OPERATING DATA REPORT DOCKET'NO.

50-259 DATE FEBRUARY 87 -

PREPARED BY S.A.RATLIFF TELEPHONE 205-729-2937 OPERATING STATUS 1.

Unit. fame: BROWNS FERRY UNIT ONE

2. Reporting period: FEBRUARY, 1987
3. Licensed Thermal Power (MWt). 3293 4

Nameplate Rating (Gross MWe). 1152 5.

Design Electric Rating (Net MWe): 1065

6. Maximum Dependable Capacity (Gross MWe): 1098.4
7. Maximum Dependable Capacity (Net MWe): 1065
8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reason: N/A
9. Power Level To which Restricted, If Any (Net MWe): N/A
10. Reason For Restrictions, If Any: N/A THIS YEAR-TO MONTH DATE CUMULATIVE
11. Hours In Reporting Period 672.0 1416

.110336

12. Hours Reactor Was Critical 0.0 0

59521

13. Reactor Reserve Shutdown Hours 0.0 0

6997

14. Hours Generator On Line 0.0 0

58267

15. Unit Reserve Shutdown Hours 0.0 0

0

16. Gross Thermal Generation (MWh) 0.0 0

168066707

17. Gross Electric Generation (MWh) 0.0 0

55398130

  • 18. Net Electric Generation (MWh)

-4842.0

-10401 53701219

19. Unit Service Factor 0.0 0.0 52.81
20. Unit Availability Factor 0.0 0.0 52.81
21. Unit Capacity Factor (MDC Net) 0.0 0.0 45.70
22. Unit Capacity Factor (DER Net) 0.0 0.0 45.70
23. Unit Forced Outage Rate 100.0 100.0 36.41
24. Shutdowns Scheduled Over Next 6 Month (Type, Date, and Duration of Each):
25. If Shut Down At End Of Reporting Period, Estimated Date Of Startup:
  • Rsvision 8008290331 880015 DR ADOCK 0000 9

6

-n-

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-259 Unit One DATE 03-01-87 COMPLETED BY K.L. Creamer TELEPHONE (205)729-2960 MONTH February 1987*

DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1

-8 17

-7 2

-7 18

-8 3

-7 19

-8 4

-8 20

-7 5

-8 21

-7 6

-7 22

-7 7

-8 23

-6 8

-8 24

-6 9

-8 25

-8 10

-8 26

-5 11

-8 27

-7 12

-7 28

-7 13

-7 29 14

-7 30 15

-7 31 r

16

-7 INSTRUCTIONS On this format, list the average daily unit power icvel in MWo-Not for each day in the reporting month.

Compute to the nearest whole megawatt.

  • Completo Revision (9/77)

TV A M8 2 A (ONP+8 0 NUCLEAR PLANT OPERATING STATISTICS Browns Ferrv Nuclear Plant Period Hours 672 Month February 19 87 ltem No.

Unit No.

U-l U-2 U-3 Plant 1

Averace Hourly Gross Load. kW 0

0 0

0 2

Maximum Hour Net Generation. M9/h 0

0 0

0 3

Core Thermal Energy Gen. GWD (t)2 0

0 0

0 4

Steam Gen. Thermal Energy Gen., GWD (t)2 8

5 Gross Electrical Gen., MWh 0

0 0

0 f

6 Station Use, MWh 4842

  • 1426 2453 8849
  • 7 Net Electrical Gen., MWh

-4842 *

-1426

-2453

-88_49

  • h 8

Station Use, Percent 0

0 0

0 9

Accum. Core Avg. Exposure. MWD / Ton 1 0

0 0

0 10 CTEG This Month.106 BTU O

0 0

0 6

11 SGTEG This Month,10 BTU 12 13 Hours Reactor Was Critical 0

0 0

0 14 Unit Use. Hours Min.

0 0

0 0

15 Capacity Factor, Percent 0

0 0

0 y

16 Turbine Avail. Factor. Percent 0

0 100 33.3 17 Generator Avail. Factor. Percent 0

0 100 11.1 g

C 18 Turbooen. Avail, Factor. Percent 0

0 l_00 33.1 19 Reactor Avail. Factor. Percent O

O 100 11_1 E

20 Unit Avail. Factor. Percent 0

0 0

0 21 Turbine Startuos 0

0 0

0 22 Reactor Cold Startuos 0

0 0

0

?1 3

24 Gross Heat Rate,8tu/kWh 0

0 0

0

.{

25 Net Heat Rate, Btu /kWh 0

0 0

0

.4 26 U

27 g

28 Throttle Pressure, osig 0

0 0

0 d'

29 Throttle Temperature, 'F 0

0 0

0 y

30 Exhaust Pressure, inHg Abs.

0 0

0 0

E 31 Intake Water Temo., *F 0

0 0

0 H

32 33 Main Feedwater, M lb/hr

(

y 34 l

35 36 37 Full Power Capacity, EFPD (3) 4 4

4 38 Accum. Cycle Full Power Days. EFPD 4

4 4

j 39 Oil Fired for Generation, Gallons 516 2

40 Oil Heatino Value. Btu / Gal.

138.800 41 Diesd Generation. MWh 21.0 0

Max. Hour Net Gen.

Max. Day Net Gen.

Load MWh Time Date MWh Da te Factor. %

3 43 0

0 0

O Remarks: IFor OFNP this value is MWD /STU and for SONP and WBNP this value is MWD /MTU.

j 2(t) indicates Thermal Energy.

i 3

(3)

Information furnished hv Donctor Anniveie Crnon. chatennnnen (4)

Administrative hold 1

l l

Revisiomf/

/

j l

Date Submitted-9/d D Date Revised g

30

..._.e.._....-._.

n