Report for Steam Generator Tubing2014-05-22022 May 2014 RE16 Inspection Summary Report for Steam Generator Tubing NOC-AE-14003112, Inservice Inspection Summary Report - 2RE162014-03-24024 March 2014 Inservice Inspection Summary Report - 2RE16 NOC-AE-13002968, Inservice Inspection Summary Report - 1RE172013-02-21021 February 2013 Inservice Inspection Summary Report - 1RE17 NOC-AE-12002803, Inservice Inspection Summary Report - 2RE152012-02-20020 February 2012 Inservice Inspection Summary Report - 2RE15 NOC-AE-11002722, RE16 Inspection Summary Report for Steam Generator Tubing2011-09-21021 September 2011 RE16 Inspection Summary Report for Steam Generator Tubing NOC-AE-11002706, Inservice Inspection Summary Report - 1RE162011-07-28028 July 2011 Inservice Inspection Summary Report - 1RE16 NOC-AE-11002651, Inservice Testing Program Description: Safety-Related Seismic Restraints (Snubbers) for the Third 10-Year Interval2011-03-14014 March 2011 Inservice Testing Program Description: Safety-Related Seismic Restraints (Snubbers) for the Third 10-Year Interval NOC-AE-10002585, Inservice Inspection Summary Report - 2RE142010-08-0202 August 2010 Inservice Inspection Summary Report - 2RE14 NOC-AE-10002577, Notification of Upgrading of the Inservice Inspection Program for the Third Inspection Interval2010-07-29029 July 2010 Notification of Upgrading of the Inservice Inspection Program for the Third Inspection Interval NOC-AE-10002565, Inservice Testing Program Description: Safety-Related Seismic Restraints (Snubbers) for the Third 10-Year Interval2010-07-13013 July 2010 Inservice Testing Program Description: Safety-Related Seismic Restraints (Snubbers) for the Third 10-Year Interval NOC-AE-11002684, Categorization of Risk-Informed Piping2010-06-20020 June 2010 Categorization of Risk-Informed Piping ML1006401202010-02-22022 February 2010 Inservice Testing Program Description for the Third 10-Year Interval NOC-AE-10002522, Inservice Inspection Summary Report - 1RE152010-02-16016 February 2010 Inservice Inspection Summary Report - 1RE15 NOC-AE-09002408, Transmittal of 2RE13 Inspection Summary Report for Steam Generator Tubing2009-03-24024 March 2009 Transmittal of 2RE13 Inspection Summary Report for Steam Generator Tubing NOC-AE-09002381, Inservice Inspection Summary Report - 2RE132009-01-20020 January 2009 Inservice Inspection Summary Report - 2RE13 NOC-AE-08002318, Inservice Inspection Summary Report - 1RE142008-06-23023 June 2008 Inservice Inspection Summary Report - 1RE14 NOC-AE-07002195, Inservice Inspection Summary Report - 2RE122007-07-25025 July 2007 Inservice Inspection Summary Report - 2RE12 NOC-AE-07002143, 1RE13 Inservice Inspection Summary Report for Steam Generator Tubing2007-04-16016 April 2007 1RE13 Inservice Inspection Summary Report for Steam Generator Tubing ML0701602012007-01-0808 January 2007 Inservice Inspection Summary Report - IRE13 NOC-AE-06001960, Inservice Inspection Summary Report2006-01-19019 January 2006 Inservice Inspection Summary Report NOC-AE-05001938, Refueling Outage Inservice Inspection Results for Steam Generator Tubing2005-10-12012 October 2005 Refueling Outage Inservice Inspection Results for Steam Generator Tubing NOC-AE-05001910, Inservice Inspection Summary Report - 1RE122005-07-15015 July 2005 Inservice Inspection Summary Report - 1RE12 NOC-AE-05001853, Revised Steam Generator Tube Inservice Inspection Plan for the Second Inspection Interval at Plant2005-03-0303 March 2005 Revised Steam Generator Tube Inservice Inspection Plan for the Second Inspection Interval at Plant NOC-AE-04001763, Inservice Inspection Summary Report for Welds and Component Supports - 2RE102004-07-22022 July 2004 Inservice Inspection Summary Report for Welds and Component Supports - 2RE10 2023-08-09
[Table view] Category:Letter
MONTHYEARML24029A2752024-01-29029 January 2024 Request to Reschedule Evaluated Force-on-Force Drill IR 05000498/20230042024-01-29029 January 2024 Integrated Inspection Report 05000498/2023004 and 05000499/2023004 ML24024A1162024-01-24024 January 2024 STP Unit 2 Request for Information IR 05000498/20244042024-01-18018 January 2024 Information Request for the Cyber-Security Baseline Inspection, Notification to Perform Inspection 05000498/2024404; 05000499/2024404 IR 05000498/20230032023-12-28028 December 2023 Acknowledgment of Reply to a Notice of Violation (NRC Inspection Report 05000498/2023003 and 05000499/2023003) ML23360A1692023-12-26026 December 2023 FEMA, Submittal of Radiological Emergency Preparedness Final Report for the South Texas Project Medical Services Drill Evaluated on August 31, 2023 NOC-AE-230040, Supplement to Proposed Alternate Frequency to Containment Unbonded Post-Tensioning System Inservice Inspection (Relief Request RR-ENG-4-06)2023-12-14014 December 2023 Supplement to Proposed Alternate Frequency to Containment Unbonded Post-Tensioning System Inservice Inspection (Relief Request RR-ENG-4-06) NOC-AE-230039, Docket Nos. Stn 50-498, Stn 50-499 - Reply to a Notice of Violation, NRC Inspection Report 05000498/2023003 and 05000499/20230032023-12-12012 December 2023 Docket Nos. Stn 50-498, Stn 50-499 - Reply to a Notice of Violation, NRC Inspection Report 05000498/2023003 and 05000499/2023003 ML23326A2592023-12-0505 December 2023 Review of the Fall 2022 Steam Generator Tube Inspection Report ML23339A1902023-12-0505 December 2023 Update Foreign Ownership, Control, or Influence (FOCI) IR 05000498/20234012023-12-0404 December 2023 Security Baseline Inspection Report 05000498/2023401 and 05000499/2023401 ML23324A0102023-11-16016 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23310A2282023-11-13013 November 2023 Integrated Inspection Report 05000498/2023003 and 05000499/2023003, and Notice of Violation ML23311A2082023-11-0909 November 2023 Reassignment of U.S. Nuclear Regulatory Commission Branch Chief in the Division of Operating Reactor Licensing for Plant Licensing Branch IV ML23298A0002023-11-0101 November 2023 the Associated Independent Spent Fuel Storage Installation - Issuance of Amendment Nos. 226 and 211 Related to Order Approving Indirect Transfer of Licenses and Conforming License Amendments ML23303A0782023-10-30030 October 2023 Submittal of Supplemental Information in Response to Order Consenting to License Transfers and Approval of Draft Conforming License Amendments ML23279A0342023-10-30030 October 2023 Associated Independent Spent Fuel Storage Installation - Order Approving Indirect Transfer of Licenses and Draft Conforming License Amendments (EPID L-2023-LLM-0004) (Letter) IR 05000498/20234032023-10-26026 October 2023 Material Control and Accounting Program Inspection Report 05000498/2023403 and 05000499/2023403 (Cover Letter) ML23317A1262023-10-12012 October 2023 South. Texas Project Physical Security Plan, Training and Qualification Plan, Safeguards Contingency Plan, and Independent Spent Fuel Storage Installation Security Program Revision 26 ML23279A1382023-10-0505 October 2023 Responses to Requests for Additional Information Related to Application for Order Approving Indirect Transfer of Control of Licenses ML23271A1942023-10-0303 October 2023 Notification of Commercial Grade Dedication Inspection (05000498/2024013 and 05000499/2024013) and Request for Information ML23270B2592023-09-27027 September 2023 Update Foreign Ownership, Control, or Influence ML23263B1132023-09-20020 September 2023 Operator Licensing Examination Schedule Revision 1 IR 05000498/20243012023-09-0707 September 2023 Notification of NRC Initial Operator Licensing Examination 05000498/2024301; 05000499/2024301 IR 05000498/20233012023-09-0101 September 2023 NRC Examination Report 05000498/2023301 and 05000499/2023301 ML23243B0562023-08-31031 August 2023 Supplemental Information to Application for Order Approving Indirect Transfer of Control of Licenses ML23236A6042023-08-24024 August 2023 Annual Dose Report for 2022 IR 05000498/20230052023-08-22022 August 2023 Updated Inspection Plan for South Texas Project Electric Generating Station, Units 1 and 2 (Report 05000498/2023005 and 05000499/2023005) - Mid Cycle Letter ML23229A5262023-08-17017 August 2023 Inservice Inspection Summary Report - 1 RE24, ML23229A5892023-08-17017 August 2023 Voluntary Response to Regulatory Issue Summary (RIS) 2023-02, Scheduling Information for the Licensing of Accident Tolerant, Increased Enrichment, and Higher Burnup Fuels ML23229A4992023-08-17017 August 2023 Supplement to Proposed Alternate Frequency to Containment Unbonded Post-Tensioning System Inservice Inspection (Relief Request RR-ENG-4-06) ML23228A2102023-08-15015 August 2023 Closure of Investigation (OI 4-22-19) ML23222A0322023-08-10010 August 2023 Report of Changes Made to Quality Assurance Program for Radioactive Material Packages ML23221A3002023-08-0909 August 2023 RE22 Inspection Summary Report for Steam Generator Tubinq, Rev. 1 (Epld L-2023-LRO-0029) ML23222A2792023-08-0909 August 2023 Submittal of Update Foreign Ownership, Control, or Influence (FOCI) IR 05000498/20230022023-07-28028 July 2023 Integrated Inspection Report 05000498/2023002 and 05000499/2023002 ML23198A0532023-07-24024 July 2023 Request for Withholding Information from Public Disclosure ML23188A1612023-07-14014 July 2023 the Associated ISFSI - Notice of Consideration of Approval of Indirect Transfer of Licenses and Conforming Amendments and Opportunity to Request a Hearing (EPID L-2023-LLM-0004) - Letter ML23193A9932023-07-11011 July 2023 Submittal of Update Foreign Ownership, Control or Influence (FOCI) ML23192A0482023-07-11011 July 2023 NRC Initial Operator Licensing Examination Approval 05000498/2023301; 05000499/2023301 NOC-AE-230039, Submittal of Update Foreign Ownership, Control or Influence (FOCI)2023-07-11011 July 2023 Submittal of Update Foreign Ownership, Control or Influence (FOCI) ML23180A2822023-06-29029 June 2023 Operator Licensing Examination Schedule ML23177A2522023-06-26026 June 2023 Units 1, 2 & Independent Spent Fuel Storage Installation - Biennial Submittal of Technical Specification Bases Changes, Commitment Changes, 10 CFR 50.59 Evaluation Summary, and 10 CFR 72.48 Evaluation Summary ML23166B0802023-06-14014 June 2023 Update Foreign Ownership, Control, or Influence (FOCI) ML23163A1762023-06-12012 June 2023 Application for Order Approving Indirect Transfer of Control of Licenses 2024-01-29
[Table view] |
Text
South Texas Pro/eel Electric Genemling Station P.O. Bo.r 289 W.,dswort/1, Texas 77481 July 9, 2020 NOC-AE-20003746 10 CFR 50.55a STI: 35034026 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 South Texas Project Unit 1 Docket No. STN 50-498 lnservice Inspection Summary Report - 1 RE22 Attached is the South Texas Project Electric Generating Station Unit 1 summary report for inservice inspections performed prior to and during scheduled refueling outage 1 RE22 completed in April 2020. This summary report satisfies the reporting requirements of American Society of Mechanical Engineers ASME Code Section XI, Article IWA-6230.
There are no commitments in this letter.
If there are any questions regarding this report, please contact Ali Albaaj at (361) 972-8949 or me at (361) 972-7806.
a JI ,-'1 Chris Georgeso General Manager, Engineering aa
Enclosure:
Summary Report for the 1 RE22 lnservice Inspection of Unit 1 South Texas Project Electric Generating Station cc:
Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Chief Inspector Texas Department of Licensing and Regulation Boiler Program P.O. Box 12157 Austin, TX 78711
SUMMARY
REPORT for the 1RE22 INSERVICE INSPECTION of UNIT 1 SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION STP NUCLEAR OPERATING COMPANY Spring 2020
COVERSHEET 1RE22 INSERVICE INSPECTION
SUMMARY
REPORT SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION, UNIT 1 P.O. BOX289 WADSWORTH, TEXAS 77483 USNRC DOCKET NO: 50-498 OPERATING LICENSE NO: NPF-78 COMMERCIAL OPERATION DATE: AUGUST 25, 1988 Prepared by:_ .;_;:;_. ___,,
=-
Eric LaOw e( /
Reviewed by: --r:............,..:....------- Date /C:, 3JA.{.
C*,.,,*"'...
SCOPE COMPONENT SUPPORTS, STEAM GENERATOR TUBING, WELDS, THERMAL FATIGUE, REPAIR/REPLACEMENT, AND SYSTEM PRESSSURE TESTING INSPECTION PROGRAMS (IWB, IWC, IWD, IWE, IWF)
The examinations summarized in this report were performed in accordance with the 2004 Edition of the ASME Code,Section XI that is applicable to the South Texas Project, Unit 1, third ten-year interval (09/25/2010-09/24/2020), third period (12/20/2017-09/24/2020). This report covers selected ASME Code Class 1, 2, and 3 Systems/Components. This report is documented in accordance with the requirements of ASME Section XI Code Case N-532-4.
Examinations and tests required by the Code are scheduled in accordance with "Inspection Program B" as defined in IWB-2412 for ASME Code Class 1 Systems/Components, IWC-2412 for ASME Code Class 2 Systems/Components, IWD-2412 for ASME Code Class 3 Systems/Components, and IWF-241 0 component supports.
ASME Code Class 1 components were examined as prescribed by Table IWB-2500-1 and the applicable Examination Categories, which established the examination frequency at each refueling outage. The ASME Code Class 2 Systems/Components were examined in accordance with Table IWC-2500-1, Examination Categories. The ASME Code Class 3 Systems/Components were examined in accordance with Table IWD-2500-1, Examination Categories. Component Supports were examined in accordance with IWF- Table 2500-1, Examination Categories.
FORM OAR"! OWNERS ACTIVITY REPORT (Code Case N-532-4)
Report Nunmber OAR-1RE22 Plant_South Texas Project Electric Generating Station Unit No.., I_Commercial service date_ August 25,1988 _Refueling outage no. IRE22 (If applicable)
Current inspection interval IWB, IWO IWD, IWF - 3rd : [WE -3rd (l$l,21ld,3Id,41h other)
Current inspection period IWB. IWC, IWD. IWF " 3rd_;_
(1st, 2"d, 3rd)
Edition and Addenda of Section XI applicable to the inspection plan _2004 Edition Date and revisioft of inspection p}anj3ctober 15, 2019 / Revision 9 Edition and Addenda of Section XI applicable to repajrs/replacement aGtlvlties, if different than the inspection plan N/A Code Cases used: N-532-4. N".578-1, N-729-4. N"770-2, N-722<
CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct: (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repalr/replacement activities and evaluations supporting the completion of 1RE22 conform to the requirements of Section XI <
(Refueling outage number)
Signed EEX/C / ^<^C^^^'N'^ _IS1 Program En sineer Date: June 16, 2.020 (Owner or Owner's Designee, Title)
CERTIFICATE OF INSERYICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and pressure Vessel Inspectors and the State or Province of JHonda__^_ and employed by_ One CIS Insurance Co._ of_Lvnn, MassaclHisetts have inspected the items described m this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by tills report in accordance with the requirem^ts of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repairs/
replacements activities and evaluation described this report. Furthermore, neither the inspector nor his employer shall be Bable in any manner for any personal injury or property damage or a loss of any kind arising from the connected wth this inspectioa Commissions ^ ^ ^ ^ ^ FL ' 1& ~ 00 ^^~
lnspe^g0s Signature National Board, State, Province, and Endorsements Date £>^/^/^>^
TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITiONS THAT REQUIRE EVALUATION FOR CONTINUED SERVICE 1RE22 SPRING 2020 ASME Item Item Evaluation Description Category Number Description F-A F1.43 LHX1A: Diesel Lube Oil 3 Inservice Inspection identified a loose bolt on LU Heat Exchanger Support Skid Heat Exohanger Support SkicL
[Summary 423700] [VTC-2020-051]
Corrective Action to tighten bolt.
[CR 20-3928]
Inspection afterCorrective Action.
[VTC-2020-075]
Additional Exams performed in 1 RE22 in accordance with IFW-2220.
Re-examination scheduled for 1 RE23
^'
a^
TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE CORRECTIVE DATE CLASS ITEM DESCRIPTION SYSTEM DESCRIPTION OF WORK REPAIR / REPLACMENT PLAN MEASURE COMPLETED ESSENTIAL 3 REPLACEMENT PIPE COOLING Replaced piping. Welding. 3/7/2019 1-17-030 WATER ESSENTIAL 3 REPLACEMENT PIPE COOLING Replaced piping. Welding, 1/17/2019 1-17-031 WATER MECHANICAL AUXiLJARY 3 REPLACEMENT PIPE Replaced Piping. Welding. 3/7/2019 1-17-036 BUILDING HVAC MECHANICAL AUXILIARY 3 REPLACEMENT PIPE Replaced Piping. Welding. 1/17/2019 1-18-002 BUILDING HVAC SAFETY Replaced valve and piping.
2 REPLACEMENT PIPE & VALVE 7/16/2019 1-18-029 INJECTION Welding, ESSENTIAL Replaced piping and fittJngs.
3 REPLACEMENT PIPE COOLING 3/7/2019 1-19-003 Welding.
WATER ESSENTIAL Removed/! nstaHed pipe support.
3 REPLACEMENT SUPPORT COOLING 3/7/2019 1-19-004 Welding.
WATER ESSENTIAL Replaced piping and fitting.
3 REPLACEMENT PIPE COOLING 3/7/2019 1-19-005 Welding.
WATER ESSENTIAL Removed/! nstaHed support.
3 REPLACEMENT SUPPORT COOLING 3/7/2019 1-19-006 Welding.
WATER ESSENTIAL 3 REPLACEMENT PUMP COOLING Replaced Pump. 2/18/2019 1-19-007 WATER
^
^i
^il obl^ ^\^D
TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITtES REQUIRED FOR CONTINUED SERVICE CORRECTIVE DATE CLASS ITEM DESCRIPTION SYSTEM DESCRIPTION OF WORK REPAIR / REPLACMENT PiAH MEASURE COtWPLETED ESSENTIAL Replaced NF seismic 3 REPLACEMENT SUPPORT 2/18/2019 1-19-008 COOLING WATER support.
Replaced fiange and ESSENTIAL 3 REPLACEMENT FLANGE returned to WHSE. Weld 2/25/2019 1-19-009 COOLING WATER Cut.
Replaced flange and ESSENTIAL 3 REPLACEMENT FLANGE returned to WHSE. Weld 2/25/2019 1<<19-010 COOLING WATER Cut.
ESSENTIAL 3 REPLACEMENT FASTENER Replaced fasteners. 2/19/2019 1-19-012 COOLING WATER ESSENTIAL 3 REPLACEMENT FASTENER Replaced fasteners. 3/7/2019 1-19-013 COOLING WATER ESSENTIAL Replaced Thermowell and 3 REPLACEMENT THERMOWELL 2/6/2019 1-19-014 COOLING WATER SOL Welding.
REACTOR 1 REPLACEMENT VALVE Removal of valve. 3/29/2020 1-19-017 COOLANT REACTOR 1 REPLACEMENT VALVE Removal of valve. 3/29/2020 1-19-018 CQOLANT REACTOR 1 REPLACEMENT VALVE Removal of valve. 3/29/2020 1-19-019 COOLANT 1 REPLACEMENT VALVE REACTOR Installed rebuilt valve. 4/6/2020 1-19-020 COOLANT REACTOR 1 REPLACEMENT VALVE installed rebuilt valve. 4/6/2020 1-19-021 COOLANT REACTOR 1 REPLACEMENT VALVE installed rebuilt valve. 4/6/2020 1-19-022 COOLANT INCORE Replaced fitting at Thimble 1 REPLACEMENT FITTING 4/5/2020 1-19-023 iNSTRUMENTATION D-12 and C-8.
INCORE Replaced fitting and adapter 1 REPLACEMENT FITTING 4/5/2020 1-19-024 INSTRUMENTATION atThimbleP-4.
^
^
o^/-^0'20
TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTiNUED SERVICE CORRECTIVE DATE CLASS ITEM DESCRIPTION SYSTEM DESCRIPTION OF WORK REPAIR / REPLACMENT PLAN MEASURE CONPUETED iNCORE Replaced fitting and 1 REPLACEMENT FITTING 4/5/2020 1-19-025 INSTRUIVIENTATION adapter at Thlmbie B-3.
SAFETY INJECTION REPLACED DISC, 1 REPLACEMENT VALVE 3/28/2020 1-19-033 SI0010B.
REPLACED DISC.
1 REPLACEMENT VALVE SAFETY INJECTION 3/29/2020 1-19-034 SI0010A.
Removed/lnstalied STEAM 1 REPLACEMENT DIAPHRAGM diaphragm on inspection 4/1/2020 1-19-044 GENERATOR ports SG-1 A. Welding.
STEAM Removed/jnstaHed Hatch to 1 REPLACEMENT HATCH GENERATOR MSA.SG-1B.
4/1/2020 1-19-045 COMPONENT 3 REPLACEMENT VALVE Replaced PSV. 9/25/2019 1-19-046 COOUNG DEESEL Replaced DG Intercooter 3 REPLACEMENT PIPE 2/7/2020 1-19-049 GENERATOR Piping.
ESSENTIAL Replaced downstream EW 3 REPLACEMENT FLANGE 11/21/2019 1-19-051 COOLING WATER Range. Welding.
ESSENTIAL 3 REPLACEMENT VALVE Replaced valve. 2/6/2020 1-20-003 COOLING WATER DIESEL 2 REPLACEMENT FASTENER Replaced fasteners. 2/10/2020 1-20-004 GENERATOR 2 REPLACEMENT SNUBBER FEEDWATER Replaced snubber 3/27/2020 1-20-010
^
^'
^1^}^