ML20154H344

From kanterella
Jump to navigation Jump to search
Exam Rept 50-313/OL-88-01 of Exam Administered During Wk of 880418.Exam results:11 of 12 Candidates Passed All Portions of Exam
ML20154H344
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 05/13/1988
From: Pellet J, Whittemore J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20154H333 List:
References
50-313-OL-88-01, 50-313-OL-88-1, NUDOCS 8805250306
Download: ML20154H344 (48)


Text

. . _ .

v D A

APPENDIX U.S. NUCLEAR REGULATORY COMMISSION REGION IV Operator Licensing Exam Report: 50-313/0L88-01 Operating License: DPR-51 Docket No: 50-313 Licensee: Arkansas Power & Light Company P.O. Box 551 Little Rock, Arkansas 72203 Facility Name: -Arkansas Nuclear One, Unit 1 (AN01)

Examination at: AN01 Chief Examiner: -

1) 3 iP

}. E. Whitt'emore, Examiner, Date Operator Licensing Section, Division of Reactor Safety Approved by bbY J. L. Pellet Chief T 13 Date Operator Licensing Section, .

Division of Reactor Safety '

Summary NRC Administered Examinations Conducted During the Week of April 18, 1988 Report 50-313/0L88-01 NRC administered examinations to 12 candidates. Eleven candidates passed all portions of the examination and will be issued the appropriate license, l l

1 l

I 8805250306 DR 880517 ADOCK 05000313 DCD

- - . ~ . . - . __. _. - .

I- 1 a

2 DETAILS

1. Persons Examined SR0 License Examinations: Pass - 11 Fail - 1
2. Examineri J. Whittemore, Chief Examiner S. McCrory B. Picker M. Spencer
3. Examination Report Perfonnance results for individual examinees are not included in this report as it will be placed in the NRC Public Document Room and these results are not subject to public disclosure,
a. Examination Review Comment /Reson. tion In general, editorial coments or changes made during the examination, or subsequent grading reviews are not addressed by this resolution section. This section reflects resolution of substantive coments made by AN01. Further, this section will address only those coments that were not fully incorporated into the master examination key which is included in this report. The full text of the coments is attached.

6.06.a The question states, ". . . loss of instrument air to the component," and then lists the ADV. An answer that assumes the ADV actually lost air should be accepted if answered and explained that way.

ADV control will go shut, RCS temperature and pressure will increase.

Resp: Not accepted. The question is designed to solicit i knowledge of backup capabilities and specifically states l instrument air and not backup air. l 6.13.b Credit should be given for a "No" response if answer indicates that reactor will not remain at power (Rx. Trip) if two channels are placed in S/D Bypass. l Resp. Not accepted. Question merely asks if the action is possible.

1 I

i

l

, 4  :

3 l

8.08.b Memorizing the order in which a list of personnel ap) ears in an administrative procedure is beyond the reasonaale i scope of required SR0 knowledge. The procedure is used during the process doing temporary modifications therefore memorization of the preferred order is not required. We request Part b be deleted from the test.

Resp. Not accepted. Question solicits. inherent knowledge about the procedure, mainly how specific personnel interface with the procedure under normal conditions. The SR0 should be aw're of desired personnel to perform verification duties. Successful candidates demonstrated greater than 80 percent performance on this question.

b. Site Visit Summary-(1) At the end of the written examination administration, the facility licensee was provided a copy of the examination and answer key for the purpose of commenting on the examination content validity. It was explained to the facility licensee that regional policy was to have examinations finalized within 30 days. Thus, a timely response was desired to attain this goal.

(2) At the conclusion of the site visit, the Chief Examiner met with facility representatives to discuss the visit. The following personnel were present:

NRC FACILITY J. E. Whittemore K. W. Canitz A. Cox E. Force W. E. Perks J. D. Vandergrif t Mr. Whittemore opened the meeting by thanking those present for the cooperation received during the site visit. Those present were also informed that current guidelines do not allow disclosure of preliminary operating examination results. Other items discussed were as follows:

1. Mr. Whittemore stated that several problems had been noted informally to the simulator instructors concerning simulator performance, and these problems would be stated formally in the Simulation Facility Fidelity Report (included in this report).

J l

l

.i .

'4

2. Mr. Vandergrift inquire _d about the conduct and cooperativeness of the onshift control room staff during walkthrough examinations. Mr. Whittemore stated that the control room staff had been most cooperative while the examinations were ongoing, and that-proper conduct had been~ observed at all times.

+

3. Mr. Force inquired if examiners would consent to use facility generated scenarios during the simulator portion of future examinations. Mr. Whittemore responded that this would be possible provided that the requirements of NUREG 1021 were met and that the scenario bank was large enoughtoprovideanadequatenumberofscenarios(through sampling) to preclude compromise. Mr. Whittemore noted that he had used some of the one event scenarios submitted by AN01 in the preparation of NUREG-1021. ES-302, Att. 4 ,

forms for the current examination.

4. Mr. Canitz expressed appreciation of the attitude exhibited by the NRC examiners to overcome problems that arose during the simulator examinations due to either simulator discrepancies or instructor inexperience in the administration of initial examinations,
c. Generic Comnents One area of generic weakness was noted. Generally, SR0 candidates were not sure how to ascertain that all requirements had been met to exit refueling shutdown conditions and enter cold shutdown or heatup conditions,
d. Master Examination and Answer Key A copy of the final AN01 written examination and answer key is l attached. The valid facility licensee comments have been '

incorporated into the answer key.

e. Facility Examination Review Comments The facility licensee comments regarding the AN01 written examination are attached. l
f. Simulation Facility Fidelity Report All items on the attached Fidelity Report have been discussed with the facility simulator instructor personnel.

+

l

i i U. S. NUCLEAR REGULATORY COMMISSION SENIOR REACTOR OPERATOR LICENSE EXAMINATION FACILITY: _68EeU565 UMCLEe8 QUE-1__ ,

REACTOR TYPE: _EWB-Q&W1ZZ______________

DATE ADMINISTERED:_gg4Qd/16._______________ i EXAMINER: l

. _WBIIIEdQBEt_Jt._________

CANDIDATE: _________________________ i INSIBUQIIQU5_IQ_QoNQIQeIEi l

Use separate paper for the answors.

Staple question sheet on top of the answer Write answers on.one side only.

sheets. Points for each question are indicated in parentheses after the question. The passing grade requires at least 70% in each category and a final grade of at least 80%. Examination papers will be picked up six (6) hours after the examination starts.

% OF CATEGORY  % OF CANDIDATE'S CATEGORY

__VeLUE_ _IDIeL ___SQQBE___ _V6LUE__ ______________QeIEQQBI_____________

_25tQQ__ _25tQQ ___________ ________ 5. THEORY OF NUCLEAR POWER PLANT OPERATION, FLUIDS, AND THERMODYNAMICS

_25t0Q _ _lizQQ ___________ ________ 6. PLANT SYSTEMS DESIGN, CONTROL, AND INSTRUMENTATION

_25tQQ__ _25tQQ ___________ ________ 7. PROCEDURES - NORMAL, ABNORMAL, EMERGENCY AND RADIOLOGICAL CONTROL

.25tQQ__ _251Q0 __________. ________ 8. ADMINISTRATIVE PROCEDURES, CONDITIONS, AND LIMITATIONS 1QQtQQ__ ___________ ________% Totals Final Grade All work done on this examination is my own. I have neither given nor received aid.

Candidate's Signature

r- l 1 .

St__IBEQBl_QE_UURLEeB_EQWEB_ELeUI_QEEBoIl00t_ELUIQ1t_6NQ PAGE 2 IBEBdQQ188dIQ1

_ QUESTION 5.01 (1.00)

Calculate the stable count rate for a reactor that has a source strength of 5 CPS and Keff is 0.95. (1,0)

ANSWER 5.01 (1.00)

SCR = S/(1 - Keff) [0.5)

= 5/ 1- 0.95 = 100 CPS (0.5] (1.0)

REFERENCE Unit 1 PSRT, P. 144 192003K102 ...(KA'S)

QUESTION 5.02 (1.50)

Reactor power doubles in 1 min. 20 sec's. What was the reactor period for this power gain. Show all work. (1.5)

ANSWER S.02 (1.50)

P= Poe(t/T) (0.5) 2= In e(80/T) (0.25]

0.693 = 80/T [0.25 T= 115.4 seconds (accept 110 -120 seconds) [0.5] (1.5)

REFERENCE Unit 1 PSRT, P. 129 192003K109 ...(KA'S)

(***** CATEGORY 05 CONTINUED ON NEXT PAGE *****)

5t__IBEQBl_QE_NUCLEeB_EQWEB_ELeNI_QEEBoIl0Nt_ELylR$t_eNQ PAGE 3 IBEBdQQ1NedICS QUESTION 5.03 (2.50)

  • True or False:
a. It will take less time for the reactor to go from 2% to 4% power than from 25% to 50% power if the period is constant.
b. Halving the period will double the Start Up Rate.
c. If reactor power is increased from 1% at a stable SUR of 0.5 DPM, power will be 5%. in one minute,
d. If a positive reactivity addition to a just critical reactor results in a 100 sec, period, the same amount of negative reactivity addition will result in a 100 second negative period.
e. If a shutdown reactor is started up from a 10 CPS count rate, criticality should be expected at a count rate between 2000 and 2500 CPS. (2.5)

ANSWER 5.03 (2.50)

a. False
b. True
c. False
d. False
e. False (0.5 ea.) (2.5) 4 REFERENCE Unit 1 PSRT, Pp. 129 - 148 192003K110 ...(KA'S)

QUESTION 5.04 (1.50)

a. Explain the mechanisms which could cause Shutdown Margin (SDM) to increase or decrease as a result of plant heatup. (1.0)
b. Explain which control room instrument (s) would be used to ditect a changing SDM and why the indication responds as it does. (1.0)

I

u i

j Sz__IBEQBl_QE_UUCLE68_EQWE8_ELeUI_QEE86Il0Ni_ELVIQ1t_86Q PAGE 4 IBEBdQQ1Eed101 ANSWER 5.04 (1.50)  ;

a. 1. Boron expanding out of the core adds positive reactivity, causing SDM to decrease.
2. Decreasing density results in loss of neutron moderation adding negative reactivity, causing SDM to increase.
3. Increasing fuel temperature provides negative doppler which will increase SOM. (Any 2, 0.5 es.) (1.0)
b. As SDM changes, Keff changes and therefore subcritical multiplication will change. (0.25) CONCEPT This leads to a change in neutron population which is detectable on the source range. (0.25) (0.5)

REFERENCE Facility Exam Question Bank 192002K114 ...(KA'S)

QUESTION 5.05 (1.00)

Choose the correct answer.

For a reactor restart after shutdown with equilibrium Xenon, the. decreased Xenon concentration reached due to burnout. (Assume constant power ramp rate.) ,

a. Would be lower for a startup commenced 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> after shutdown.
b. Would be lower for a st artup commenced 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> after shutdown.
c. Would be lower for a startup commenced 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> after shutdown.
d. Would be approximately equal for any startup between 5 and 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> after shutdown.

(1.0)

ANSWER 5.05 (1.00)

"C."

REFERENCE Unit 1 PSRT, P. 203 192006K107 192006K114 ...(KA'S)

(***** CATEGORY 05 CONTINUED ON NEXT PAGE *****)  !

s 5t__IBEQBY_QE_UUCLE8B PoVEB_ELeUI_QEEBoIl00t_ELVIRSt_eUD PAGE 5 IBEBdQQ16ed1GS QUESTION 5.06 (1.00)

Choose the correct response.

The preferred method for dampening a Xenon oscillation is to initially:

a. Insert control rods into a low flux area,
b. Withdraw control rods from a low flux area.
c. Insert control rods into a high flux area.
d. Withdraw control rods from a high flux area. (1.0)

ANSWER 5.06 (1.00)

"c."

REFERENCE Unit 1 PSRT, P. 205 192006K114 ...(KA'S) i QUESTION 5.07 (1.00)

Concerning equilibrium Samarium-149 (Sm) reactivity, which of the following statements is correct? 50% equilibrium Sm reactivity is:

a. one-quarter of 100% equilibrium Sm reactivity.

3

b. one-half of 100% equilibrium Sm reactivity.
c. three-quarters of 100% equilibrium Sm reactivity.
d. equal to 100% equilibrium Sm reactivity.  ;

ANSWER 5.07 (1.00) 1 "d"

REFERENCE Unit i PSRT, P. 207 j 192006K115 ...(KA'S)  ;

I

(***** CATEGORY 05 CONTINUED ON NEXT PAGE *****)

Et__IBEQBl_QE_UUQLEeB_EQWEB_ELeUI_QEEB81100t_ELulR$t_6HR PAGE 6 IBEBdQQ166dIQS QUESTION 5.08 (1.00)

Which one of the following statements most correctly describes the change in the Doppler and Moderator Temperature Coefficients (FTC and MTC) as a function of core life (80L to EOL)?

0. FTC becomes more negative and MTC becomes more riegative.
b. FTC becomes more negative and HTC becomes more positive.
c. FTC becomes more positive and MTC becomes more negative,
d. FTC becomes more positive and MTC becomes more pooitive.

ANSWER 5.08 (1.00)

"a" (1.0)

REFERENCE

, UNIT 1 PSRT, Pp. 175, 180 192004K107 ...(KA'S)

QUESTION 5.09 (2.00)

a. How will the reactor response differ to equal positive react vity insertions as the reactor approaches criticality? (1.0)
b. How much reactivity must be added to a critical reactor for $t to be considered prompt critical? (Actual value is NOT required.) (0,5)
c. Why are extrinsic neutron sources installed in the reactor dere?(0.5)  !

l i

, - . . -. -... ,,..- _ _ , , . , _ .n......-., ,

St__IBEQBr_QE_UVQLEeB_EQWEB_EL6UI_QEEBoIl0Ut_ELU1QSt_6UQ PAGE 7 IBEBdQQ1Ued1CS

/

ANSWER 5.09 (2.00)

a. The neutron population increase is greater (0.25) and the time to stabilize is longer (0.75] as Keff approaches 1. (1.0)  !
b. Beta effective (or beta) (accept numbers). (0,5)
c. Neutron sources are required to assure sufficient indication to control the startup. CONCEPT (0.5)

REFERENCE AN01 PSRT,Pp. 140-145 192003K101 192003K108 192003K111 ...(KA'S) l QUESTION 5.10 (2.00)

a. Explain why the effect of the core delayed neutron fraction is numerically larger than the fraction itself. (1,0) i
b. Explain HOW the effect of the delayed neutron fraction is numerically  ;

different at the end of cycle compared to the beginning of cycle.

WHY? (1.0) i i

ANSWER 5.10 (2.00)  ;

a. Delayed neutrons are created at a lower energy and therefore more '

likely to thermalize and cause fission. Also accept an explanation i of how importance factors may actually decrease value of effective i fraction. CONCEPT. (1.0)

b. Numerically smaller. (0.5) (Accept explanation of quicker response.)

Due to the buildup of fissionable isotopes (Pu-239 and Pu-241) which have smaller individual fractions compared to U-235. (0.5] (1.0) a REFERENCE j

AN01 PSRT, Pp. 124-126 1 192003K107 ...(KA'S) 4 I l i

1

(***** CATEGORY 05 CONTINUED ON NEXT PAGE *****)

1 1

I

,r _ _ . - - - ,. - , _ , . - - _ _ _ _ _ - - _ _ _ _ . . . _ _ - , - - _ _ _ . . _ , - . _ - . _ '

4 5___IBEQBl_QE_UVQLE68_EQWEB_ELeUI_QEEBoIl0Ut_ELUlQSt_68Q PAGE 8 IBEBdQQ166dICS 4

i QUESTION- 5.11 (1.50)

For a centrifugal pump operating in a closed loop system, how will the available AND minimum Net Positive Suction Head vary as the pump speed is changed with other parameters constant. Explain your answer. (1.5)

ANSWER 5.11 (1.50)

As pump speed increases the potential for cavitation is greater so the minimum NPSH required increases. [0.5) With increasing flow, there are increasing head losses at the pump suction, [0.5) so the available NPSH decreases. [0.53 (1.5)

REFERENCE ANO HTT&F HOBK. P.83 191004K113 ...(KA'S)

QUESTION 5.12 (1.50)

What steam generator pressure is required to maintain 200 deg's F subcool-4 ing margin in the RCS when RCS pressure is 595 psig. Show all work. (1.5)

ANSWER 5.12 (1.50)

1. Add 15 psi to 595 psig = 610 psia (0.25)
2. Using steam tables, G 610 psia, Tsat = 488 +/- 2 deg's F (0.5)

I i 3. Tsat in S/G = Trcs - Tsubcooling = 488 - 200 = 288 +/- 2 deg's F(0.25) {

4. Using steam tables, Psat e Tsat = 288 deg's F = 56 +/- 4 psia or 5

41 +/- 4 psig. (0.5)

REFERENCE Steam Tables

. 002000K515 ...(KA'S) i

(***** CATEGORY 05 CONTINUED ON NEXT PAGE *****)

0 4

_ ,_ - . - , - - . . - _ .. . - - . . . - . . - . . - - - . .-- - - J

Et__IBEQBl_QE_ NUCLE 68_EQWEB_ELeBI_QEEB6IIQNt_ELU105t_eNQ PAGE 9 IBEBdQQ1NedICS QUESTION 5.13 (2.50)

Concerning the Once-Through Steam Generators:

a. In what heat transfer region (s) does the secondary side temperature change the least? Why? (1.0)
b. In what region (s) does the primary side temperature change the least?

Why? (1.0)

c. If full power RCS core delta T is 48 deg's F., what is delta T at 40%

with 1 RCP stopped? (0.5)

ANSWER 5.13 (2.50)

a. In the nucleate (and film) boiling regions, (0.5) because all thermal energy is being used to cause the phase change. (0.5] (1.0)
b. In the superheet region, (0.5) due to poor heat transfer characteristics of dry steam. (0.5] (1.0)

I

c. 25.6 oF. (Accept 25 -26 oF.) (0.5)

REFERENCE ANO HTT&F HDBK. Pp. 140, 141 193008K126 ...(KA*S) j l

QUESTION 5.14 (1.00)

Which one of the following actions, carried to extreme, should not hinder, natural circulation and subsequent core cooling?

a. Lowering S/G 1evel
b. Lowering RCS pressure
c. Increasing RCS temperature l l
d. Increasing PZR level 4

,. , - _. _ - -, -,- -, - . , - - - . , , - - ~ ~ .

HA__IBEQBl_QE_UUCLE88 EQWE6. h. P AfE h_ELulQSt_88Q PAGE 10 IBEBdQQ186dICS ANSWER 5.14 (1.00)

"d."

REFERENCE ANO HTT&F HDBK. Pp. 144 - 146 193008123 ...(KA'S)

QUESTION 5.15 (1.50)

What are the three limits (or concerns)of flux peaking for the Unit 1 Reactor Core? (1.5)

ANSWER 5.15 (1.50)

Power imbalance, Quadrant power tilt, and Linear heat rate.(0.5 ea) (1.5)

REFERENCE AN01 PSRT, P.114 193009K107 ...(KA'S)

QUESTION 5.16 (1.50) )

l State the axial core locations (mid-plane, upper half, or lower half) where j you would expect to see maximum clad temperature and maximum heat flux et i full power for beginning of life conuitions. Explain your reasoning.(1.5) i ANSWER 5.16 (1.50)  ;

l Max. clad temp. would occur in the upper half of the core. [0.5) Max. heat I i flux occurs about core mid-plane. (0.5). Max heat flux is where max power j in produced, and temperature is dependent upon heat flux and coolant '

temperature. (0.53 (1.5)

! REFERENCE ANO HTT&F HOBK. Pp. 124, 125 i

193008K129 ...(KA'S) i

(***** CATEGORY 05 CONTINUED ON NEXT PAGE *****)

St__IBEQBl_QE_ NUCLE 68_EQWEB_ELeNI_QEE86IIQNt_ELU105t_eUQ- PAGE 11 ,

IBEBdQQ1NedICS QUESTION 5.17 (1.00)

'TRUE OR FALSE

a. The thermal conductivity within a fuel pellet tends to decrease over core life. ,
b. Initial fuel to clad gap thermal conductivity decreases during initial power operation. (1,0)

I ANSWER 5.17 (1.00)

a. TRUE j b. TRUE (0.5 ea.) (1.0)

REFERENCE ,

, ANO HTT&F HDBK., Pp. 118,119  ;

193008K116 ...(KA'S) i 1

l

. r s

l l

t j (***** END OF CATEGORY 05 *****)

i I

i

, - - _ - - . _ , . . _ _ . - - . _ . . . - .-,,,,-.--..-m..-,--,_l

6t__EleUI_111IEdi_QE1100t_GQUIBQLt_eUQ_INSIBudEUISIIQU PAGE 12 QUESTION 6.01 (2.00)

a. How does 103 prevent OTSG water inventory from dropping below that corresponding to 15% load during low power operations? -(1.0)
b. How does the ICS act to prevent flooding of the aspirating ports in the OTSG? (1.0)

ANSWER 6.01 (2.00)

a. When level drops, control of feedwater switches to low level limits to maintain the minimum dp. (CONCEPT) (1.0)
b. When level increases above maximum permitted value, control of feedwater switches to the high level limit control circuit, which limits OTSG level. (CONCEPT) (1.0)

REFERENCE AN01 STM 1-15, p. 4, 5

] 035010A301 ...(KA'S) i

, QUESTION 6.02 (2.00)

a. Explain the function of the CRA Torque Tube Assembly. (0.5)
b. What is the purpose of the synchronizing bearing in the control rod drive mechanism? (0.5) l l c. Explain in detail why an APSR, when de-energized, will not trip.(1.0) l.

ANSWER 6.02 (2.00)

a. Prevents rotation of the lead screw. OR, Transmits rotating motion I

of CRDM to vertical motion of lead screw. (0.5)

b. Ensures both segment arms move together. (0.5)
c. Located on the segment arms is a button (0,5) which will strike the motor tube to prevent the segment arm from moving outward.(0,5) (1.0)

I 1I

i Et__EL6NI.11SIEdi_QE110Nt-QQUIBQLt_6NQ_INSIBudENI6I1QN PAGE 13 ,

l REFERENCE

Facility Exam Bank 001000G007 001000K601 ...(KA'S)

QUESTION 6.03 (2.50) i Assume en ES signal has occurred due to low RCS pressure and answer the following TRUE or FALSE.

j a. Upon ES actuation, the MUT outlet valve shuts,

b. The 5 psig oil pressure interlock is bypassed for MU pump start due to l an ES signal.

1

, c. During high pressure injaction the make up pump recirc isolation valves remain open to precluoe pump damage.

d. The RCP seal return valves and the seal return isolation valve both i receive a close signal upon ES actuation.
e. All 3 HPI pumps receive an ES start signal from both ES channels 1 and
2. (2.5) 7 ANSWER 6.03 (2,50)

, e. False i

b. True
c. False
d. True
o. False REFERENCE
STM 1-4, Pp. 9, 11, 13, 27  !

j 006000A303 006000K406 006020K401 ...(KA'S) 1 l e

QUESTION 6.04 (2.00) l j e. What are 3 uses or purposes of the Reactor Coolant Quench Tank? (1.5) l 3

b. How is the Quench Tank cooled? (0.5)  !

f i

k I

4 m . _ _ . _ _ . - . ~ , , , , , . , - . , . _ , - . . - _ ,_ , . _ _ - . . . _ . _ . . . . _ . , . _ . _ _ , _

l

!; 14 Et__ ele 8I_11SIEbS_QE1100t_CQUIBQLt_eUQ_INSIBudENIeIlQU PAGE i

ANSWER 6.04 (2.00)

a. 1. Collect effluent from pzr. safeties und electric relief.  !

2 Alternate flow path for seal return. i

3. Act as a water trap for R8 vent hdr. l
4. Collects RCP seal leakage. (Any 3, 0.5 ea.) (1.5)
b. By dilution with condensate. (0.5)  !

, REFERENCE STM 1-3, P. 8 4 002000K104 ...(LA'S) ,

t QUESTION 6.05 (3.00)

For the components numbered 1 - 6 on the attached fig. 6-1, state their ,

position or condition (open, closed, running, stopped) for the control room ventilation system operating:

e. Normally. (0.6)
b. Due to initiation from area high radiation. (1.2)-
c. Due to initiation by smoke detector. (1.2)

'I J i i

ANSWER 6.05 (3.00)

Require column "c" if exhaust detector is assumed or "d" if supply smoke detector is assumed.

a. 1. Stopped b. 1. Running c. 1. Stopped d. 1. Stopped
2. Shut 2. Shut 2. Open 2. No Effect i
3. Open 3. Open 3. Shut 3. No Effect
4. Shut 4. Shut 4. Open 4. No Effect
5. Running E. Stopped 5. Running 5. Stopped l l 6. Open 6. Shut 6. Open 6. Shut 1

(0.1 ea. for a, 0.2 ea. for b, c, or d) (3.0)

! I 4

I 5

j 7

0

~

9 7

N V A C F

' a f U

A H

X E

=

5 4

8 y (% 7 V

  1. ,3 C s'

b/ _

R S AI E

DI S

T U

O =

L O

f$a R Tm N

_ Om C

9) 33 _

A 8 _

8 8 _

F S

V QS i

F V lI

= _

b _

I ll I

/C IH/ 'O'C 1

b

~ _

8 =

0 R f 9 E _

7 TM _

- UO V PO 5 C MR 0 O 9 C 7 V _

C _

g 9

0 9

'a 7 V

C

~ 3 a C k e. L.

ht__EL6UI_111IEd1_QESIQut_CQUIBQLt_eUD_IUSIBudEUI6IIQU PAGE 15 REFERENCE STM 1-47, Pp. 14, 15, 24, 25, 26 000060A102 ...(KA'S)

QUESTION 6.06 (2.00)

For the following components, explain how RCS temperature and pressurizer level may be IMMEDIATELY affected by loss of instrument air to the components.

a. Main Steam Atmospheric Dump Valves, with the valve open.
b. Turbine Bypass Valves, that are open.
c. Letdown Orifice Isolation Valve, that is open.

ANSWER 6.06 (2.00)

a. No effect (0.25) as valves may operate from MSIV accumulator system.

[0.5) (0.75)

b. Temperature and level may increase (0.25) as emergency accumulators will act to close valves. [0.53 (0.75)
c. Pzr level will increase due to valve closure. (0.5)

REFERENCE STM 1-15, Pp. 12, 15 STM 1-4, P.

078000K302 ...(KA'S)

QUESTION 6.07 (2.00)

a. If both start up transformers are available, what determines which will be utilized if a fast transfer of 6.9 KV power to backup source becomes necessary due to loss of unit auxiliary transformer? (0,5)
b. What will happen if the fast transfer ao predicted in "a" above does not occur? (0.5)
c. If both 6.9 KV buses are auto transferred to Startup Transformer #2, l what additional automatic action will occur? Why? Consider only the electrical distribution system and assume full power conditions.(1.0)  ;

l

, w

1 6t__ELeUI_11SIEUS_QESIQUt_QQUIBQLt_eUQ_IUSIBudENIeIIQU PAGE 16 ANSWER 6.07 (2.00)

a. Whichever has been selected by the operator on the preferred standby switch in the control room. (0,5)
b. Automatically transfer to the other standby transformer. (0.5)
c. Auto load shedding will occur (0.5) to shed 1 Reactor Coolant Pump from each bus, (0.25] to prevent XFMR overload. [0.25] (1.0)  !

I REFERENCE j STM 1-32, Pp.lg, 20 062000K403 ...(KA'S)

QUESTION 6.08 (1.00) l Choose the correct statement below:

1 a.

l The emergency diesel generators can be started by signals from 480V and 4160V undervoltage relays.  !

1

b. It is not possible to feed buses A3 and A4 from one emergency diesel generator, j
c. The undervoltage relay on a vital 4160V bus has no effect on the  ;

individual component feeder breakers on that bus. '

l

d. Interlocks to prevent paralleling buses A3 and A4 are strictly mechanical. (1,0)

ANSWER 6.08 (1.00)

REFERENCE STM l-32, Pp.25, 26 1 064000A301 ...(KA'S) )

(***** CATEGORY 06 CONTINUED ON NEXT.PAGE *****)

ht__ELeUI_SYSIEdS_DESIQut_CQUIBQLt_6NQ_luSIBubENIollQU PAGE 17 QUESTION 6.09 (1.00)

Which of the following conditions would act to increase the calculated loop BTU limit?

a. Feedwater Temperature decreasing
b. OTSG pressure decreasing,
c. Loop RCS flow decreasing,
d. Selected Th decreasing. (1.0)

ANSWER 6.00 (1.00)

"b."

REFERENCE STM 1-64, P.9 059000A410 ...(KA'S)

QUESTION 6.10 (1.00)

Choose the correct statement:

a. The power to the CRDM windings is AC.
b. If one set of programmer lamps is de-energized, the rods for that group will not drop,
c. If a programmer stops with 3 phases to it's CRDM's energized, it will automatically continue to move in the same direction until only 2 phases are energized.
d. The "Asymetric Rod" alarm Camber light) on the diamond panel receives  !

it's inputs from relative position indicators and the absolute average  ;

position indicator. (1.0) I ANSWER 6.10 (1.00)

"b."

ht__EL6BI_11SIEdS_QES106t_QQUIBQLt_ouR_IUSIBudEUIeIIQU PAGE 18 REFERENCE Facility Exam Bank & STM 1-02, P. 12 001000G004 ...(KA'S)

QUESTION 6.11 (2.00)

a. How does an ESAS analog channel INHIBIT BISTABLE function to allow plant cooldown/depressurization? (1.0)
b. What is the purpose of the Removal / Test Relays within the Logic Buffer modules of the ESAS Analog system? (1.0)

ANSWER 6.11 (2.00)

a. Blocks HP and LP inj ect ion (0.5) by inserting a false RCS pressure signal to prevent actuation. (0,5) (1.0)
b. To provide protection for removal of a module (0,5) by passing a trip signal to the digital system. [0.5) (1,0)

REFERENCE STM 1-65, Pp. 3, 4 013000K101 013000K412 ...(KA'S)

QUESTION 6.12 (2.50) i i

Indicate on which panel (s) (C116, R33, or R08) the following Remote i Shutdown Indication may be found' '

l

a. S/G "B" Start Up Range Level l
b. DELETED
c. Compensated Pressurizer Level i
d. Make Up Tank Level
e. Source Range Power l
f. Reactor Coolant Loop "A" inlet temperature I
g. RCS Loop "B" Th (2.5)

s ht__EL6NI_SYSIEdS_QES10Nt_CQUIBQL&_6NQ_INSIBudENIol10N PAGE 19 ANSWER 6.12 (2.50)

a. C116, R33 NOTE. Accept the following descriptions
b. DELETED or locations of the panels:
c. C116, R 0 8, R33 R08 - Outside MUT Room
d. 0116, R08 R33 - Orange door / El Heater deck
o. C116 C116- Desey Panel or Unit 1 computer room
t. C116
g. R33 (0.25 for ea. location) (2.5)

REFERENCE STM 1-70, Pp. 1-3 000068K201 ...(KA'S)

QUESTION 6.13 (2.00)

a. What occurs within a Reactor Protection System (RPS) Channel when the following are placed in bypass: Ignore setpoints.

l

1. Channel By-Pass Keyswitch
2. Shutdown By-pass Keyswitch (1.5)
b. Is it possible to place 2 channels in bypass simultaneously for each of the system features above, with the plant at full power? (0.5) l

l 8

~

6___EL6UI_11SIEdS_QESlQUt_QQUIBQLt_6UQ_INSIBudENI8IIQU PAGE 20 ANSWER 6.13 (2.00)

9. 1. By-passes all channel trips. [0.3)
2. Bypasses Low press. trip, Var. press. trip, Power / Pump trip, and Power / Flow / Imbalance trip. (0.2 for es. trip) .

Imposes Shutdown High Flux Trip, and Shutdown High Pressure trip. (0.2 for es. trip) (1.5)

b. Channel By-pass. ----------------NO Shutdown By-Pass. ---------------YES [0.25 ea.) (0.5)

REFERENCE STM 1-63, P. 25 012000K406 012000K604 ...(KA'S) 1 i

l l

l I

l

(***** END OF CATEGORY 06 *****)

\

. - _ . - . - , . . . - . - . ~ , . . - . . , = - . . , ,

l Zt__EBQQEQUBE1_:_UQBdokt_oBUQBdekt_EdEBGEUQ1_6UQ PAGE 21 BeQ10LQQIQaL_QQUIBQL l l

QUESTION 7.01 (2.50)

a. According to the radiation protection manual, what are the. weekly exposure limits for an escorted visitor? State the conditions associated with each of the two limits. (1.0)
b. For ANO personnel, what is the MAXIMUM weekly limit if there is a demonstrated need and all necessary approvals are obtained? (0.5)
c. Who is authorized to approve emergency exposure that is likely to be greater than 5 rem? (0.5)
d. Why does ANO have external radiation exposure limits and guidelines that appear to be more restrictive than the federal limits already in place. (0.5)

ANSWER 7.01 (2.50)

a. 1. 100 mrem / week (0.25) without completed exposure history (NRC Form
4) (0.25)
2. 300 mrem / week (0.25) with completed history. (0./25]
b. The quarterly limit. (Accept 1.25, 2.5, or, 3.0 Rem with explanation of limit.) (0.5)
c. Any one of the following: Emergency Coordinator, Emergency Ops Facility Director, Shift Supervisor, or, VP Nuc. Ops. [0.5)
d. ALARA, or prevent or minimize unwarranted exposure. OR, Prevent violating federal rules / regulations. (0,5)

REFERENCE ANO 1000.31, Pp. 30, 37, 38, 39 j 194001K103 ...(KA'S)  !

l l

l l

(***** CATEGORY 07 CONTINUED ON NEXT PAGE *****)

l 1

I

. _- - . . . .. -- - - . . -- l

Zt__EBQQEQUBES_:_UQBdekt_eBUQBdokt_EdEBGEUQY_eUR PAGE 22 86010LQQ196L_QQUIBQL QUESTION 7.02 (2.50)

a. During refueling operations, a boron sample reveals that Loron concentration in the canal and Spent Fuel Pool has unexpectedly dropped to 1865 PPM. Describe the boration flow path that should be used to restore concentration. (0.75)
b. What are the conditions and restrictions for non-licensed operators to operate fuel handling bridges? (0.75)
c. If a fuel handling accident occurs in the Reactor Building (RB), what two additional actions should be immediately ordered in conj unction with or after plant notification and RB evacuation? (1.0)

ANSWER 7.02 (2,50)

a. (BAA Tk. or BA Pump.) (0.25] > (SFP Cooling or Recirc System) (0.25)

> Suct. of DHR Pump. (0.25]

b. May not handle nuclear fuel (0,5) unless directly supervised by a licensed operator. [0.25)
c. 1. Shutdown RB purge system.
2. Isolate th RB.
3. Place plant in safe condition /teke action to mitigate problem.
4. Order ops personnel to control room.

(Any 2, 0.5 ea.]

REFERENCE ANO 1502.04 Pp. 4, 5, 83 ,

033000K405 034000A201 034000G006 ...(KA'S) I l

QUESTION 7.03 (2.50)

c. When performing Category "E" valve position verification for "Plant Preheatup and Precritical checklist, what does the asterisk (*) in the POSITION column denote to the verifier? (0.75)
b. What does an asterisk adj acent to a step in the plant startup procedure denote to the operator? (0.5)
c. What is required to be plotted during RCS heatup? (0.75)
d. Why should RCP operation below 400 psig be minimized? (0,5)

~ . - . - . .

l O

Zz__EBQQEQUBES_:_UQBdokt_oBUQBdokt_EUEBQEUQY_6UQ PAGE 23 BoR19LQQ1 col _QQUIBQL ANSWER 7.03' -(2,50)

a. The specified valve position may be reversed to facilitate component operation from a redundant loop. CONCEPT
b. The step must be performed in the listed sequence. (0.5)
c. 1. RCS pressure vs. temperature
2. RCS temperature (vs. time)
3. Pzr. temperature (vs. time) (0.25 es.]
d. To prevent excessive seal wear. [0.5)

REFERENCE ANO 1102.01 P. 27 ANO 1102.02, Pp. 3, 9, 10 002000G013 003000G001 194001K101 ...(KA'S)

QUESTION 7.04 (3.00)

e. What is the primary, backup, and third or alternate backup means of communications within the plant during the performance of Alternate Shutdown? (0.75)
b. ANO 1203.02 (Alternate Shutdown) states that the Service Water System is a maj or safe shutdown system utilized by the procedure. . State why this system is important to safe shutdown. (0.75)
c. Choose the correct answer.

If Alternate shutdown of unit 2 must be performed due to a fire in the unit 2 control room, then unit 2 . ;ct :

1. Commence shutdown at normal rate.
2. Trip and go to hot shutdown.
3. Commence shutdown at maximum safe rate.
4. Maintain stable plant conditions. (1.0)
d. True or False. l l

If the unit 1 control must be evacuated due to toxic fumes from a fire j in the unit 2 control room, then unit 1 must also perform Alternate Shutdown in accordance with ANO 1203.02. (Alternate Shutdown) (0.5) i y ,

Z___EBQQEQVBE1_:_UQBdelt_oBUQBdokt_EdEBGEURY_6NQ PAGE 24 86Q10LQQ10eL_CQUIBQL ANSWER 7.04 (3.00)

a. Portable radios and alternate SD radio cabinet, Dial telephone (PAX),

and Gaitronics. [0.25 ea.]

b. Service water is required to sustain EDG, makeup pump, and possibly EFW systems operation. Accept required to support other safe shutdown systems. [0.75)
c. "3."
d. False REFERENCE ANO 1203.02 Pp. 1-4 000068G010 ...(KA'S)

QUESTION 7.05 (2.00)

a. For en indicated Asymetric Rod condition, what are 2 methods of determining if the problem is due to faulty instrumentstion? (1.0)
b. If a group of rods are moving due to a programmer 1smp fault, how can the rod motion be stopped? (0.5)
c. If rods cannot be driven after verifying that Reactor Demand and I Diamond Stations are in manual, what should be done next? (0.5) i ANSWER 7.05 (2.00)
a. 1. Utilize PI channel Bypasses to find and isolate a faulty string.
2. Compare with a zone indicating switch.
3. Use computer trending capabilities to determine rod behavior.
4. Determine tilt or imbalance. (Any 2, 0.5 ea.)
b. Remove the fuses in the (left) cabinet of the affected CRD power supply. (0.5)
c. Transfer the affected group to the auxiliary power supply. (0.5]

Zi__EBQREQUBE1_:_UQBdelt_6BUQBd6Lt_EdEBQEUQ1_60Q PAGE 25 8601QLQQ1G6L_CQUIBQL REFERENCE ANO 1203.03, Pp. 2, 4, 6 001000A203 001000A407 ...(KA'S)

QUESTION 7.06 (1.50)

c. What are 2 abnormal indications or conditions that may arise if the unit is operated continually at full power without pressurizer bypass spray flow? (1.0)
b. What mitigating action action should the operator take? (0.5)

ANSWER 7.06 (1.50)

a. 1. Low spray line temperature (alarm at 520 oF.) (0,5)
2. Abnormal difference between Pzr. and RCS boron conc. (0.5)
b. Operate spray and heaters as necessary to maintain spray line temperature and equalize boron concentration. (0.5)

REFERENCE ANO 1203.15, P. 5 010000A202 ...(KA'S)

QUESTION 7.07 (1.50)

a. After a dilution problem has been found and corrected with the reactor critical, which method below should NOT be used to restore boron concentration?
1. Utilize batch controller.
2. Direct feed from boric acid addition tank to letdown line.
3. Direct from BWST.
4. Utilize boron feed line bypassing batch controller.- (1.0)
b. If a dilution is detected while the reactor is shutdown on DHR system, and the vessel head in place, what additional source of possible dilution beside normal makeup, should be secured? (0.5)

Zt__EBQQEQUBES_ _UQBdeL&_6080Bdekt_EdEBGEUQ1_eUD PAGE 26 BeQ10LQQ1CeL_CQNIBQL ANSWER 7.07 (1.50)

a. "2." [1.0)
6. RCP seal supply (0.5)

RF.FERENCE ANO 1103.04 Pp. 5.6 & ANO 1207.17, P.4 004000A206 ...(KA'S)

QUESTION 7.08 (2.50)

a. For a simultaneous loss of RCP seal injection and seal cooling resulting in Reactor trip and stopping of all pumps, which should you attempt to restore first f. cooling or inj ect ion) ? (0.5)
b. What special precaution (s) should the operator observe in the restoration of seal injection flow? Why? (0.75)
c. The procedure for a sheared RCP shaft tells the operator to immediately trip the effected pump. What are 3 parameters or indications that may be used to determine the affected pump? (0.75)
d. After stopping a RC Pump at power due to abnormal vibration, indication of reverse rotation is noted. What action should be taken immediately? (0.5)

ANSWER 7.08 (2.50)

a. Inj ect ion (0.5]
b. Restore slowly (0.5) to avoid thermal shock and the subsequent damage I of seal parts. [0.26) CONCEPT
c. Vibration monitor, Pump motor current, or SPDS. [0.25 ea.]
d. Manually trip the reactor, [0.25] and stop all pumps. [0.25]

REFERENCE ANO 1203.31, Pp. 3,4,9 003000A101 003000A202 003000G001 ...(KA'S) j l

(***** CATEGORY 07 CONTINUED ON NEXT PAGE *****)

. .=. . _ _ . .__

Zt__BBQQEQUBES_:_UQBdeL&_eBUQBdekt_EdEBGEUGX_600 PAGE 27 BeQIQLQQ1 gel _GQUIBQL QUESTION 7.09 (2.50)

When subcooling margin has been lost, the operator is allowed to bump an RC Pump to regain natural circulation,

c. Why is the operator required to decrease steam generator pressure to a saturation temperature below CET average temperature? (0,5)
b. What is the criteria for selecting the pump to be bumped? (0,5)
c. How and where are the pump start interlocks bypassed for bumping the pump? (1.0)
d. If RC Pumps can not be bumped, what is the next manipulation the operator should perform to start natural circulation flow? (0.5)

ANSWER 7.09 (2.50)

a. To establish the steam generator as a heat sink. [0.5)
b. Select a pump in the loop with the smallect void. [0.5)
c. Manually close the RC Pump breaker (0.53 locally. (0.5)
d. Open Hot leg high point vents. [0.5)

REFERENCE ANO 1202.01, Pp. 49, 50 0030000001 003000K507 ...(KA's)

(***** CATEGORY 07 CONTINUED ON NEXT PAGE *****)

l Zt__EBQQEQUBE1_:_UQBdelt_oBUQBdeL&_EdEBGEUQ1_eUQ PAGE 28 BeQ10LQQ10eL_QQUIBQL

)

QUESTION 7.10 (2.50)

According to the Emergency Procedure for Steam Generator Tube Rupture (SGTR):

a. When can the emergency cooldown rate be used? (0.5)
b. What action may be required of the operator do to obtain EFW for RCS cooldown and why is this action necessary? (1.0)
c. Why is it preferred to reduce reactor power at 5%/ min. rather than trip during SGTR? (0.5)
d. What are 2 components or systems that should be isolated from the affected'S/G during initial power decrease to minimize secondary contamination? (0.5)

ANSWER 7.10 (2.50)

a. (Greater than 500 oF.) when leak rate is greater than HPI capacity.

(Also accept: non-isolable steem leak on effected S/G outside RB.[0.5)

b. Override the vector close signal. [0,5) The EFIC is designed to feed the steam generator with the highest pressure and may have locked out the unaffected steam generator. [0.5) CONCEPT
c. To prevent a release due to lifting of main steam safeties. (0.5)
d. EFW P-7 steam supply, Steam to MSR's, and Steam line drains. '

(Any 2, 0.25 ea.]

REFERENCE ANO 1202.01, Pp.84-100 000038A136 000038K306 ...(KA'S)

QUESTION 7.11 (2.00)

e. When recovering from degraded power conditions, which non-vital 4160 VAC bus would you recover first? Why? (1.0)
b. Why is loss of NNI "X" power considered more severe than loss of NNI "Y" power? (0.5)  ;
c. Why does the procedure for BLACKOUT require the operator to remain at Hot Shutdown instead performing a natural circulation cooldown? (0.5)

I

Zi__EBQQEQUBE1_:_UQBd6Lt_6BNQBd6Lt_EdEBQEUQY_68Q PAGE 29 B6010LQQ1Q6L_CQUIBQL ANSWER 7.11 (2.00)

a. Bus A-2. (0.5] To provide cooling water to instrument and breathing air compressors (0.25] and provide an additional bank of pressurizer heaters. [0.25]
b. "X" power supplies (buffer amplifiers which) drive indicators. (0.5]
c. No means to improve SDM [0.25] or make up for RCS leakage / shrinkage.

[0.25]

REFERENCE ANO 1202.01 Pp-119, 137, 147 000055E102 000055G003 000057K301 ...(KA'S)

(***** END OF CATEGORY 07 *****)

A at__oQd1BISIBoIIVE_EBQQEQUBESt_QQUQ1110NSt_6UQ_ Lid 1IoIl0NS PAGE 30 QUESTION 8.01 (3.00)

a. What action must be taken, and in what time frame, if the unit is operating with the minimum shift crew composition and one of the Reactor Operators becomes ill? (0.5)
b. How long may the shift crew remain below the minimum composition and what action must be taken if this time ir exceeded? (1.5)
c. Fifteen minutes before the scheduled areival of the on-coming shift, one of the three on-coming RO's calls in sick and says he will not be coming in. The Shift Supervisor decides to call in another operator due to the overtime status of his own shift. He also decides that since the relief operator should arrive shortly after shift change (approximately 30 minutes) that his shift can go home and let the on-coming shift start with two RO's. Were his decisione correct?

JUSTIFY your answer. Assume the plant is operating in Mode 1. (1.0)

ANSWER 8.01 (3.00)

a. Immediately (0.25) attempt to restore minimum crew composition (0.25]

such as call in replacement operators,

b. 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> (0.5). Place the plant in a mode where the minimum crew composition is met (1.0].
c. Decisions were correct (0.5). Minimum crew composition was met without calling in the additional operator (0.5).

REFERENCE AN01 Technical Specification, Table 6.2-1 194001A103 2.5/3.4 194001A103 ...(KA'S)

(***** CATEGORY 08 CONTINUED ON NEXT PAGE *****)

l Bz__eQU1U1118611YE_EBQQEQUBES&_CQUQ1110NSt_oNQ_L101IoI1QUS PAGE 31 I 1

l l

l QUESTION 8.02 (2.00)

The plant is in Hot Standby when the following information is turned over to the on-coming Shift Supervisor:

1.8 gpm - leakage past check valves from RCS to both Core Flood Tanks  ;

(0.9 GPM ea.)

1.2 gpm - Primary to secondary leakage (total) with RCS activity of  ;

0.2 uCi/gm of I-131.

4.8 gpm - Total RCS leakage Indicate whether any RCS leakage or other limits are exceeded, including the limit that was exceeded. (2.0)

ANSWER 8.02 (2.00)

The leakage limits for unidentified leakage (1.0) of greater than i GPM

[1.0) is being exceeded.

REFERENCE ANO2 Technical Specification 3.1.6 a 3.10 002020G011 3.3/4.0 002020G011 ...(KA'S)

QUESTION 8.03 (2.00)

The AN01 Technical Specifications require that the the Core Flood Tanks be operable when RCS pressure is above 800 psig. What are four (4) conditions required to be verified to satisfy this requirement? VALUES ARE NOT ,

REQUIRED, only the parameter need be listed. (2.0)

ANSWER 8.03 (2.00)

- Isolation valves open

- Water volume

- Boron concentration

- Cover pressure

- Pressure and level instrumentation operable (any 4, 0.5 each) l REFERENCE l AN01 Technical Specification 3.3.3 006020G005 3.5/4.2*

006020G005 ...(KA'S)

(***** CATEGORY 08 CONTINUED ON NEXT PAGE *****)

1 l

I l

Sz__60dINISIB811VE_EBQQEQUBESt_CQUQIIl06St_eUQ_LIdIIoIIQUE PAGE 32 l

QUESTION 8.04 (1.00)

Per 10 CFR 55, "Operators' Licenses", what must be done by a licensed ooerator to maintain his/her license in an "active" status?" (1.0)

ANSWER 8.04 (1.00)

The operator shall actively perform the functions.of the appropriately liccnsed operator (0.25) on a minimum of seven 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> shifts (0.25) or five 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> shifts (0.25) per calendar quarter (0.25).

REFERENCE 10 CFR 55.53(e) l 194001A103 2.5/3.4 194001A103 ...(KA'S)

QUESTION 8.05 (2.50)

TRUE or FALSE:

a. A 10 CFR 50.59, "Changes, Tests, and Experimento", review is required for changes to non-safety related procedures ac well as safety related procedures, j i
b. A Senior Reactor Operator is a "certified 10 CFR 50.59 reviewer" due l to having an active SRO license,
c. A procedure change that expands the acceptance criteria of a i surveillance does not constitute a change of intent of the procedure.
d. The Interim Procedure Approval Process may be used to implement a procedure change that changes the intent of a procedure as long as it does not involve en unresolved safety question.
e. Following interim approval of a procedure change applicable to BOTH  ;

units, the change form will be placed in the procedure change update l manual binder in the Unit 1 Control Room. (2.5) l I

r-.-- - - ,

at__6QUIGISIBoIIVE_EBQQEQUBEft_QQU0111082t_68Q_L1d116I1083 PAGE 33 ANSWER 8.05 (2.50)

s. true
b. false
c. false
d. false
e. true (0.5 each)

REFERENCE ANO 1000.06, Procedure Review, Approval, and Revision Control, Rev 27, pg 3, 9, 15 194001A101 3.3/3.4 194001A101 ...(KA'S)

QUESTION 8.06 (2.00)

a. List, in order of preference, the three (3) means of communication to be used for IMMEDIATE NOTIFICATIONS to the NRC. (1.5)
b. WHO, by title, is normally designated to make this notification?(0.5)

ANSWER 8.06 (2.00)

e. 1. ENS
2. Commercial
3. HPN (0.4 for each line, 0.1 for each preference) l
b. Shift Administrative Assistant (0.5)

REFERENCE ANO 1000.08, NRC Reporting and Communications, Rev 24, pg 10 - 12 194001A104 3.0/3.2 194001A104 ...(KA'S)

(***** CATEGORY 08 CONTINUE 0 ON NEXT PAGE *****)

s et__oQUINISIBoIIVE_EBQQEQUBESt_GQUQ1Il0Unt_oNQ_ lid 11aIIQU$ PAGE 34 QUESTION 8.07 (3.00)

a. What two (2) persons, by title, may sign for authorizing the placement of Hold Cards? (0.5)
b. What two persons, by title, are required to review the tagout for adequate boundary isolation? (0.5)
c. What two (2) persons, by title, may authorize intentionally entering an Action Statement of Tech Specs due to tagging? (1.0)
d. List the order of placing and removing contractor tags and ANO Hold Cards when being used on the same component (which tags should be hung first, removed first, etc.). (1.0)

ANSWER 8.07 (3.00)

a. SS or CRS [0.25 each) on the affected unit
b. Licensed Operator and Lead Craftsman (0.25 each)
c. Affected Unit's Operations Superintendent or Operations Manager (0.5 each)
d. Install ANO Hold Card, then contractor tag. Remove contractor tag, then ANO Hold Card (1.0).

REFERENCE ANO 1000.27, Hold and Caution Card Control, Rev 10, pg 12-14, 23 19400lK102 3.7/4.1 194001K102 ...(KA'S)

QUESTION 8.08 (3.00)

a. List five (5) examples of temporary modifications. (2.0)
b. Arrange the following list of personnel in order of preference for.

performing the independent verification of a temporary modification installation. STATE WHICH ORDER THE LIST IS IN, 1. e. most to least preferred. (1.0)

1. Cognizant engineer
2. Another lead craftsman of the same discipline
3. Responsible supervisor
4. Cognizant SRO on the affected unit

at__eQUINISIB611VE_EBQQEQUBEnt_CQUQ1110NSt_6NQ_ lid 11oI1QN1 PAGE 35 ANSWER 8.08 (3.00)

a. - Lifted leads for the purpose of altering a function

- Electrical j umpers

- Pulled circuit cards

- Intentionally disabled annunciatce alarms

- Mechanical j umpers

- Blank flanges

- Disabled relief or safety valves

- Temporary power supplies (5 required at 0.4 each)

- Blocked relays

b. 83, 2, 1, 4 (Subtract 0.33 for each manipulation to put in the correct order)
  • Most Preferred.

REFERENCE ANO 1000.28, Temporery Modification Control, Rev 8, pgs 4, 19 194001A103 2.5/3.4 194001A103 ...(KA'S)

QUESTION 8.09 (2.50)

, o. When an event occurs that is common to both units such as e security alert, fire in a common building, etc., which Shift Supervisor is responsible for responding to the event? (0.5)

b. Key shift personnel shall not enter areas from which they cannot respond to the control room within 10 minutes. Name TWO (2) positions which fall under "key shift personnel." (1.0)
c. List two (2) areas from whien returning to the control room may take more than 10 minutes. (1,0)

ANSWER 8.09 (2.50)

a. The SS receiving the notification (0.5) is responsible for incident response.
b. Shift Supervisor and STA (0.5 each) l 1
c. - cooling tower area containment

- emergency cooling pond area ( 2 at 0.5 each)

I 1

0 4 at__eQd1NISIBoIIVE_EBQQEQUBESt_CQUQ1110NSt_eUQ_L101IoI10US PAGE 36 REFERENCE ANO 1015.01, Conduct of Operation, Rev 32, pg 10, 25 194001A103 2.5/3.4 194001A103 ...(KA'S)

QUESTION 8.10 (1.00)

TRUE or FALSE:

a. Non-licensed operators may manipulate the reactor reactivity controls if directly supervised by a licensed operator and the trainee is enrolled in a license training program. (0.5)
b. Non-licensed operators may operate indirect controls of reactivity such as steam generator pressure or feed flow with the knowledge and consent of a licensed control room operator (direct supervision is not required). (0,5)

ANSWER 8.10 (1.00)

a. true (0.5)
b. true (0.5)

REFERENCE ANO 1015.01, Conduct of Operation, Rev 32, pg 17, 18 194001A111 2.8/4.1*

194001A111 ...(KA'S)

QUESTION 8.11 (3.00)

a. Define a Category "E" valve? (1.0)
b. What physically ensures that their position remains as intended?(0.5)
c. Who may waive the independent verification on Category "E" valve operations (non-emergency)? (0,5)
d. TRUE or FALSE. When an independent verification is performed on a Category "E" valve, it is not necessary to actually reposition the valve. (0.$)
e. TRUE or FALSE. Independent verification of throttle valve position may be accomplished by observing the first operator throttling the valve. (0.5)

'at__oQd1UISIBoIIVE_EBQQEQUBESt_QQURIIl0NSt_600_L151IeIl0US PAGE 37 ANSWER 8.11 (3.00)

a. Valves in the flow path of a safety related system (0.33] required'to be in a specified position for the system to perform its safety function (0.33] and whose mispositioning could go undetected from the control room (0.34].
b. All category "E" valves are locked (0.5].
c. Operations Superintendent (0.5]
d. True (0.5]
e. True (0.5]

REFERENCE ANO 1015.01, Conduct of Operation, Rev 32, pgs 40-41 194001K101 3.6/3.7 194001K101 ...(KA'S) i

)

- _ ._. .__ _ - . _ . _ _ . _ _ _ . . _ . _ _ . , _ _ . _ . . _ _ _ . . .~.. _ _ _ _

flRC LICEllSE EXN4It!ATIO1 IINID0tJT EQUATIO11S, C0:ISTNITS, NiD C0iiVERSI0liS 6 = rii*Cp *deltaT 6=U*A*deltaT P = Po*10 sur*(t) P = P *et /T SUR = 26/T T = 1*/p + (p-p)/X p T=1/(p-p) T = ($-p)/X p p = (Keff-1)/Keff = deltaKeff/Keff p = 1*/Eeff + jeff/(1+ X.T)

A = in2/tg = 0.693/tg X = 0.1 seconds-1

-ux I = Io*e CR = S/(1-Keff) 2 R/hr = 6*CE/d feet Water Parameters 1 gallon = 8.345 lbm = 3.87 liters 1 ft3 = 7.48 gallons Density 0 STP = 62.4 lbm/ft3 = 1 gm/cm3 Heat of vaporization = 970 Btu /lbm Heat of fusion = 144 Btu /1N 1 atmosphere = 14.7 psia = 29.9 inches Hg.

Miscellaneous Conversions 1 curie = 3.7 x 101U disintegrations per second 1 kilogram = 2.21 lbm i horsepower = 2.54 x 103 Btu /hr 1 mw = 3.41 x 106 Btu /hr 1 inch = 2.54 centimeters degrees F = 9/5 degrees C + 32 degrees C = 5/9 (degrees F - 32) 1 Btu = 778 ft-lbf  !

i 9