.c2 RATING DATA REPORT DOCKET NO.

50-259 DATE MARCH 87 PREPARED BY S.A.RATLIFF TELEPHONE 205-729-2937 OPERATING STATUS 1.

Unit Name: BROWNS FERRY UNIT ONE 2.

Reporting period: MARCH, 1987

3. Licensed Thermal Power (MWt): 3293 4.

Nameplate Rating (Gross MWe): 1152 5.

Design Electric Rating (Net MWe): 1065 6.

Maximum Dependable Capacity (Gross MWe): 1098.4 7.

Maximum Dependable Capacity (Net MWe): 1065 8.

If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reason: N/A 9.

Power Level To which Restricted, If Any (Net MWe)- N/A

10. Reason For Restrictions, If Any: N/A THIS YEAR-TO MONTH DATE CUMULATIVE
11. Hours In Reporting Period 744.0 2160 111080
12. F.'ours Reactor Was Critical 0.0 0

59521

13. Reactor Reserve Shutdown Hours 0.0 0

6997

14. Hours Generator On Line 0.0 0

58267

15. Unit Reserve Shutdown Hours 0.0 0

0

16. Gross Thermal Generation (MWh) 0.0 0

168066787

17. Gross Electric Generation (MWh) 0.0 0

55398130 018. Net Electric Generation (MWh)

-4705.0

-15106 53696514

19. Unit Service Factor 0.0 0.0 52.46
20. Unit Availability Factor 0.0 0.0 52.46
21. Unit Capacity Factor (MDC Net) 0.0 0.0 45.39
22. Unit Capacity Factor (DER Net) 0.0 0.0 45.39
23. Unit Forced Outage Rate 100.0 100.0 36.92
24. Shutdowns Scheduled Over Next 6 Month (Type, Date, and Duration of Each):
25. If Shut Down At End Of Reporting Period, Estimated Date Of Startup:

CRevision g8 B2 9

9 R

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-259 Unit One DATE 04-01-87 COMPLETED BY J.D. Crawford TELEPHONE (205)729-2507 MONTH March 1987*

DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1

-7 17

-6 2

-7 18

-7 3

-6 19

-7 4

-7 20

-7 5

-6 21

-6 6

-6 22

-6 7

-6 23

-6 8

-7 24

-6 9

-7 25

-7 10

-10 26

-6 11

-5 27

-6 12

-6 28

-6 13

-7 29

-7 l

14

-7 30

-3 15

-6 31

-3 16

-6 INSTRUCTIONS l

On this format, list the average daily unit power level in MWe-Net for cach day in the reporting month. Compute to the nearest whole megawatt.

  • Complete Revision (9/77)

L.

tva 0:24 con #4SI)

NUCLEAR PLANT OPERATING STATISTICS Browns Ferry Nuclear Plan t Period Hours

'744 Month Mnrch 19 87 Item No.

Unit No.

U-l U-2 U-3 Plant 1

Averace Hourly Cross Load, kW 0

0 0

0 2

Maximum Hour Net Generation. MWh 0

0 0

0

_ 3 C' ore Thermal Energy Gen. GWo (tP 0

0 0

0 4

Steam Gen. Therrrial Energy Gen., GWO 412 8

5 Gross Electrical Gen., MWh

.. 0 0

0 0

6 Station Use. MWh 4705

  • 3203 2386 10,297*

7 Net Electrical Gen., MWh

-4705 "

-3203

-2386

-10,'297*

~

b 8

Station Use, Percent 0

0 0

0 9

Accum. Core Avg. Exposure. MWD /TonI O

O O

O

~

10 CTEG This Month.1068TU 0

0 0

0 6

11 SGTEG This Month.10 BTU 12

^

13 Hours Reactor Was Critical 0

0 0

0 14 Unit Use, Hours. Min.

0 0

0 0

15 Capacity Factor, Percent 0

0 0

0 3

16 Turbine Avail. Factor Percent 0

0 100 33.3 17 Generator Avail. Factor. Percent 0

0 100 33.3 18 Turbooen. Avail Factor. Percent 0

0 100 33.3 19 Reactor Avait. Factor. Percent 0

0 100 33.3 2

20 Unit Avail. Factor. Percent 0

0 0

0 21 Turbine Startuos 0

0 0

0 22 Reactor cold Startuos 0

0 0

0

?3 3

24 Gross Heat Rate, Btu /kWh 0

0 0

0 25 Net Heat Rato, Blu/kWh 0

0

.E 26 0

0 0

27 g

28 TMottle Pressure, osig 0

0 0

0 e

29 Throttle Temperature, *F 0

0 0

0

.,5 30 Exhaust Pressure. InHg Abs.

0 0

0 0

.E 31 Intake Water Temo., *F 0

0 0

0 H

32 33 Main Feedwater. M ib/hr a

y 34

~

h 35 36 37 Full Power Capacity. EFPO (3) 4 4

4 38 Accum. Cycle Full Power Days. EFPO 4

4 4

j 39 Oil Fired for Generation, Gallons 627 E

40 Oi! Heatino Value. 8tu/ Gal.

139.500 t

41 0:+1eJ Generation. MWh 25,2

.t s l

Max. Hour Net Gen.

Max. Day Net Gen-Load VWh Time Date MWh Date Factor, %

2 43 0

0 0

S Remarks: IFor GFNP this value is MWD /STU and for SONP and WBNP this value is MWD /MTU.

2(t) indicates Thermal Energy.

o I

j (3) Information furnished by Reactor Analysis Group. Chattanooca (4) Administrative Hold

  • Revision i

^4M DJte Submitted Date Revised

.s.,

,'Y Plant Sq:)c6nte-S ent i