1 i

(

TROJAN NUCLEAR PLANT s

Defueled Safety Analysis Repon. Revision 4 The following information is furnished as a guide for inserting new pages for Revision 4 into the Trojan Nuclear Plant Defueled Safety Analysis Report. This changes are denoted by the use of revision bars in the margin and revision number in the lower outside corner of the page.

Revised pages should be inserted as listed below:

Insert Delete (Front /Back)

(Front /Back) i/ii through xxvii/xxviii ilii through xxvii/ blank l.21/1.22 1.2-1/1 2-2 1.4-1/l.4-2 through 1.4-5/1.4-6 1.4-1/l.4-2 through 1.4-5/ blank 1.5-1, blank 1.5-1/ blank 2.2-7/2.2-8 2.2-7/2.2-8 2.2-9/2.2-10 2.2-9/2.2-10 l]

2.4-31/2.4-32 2.4-31/2.4-32 2.5-13/2.5-14 2.5-13/2.5-14 3.1-7/3.1-8 3.1-7/3.1-8 3.2-1/3.2-2 3.2-1/3.2-2 3.2-5/3.2-6 through 3.2-41/ blank 3.2-5/3.2-6 through 3.2 39/3.2-40 3.3-1/3.32 3.3-1/3.3-2 3.3-3/3.3-4 3.3-3/3.3-4 3.3-7/3.3-8 33-7/31 8 3.3-11/3.3-12 3.3-11/3.3-12 3.3-15/3.3-16 3.3-15/3.3-16 3.4-1/3.4-2 3.4-1/3.4-2 3.4-3/3.4-4 3.4-3/3.4-4 Table 3.1-3/ Table 3.1-4 Table 3.1-3frable 3.1-4 Table 3.5-1, Sheets 1/2 of 38 Table 3.5-1, Sheets 1/2 of 38 Table 3.5-1, Sheets 9/10 of 38 Table 3.5-1, Sheets 9/10 of 38 through 15/16 of 38 through 15/16 of 38 Figures 3.2-15/ blank through 3.2-22/ blank Figures 3.2-15/ blank through 3.2-22/blark Figure 3.3-2< blank Figure 3.3-2/ blank Figure 3.3-3/ blank Figure 3.3-3/ blank

(

4.0-1/4.0-2 4.0-1/4.0-2 9612050047 961127 PDR ADOCK 05000344 K

PDR

th

(

Insert Delete t Front, Back)

(Fronte Back) 4.21/4 2-2 and 4 2-3, blank 4.2-1/4.2-2 and 4.2-3, blank 4.3-3/4.3-4 4.3-3/4.3-4 4.3-5/4.3-6 4.3-5/4.3-6 4.4-1/ blank 4.4-1/ blank 4.5-liblank 4.5-leblank Table 4.1-1, Page 1 of 2/ blank Table 4.1-1, Page 1 of 2/ blank Figure 4.2-1/ blank Figure 4.2-1/ blank Figure 4.2-2sblank Figure 4.2-2/ blank 6.3-5/6.3-6 6.3-5/5.3-6 6.3-7. blank 6.3-7, blank 6.41/6.4-2 6.4-1/6.4-2 7.1-1/7.1-2 and 7.1-3/7.1-4 71-1/7.1-2 and 7.1-3/7.1-4 7.5-l/ blank 7.5-1/ blank In addition to the above changes, delete the entire contents of your DSAR Interim Update LDCR binder.

O

\\J

(~~%

V) i

i TABLE OF CONTENTS OFFIIFT FD SAFFTY ANAI_YSIS RFPORT CHAPTER 1.0 3

INTRODUCTION AND

SUMMARY

Sectinn Tirle Page

1.0 INTRODUCTION

AND SL31 MARY 1.0-1 i

1.1 Introductinn......

1.1-1 1.2 Generni Pinnt Decerintion 1.2-1 i

4 l

1.2.1 Desiga lateria.....

1.2-1 i

1.2.2 Fuel Handling System 1.2-2 1.2.3 Radioactive Waste Treatment Systems...

1.2-2 i

1.3 Identificnrinn nf Agenre,cd enntenctnrs 1.3-1 1.3.1 Design of the Facility..............................

1.3-1 1.4 Frc!ncinns fenm and Fremr rinnt in certain Pnrts nf Title 10 nf the ende of Federal Reoulatinne (10 CFR) 1.4-1

]

1.4.1 Exclusions from Certain Parts of 10 CFR.................

1.4-1 1.4.1.1 10 CFR 26, Fitness for Duty Program.................

1.4-1 1.4.1.2 10 CFR 50.44, Standards for Combustible Gas Control i

System in Light-Water. Cooled Power Reactors...........

1.4-1 j

1.4.1.3 10 CFR 50.46, Acceptance Criteria for Emergency Core j

{

Cooling Systems for Light-Water Nuclear Power Reactors....

1.4-2 l

i 1.4.1.4 10 CFR 50.48, Fire Protection......................

1.4-2 1.4.1.5 10 CFR 50, Appendix R, Fire Protection Program for Nuclear Power Facilities Operating Prior to January 1,1979..

1,4-2 i

1.4.1.6 10 CFR 50.49, Environmental Qualification of Electrical Equipment Important to Safety for Nuclear Power Plants 1.4-2 l

1.4.1.7 10 CFR 50.55a, In-Service Inspection Requirements........

1.4-3 l

1.4.1.3 10 CFR 50.60. Acceptance Criteria for Fracture Prevention Measures for Light-Water Nuclear Power Reactors........

1.4-3 10 CFR 50.61. Fracture Toughness Requirements for 1.4.1.9 j

Protection Against Pressurtzed Thermal Shock Events......

1.4-3 i

i Revision 4 1

l 1

I l

l 1

CHAPTER

1.0 INTRODUCTION

AND SUNihfARY Sectinn Title

_p3 g 1.4.1.10 10 CFR 50, Appendix G. Fracture Toughness Requirements..

1.4-3 1.4.1.11 10 CFR 50, Appendix H, Reactor Vessel hiaterial l

Surveillance Program Requirements.

1.4-4 1.4.1.12 10 CFR 50.62, Requirements for Reduction of Risk from Anticipated Transients Without Scram (ATWS) Events for Light-Water-Cooled Nuclear Power Plants.

1.4-4 1.4.1.13 10 CFR 50.63, Loss of All Alternating-Current Power.......

1.4-4 l 1.4.1.14 10 CFR 50.71(e), Staintenance of Record, hiaking of Reports..

1.4-5 l 1.4.1.15 10 CFR 70.24, Criticality Accident Requirements....

1.4-5 1.4.2 Exemptions to 10 CFR Related to the Permanently Defueled Condition 1.4-5 1.4.2.1 10 CFR 50.54(o) and Appendix J. Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors.....

1.4-5 h

l 1.4.2.2 10 CFR 50.54(y), Conditions of Licenses.....

1.4-6 l 1.4.2.3 10 CFR 50.54(q) and Certain Sections of 10 CFR 50.47, l

' Emergency Plans,"....

1.4-6 i

1.5 Ninterini incnmornred by Reference 1.5-1 1

l l

Revision 4 ii

8 f

l i

1 l

\\

CHAPTER 2.0 SITE CHARACTERISTICS I

Rectinn Title Page i

i 2.0 SITE CHARACTERISTICS..........................

'2.0-1 2.1 Gencen.nh.v 'nd ihmn.orn.nh.v 2.1-1 2.1.1 Site Location and Description.........................

2.1-1 2.1.1.1 Specification of Location.

2.1-1 2.1.1.2 Site Area Map 2.1-2 2.1.1.3 Boundaries for Establishing Effluent Release Limits.........

2.1-3 l

2.1.2 Exclusion Area Authority and Control....

2.1-3 l

2.1.2.1 A u tho rity....................................

2.1-3 l

2.1.2.2 Exclusion Area Activities Unrelated to Plant Operation.......

2.1-4 2.1.2.3 Arrangements for Traffic Control....................

2.1-5 l

j 2.1.3 Population Distribution.............................

2.1-6 l

/^

2.1.3.1 Popula: ion Within 10 Miles........................

2.1-6

\\

2.1.3.2 Population Between 10 and 50 Miles..................

2.1-8 2.1.3.3 Transient Population 2.1-8 2.1.3.4 Low-Population Zone............................

2.1-9 2.1.3.5 Population Center..............

2.1-10 2.1.4 Uses of Adjacent Lands and Waters.....................

2.1-10 2.2 Nearby traimtrial: Trnn<nnrnrinn and and Militarv Fncilitiec.....

2.2-1 2.2.1 Locations and Routes..............................

2.2-1 l

2.2.2 Descriptions....................................

2.2-4 2.2.2.1 Description of Products and Materials 2.2-4 2.2.2.2 P ipe lines....................................

2.2-5 2.2.2.3 Waterways...................................

2.2-6 2.2.2.4 A irports....................................

2.2-6 1

2.2.3 Evaluation of Potential Accidents......................

2.2-7 2.2.3.1 Explosions.......................

2.2-7 2.2.3.2 Toxic Chemicals...............................

2.2-17 2.2.3.3 Fires 2.2-19

)

[

2.2.3.4 Ship Collision with Intake Structure...................

2.2-20 2.2.3.5 Oil or Corrosive Liquid Spills in River 2.2-21 iii Revision 4 1

I

CHAPTER 2.0 SITE CHARACTERISTICS herinn Tirte p,ge 2.2.3.6 Cooling Tower Collapse..........................

2.2-22 2.3 Merenrningy 2.3-1 2.3.1 Regional Climatology...............

2.3 1 2.3.1.1 General Climate 2.3 1 2.3.1.2 Regional Meteorological Conditions for Design and Operation Bases......

2.3-1 2.3.2 Local Meteorology 2.3-2 2.3.2.1 Normal and Extreme Values of Meteorological Parameters....

2.3-2 2.3.2.2 PotentialInfluence of the Plant and its Facilities On Local Meteorology 2.3-4 2.3.2.3 Local meteorological Conditions for Design and Operation Bases.......................

2.3-5 O

2.3.3 Onsite Meteorological Measurements Program..............

2.3-6 2.3.3.1 Past Meteorological Facility Operations 2.3-6 2.3.3.2 Measurements........

2.3-7 2.3.4 Diffusion Estimates......

2.3-8 2.4 Hydrningic Fngineering............................

2.4-1 2.4.1 Hydrologic Description...........

2.4-2 2.4.1.1 Site and Facilities..............................

2.4-2 2.4.1.2 Hydrosp here..................................

2.4-2 2.4.2 Floods 2.4-3 2.4.2.1 Flood History.................................

2.4-3 2.4.2.2 Flood De:ign Consideratin:s...

2.4-4 2.4.2.3 Effects of Local Intense Precipitation..................

2.4-5 2.4.3 Probable Maximum Flood of Streams and Rivers............

2.4-5 2.4.3.1 Probable Maximum Precipitation.....

2,4-5 2.4.3.2 Precipitation Losses.............................

2.4-8 2.4.3.3 Runoff Model.................

2.4-9 2.4.3.4 Probable Maximum Flood Flow.....................

2.4-12 Revision 4 iv

m

.r 1

(

CHAPTER 2.0 SITE CHARACTERISTICS l

Rection Title Page i

l 2.4.3.5 Wat:r level Determinations........

2.4-18 2.4.3.6 Coincident Wind Wave Activity......

2.4-19 2.4.4 Potential Dam Failures.............................

2.4-20 2.4.4.1 Seismically Induced Dam Failure 2.4-20 l

2.4.4.2 Volcanically Induced Dam Failure....................

2.4-22 2.4.4.3 Spirit Lake Blockage Failure 2.4-25 2.4.5 Probable Maximum Surge Flooding.....................

2.4-29 2.4.5.1 Surge Water Levels.............................

2.4-29 2.4.5.2 Re s o nanc e..............................

2.4-30 2.4.6 Probable Maximum Tsunami Flooding...............

2.4-31 2.4.7 Ic e E ffec ts.....................................

2.4-31 2.4.8 Cooling Water Canals and Reservoirs....................

2.4-32 2.4.9 Channel Diversions...............................

2.4-32 2.4.10 Flooding Protection Requirements......................

2.4-32 2.4.11 Low Water Considerations...........................

2.4-33 2.4.12 Dispersion, Dilution, and Travel Times of Accidental Releases of Liquid Effluents in Surface Waters.............

2.4 33 2.4.13 Groundwater...................................

2.4-34 2.4.13.1 Description and Onsite Use........................

2.4-34 2.4.13.2 Sources.....................................

2.4-35 2.4.13.3 Accident Effects...............................

2.4-36 2.5 Geninav Reicmninav and Gentachnient Fnaineerina 2.5-1 2.5.1 Basic Geologic and Seismic Information..................

2.5-1 l

2.5.1.1 Regiona.' Geology.......

2.5-2 2.5.1.2 Site Geology 2.5-4 v

Revision 4

1 l

OI CHAPTER 2.0 SITE CHARACTERISTICS Section Title Age.

2.5.2 Vibratory Ground Motion..........

2.5-8 2.5.2.1 Seismicity......

2.5-8 2.5.2.2 Geologic Structures and Tectonic Activity........

2.5-8 2.5.2.3 Maximum Earthquake Potential 2.5-9 2.5.2.4 Seismic Margin Earthquake, Safe Shutdown Earthquake

{

and Operating Basis Eanhquake 2.5-11 2.5.3 Surface Faulting.....

2.5-13 2.5.3.1 Geologic Condition of the Site 2.5-13 2.5.3.2 Investigation for Capable Faults..

2.5-14 2.5.3.3 Description of Faults.......

2.5-16 2.5.4 Stability of Subsurface Materials and Foundations...........

2.5-28 2.5.4.1 Foundation Evaluation.

2.5-29 2.5.5 Stability of Slopes..

2.5-33 2.5.6 Volcanology..........

2.5 33 2.5.6.1 Volcanoes in General Area 2.5-34 2.5.6.2 Possible Hazards of the Cascade Volcanoes..............

2.5-38 2.5.6.3 Hazards from Future Volcanic Activities................

2.5-39 2.5.6.4 Summary and Conclusions.........................

2.5-47 2.6 R e fe re nc e c.....................................

2.6-1 Revision 4 vi

I l

CHAPTER 3.0 FACILITY DESIGN i

Section Title lage.

3.0 FACILITY DESIGN.

3.0-1 3.1 S u m m a rv......................................

3.1-1 3.1.1 Conformance with NRC General Design Criteria 3.1-1 3.1.2 Classification of Structures, Components and Systems.........

3.1-7 3.1.3 Wind and Tornado Loadings 3.1-7 3.1.3.1 Wind Loadings.....

3.1-8 3.1-8 3.1.3.2 Tornado Loadings............................

3.1.4 Water level (Flood) Design..........................

3.1-13 3.1.5 5 fissile Protection Criteria...........................

3.1-14

)

3.1.5.1

- Stissile Selection and Description 3.1-14 3.1.6 Seismic Design..................................

3.1-15 3.1.6.1 Seismic Design Parameters 3.1-15 3.1.6.2 Seismic System Analysis..........................

3.1-19 3.2 Spe nr Fue1 Renn ge................................

3.2-1 3.2.1 Control, Auxiliary, and Fuel Building Complex.............

3.2-1 3.2.1.1 Description..................................

3.2-1 3.2.1.2 Design Bases.................................

3.2-6 3.2.1.3 Applicable Codes, Standards, and Specification...........

3.2-8 l

3.2.1.4 Loads and Load Combinations......................

3.2-13 l

3.2.1.5 Design and Analysis Procedures.....................

3.2-19 l

3.2.1.6 Structural Acceptance Criteria 3.2 28 l

3.2.1.7 Staterials, Quality Control and Special Construction Techniques..................................

3.2-30 l

3.2.1.8 Testing and Inservice Inspection Requirements............

3.2-34 l

3.2.1.9 Foundations..................................

3.2-34 3.2.2 Spent Fuel Pool and Fuel Storage Racks..

3.2-35 l

(

3.2.2.1 Design Bases.................................

3.2-35 l

vii Revision 4

CHAPTER 3.0 FACILITY DESIGN Srcrinn Title page l 3.2.2.2

System Design

3.2 37 l 3.2.2.3 Design Evaluation..........................

3.2 39 l 3.2.2.4 Tests and Inspections...............

3.2-39 l 3.2.2.5 Instrumentation Application........................

3.2-40 3.2.2.6 SFP Structure Re. evaluation for Beyond l

Design Basis Seismic Motions......

3.2-40 3.3 Anviliarv systems 3.3-1 3.3.1 Fuel Handling System 3.3-1 3.3.1.1 Design Bases 3.3-1 3.3.1.2

System Description

3.3-2 3.3.1.3 Design Evaluation.

3.3-4 3.3.2 SFP Cooling and Demineralizer System 3.3-5 3.3.2.1 Design Bases 3.3-5 3.3.2.2

System Description

3.3-6 3.3.2.3 Design Evaluation........

3.3-8 3.3.3 Component Cooling Water System 3.3-8 3.3.3.1 Design Bases..........

3.3-9 3.3.3.2

System Description

3.3-9 3.3.3.3 Design Evaluation..............................

3.3-11 3.3.4 Service Water System..............................

3.3-12 3.3.4.1 Design Bases.................................

3.3-12 3.3.4.2 System Description.............................

3.3-13 l

3.3.4.3 Design Evaluation..............................

3.3-14 3.3.5 Compressed Air System............................

3.3-15 3.3.6 Boric Acid Batch Tank.............................

3.3-16 3.3.7 Makeup Water Treatment System......................

3.3-16 3.3.8 Equipment and Floor Drain Systems 3.3-16 Revision 4 viii

O CHAPTER 3.0 s

FACILITY DESIGN l

Rectinn Title g

i 3.3.9 Plant Discharge and Dilution Structure...................

3.3-17 3.3.10 Primary Sampling System...........................

3.3-18 l

3.3.11 Fire Protection System and Program....................

3.3-19 3.3.12 Control Room Habitability...........................

3.3-19 3.3.13 Seismic Instrumentation..............

3.3-19 3.4 Flectric Pnwer 3.4 1 3.4.1 Offsite Power System..............................

3.4-1 j

3.4.1.1 Description 3.4-1 3.4.1.2 Analysis.....

3.4-2

)

3.4.2 Onsite Power Systems 3.4-2 s-3.4.2.1 D e sc rip tio n..................................

3.4-2 3.4.2.2 Analysis.....................

3.4-4 3.5 Comnliance with NRC Remilstnry Guidec.................

3.5-1 3.6 Referenca<

3.6-1 O

ix Revision 4 1

j CHAPTER 4.0 OPERATIONS l

i herion Title g

l 4.0 OPERATIONS...

4.0-1 4.1 Opernrinn Description.............

4.1-1 l

l 4.1.1 Criticality Prevention..............................

4.1-1 4.1.2 Chemistry Control......

4.1-2 4.1.3 Instrumentation.................

4.1-2 4.1.3.1 Seismic hionitoring Instnimentation 4.1-3 4.1.4 Staintenance Activities...

4.1-4 i

4.1.5 Administrative Control of Systems 4.1-4 4.2 Spent Fuel Hnndling 4.2 1 4.2.1 Spent Fuel Receipt, Handling, and Transfer..........

4.2-1 4.2.1.1 Functional Description 4.2-1 4.2.1.2 Safety Features....

4.2-2 4.2.2 S pent Fuel S to ra ge................................

4.2-3 4.3 Spent Fuel Cnnling and Runnnrr Syctemt 4.3-1 4.3.1 Spent Fuel Pool Cooling....................

4.3-1 4.3.1.1 Off-Normal Operation of the Spent Fuel Cooling System 4.3-2 4.3.1.2 Loss of Spent Fuel Pool Level......................

4.3-2 4.3.1.3 Loss of Spent Fuel Pool Cooling.....................

4.3-3 4.3.1.4 High Spent Fuel Pool Level........................

4.3-4 4.3.1.5 Safety Criteria and Assurance.......................

4.3-4 4.3.2 Electrical Distribution 4.3-5 4.3.3 Support Systems...........

4.3-5 4.4 Contrni Rnmn Ares.....

4.4-1 4.5 Referencec..

4.5-1 Revision 4 x

CHAPTER 5.0 RADIATION PROTECTION sectinn Title page 5.0 RADIATION PROTECTION.

5.0-1 5.1 snurce Terms.

5.1-1 5.2 offgna Trentment and Ventilatina 5.2-1 5.2.1 Vent Collection System..

5.2-1 5.2.1.1 Desig n Bases....................

5.2-1 5.2.1.2

System Description

5.2-2 5.2.1.3 Design Evaluation.............

5.2 2 5.2.2 Containment Ventilation System..

5.2-3 5.2.2.1 Design Bases 5.2-3 5.2.2.2

System Description

5.2-3 5.2.2.3 Design Evaluation.

5.2-5 5.2.3 Fuel and Auxiliary Building Ventilation System.............

5.2-5

\\

5.2.3.1 Design Bases.................................

5.2-5 5.2.3.2

System Description

5.2-5 5.2.3.3 Design Evaluation..............................

5.2-6 5.3 i innia wacte Trentment and Retentinn 5.3-1 5.3.1 Clean Radioactive Waste System.......................

5.3-1 5.3.1.1 D e s ign Bases.................................

5.3-1 5.3.1.2 System Description.............................

5.3 2 5.3.1.3 Design Evaluation..............................

5.3-4 5.3.2 Dirty Radioactive Waste System.......................

5.3-5 5.3.2.1 Design Bases..

5.3-5 5.3.2.2 System Description.............................

5.3-6 5.3.2.3 Design Evaluation..............................

5.3-8 5.4 Enlid W a(rea 5.4-1 5.4.1 Design Bases 5.4-1

(.

xi Revision 4

CHAPTER 5.0 RADIATION PROTECTION Sectinn Title Ag 5.4.2 Sy stem Description...............................

5.4-2 5.4.2.1 Spent Resin Transfer System.......................

5.4-2 5.4.2.2 Filter Handling.

5.4-3 5.4.2.3 Solid Wastes 5.4-3 5.4.3 Design Evaluation...

5.4-3 5.5 Pyncesc nnd FfRuent \\innirnring Systemc 5.5-1 5.5.1 Design Bases.

5.5-1 5.5.2 System Description.

5.5-2 5.5.2.1 Liquid Monitoring Systems.

5.5-3 5.5.2.2 Gas Monitoring Systems 5.5-4 5.5.2.3 Analytical Procedures.

5.5-75.5.2.4 Calibration and Maintenance 5.5-8 O

5.5.3 Effluent Monitoring and Sampling.....................

5.5-9 5.5.4 Process Monitoring and Sampling......................

5.5-9 5.6 R nd i,rinn Prnrectinn Prngrnm.........................

5.6-1 5.6.1 Radiation Protection Design Features....................

5.6-1 5.6.1.1 Shielding Radiation Zoning and Access Control...........

5.6-1 5.6.1.2 Plant Ventilation Systems.........................

5.6-1 5.6.1.3 Area Radiation Monitoring Instmmentation..............

5.6-1 5.6.2 Equipment, Instrumentation and Facilities.................

5.6-2 5.6.2.1 Radiation Protation Facilities 5.6-3 5.6.2.2 Radiation Protection Instmmentation..................

5.6-4 5.6.3 Procedures.........

5.6-6 5.6.3.1 Control of Personnel Radiation Fxposure 5.6-6 5.6.3.2 Personnel Dosimetry...........................

5.6-8 5.6.3.3 Radioactive Materials Safety 5.6-9 Revision 4 xii

e E

CHAPTER 5.0 RADIATION PROTECTION i

i Rectinn Tirle g

i 5.7 EnmHng that Occupntinnni Rndiatinn Fvpcorret are n inw at it i

pe,cnnably Achievnble (Al AR A) 5.7-1 5.7.1 Po!!cy Considerations..............................

5.7-1 t

5.7.2 Design Considerations 5.7-1 5.7.3 Operational Considerations 5.7-1 5.8 cnttective nn<e Aueument....

5.8-1 5.9 Reference <..

5.9-1 i

xiii Revision 4

1 i

CHAPTER 6.0 ACCIDENT ANALYSIS Sectinn Title

.p4 6.0 Accident Annlysis 6.0-1 6.0.1 Fission Product Inventories........

6.0-1 6.0.1.1 Activities in the Core............................

6.0-2 6.0.1.2 Activities in the Fuel Pellet Cladding Gap...............

6.0-2 6.0.2 Radiological Evaluation Model.......

6.0-4 6.0.2.1 Assumptions.....

6.0-5 6.0.2.2 Whole Body Dose......

6.0-5 6.0.2.3 Thyroid Inhalation Dose.

6.0-7 6.0.2.4 Computer Code 6.0-8 6.1 Rndinnerive Relence from a Subsytrem nr C'nmnnnent 6.1-1 6.1.1 Radioactive Gas Waste System Leak or Failure..............

6.1-1 6.1.1.2 Assumptions or Conditions 6.1-2 6.1.1.3 Dose Results 6.1-2 6.1.2 Postulated Radioactive Releases Due to Liquid Tank Failures....

6.1-3 6.1.2.1 Identification of Causes and Accident Description..........

6.1-3 6.1.2.2 Dose Results 6.1-4 6.2 Euel mnaling Accident 6.2-1 6.2.1 Assumptions or Conditions...

6.2-1 6.2.2 Dose Results 6.2-3 6.3 S.nent Fuel Pnni A cc idente...........................

6.3-1 6.3.1 Loss of Spent Fuel Decay Heat Removal Capability...........

6.3-1 6.3.1.1 Potential Events Resulting in I.oss of Spent Fuel Decay Heat Removal Capability.................

6.3-1 6.3.2 Loss of Forced Spent Fuel Cooling Without Concurrent SFP Inventory Loss 6.3-4 Revision 4 xiv

i CHAPTER 6.0 L

ACCIDENT ANALYSIS Rectinn Title Page.

6.3.3 Loss of Forced Spent Fuel Cooling with Concurrent S FP Inventory Loss.............................

6.3-5 6.4 R e re re"""*

6.4-1 t

1 l

l l

l I

l 1

l i

xv Revision 4

O CHAPTER 7.0 CONDUCT OF OPERATIONS Section Title page 7.0 CONDUCT OF OPERATIONS..................

7.0-1 7.1 PG F Organintinnal Rrrncture............,..,,,..,,,.

7,1 1 l

I 7.1.1 Management and Technical Suppen Organization........

7.1-1 7.1.2 Nuclear Division.

7.1-1 7.1.2.1 Plant Organizations..........

7.1-1 7.1.2.2 Supponing Organizations 7.1-3 7.1.2.3 Review and Audit Organizations.......

7.1-5 l

7.2 Plant Prncedures 7.2 1 7.2.1 Procedures Related to Nuclear Safety..

7.2-1 7.2.2 Nuclear Division Manual 7.2 2 7.2.3 Plant Procedures......

7.2-3 7.2.3.1 Administrative Orders............

7.24 7.2.3.2 Operating Instructions..

7.24 7.2.3.3 Periodic Tests...............

7.24 7.2.3.4 Fuel Handling Procedures.........................

7.24 7.2.3.5 Maintenance Procedures...................

7.2-5 7.2.3.6 Radiation Protection Procedures.....................

7.2-5 7.2.3.7 Chemistry Procedures............................

7.2-5 7.2.3.8 Plant Safety Procedures...........................

7.2-6 7.2.3.9 Temporary Procedures...........................

7.2-6 7.3 Trnining 7.3-1 7.3.1 Training for Certified Fuel Handlers....................

7.3-1 7.3.2 Training for Plant Staff.............................

7.3-1 7.3.2.1 General Employee Training............

7.3-1 7.3.2.2 Fire Brigade Training............................

7.3-2 l

7.3.2.3 Other Training Programs........

7.3-2 l

r 7.4 Ernergency Plan 7,4-1 Revision 4 xvi

i 1

l 1

1 f

f O

LIST OF EFFEC r" a PAGES l

DFFITFT FD SAFETY ANAL _YSTR RFPORT i

)

Rectinn Effective Pngen Revmnn j

i Figures 3.1-1 through 3.1-19 N/A Rev.0 Figures 3.2-1 through 3.2-14 N/A Rev.O Figures 3.2-15 through 3.2-22 N/A Rev.4 Figures 3.2-23 through 3.2-30 N/A Rev.O Figure 3.3-1 N/A Rev.3 Figure 3.3-2 N/A Rev.4 Figure 3.3-3 N/A Rev.4 4.0 4.0-1 Rev.4 4.0 4.0-2 Rev.3 4.1 4.1-1 and 4.1-2 Rev.0 4.14.1 4.1-3 through 4.1-5 Rev.3 4.2 4.2-1 through 4.2-3 Rev.4

-l 4.3 4.3-1 and 4.3-2 Rev.0 0

4.3 4.3-3 Rev.4 4.3 4.3-4 Rev.0 4.3 4.3-5 and 4.3-6 Rev.4 4.4 4.4-1 Rev.4 4.5 4.5-1 Rev.4 Table 4.1-1, Page 1 N/A Rev.4 Table 4.1-1, Page 2 N/A Rev.3 Tables 4.3-1 N/A Rev.3 Figure 4.2-1 N/A Rev.4 Figure 4.2-2 N/A Rev.4 5.0 5.0-1 Rev.0 5.1 5.1-1 Rev.O i

5.2 5.2-1 through 5.2-7 Rev.O 5.3 5.3-1 through 5.3-8 Rev.O 5.4 5 i-1 through 5.4-4 Rev.0 5.5 5..i-1 Rev.0 5.5 5.5-2 through 5.5-9 Rev.3 5.6 5.6-1 Rev.1 5.6 5.6-2 Rev.3 5.6 5.6-3 Rev.0 O

uvii Revision 4

LIST OF EFFECTIVE PAGES DFFIIFI FD SAFFTY ANAI YSIS REPORT Sectinn Fffective Paget Revisinn 5.6 5.6-4 through 5.6-10 Rev.3 5.7 5.7-1 Rev.0 5.8 5.8-1 Rev. 0 5.9 5.9-1 through 5.9-2 Rev.O Tables 5.5-1 N/A Rev.3 Figures 5.2-1 through 5.2-6 N/A Rev.O Figures 5.3-1 through 5.3-3 N/A Rev.O Figure 5.4-1 N/A Rev.0 6.0 6.0-1 through 6.0-8 Rev.0 6.1 6.1-1 through 6.1-4 Rev.0 6.2 6.2-1 through 6.2-3 Rev.0 6.3 6.3-1 through 6.3-4 Rev.G-6.3 6.3-5 Rev.4 6.3 6.3-6 Rev.0 6.3 6.3-7 Rev.4 6.4 6.4-1 Rev.3 6.4 6.4-2 Rev.4 Tables 6.0-1 through 6.0-5 N/A Rev.O i

Tables 6.2-1 and 6.2-2 N/A Rev.O i

Tables 6.3-1 and 6.3-2 N/A Rev.O Figures 6.3-1 through 6.3-6 N/A Rev.0 7.0 7.0-1 Rev.3 7.1 7.1-1 Rev.4 l

7.1 7.1-2 Rev.3 7.1 7.1-3 and 7.1-4 Rev.4 7.1 7.1-5 Rev.3 7.2 7.2-1 and 7.2-2 Rev.3 7.2 7.2-3 through 7.2-6 Rev.0 7.3 7.3-1 and 7.3-2 Rev.3 7.3 7.3-3 Rev.0 7.4 7.4-1 Rev.0 7.5 7.5-1 Rev.4 7.6 7.6-1 Rev.3 8.0 8.0-1 Rev.0 h

9.0 9.0-1 Rev.O Revision 4 uviii

l l

1 1

CHAPTER 9.0 l

QUALITY ASSURANCE sectinn Tirte 3g 9.0 Q UALITY AS S URANC E...........................

8.0-1 1

l i

4 4

)

4

\\

l I

xix Revision 4 l

J

LIST OF TABLES DFFi?Fi FD SAFFTY ANAf YSIS RFPORT

_ Number Title 2.3-1 Trojan Cumulative Frequency Distribution of X Q Values

/

(September 1,1971 - August 31,1972) 2.3-2 Annual Average x /Q Values for Continuous Ground-Level Releases (Trojan Site Data September 1,1972 - August 31,1974) 2.3-3 Annual Average Deposition Values for Continuous Ground-Level Releases (Trojan Site Data September 1,1972 - August 31,1974) 2.3-4 Annual Average x /Q, Deposition and Plume Depletion Factor at Site Boundaries and Offsite Exposure Locations for Ground Level Releases (Trojan Site Data September 1,1972 - August 31,1974) 2.3-5 Sfaximum Annular Sector, Terrain Adjustment Factors Derived From NUSPUF With Building Wake Adjustment Divided by NUSOUT for Standard Population Distances of 0.5 Mile to 4.5 Afiles 2.3-6 Terrain Adjustment Factors Derived form NUSPUF With Building Wake Adjustment Divided by NUSOUT for Special Instances 3.1-1 Design Wind Loads 1

3,1-2 Capability of Structures to Withstand a Tornado 3.1-3 Locations of Gas Storage Tanks 3.1-4 Analyzed SFP Load Drops and Missiles 3.1-5 Damping Values, Percent Critical Damping l

3.1-6 Frequencies and Modal Effective Weights for Control Auxiliary, and Fuel l

Building Complex 3.1-7 Comparison of Maximum Accelerations from Time-History and Response Spectrum Analyses of the Unmodified Control Building Complex 3.2-1 Live Loads 3.2-2 Calculated Results - Fuel Building 3.2-3 Calculated Results - Auxiliary Building 3.2-4 Calculated Results - Control Building 3.2-5 Significant Elevations in the Spent Fuel Pool 3.5-1 List of Pertinent Regulatory Guides for Defueled Status 4.1-1 Seismic Monitoring Instmmentation 4.3-1 Spent Fuel Pool Chemistry Specification and Sampling Schedule 4

Revision 4 xx

.- -. = - -. - -

i l

O l

M LIST OF TABLES 4

DFFTTFT FD SAFFTY ANALYSIR RFPORT Number Title 5.5-1 Radiological Analysis Summary of Liquid Process Samples 6.0-1 Core and Gap Activities Based on Full Power Operation for 650 Days Full Power: 3565 MWt 6.0 2 Core Temperature Distribution 6.0-3 Breathing Rates 6.0-4 Physical Data for Isotopes 6.0-5 Accident Atmospheric Dilution Factors l

6.2-1 Input Data for Calculation of Site Boundary Doses of a Fuel Handling Accident 6.2-2 Resultant Doses from Fuel Handling Accident and Comparison with 10 CFR 100

[

6.3 1 Spent Fuel Pool P'erformance During Loss of Forced Cooling

\\

6.3-2 Dose Rates at Spent Fuel Pool at Reduced Water Levels l

j I

+.

xxi Revision 4

i UST OF FIGURES DFFTII:T FD SAFFTY ANAT YSIS RFPORT Number Tirfe 1.1-1 Facility Location 3.1-1 Design Response Spectra Operating Basis Earthquake 3.1-2 Design Respotise Spectra Safe Shutdown Earthquake 3.1-3 Synthetic Acceleration Time History Normalized to 1.0 g 3.1-4 Comparison of the Acceleration Response Spectrum of the Synthetic Time History With the Trojan Design Spectmm for 1% Damping 3.1-5 Comparison of the Acceleration Response Spectmm of the Synthetic Time History With the Trojan Design Spectrum for 2% Damping 3.1-6 Comparison of the Acceleration Response Spectmm of the Synthetic Time History With the Trojan Design Spectrum for 5% Damping 3.1-7 Comparison of the Acceleration Response Spectrum of the Synthetic Time History With the Trojan Design Spectrum for 7% Damping 3.1-8 Finite Element Sfodel - Control, Auxiliary, and Fuel Building 3.1-9 North - South Horizontal Response Spectra for Control Building Elevrions 61 feet 0 inch and 65 feet 0 inch 3.1-10 North - South Horizontal Response Spectra for Auxiliary Building Elevation 61 feet 0 inch 3.1-11 North - South Horizontal Response Spectra for Fuel Building Elevation 61 feet 0 inch 3.1-12 North - South Horizontal Response Spectra for Control Building Elevation 117 feet 0 inch 3.1-13 North - South Horizontal Response Spectra for Auxiliary Building Elevation 117 feet 0 inch 3.1-14 East - West Horizontal Response Spectra for Control Building Elevations 61 feet 0 inch and 65 feet 0 inch 3.1-15 East - West Horizontal Response Spectra for Auxiliary Building Elevation 61 feet 0 inch 3.1-16 East - West Horizontal Response Spectra for Fuel Building Elevations 61 feet 0 inch 3.1-17 East - West Horizontal Response Spectra for Control Building Elevation 117 feet 0 inch 3.1-18 East - West Horizontal Response Spectra for Auxiliary Building Elevation 117 feet 0 inch 3.1-19 3-D hiodel for the Fuel Building Steel Superstructure 1

3.2-1 Fuel Building - Plan Elevation 45' Revision 4 xxi!

l i

l i

I

(

LIST OF FIGL~RES l

DFFI'FT FD RAFFTY ANAf YSIS RFPORT l

l Number Title l

3.2 2 Spent Fuel Pool - Typical D(tails 3.2-3 Auxiliary Building - Plan Elevation 45' 3.2-4 Auxiliary Building - Plan Elevation 45', Containment Abutment 3.2-5 Fuel Building - Plan Elevation 66' 3.2-6 Auxiliary Building - Plan Elevation 61' 3.2-7 Typical Section Through Auxiliary and Fuel Buildings 3.2-8 Typical Steel Framing 3.2-9 Typical Steel Column Details 3.2-10 Floor Plans Showing Modifications 3.2-11 Control Building Floor Plan EL 45'-0" Showing Existing and Shear Walls 3.2 12 Control Building Floor Plan EL 61'-0" & 65'-0" Showing Existing and Shear Walls 3.2-13 Control Building Floor Plan EL 77'-0" Showing Existing and Shear Walls 3.2-14 Control Building Floor Plan EL 93'-0" Showing Existing and Shear Walls

/3 3.2-15 Equipment Location, Reactor and Auxiliary Buildings - Plan Below h

Ground Floor 3.2-16 Equipment Location. Reactor and Auxiliary Buildings - Plan Operating Floor, Elevation 45' 3.2 17 Equipment Location, Reactor and Auxiliary Buildings - Plan Elevation 61' 3.2-18 Equipment Location, Reactor and Auxiliary Buildings - Plan Elevation 77' 3.2-19 Equipment Location, Reactor and Auxiliary Buildings - Plan Operating Floor and Above l

3.2-20 Equipment Location, Reactor and Auxiliary Buildings - Section A-A 3.2-21 Equipment Location, Reactor and Auxiliary Buildings - Sections B-B, D-D, E-E, F-F 3.2-22 Equipment Location, Reactor and Auxiliary Buildings - Sections C-C and F F i

3.2-23 Containment Stmeture Typical Details 3.2-24 Containment Structure Typical Liner Plate Details 3.2-25 Containment Stmeture Base Slab Bottom Reinforcing 3.2-26 Containment Stmeture Base Slab Top Reinforcing 3.2-27 Containment Stmeture Wall Reinforcing i

3.2-28 Containment Stmeture Dome 3.2-29 Containment Structure Typical Penetration Details 3.2-30 Containment Structure Prestressing Tendons at Equipment Hatch 3.3-1 Fuel Pool Cooling and Demineralizer System xxiii Revision 4 l

l

1 1

l LIST OF FIGURES DFFI'FT FD SAFFTY ANAT.YSIS RFPORT Number Title 3.3-2 Component Cooling Water 3.3-3 Service Water System 4.2-1 Spent Fuel Storage Pool 4.2-2 Plant Arrangement Diagram of Fuel Cask Movement Envelope j

5.2-1 Gaseous Radioactive Waste System 5.2-2 Containment Purge Supply System (CS-1) 5.2-3 Containment Purge Exhaust System (CS-2) 5.2-4 Fuel / Auxiliary Building Ventilation Supply System (AB-2) 5.2-5 Fuel / Auxiliary Building Ventilation Exhaust System (AB-3) 5.2-6 SFP Ventilation Exhaus: System (AB-4) 5.3-1 Clean Radioactive Waste System 5.3.2 Dirty Radioactive Waste System 5.3-3 Liquid Radwaste Demineralizers 5.4-1 Solid Radioactive Waste System 6.1-1 Waste Gas Storage Tank Rupture Whole Body (Beta plus Gamma) Dose 6.3-1 Decay Heat Generated from Stored Fuel 6.3-2 SFP Heatup Rate versus Time After Reactor Shutdown 6.3-3 Time for SFP to Boil Upon Loss of Forced Cooling 6.3-4 SFP Boil Off Rate Without Makeup versus Time After Reactor Shutdown 6.3-5 Makeup Rate to Maintain SFP Level During Boil Off versus Time After Reactor Shutdown 6.3-6 Boil Off Time to 10 Feet Above Fuel Versus Time After Reactor Shutdown O

Resision 4 xxiv

l I

1 l

f l

O LIST OF EFFECTIVE PAGES i

DFFITFT FD SAFFTY ANAT YSIS REPORT ocrinn Effective Pnget Revicinn Title Page N/A Rev.O Table of Contents i - uiv Rev.4 i

List of Effective Pages uv - uviii Rev.4 i

1.0 1.0-1 Rev.0 l

1.1 1.1-1 Rev.0 1.2 1.2-1 Rev.0 1.2 1.2-2 Rev.4 1.3 1.3-1 Rev.0 1.4 1.4-1 through 1.4-6 Rev.4 1.5 1.5-1 Rev.4 Figure 1.1-1 N/A Rev.0 2.0 2.0-1 Rev.0 2.1 2.1-1 and 2.1-2 Rev.0 2.1 2.1-3 Rev.3 2.1 2.1-4 through 2.1-12 Rev.0 2.2 2.2-1 through 2.2-7 Rev.0 2.2 2.2-8 Rev.4 2.2 2.2-9 Rev.0 2.2 2,2-10 Rev.4 2.2 2.2-11 through 2.2-16 Rev.0 2.2 2.2-17 Rev.3 2.2 2.2-18 through 2.2-22 Rev.0 2.3 2.3-1 through 2.3-12 Rev.O j

2.4 2.4-1 Rev.3 2.4 2.4-2 and 2.4-3 Rev.0 2.4 2.4-4 Rev.3 2.4 2.4-5 through 2.4-31 Rev.0 2.4 2.4-32 Rev.4 2.4 2.4-33 through 2.4-36 Rev.0 2.5 2.5-1 through 2.5-12 Rev.0 2.5 2.5-13 Rev.4 l

2.5 2.5-14 through 2.5-47 Rev.O 2.6 2.6-1 through 2.6-10 Re.v.0 Tables 2.3-1 through 2.3-6 N/A Rev.0

. (

Figure 2.3-1 N/A Rev.O uv Revision 4

l 0

LIST OF EFFECTIVE PAGES DFFI!FT FD SAFFTY ANATYSTR RFPORT Sectinn Fffective P,oes Revisinn Figures 2.4-1 and 2.4-2 N/A Rev.0 3.0 3.0-1 Rev.0 3.1 3.1-1 through 3.1-6 Rev.0 3.1 3.1-7 Rev.4 i

3.1 3.1-8 through 3.1-28 Rev.0 3.2 3.2-1 Rev.0 3.2 3.2-2 Rev.4 3.2 3.2-3 through 3.2-5 Rev.0 l

3.2 3.2-6 through 3.2-41 Rev.4 3.3 3.3-1 Rev.4 j

3.3 3.3-2 through 3.3-3 Rev.0 3.3 3.3-4 Rev.4 3.3 3.3-5 through 3.3-7 Rev.0 3.3 3.3-8 Rev.4 3.3 3.3-9 through 3.3-11 Rev.3 3.3 3.3-12 Rev.4 3.3 3.3-13 Rev.0 3.3 3.3-14 Rev.3 3.3 3.3-15 and 3.3-16 Rev.4 i

3.3 3.3-17 through 3.3-19 Rev.0 3.4 3.4-1 Rev.0 3.4 3.4-2 through 3.4-4 Rev.4 3.4 3.4-5 through 3.4-6 Rev.0 l

3.5 3.5-1 Rev.0 3.6 3.6-1 through 3.6-3 Rev.0 Tables 3.1-1 and 3.1-2 N/A Rev.0 l

Table 3.1-3 N/A Rev 4 Tables 3.1-4 through 3.1-7 N/A Rev.O Tables 3.2-1 through 3.2-3 N/A Rev.O Tables 3.2-4 through 3.2-5 N/A Rev.1 Table 3.5-1 Sheet 1 Rev.3 Table 3.5-1 Sheet 2 Rev.4 Table 3.5-1 Sheets 3 through 8 Rev.3 Table 3.5-1 Sheets 9 through 15 Rev.4 Table 3.5-1 Sheets 16 through 38 Rev.3 l

Revision 4 uvi

O LIST OF EFFECTIVE PAGES DFFTIFT FD SAFFTY ANAT VSTS RFPORT Rectinn Fffective Pgoes Revi< inn Figures 3.1-1 through 3.1-19 N/A Rev.O.

Figures 3.2-1 through 3.2-14 N/A Rev.O Figures 3.2-15 through 3.2-22 N/A Rev.4 Figures 3.2-23 through 3.2-30 N/A Rev.O Figure 3.3-1 N/A Rev.3 Figure 3.3-2 N/A Rev.4 Figure 3.3-3 N/A Rev.4 4.0 4.0-1 Rev.4 4.0 4.0-2 Rev.3 4.1 4.1-1 and 4.1-2 Rev.0 4.14.1 4.1-3 through 4.1-5 Rev.3 4.2 4.2-1 through 4.2-3 Rev.-4 N

4.3 4.3-1 and 4.3-2 Rev.0 4.3 4.3-3 Rev.4 4.3 4.34 Rev.0 4.3 4.3-5 and 4.3-6 Rev.4 4.4 4.4-1 Rev.4 4.5 4.5-1 Rev.4 Table 4.1-1. Page 1 N/A Rev.4 Table 4.1-1, Page 2 N/A Rev.3 Tables 4.3-1 N/A Rev.3 Figure 4.2-1 N/A Rev.4 Figure 4.2-2 N/A Rev.4 5.0 5.0-1 Rev.0 5.1 5.1-1 Rev.0 5.2 5.2-1 through 5.2-7 Rev.0 5.3 5.3-1 through 5.3-8 Rev.0 5.4 5.4-1 through 5.4-4 Rev.0 5.5 5.5-1 Rev.0 5.5 5.5-2 through 5.5-9 Rev.3 5.6 5.6-1 Rev.1 5.6 5.6-2 Rev.3 5.6 5.6-3 Rev.0 N-uvii Revision 4

LIST OF EFFECTIVE PAGES O

DFFTIFT FD SAFFTY ANAI_YSTS RFPORT Sectinn Fffective Pnget Revicinn 5.6 5.6-4 through 5.6-10 Rev.3 5.7 5.7-1 Rev.0 5.8 5.8-1 Rev.0 5.9 5.9-1 through 5.9-2 Rev.0 Tables 5.5-1 N/A Rev.3 Figures 5.2-1 through 5.2-6 N/A Rev.O Figures 5.3-1 through 5.3-3 N/A Rev.O Figure 5.4-1 N/A Rev.0 6.0 6.0-1 through 6.0-8 Rev.0 6.1 6.1-1 through 6.1-4 Rev.0 6.2 6.2-1 through 6.2-3 Rev.0 6.3 6.3-1 through 6.3-4 Rev.0 6.3 6.3-5 Rev.4 6.3 6.3-6 Rev.0 6.3 6.3-7 Rev.4 6.4 6.4-1 Rev.3 6.4 6.4 2 Rev.4 Tables 6.0-1 through 6.0-5 N/A Rev.0 Tables 6.2-1 and 6.2-2 N/A Rev.0 Tables 6.3-1 and 6.3-2 N/A Rev.O Figures 6.3-1 through 6.3-6 N/A Rev.0 7.0 7.0-1 Rev.3 7.1 7.1-1 Rev.4 7.1 7.1-2 Rev.3 7.1 7.1-3 and 7.1-4 Rev.4 7.1 7.1-5 Rev.3 7.2 7.2-1 and 7.2-2 Rev.3 7.2 7.2-3 through 7.2-6 Rev.0 7.3 7.3-1 and 7.3-2 Rev.3 7.3 7.3-3 Rev.0 7.4 7.4-1 Rev.0 7.5 7.5-1 Rev.4 7.6 7.6-1 Rev.0 8.0 8.0-1 Rev.o 9.0 9.0-1 Rev.O j

Revision 4 uviii

p 12 GFNFR AI. PI ANT OFSCRIPTION The Trojan Nuclear Plant site consists of approximately 623 acres located in Columbia County

)

in NW Oregon on the Columbia River at River Mile 72.5 from the mouth. The distance from the reactor site to the nearest site boundary on land is 2172 ft. Major structures on the site include the Containment, Turbine Building, Auxiliary Building, Fuel Building, Control Building, and a single natural draft cooling tower.

1 The town of St. Helens, Oregon, the county seat of Columbia County, is located approximately 12 miles SSE of the site. The town of Rainier. Oregon, is located approximately 4 miles NNW and the town of Kalama, Washington, is approximately 3 miles SE of the site. There are three small unincorporated communities within a 5-mile radius of the site: Prescott, Oregon, located approximately 1/2 mile N of the site:

l

("N Goble. Oregon, located approximately 1-1/2 miles SSE of the site; and Carrolls, Washington,

\\")

i located approximately 2-1/2 miles NNE of the site.

111 DFSIGN CRITFRfA The principal design criteria for the Trojan Nuclear Plant are those fundamental architectural and engineering design objectives established for the Facility. The basis for development and selection of the design criteria used in this Facility were those which: (a) provide protection of public health and safety, (b) provide for reliable and economic Facility performance, and (c) provide an attractive appearance.

The essential systems and components of the Facility are designed to enable the facility to withstand, without loss of the capability to protect the public, the additional forces that might be imposed by natural phenomena. The designs are based on the most severe of the natural fq phenomena recorded for the vicinity of the site, with margin to account for uncertainties in V

historical data.

12-1

I22 FITFT M ANDT ING SYSTFNi l The Facility was designed to handle spent fuel under water from the time it leaves the reactor vessel until it is placed in casks for shipment from the site, although PGE is prohibited from moving fuel into the containment. Underwater transfer of spent fuel provides an optically transparent radiation shield, as well as a reliable source of coolant for removal of decay heat.

12.1 R ADIOACTIVE WA!iTF TRFATifENT SYSTFifS The radioactive waste treatment systems provide equipment necessary to collect, process, monitor, and discharge radioactive liquid, gaseous and solid wastes that are produced at the Facility.

Liquid wastes potentially containing radioactive material are collected and monitored. Prior to discharge, equipment is provided for filtering and demineralizing the liquid as required. The treated water from the filters or demineralizers may be recycled for use in the Facility or may be discharged to the Columbia River. The miscellanecus dry waste, spent demineralizer resins and spent filters are shipped from the site for ultimate disposal in an authorized location.

Gaseous wastes are collected and discharged to the environment after filtration to keep the offsite dose within prescribed limits.

Resision 4 1.2-2

f i

1.4 EXCLL*SIONS FROh! AND EXE5tPTIONS TO CERTAIN PARTS OF TITLE 10 OF THE CODE OF FFDFRAT RFatif ATIONS (10 CFR) 1 4.1 FYCIITSIONS FROM CFRTAIN PARTS OF 10 CFR 4

In a letter dated 5farch 15,1993 from J. E. Cross, Portland General Electric (PGE) notified the Nuclear Regulatory Commission that on receipt of the Possession Only License (POL), the following Parts of Title 10 of the Code of Federal Regulations (10 CFR) are no longer 4

applicable to the Trojan Nuclear Plant (TNP):

4 i

1411 10 CFR M Fitneu for Durv Prngrnm i

10 CFR 26 is applicable to licensees authorized to operate a nuclear power reactor. Since approval of the POL, PGE has not been authorized to operate the TNP as a nuclear power reactor. Although this regulation is not applicable to TNP with a POL, PGE has committed via letter dated January 27,1993 to the NRC to maintain the current Fitness for Duty Program 1

at TNP after receipt of POL.

4 1.4.1.2 10 CFR 50.44. Standards for Combustible Gas Control System 5

in I icht-Water Cnnled Pnwer Resetnrt

'f This regulation is applicable to fueled nuclear power reactors. The TNP reactor has been l

defueled permanently. Thus, this regulation is not applicable to TNP. This was codified by l

l the Final Decommissioning Rule which became effective August 28,1996.

l 4

O 4

1.4-1 Revision 4 i

i

i i

i

(

l l

1.4.1.3 10 CFR 50.46, Acceptance Criteria for Emergency Core Conting Systemt for i ight Wnter Nuctenr Pnwer Renctors 1

This regulation is applicable to fueled nuclear power reactors. The TNP reactor has been i

l l defueled permanently. Thus, this regulation is not applicable to TNP. This was codified by l the Final Decommissioning Rule which became effective August 28,1996.

L4.LJ 10 CFR 50 4R Fire Prntectinn This regulation applies to operating nuclear power plants. TNP has been defueled and is not authorized under the POL to operate as a nuclear power plant again. Thus, this regulation is l not applicable to TNP. The Final Decommissioning Rule, which became effective l August 28,1996, modified this rule to make it applicable to plants that are permanently shut l down, and altered the tule to recognize the limited threat of fire for shutdown plants. The l modified final rule is, therefore, now applicable to Trojan.

1.4.1.5 10 CFR 50, Appendix R. Fire Protection Program for Nucienr Pnwer Fncilities Onernring Prior en Januarv 1 1979 his regulation applies to operating nuclear power plants. TNP has been defueled and is not authorized under the POL to operate as a nuclear power plant again. Thus, this regulation is not applicable to TNP.

1.4.1.6 10 CFR 50.49, Environmental Qualification of Electrical Fnninment imnnrrsnt tn Rafety for Nnciene Pnwer P!nnte This regulation applies to operating nuclear power plants. TNP has been defueled and is not l

authorized under the POL to operate as a nuclear power plant again. Thus, this regulation is l not applicable to TNP. This was codified by the Final Decommissioning Rule which became l effective August 28,1996.

Revision 4 i.4 2

.~.

t i

)

1 1 4 1_7 10 CFR (0 54 In Rervice Insnectinn Requirements 10 CTR 50.55a Paragraphs (f) and (g) specify requirements for in-service testing of pumps and valves and in-service inspection of components (including supports), respectively. 10 CFR 50.55a Paragraphs (f)(4) and (g)(4) indicate that Paragraphs (f) and (g) of the rule are I

applicable throughout the service life of the plant. Since TNP is no longer in service, the regulation is not applicable.

1.4.1.3 10 CFR 50.60 Acceptance Criteria for Fracture Prevention

\\fentures for i ight-W,rer Nuclear Pnwer Rencenrt 10 CFR 50.60 requires licensees to meet the requirements of 10 CFR Appendices G and H.

Appendices G and H are not applicable to TNP since receipt of POL. This was codified by l

the Final Decommissioning Rule which became effective August 28,1996.

l O

1.4.1.9 10 CFR 50.61. Fracture Toughness Requirements for Prntectinn Agniner Preuuri7ed Thermal Rhnck Fvente This regulation applies to operating nuclear power plants. TNP has been defueled and will not be authorized under the POL to operate as a nuclear power plant again. Thus, this regulation is not applicable to TUP. This was codified by the Final Decommissioning Rule which l

became effective August 28,1996.

l 1_.i 1 10 10 CFR 50 Annendir G_ Frncture Tnughnect Renuirement_t 10 CFR Appendix G specifies fracture toughness requirements of reactor coolant pressure boundary to provide adequate margin of safety during any condition of normal operation over its service lifetime. The TNP Reactor Coolant System is no longer operating and has completed its service life. Thus, this regulation is no longer applicable to TNP.

1.4-3 Revision 4

1.4.1.11 10 CFR 50, Appendix H. Reactor Vessel Material Surveillnnce Progrnm Renuiremente 10 CFR Appendix H provides the requirements of a reactor vessel material surveillance program. The data obtained from this program are utilized as required by Sections IV and V of Appendix G. Appendix G is no longer applicable to TNP and thus Appendix H is also no longer applicable.

1.4.1.12 10 CFR 50.62, Requirements for Reduction of Risk From Anticipated Transients Without Scram (ATWS)

Evenre for I.ight-Water Confed Nucient Pnwer Plants The ATWS mitigation system for a pressurized water reactor is intended to actuate auxiliary feedwater and initiate a turbine trip under conditions indicative of an ATWS. The issuance of the POL precludes power operation at Trojan, and thus this regulation is not applicable to l TNP. This was codified by the Final Decommissioning Rule which became effective l August 28,1996.

141.11 10 CFR 50 61 inte nf All Alternating-Current Pnwer This regulation applies to operating nuclear power plants, ensunng that the reactor core is cooled and containment integrity is maintained in the event of a loss of all alternating-current power. The reactor core at TNP has been offloaded to the spent fuel pool and PGE is not authorized under the POL to operate Trojan as a nuclear power plant again. Thus, this regulation is not applicable to TNP.

.4 Revision 4 1.4-4

1_4.1.14 to CFR 50 71(e)_ Maintenance of Reenrd \\fnking of Rennrtc 4

This regulation applies to operating nuclear power plants. TNP has been defueled and is not authorized under the POL to operate as a nuclear power plant again. Thus, this regulation is not applicable to TNP. The Final Decommissioning Rule, which became effective l

August 23,1996, modified this mle to make it applicable to plants that are permanently shut l

down, and altered the rule to recognize the limited safety importance of Safety Analysis l

Updates for shutdown plants. The modified final rule is, therefore, now applicable to Trojan.

]

i 1.4_ i li 10 CFR 70 24. CAricnlity Accident Rec.uirements By letter dated Febmary 16, 1993 from S. H. Weiss (NRC) to J. E. Cross (PGE), the staff has notified Trojan that with the absence of new fuel, the design of the storage racks, and the procedural controls over fuel handling activities with Certified Fuel Handler training, adequate O

j g

assurance against the occurrence of an accidental criticality exists that this regulation no longer applies to Trojan in its permanently shutdown and defueled condition.

l 1.4.2 EXEMPTIONS TO 10 CFR RELATED TO TMF PFRMANFNTT Y DFFTIFT FD CONDTTTON i

There are also certain 10 CFR regulations to which the NRC has granted specific exemptions to PGE for the opr. tion of the Trojan Facility.

1.4.2.1 10 CFD 50.54(o) and Appendix J Pnmary Reactor Containment i en!

Testino (nr W2rer Cnnled Power Resetnrt 4

By letter dated April 12,1993 from M. T. Masnik (NRC) to J. E. Cross (PGE) the NRC will permit PGE to cease all testing required by 10 CFR 50.54(o) and 10 CFR 50, Appendix J.

1.4-5 Revision 4

l l

1422 to CFR <0 54(vt cnnaitinns nr i icrners l

~

By letter dated June 23,1993 from M. T. Masnik (NRC) to J. E. Cross (PGE) the NRC will permit PGE to depart from a license condition or technical specificatica in an emergency as describ-1 in 10 CFR 50.54(y) provided that the emergency action is approved, as a minimum, by a Certified Fuel Handler prior to taking the action.

l 1.4.2.3 10 CFR 50.54(o) and Certain Sections of 10 CFR 50.47. 'Fmergency Phns " and l

10 CFR 50. Annendix E. " Content of Emergency Phns" l By letter dated September 30,1993, from M. T. Masnik (NRC) to J. E. Cross (PGE), the l NRC authorized the Trojan facility to discontinue offsite emergency preparedness activities and l reduce the scope of onsite plannmg.

1 l

Revision 4 1.4-6 i

-.. -l j

1 1 < NiiTFRf Af _ INFORROR -\\TFD BY RFFFRFNCE l

Certain program manuals and topical reports have been incorporated into the DSAR by il reference and are lis:ed in the last section of each chapter. The repons include topical reports written by PGE as well as by Westinghouse, Bechtel and other organizations.

Some documents that are incorporated by reference continue to be updated to assure that the -

inforTnation presented is the latest available. These documents include those listed below:

(1)

PGE 1060, " Permanently Defueled Emergency Plan.'

(2)

PGE-1012, " Fire Protection Plan."

f (3)

PGE 1017 " Security Plan."

l (4)

PGE-1020, " Report on Design Modifications for the Trojan Control Building."

(5)

PGE-1037,." Trojan Nuclear Plant Spent Fuel Storage Rack Replacement Report."

l (6)

PGE-8010. " Nuclear Quality Assurance Program."

l (7)

PGE-1052, " Quality-Related List Classification Criteria for the Trojan Nuclear Plant."

(S)

PGE-1021, "Offsite Dose Calculation Manual."

l (9)

PGE-1057, " Trojan Nuclear Plant Certified Fuel Handler Training Program."

l (10)

PGE-1024, " Trojan Nuclear Plant Security Force Training l

and Qualification Plan (Defueled Condition)."

(11)

PGE-1061, " Decommissioning Plan."

1 (12)

PGE-1%3, " Supplement to Applicant's Environmental Report - Post Operating l

License Stage."

l l

l 2

a

O 1.51 Resision 4

)

i

e h

M Reld are a DeHavilland 3 corporate plane, a Siddely Hawker, a Cessna Citation, and a Falcon Jet ". The Portland International Airport is located 33 statute miles south of the site, anri is the only major airpon within a 60-mile radius of the site. Ponland inbound and outbound air traffic is controlled for a distance of 30 miles from the airpon by Portland Air Traffic Control.

Area-wide inflight traffic control is regulated by Seattle Air Traffic ControlM.

i 213 FVAT IIATTON OF POTFNTIAT. ACCIT3FNTS 4

This section provides an evaluation of the capability of the Trojan Nuclear Plant to safely 1

withstand the effects of an accident at, or as a result of the presence of, industrial, transportation and military installations or operations within 5 miles of the site. Potential accidents considered include impacts to and blockage of the cooling water intake stmeture;

)

i explosions of chemicals, flammable (including natural) gases or munitions; industrial and o

forest fires; accidental releases of toxic gases; accidental releases of corrosive liquids or oil i

into the Columbia River upstream of the cooling water intake structure; and collapse of the 4

cooling tower.

12 11 Fvninsinnt

.i Shipments of commercial cargo past the Plant create the possibility of nearby explosions.

Safety-related ponions of the Plant are protected from such explosions.

i Explosions unrelated to transportation are not considered significant. The quarry operations south of the site are located in the hills west of the Columbia River. Presently, there is no storage of explosives at the operating quarry which is 2 miles from the site. The quarry is not a large operation and only a limited amount of explosives are used. Because of the j

distance from the Plant and the protection afforded by the hillside and ridge between the i

g quarry and the Plant, the quarry operation does not present a hazard to the safety of the Plant.

)

'L]

A natural gas main extending to Wauna, Oregon, 2.2-7

downriver of the site mns along the hillside west of the site, approximately 1-1/2 miles from the site. The main is a 16 inch. 3-million foot / hour line, buried a minimum of 3 feet 00) In addition, there is an odorizer station on the line at Goble, 2 miles south of the site, a river i

crossing at Deer Island,4-1/2-miles south of the site and a river crossing at Rainier, 5-miles north of the site. The operation of these lines will not present a hazard to Trojan from explosion because of the relatively low explosive capacity of the gas and the d: stance from the 1

l Plant proper.

l Even though there is some evidence that transportation accident rates involving hazardous cargo are below the overall average because of precautionary measures taken with such os) shipments

, no credit is taken for this factor.

On the other hand, it may be assumed that the rate of accidents caused by the nature of the hazardous material itself (explosion of cargo not caused by traffic accident) is comparatively low and may be neglected. However, it is realized that the transportation accidents down to a low degree of severity must be considered here as the explosion may be triggered by a minor cause (shock, spark, heat).

The effect of a transportation accident involving explosive cargo is based on the assumptior.

that an explosion does occur.

i The major distance effects of a surface explosion are:

(1) Atmospheric effects (shock wave and momentum effects).

(2) Ground effects (direct and air-induced ground shock).

Revision 4 2.2-8

.O

\\

(3) Cier effects (missiles, waves, noxious fumes or incendiary effects).

Studies of these effects have led to the conclusion that the atmospheric shock wave is the

]

severest effect (most limiting) with regard to safety-related stmetures cf power plantsM The value of the limiting (maximum permissible) overpressure generated by the atmospheric shock from the explosion is 2.2 psi (p, = 2.2 psi). This limit is chosen in recognition of the 1

fact that the actual overpressure experienced by parts of the stmeture may be up to twice this d 8) value (4.4 psi) due to reflected wave effects It is noted that test stmetures generally similar to those employed for safety-related stmetures at Trojan have demonstrated that overpressures of 5 psi can be endured without any significant damage to these structures". Thus, it appears that the 2.2 psi overpressure used in this analysis incorporates substantial conservatism. Furthermore, it is noted that safety-related d

structures are designed to withstand pressure differentials of at least 3 psi due to tornado effects.

A missile caused by an explosion at a distance greater than that at which 2.2 psi would occur would not be as severe as the assumed tornado missiles. If the range were less than that corresponding to 2.2 psi, the blast damage would be more critical than the missile damage.

Missiles from the cooling tower failure are considered comparable to the tornado missiles. If the probabilities of the explosion occurring within the range corresponding to 2.2 psi are shown to be remote, the effects of the explosion can be neglected.

The method of analysis employed subsequendy is common to all types of transportation. This is due to the fact that the means of transportation considered here (train, barge) are confined to a rather narrow track (rail, channel) which leads past the Plant nearly as a straight line. Trains and barges are assumed to be moving along these lines at normal 2.2-9

l l

91 speed and are therefore subject to accident rates per mile of track (taken to be constant along the track). The pertinent accident rates are discussed below.

i An approximate relation for th: peak (positive) overpressure of the shock wave from an j

explosion can be written as:

p = a x g*

(2.2-1) where p = peak overpressure (psi) g = scaled distance from center of explosion (ft/lb"3) a, b = constants.

O A good approximation in the range of pressure 0.1 < p < 10 psi is obtained by setting:

a = 200 The scaled distance is defined as:

g = _P__ (ft/lbv3) (2.2-2) l W u3 where P = distance from center of explosion (ft)

W = weight of explosive, TNT equivalent (Ib).

Revision 4 2.2-10

i l

D 14 A PRORARI F \\f AYINilNi TSIINAXff FT OOnfNG l

Historically the evidence demonstrates that the mouth of the Columbia River is relatively 1

l insensitive to tsunamis when compared to Crescent City, California, 310 miles south of the Columbia River entrance.

I The tsunami effects at the mouth of the Columbia River are further dissipated inside the river due to the characteristics of the estuary, as was demonstrated during the tsunami generated by the Alaskan earthquake of March 28,1964.

The elevation of the Plant site is 45 feet MSL. Because of the large margin between the Plant elevation and the river surface and because of the insensitivity of the river to tsunami effects, tsunamis are not considered in the design criteria for the Trojan Plant.

O 14 7 iCF FFFFCTS The general climate in the lower Columbia River Basin is not conducive to ice formation. In i

addition, the flow of the river during periods of freezing temperatures is sufficiently large (200,000 to 400.000 cfs) that ice formation is impossible in the main streamflow. During extended periods of freezing temperatures, some icing is experienced along the banks of sloughs and inlets where the water is slow moving or stagnant.

Any surface ice formation in the vicinity of the intake structure would not affect tlm operation of the intake stmeture, as the water entrance is below the water surface.

l The lowest recorded river temperature at the site was 34.1*F on Febmary 6,1971 (period of l

1 l

record 1967 to 1972)A.

1 l

2.4-31

Lt R COOI ING WATFR CANAT R AND RFSFRVOIRS The cooling water for the Trojan Plant is drawn in through an intake stmeture located on the bank of the Columbia River and oriented perpendicular to the riow of the river.

The intake channel provides a water channel to the intake stmeture during low flows. During a flood, the intake channel would be kept clear by the scouring action of the water flow.

2 4 9 CT-TANNFI DIVFRSIONS The Columbia River, for most of its lower reach, flows through a relatively narrow gorge.

Diversion or rerouting of the river is impossible because of tnis gorge and the mountain ranges through which the river flows. Blockage of flow due to a catastrophic landslide or some other incredible event upstream of the Plant would not present a hazard. Should flow in the river reach zero (which would require blockage of all tributaries also), the river channel would act as a extension of the Columbia River estuary. The service water pump inlets are located at -8 feet MSL.

14.10 FT _OODING PROTFCTION RFOITTRFMFNTS All facilities / equipment required for the storage of irradiated fuel are located above or are protected for water levels to Elevation 45 feet MSL. The intake stmeture is the only stmeture exposed to the river flow below Elevation 45 feet MSL. In the unlikely event of an intake l structure failure resulting in the loss of service water supply for SFP cooling, at least 10 days are available to establish makeup flow to the SFP to maintain required cooling.

Revision 4 2.4-32

._~ -.

I l

i

!O i

Trojan site. This maximum potential earthquake that could affect the site is called the Seismic l

Margin Earthquake (SME).

These studies determined a value for the SME peak horizontal ground acceleration to be f

0.38 gM. The SME impact on facility design is discussed in Section 3.2.2.6.

l 15.3 St*RFACF F ATIT TING l

Fegional and site geology are presented in Section 2.5.1.

)

i 2.5 3.1 Gentnoic Conditinn nf the Site i

The site is m the Willapa Hills geomorphic province, a part of the Coast Range. Most of the fm region is below 2000 feet in elevation. The descent from the hills to the Columbia River is j

V rather precipitous, but elsewhere the hills merge gradually into the surrounding lowlands.

i The bedrock in the area is comprised of a series of moderately folded tertiary formations of i

1 both sedimentary and volcanic origin. The folding in the area conforms generally to the northwest Coast Range structural trend. The Eocene formations north of the Columbia River are folded as part of a syncline. Pliocene sediments in the vicinity of the site are only slightly i

I warped and the Pleistocene arxi Recent deposits appear to be flat lying and undisturbed. A detailed discussion of the regional geology is presented in Section 2.5.1.

1

~

Faulting is minor in the structural development of the area, and is generally of small l

displacement. Many of the mapped faults in the area are based on topographic lineations in l

the pre-Pleistocene strata. No evidence of post-Pleistocene surface displacement has been j

}

found in the area.

O i

2.5-13 Resision 4 1

1 i

J O'

An extensive investigation was made as pan of the geologic evaluation of the Trojan site to i

1 locate all faults which might be significant to the site. A special effort was made to detect any lineations or indications of offset in the alluvium, terrace deposits, or the Pleistocene alluvial deposits. As a result of the study, the following conclusions were reached:

i (1) The "Kelso Fault", as indicated in Bulletin 54 of the Washington Division of o2), does not exist.

Mines and Geology (2) The available geologic evidence indicates that there is not a fault in the old stream channel west of and adjacent to the site.

4 l

\\

l (3) The field evidence indicates that the Clatskanic fault does not extend farther east than indicated on the Oregon State Geologic Map.

9 i

(4) The available geologic evidence does not indicate that a fault exists along the l

l Columbia River adjacent to the Trojan site.

l (5) The fault zone exposed in the road cut southeast of Kelso and 4.7 miles from the i

site is apparently not extensive and probably has not experienced movement since deposition of the Troutdale formation during lower pliocene time. This fault zone is not significant to the Trojan site.

(6) Thew is no fault within 5 miles of the Trojan site which has experienced movement since Pleistocene time.

l 1512 investigntinn for rnnable Faiilte An extensive literature study was made as pan of the geologic evaluation of the Trojan site to locate all faults that might be significant to the site. The bibliography for this 2.5-14

4 4

and reponing of radioactive effluents meet the requirements of Regulatory Guides 1.21 and i

4.1.

I Criterion 64 is met by Trojan design.

l 3.12 Cf ASSTFICATION OF STRiiCTTTRFR COMPONENTS AND SYSTFMS l

The classification of structures, components and systems for the facility will be per the quality

{

related definition as described in Topical Report PGE-8010. " Nuclear Quality Assurance Program". Implementation of the classification is described in PGE Report PGE-1052, j

" Quality-Related List Classification Criteria for the Trojan Nuclear Plant"*.

i r

For the permanently defueled condition, the Control, Auxiliary and Fuel Building Complex; SFP, including the spent fuel racks; and the fuel transfer tube are the only structures, systems, l

or components that are classified as Seismic Category I (safety-related). The Containment Structure and the Fuel Building Steel Superstructure are classified as Seismic Category II/I.

31 1 WIND AND TORNADO I OADINGS i

'ne Trojan Facility is capable of withstanding the effects of severe winds or tornadoes without loss of capability of the safety systems to perform their safety functions. The following sections provide the basis for the design wind and tornado parameters and methods used in meeting the wind and tornado criteria for the Facility, i

l 3.1-7 Revision 4

h 1111 wird i maings 3.1.3.1.1 Design Wind Velocity The design wind velocity for all Category I and Category II structures is 105 mph at 30 ft above the nominal ground elevation of 45 feet MSL. Section 2.3 provides meteorological data for the site.

3.1.3.1.2 Determination of App!!ed Forces Shape factors, variation of wind velocity with height, gust factors and methods of converting wind J

velocities into loads to be resisted by the structures are based on ASCE Paper No. 3269, " Wind Forces on Stmetures",1961. Table 3.1-1 indicates the design loads. These loads are considered in the design of all Category I and Category II structures. However, since wind and earthquakes are not assumed to act simultaneously, for stmetures where seismic forces exceed the wind loads, no further analysis is performed. For stmetures where wind load governs, the load is combined with other appropriate loads as required by the various load equations.

Wind loads are applied to the stmetures as uniform static loads on the vertical and horizontal projected areas of the structure walls and roof. Roof loads due to wind are treated the same as roof dead and live loads with the direction of loading taken into account. Only dead load is considered as resisting uplift. Horizontal wind loads are distributed by the walls to the floor and roof diaphragms which, in turn, transfer the loads to the lateral load carrying elements of the stmetures.

1 1 1 ? Tnrn2an i maing.

In the continental United States, west of the Rocky Mountains, the occurrence of tornadoes is unlikely. However, to ensure that any damage which may be sustained by 3.1-3

1 OIg 3.2 SPRNT FIIFT RTOR AGE This section describes the design features of the Control, Auxiliary, and Fuel Building 3

Complex and the SFP which are utilized for the long-term safe storage of spent fuel at the site.

l

'4 11 CONTROI. AIIXfii ARY. AND FT*FT RT*TT DING CONfPT FY The Fuel Building, which contains the SFP, is part of the Control, Auxiliary, and Fuel Buildings Complex. This section describes the design bases, criteria and analytical techniques for the design of the Complex.

Figures 3.2-1 through 3.2-9 indicate typical constmetion details of the Seismic Category I structures and the Fuel Building steel superstructure, which is Seismic Category II/I. Figures 3.2 23 through 3.2-30 indicate typical construction details for the Containment Structure which is also Seismic Category II/I.

3.11.1 Dewrintion The Complex is interconnected by their foundation systems and floor and roof slabs.

Therefore, in the seismic analysis all three buildings were considered as a unit. The seismic analysis of the Complex is covered in Section 3.1.6.

The Complex is composed of a stmetural steel framing system with steel beams and columns supporting reinforced concrete floor slabs, with shear walls designed to resist lateral seismic -

forces of an earthquake. Most of the shear walls are of a composite-type construction consisting of a reinforced or unreinforced concrete core between two layers (wythes) of reinforced grouted masonry block. The two block wythes generally sandwich the structural steel frame so that the steel frame members are embedded in the concrete core.

3.2-1

h 3.2.1.1.1 Fuel Building The Fuel Building at and below Elevation 93 feet 0 inches is a Seismic Category I structure. It contains facilities for the handling and storage of spent fuel and systems used for the processing of liquid, solid, and gaseous radioactive wastes generated by the Plant. It consists of four floors above grade (Elevation 45 feet), the SFP, cask loading pit, new fuel storage pit, cask wash pit and three reinforced concrete vaults enclosing the three Chemical Volume Control System (CVCS) holdup tanks.

The Fuel Building steel superstructure above Elevation 93 feet is classified as the Seismic Category II/I structure. The Fuel Building steel superstructure houses a 125 ton overhead crane capable of handling heavy loads, such as a spent fuel assembly shipping cask, and a fuel-handling crane which runs on rails mounted on the operating floor. The travel of the overhead crane is restricted over the SFP by means of mechanical stops and administrative l controls. These stops and limit switches may only be bypassed or removed while following an j approved procedure, and then only with the Shift Manager's approval.

Mechanical anti-derailing devices mounted on the wheel axles of the overhead crane bridge and trolley prevent the crane from being dislodged from its rails due to horizontal motion during an earthquake. The vertical acceleration due to an earthquake is not large enough to overcome the crane's downward load due to gravity.

At the west side, the Fuel Building is structurally connected to the Auxiliary Building.

. Expansion joint bellows at the fuel transfer tube provide for the relative movement between containment, containment intemals, and the SFP. The bellows consider all loading conditions including the SSE and maximum hydraulic pressure. The design of the expansion bellows considers the maximum computed relative axial and lateral displacement of the fuel transfer tube occurring simultaneously. Access for inspection and maintenance of the bellows is provided.

Revision 4 3.2-2

l l!OO 3.2.1.1.3 Control Building l

l The Control Building is & Seismic Category I structure and consists of four floors above grade (Elevation 45 feet). The Auxiliary Building is located to the east of the Control Building and the two buildings are structurally connected. The Turbine Building, located to the west, is separated from the Control Building by a gap which is adequate to prevent interaction between l

the two stmetures during an earthquake.

The framing members for the Control Building are stmetural steel. Floor slabs are reinforced concrete and precast prestressed concrete panels. Concrete block masonry and reinforced concrete are used for walls.

i 3.2.1.1.4 Modific:, tion to the Complex (D

The Cent,ei euiid,nt.as medif1ed eu,,n,1,so and 1,g1 te,nc, ease,he seismi ca,abili,, ef the overall Complex. The modification program was developed with two basic objectives:

first, to add strength to the building; second, to strengthen the connections among certain wall l

panels to achieve a better group action and improve overall seismic performance.

Strengthening of the Control Building was done by the addition of four new structural three parallel walls running in the north-south direction and a steel plate added to elements:

one wall. Two of the new walls closed the previous railroad bay openings in the east and west walls on column lines N and R, and the third wall is an interior shear wall crossing the l

previous railroad bay on column line N'. The upper portion of the west wall of the Control Building along column line R was further stiffened and strengthened by the addition of a 3-inch-thick steel plate. The previous railroad bay in the Control Building was thus totally enclosed, and the railroad spur that used to mn threugh the Control Building was terminated in the Turbine Building.

3.2-5

In addition to the four new structural elements, stmetural improvements were also made at several locations to strengthen connections. Four structural improvements involved strengthening the existing bolted beam-column connections of column 46-N beneath Elevation 61 feet, Elevation 77 feet and Elevation 93 feet, and column 46-R beneath Elevation 77 feet by welding additional plates. The remaining structural improvements consisted of connecting the horizontal reinforcing steel at the following walls to make the steel continuous:

(1) The 41 wall at column 41-Q, Elevation 45 feet to Elevation 65 feet (2) The 46 wall at column 46-N', Elevation 45 feet to Elevation 61 feet (3) The 55 wall at column 55-Q, Elevation 45 feet to Elevation 61 feet (4) The 55 wall at column 55-N', Elevation 45 feet to Elevation 61 feet.

I Figures 3.2-10 through 3.2-14 show the stmetural modifications to the Control Building.

3117 nesign Rwe The design bases for the Complex are defined within the following classifications:

(1) Support - in addition to their own weight, the structures are designed to support the reactions and weight of the components of systems shown in Figures 3.2-15 l

through 3.2-22. Figures 3.2-15 through 3.2-22 reflect the structures and l

components of systems that existed during Trojan Plant operation, and are l

included in the DSAR for general information. 'Ihe components of systems and l

the stmetures shown on the figures are being de-activated, decommissioned, or l

removed in conformance with the Trojan Nuclear Plant Decommissioning Plan, Revision 4 3.2-6

I l

)

i i

O PGE-1061, which was approved by the NRC, by letter dated April 15, 1996.

l These figures are, therefore, historical in nature and are not required to be updated l

as the decommissioning activities are completed. Control of formal engineering l

drawings is maintained in accordance with PGE-1061.

l l

(2) Biological shield - the shielding design features are based on potential radiation sources during normal Plant operation, shutdown, and emergency operations (D.

The shielding design conservatively bounds the current defueled state.

l l

(3) Missile shield - the missile shielding design bases are given in 'iection 3.1.5.

l 1

i j

(4) Administrative control of access - the design bases are given in Section 7.7.

(5) Atmosphere control - the design bases include structural leak-tightness, external I

and internal pressures from usage of ventilation systems, and equipment shelter from the elements").

1 (6) Liquid control - protection from the efflux of water is required for the SFP and in areas where liquid radioactive wastes are handled by radioactive waste treatment U

systems ).

l (7) Seismic protection - design bases are given in Section 3.1.6.

(8) Wind protection - design bases are given in Section 3.1.3.

! O l

3.2-7 Revision 4

l 3111 Annlienhie Cndet Standardt and S,recificntinnt 3.2.1.3.1 Applicable to Original Procedure This section lists the codes, speci6 cations, regulatory guides, and other documents used in the structural design of the structures listed in this section except for the modifications of the Complex and the Fuel Building steel superstructure. Section 3.2.1.3.2 lists the codes, specifications, regulatory guides, and other documents used in the design of the modi 6 cations to the Complex. Section 3.2.1.3.3 lists the codes, speci6 cations, and other documents used in the assessment of the Fuel Building superstructure.

(1) Amerienn Cnnerete Institure (ACI):

ACI 315-65

" Manual of Standard Practice for Detailing Reinforced Concrete Standards".

ACI 318-63

" Building Code Reauirements for Reinforced Concrete".

(2) Amerienn inctimte nf Steel Cnnerructinn (AISC), "Speci5 cation for the Design, Fabrication, and Erection of Structural Steel for Buildings", Sixth Edition,1963.

(3) Amerienn Socierv nf Mechanient Fngineers, "ASME Boiler and Pressure Vessel Code", Sections III, V, VIII, and IX,1968 Editions.

(4) finifnrm nuitaing Cnae <tmC),1967 Edition.

(5) AFC Publientinn TfD 7024, " Nuclear Reactors and Earthquakes".

(6) Amerienn Socierv of Civil Fngineers (ASCF), " Paper No. 3269, Wind Forces on Structures".

Revision 4 3.2-8

l (7) A~eecan fren and Steel incrimre (ATSI), " Specifications for the Design of 1e Light Gauge Cold-Former Steel Structural Siembers',1961 Edition.

i (3) Amerirnn \\Wrer Wcrh Auncintinn (AWWA), AW',VA 31 11, i

l l

(9) Amerienn Railway Fngineering Actneintinn (ARFA), 'hianual of Recommended l

Practice".

l (10) Ti s Army enrne nf Fngineerc, Regulations with respect to dredging and l

constmetion of offshore structures for the Columbia River.

(11) State of Oregon, Bureau of Labor, Elevator Safety Act, Chapter 330.

L 1

l l

3.2.1.3.2 Applicable to Procedure Used for the Complex The following codes, standards and specifications were utilized in design, procurement and implementation of the Control Building modifications.

1 321111 rndec and crandarde, l

(1) Rnilaing ende nenniremenrc fnr neinforcea ennerere. ACI 318-77, American i

Concrete Institute.

t (2) Rnecifientinne for the Decian Fahrientinn ind Frectinn nf Rrmenirm) 5: teel fnr Bu1Mings, American Institute of Steel Constmetion (AISC) November 1,1978.

(3) rnde nf Standard Prnetice fnr 9 teel Ruildingc and Rridget, AISC i

(September 1,1976).

3.2-9 Revision 4

i (4) Ernndard Code for Arc nnd Gac Weldicg in Ruilding Cnnern crinn, AWS D1.179, Arnericaa Welding Society (AWS).

^4 2 1 1 2 2 NRC Reguintnry Guidec, i

(1) Regulatory Guide 1.10, Niechnnient (endweldi Snlices in Reinfnrcing Rnts of entrgnrv i ennerete Srnirnires, Rev.1, January 2,1973. This regulatory guide was withdrawn by the NRC in July 1981. Withdrawal does not alter prior licensing commitments based on its use.

(2) Regulatory Guide 1.15. Testing nf Reinforcing n,ra fnr enregnev I cnnerere stnicnires, Rev.1, December 28,1972. This regulatory guide was withdrawn by the NRC in July 1981. Withdrawal does not alter prior licensing commitments based on its use.

(3) Regulatory Guide 1.28, Qualirv Acturnnce Progrnm Requirements (Designs and Constmetinn), June 7,1972.

l (4) Regulatory Guide 1.33, Quality Accurnnce Prngrnm Renuiremente (Oneratinn), Rev. 2, February 1978.

1 (5) Regulatory Guide 1.38, Qualirv Accurance Rennirementc for Packagina Shinnina ;

Receiving Srnrnge 2nd Hnndling of freme fnr Water.Cnnled Nucienc Pnwer Pinnec, March 16,1973.

(6) Regulatory Guide 1.39, Mnntekeening Renuirements fnr Wnter ennled Nuclene pnwer Plantt, March 16,1973.

I Revision 4 3.2-10

1 l

i (7) Regulatory Guide 1.55, Cnnerete Placement in C,regnry I Krnieniren, June 1973. This I

regulatory guide was withdrawn by the NRC in July 1981. Withdrawal does not alter prior licensing commitments based on its use.

2 d

i (8) Regulatory Guide 1.58, Qualifientinn of Nuclear Pnwer Plant intnectinn Framinnrinn-5

,nd Teeting Perennnel. August 1973.

(9) Regulatory Guide 1.64, Qualirv Accirnnce Renuirementc fnr the 13ecign of Nuclesr 4

j ;

Power Pisnrc, Rev. 2, June 1976.

(10) Regulatory Guide 1.88, Cnllectinn Ernrnge ind \\fnintenance nf Nuctenr Pnwer Plant ounlirv Accirance Recnrds, Rev. 2. October 1976.

(11) Regulatory Guide 1.94, Qualirv Amir,nce penuiremente fnr incr2112rinn incnectinn and Tecting of Ermemr21 Concrete 2nd Ernictural Rreel During the Cnnctnierinn v

Phace of Nuclear Pnwer Plante, Rev.1, April 1976.

(12) Regulatory Guide 1.123, Qualirv Aunrnnce Renniremente for Cnntrni nf Prnenrement nf Treme 2nd Rervicec for Nuclamr Pnwer Plante October 1976.

1 il 121 Rnecincarinnc. Specifications for the Control Building modifications were prepared to cover the following areas:

(1) Furnishing and delivery of concrete.

(2) Forming, placing, and curing of concrete.

(3) Furnishing and delivery of reinforcing steel.

O 3.2-11 Revision 4

1 (4) Placing of reinforcing steel.

(5) Furnishing and delivery of miscellaneous steel items.

(6) Erecting miscellaneous steel items.

(7) Material testing services.

(8) Furnishing and installing of Cadwelds.

3.2.1.3.3 Applicable to Procedures Used for the Fuel Building Steel Superstructure The following codes, standards, specifications, and other documents were used in assessment of the Fuel Building steel superstructure.

371111 Cndet nnd Standards.

(1) S,necifientinn rne strucment steel Rniiding - A11nwnble strece nesign,nd PInstic Design. American Institute of Steel Constmetion (AISC), June 1,1989.

(2) Cnde of Renndard Prnetice for Steel Ruildingt and Bridges, AISC, September 1, 1986.

(3) Sentement Welding Cnde Steel AWS D1 1-90, American Welding Society.

(4) Steel Fmbedmente Annendir in Cnde Renuirement fnr Nuctenr Knferv-Related Cnnerere Rememres ACI 149 RO Annendir R, American Concrete Institute (ACD.

Revision 4 3.2-12

t

{O (5) nnilding cnde Requirements rnr Reinforced Concrete. ACI 313-86, American l

t i

Concrete Institute.

1 d

1 l

-3 214 i n2dc and in2d enmhinatinne

}

1 i

i This section gives the load combinations that are used in the analysis and design of the I

e structures listed in this section, including modification of the Complex. Basically, all l

strucmres are investigated for all the load combinations to determine the critical loads.

j Therefore, a list of load combinations used, as they apply to a particular structure, is not l

given.

3.2.1.4.1 Notations I

t The following notations are used in the load combination equations:

i U = required ultimate load capacity i

}

D = dead load of structure and equipment plus any other permanent loads contributmg

-)

stresses, such as soil or hydrostatic loads. An allowance is also made for future i

permanent loads i

i i

l L = live load i

i R = force or pressure on structure due to rupture of any one pipe i

T,= thermal loads due to temperature gradient through wall during operating conditions 1

4

)

Ho = force on structure due to thermal expansion of pipes during operating conditions l

3.2-13 Revision 4 1

i i

T3= thermal loads due to temperature gradient through wall during accident conditions H3= force on stmeture due to thermal expansion of pipes during accident conditions E = OBE resulting from ground surface acceleration of 0.15 E' = SSE resulting from ground surface acceleration of 0.25 A = hydrostatic load due to upstream dam failure W = wind load (Wind velocity 105 miles per hour at 30 feet above ground) 0 = capacity reduction factor (Detined in ACI 318-71 Code, Section 9.2.1) f, = allowable stress for structural steel F = yield strength for structural steel.

y 3.2.1.4.2 Seismic Category I Structure During Normal Operation For loads encountered during normal riant operation, Seismic Category I structures are designed in accordance with design methods of referenced codes and standards. Seismic design is in accordance with Section 3.1.6.

Revision 4 3.2 14

3 2 1.1 2 1 cnne rere. Reinforced concrete structures are designed for ductile behavior, i.e.,

with steel stresses controlling.

Design of concrete structures satisfies the most severe loading combinations, based on the load factors shown below:

U = 1.5 D + 1.8 L l

\\

U = 1.25 (D + L + H, + E) + 1.0 To U = 1.25 (D + L + H, + W) + 1.0 To U = 0.9 D + 1.25 (H + E) + 1.0 T o

o U = 0.9 D + 1.25 (H + W) + 1.0 T o

o l

In addition, for ductile moment-resisting concrete space frames and for shear walls:

i U = 1.4 (D + L + E) + 1.0 T + 1.25 H, o

U = 0.9 D + 1.25 E + 1.0 T + 1.25 H, o

1 O

-M.--

3.2 15 Revision 4 w

311 m strucmeni < reel. Steel structures are designed for the following loading combinations without exceeding the specified stresses:

D+L Stress limit = f, D + L + T + H, + E Stress limit = 1.25 f, o

D + L + T + H, + W Stress limit = 1.33 f, o

In addition, for structural elements, carrying mainly canhquake forces, such as struts and bracings:

D + L + T, + H, + E Stress limit = f, 3.2.1.4.3 Seismic Category I Structure During Accident and SSE O

The Seismic Category I structures are proponioned to maintain elastic behavior when subjected to various combinations of dead loads, thermal loads, seismic and accident loads. The upper limit of clastic behavior is considered to be the yield strength, F, for steel (including reinforcing steel) is y

considered to be the guaranteed minimum given in appropriate ASTM specifications. The yield strength for reinforced concrete structures is considered to be the ultimate resisting capacity as calculated from the " Ultimate Strength Design" ponion of the ACI 318-71 Code. The allowable shear and axial stresses are also in accordance with the " Ultimate Strength Design" ponion of the above code, e

Revision 4 3.2-16

d 321411 &ncrete. Concrete structures satisfy the most severe of the following loading combinations:

?

8 i

U = 1.05 D + 1.05 L + 1.25 E + 1.0 T3+1.0H3+1.0R i

U = 0.95 D + 1.25 E + 1.0 T + 1.0 H3+1.0R 3

U = 1.0 D + 1.0 L + 1.0 E' + 1.0 T, + 1.25 H, + 1.0 R U = 1.0 D + 1.0 L + 1.0 E' + 1.0 T + 1.0 H3+1.0R 3

j-U = 1.0 D + 1.0 L + 1.0 A + 1.0 T + 1.25 H, o

121412 Srmemr21 < teel. Steel structures satisfy the most severe of the following loading combinations without exceeding the specified stresses:

I D + L + R + T + H, + E '

Stress limit *l = 1.5 f, o

D+L+R+T3+H3 + E' Stress limit *I = 1.5 f, I

1 D + L + A + T, + H, Stress limittal = 1.5 f,

!O Stress in some of the materials may reach yield strength. If this is the case, an analysis is made to i

determine whether the energy absorption capacity of the structure exceeds the energy input. The i

resulting deflection or distortion is reviewed.

l t

a a

i

[a]

Sfaximum allowable stress in bending and tension is 0.9 f. Sfaximum allowable stress in y

j shear is 0.5 f.

y 3.2-17 Revision 4 4

I 3.2.1.4.4 Design i oads The stmetures are designed for applicable loads and load combinations given in the previous sections. This section defines the various loads.

311441 ne,d in,de. Dead loads consist of the weight of the concrete, stmetural steel, interior walls, equipment, main piping, contained fluids, cable trays, and duct work.

3.2 1 4 4 2 i ive in,dc. Live loads for the design of the structural framing members are consistent with the intended use of the structure and the recommendations of the Uniform Building Code,1967 Edition. The live loads that were used in the design of the stmetures are given in Table 3.2-1, 3 2.1 4 4.3 Fmhnu,ke in,dc. Earthquake loads are in accordance with Section 3.1.6.

12144. Wind and rnrnadn innac. The wind and tornado loads considered in the design of the structures are in accordance with the criteria given in Section 3.1.3.

1_2.1 4 4 5 Mydrner, tic in,dc. The exterior walls and base slabs of the stmetures are designated for hydrostatic loads associated with an upstream failure of Grand Coulee Dam. Water level at the site would be at Elevation 42.75 feet MSL. The stmetures would not become buoyant as a result of this water elevation.

121446 Negrive,nreunre. The Fuel Building and Auxiliary Building are maintained at a negative pressure. The pressure differential between the inside and outside does not exceed O'.1 inches of water. The control room in the Control Building is maintained at atmospheric pressure.

121447 Blact in,de. The pressure due to 3000 tons of TNT exploding at the river midstream opposite the Intake Structure has been factored into the design.

j Revision 4 3.2-18

i 311 s necign and Annlytic Prnceduret 3.2.1.5.1 Analytical Methods for Seismic Category I

{

Stmetures (Original Procedure) l l

r j

Classical theory, empirical equations, and numerical methods are used as necessary in the analysis of j

the stmetures.

l-4 i

Loads and load combinations delineat'ed in Section 3.2.1.4 are considered. For dead loads, live t

loads, wind loads, and tornado loads, all of the methods listed above are used. Wind loads and i

tornado loads are converted to equivalent static loads and are applied to the structure either as 4

l uniform or concentrated loads. This is discussed in Section 3.1.3. The following computer programs are used in the static analysis:

i

\\

i P

l (1) "Stmetural Engineering Systems Solver" (STRESS) (Bechtel CE 309-3) - this program i.

performs linear analysis of framed stmeture (plane and space) for static loads by the l

stiffness method.

i

}

(2) " Composite Beam Analysis" (Bechtel CE 585) - this program analyzes and designs t

i simply supported composite beams.

i l

(3) "Stmetural Design language" (Bechtel CE 901) - a method formulated for digital j

computer solution and based on a program commonly called ICES-STRUDL.

t l

l Classical methods used in the analysis are standard textboolcs and hanchks as used in universities and engineering practice.

The seismic analysis of the structures is covered in Section 3.1.6. The mathematical models used are also shown in the aforementioned section.

3.2-19 Revision 4

l l

l 3.2.1.5.2 Design and Analysis Procedure Used for the Complex The structures of the Complex were analyzed for seismic loads as described in Section 3.1.6. ne computer program used in the seismic analysis is described in Section 3.1.6.2.1. For the seismic analysis of the modified Complex the actual equipment and floor loadings were used in place of the floor live loads specified in Table 3.2-1.

311521 New <rmenir,1 elements. Design methods used for the new structural elements for the Control Building were in accordance with applicable portions of the codes and specifications listed m Section 3.2.1.3.2. Concrete and reinforcing steel were proportioned using the Strength Design Technique in accordance with ACI 318-77. Structural steel members and plate were designed in accordance with the AISC specifications.

criteria fnr Rntr<'

el Bolts used to fasten the 3-inch-thick plate to the R wall and the new concrete walls to the existing N and R walls were in accordance with the requirements of ASTM A-354 Grade BD. The allowable design shear force resisted by each bolt was calculated using the following formula:

V=

LE FS where V = allowable bolt shear force in kips g = coefficient of friction at the interface between old and new elements, taken as 0.7 F = maximum bolt load of 200 kips for 2 inch diameter bolts Revision 4 3.2-20

E A

m FS =

factor of safety, taken as 2 'l I

i L = factor to account for losses, a

Losses from the following factors were considered:

1 (1) Creep and shrinkage of the concrete and masonry walls.

(2) Initial relaxation of the bolt.

(3) Long-term relaxation of the bolt.

(4) Temperature losses.

Criterin for Shear Knidc-O The allowable design shear force for shear studs was 1/2 the values given in Table 15 of the Nelson Division of TRW, Inc., publication " Design Data 10 - Embedment Properties of Headed Studs",

TRW Inc.,1974.

[a] The calculation in which this safety factor was applied did not include the potential parameter variations used to determine the low frequency floor response spectra peak broadening. A conservative consideration of these potennal variations leads to determmanon of a lower bound factor of safety of 1.1. However, as discussed in Section 3.1.6.2.9, the vertical growth in the wall panels in an canhquake due to the development of flexural cracking would more than compensate for the potential reduction in dead load due to creep and shrinkage effects, and a lower bound factor of safety of 1.3 would result. Transfer of Shear Forces to Bedrock: The new concrete shear walls are supponed by reinforced concrete grade beams placed on bedrock and connected to the existing structure. Therefore, they will participate with the existing i

foundation in the transfer of shear forces to the bedrock.

O 3.2-21 Revision 4

n 1 < 2 ? Origimi emement elements. The structural elements used in the originally designed anc as-built Complex consist of reinforced concrete construction for walls and slabs, structural steel members, and of masonry construction for shear walls and divider or panition walls.

Design methods and evaluations of structural adequacy of the stnictural elements composed of reinforced concrete and structural steel were in accordance with applicable ponions of the codes and specifications listed in Section 3.2.1.3.1.

The following sections describe the analysis procedure for single wythe, double wythe and composite walls having safety significance for consideration of all in-plane and out-of-plane loads and the interaction of these loads. The walls having safety significance are walls: (a) used as shear walls, (b) either supporting or within 2 feet of safety-related equipment, (c) used as train separation for common mode failure consideration, or (d) used as design basis equipment protection, e.g., tornado and flood.

O In Plane I n, ding Conditinnt:

In order to evaluate the masonry walls, the in-plane shea' force in each horizontal load carrying wall element corresponding to the governing loading condition was first determined. The wall capacity was then determined in accordance with the governing behavioral mode and compared with the shear force.

Evnhintinn of Canncirv:

For evaluating in-plane capacities of the masonry walls of the Complex, the governing capacities were determined from consideration of each of the following potential behavioral modes: (a) flexure, (b) slidir,g, and (c) diagonal tension. In addition, vertical shear capacity was examined. Equations for each of these behavioral modes are discussed below, with appropriate references. Capacities calculated by application of these equations are based on results obtained from the testing program described in Appendix A of PGE-1020 h

W Revision 4 3.2-22

l i

Notations:

O l

'As = area of masonry portion of wall section, square inches A, = area of cencrete including cell grout and core, square inches Af = As + A = Total area of section, square inches g

A,e = cross-sectional area of steel column, square inches N, = total number of columns crossing the shear plane Y = shear force resistance of the frictional component of beam to column connections, Ibf b

V, = shear force resistance developed by shear friction of reinforcing steel on vertical edges of wall panel, Ibf V = V + V. Ibf i

b s

f,' = specified compressive strength of concrete, psi f '= compressive strength of block, psi 3

l 1

f,' = computed compressive strength of composite section, psi f = specified yield strength of reinforcing steel, psi y

f, = specified yield strength of column steel, psi y

-.JAL,.Wia -..

3.2-23 Revision 4

h=

height of wall panel, inches I., = width of wall panel, inches thickness of wall, inches t =

v=

nominal shear stress capacity of wall panel, psi t

coefficient of shear friction

=

g p, = distributed vertical reinforcing steel ratio p: = concentrated end vertical reinforcing steel ratio Ph = horizontal reinforcing steel ratio 00= wall compressive stress due to normal load, psi.

(1)

Flerural mnde:

(a) T3nuble curvnnire:

The procedure for determination of capacity of a wall behaving in the double curvature mode is described in Section 3.4.2.2 of PGE-1020 and the equation developed therein is as follows:

v = (l /h) (1.94 pe y + 0.93 p f + 0.94 a )

f t

w yy o

1 Revision 4 3.2-24

i b

(b) Single curvamre:

O For behavior in the single curvature mode, the top edge is considered free and the bottom edge is considered restrained. The magnitude of this moment restraint depends on the venical reinforcing steel, the effective panel normal load at the top edge, and the venical shears as limited by the beam-column connection and the horizontal reinforcing steel across the two venical edges.

e ne equation for the single curvature shear capacity is:

(1.,/h) (0.97 pe y + 0.46 py y + 0.47 0 ) + V /ht f

f v=t 0

g (2) Sliding mode:

The method for determining sliding resistance at a wall slab interface of the Complex walls is presented in Reference 4. The total sliding resistance is developed as the summation of the resistance offered by the embedded steel columns, with the shear strength of the steel taken as f //3, and the shear friction developed by the normal force and the venical y

reinforcing steel crossing the shear plane. The equation for the sliding resistance is:

j c + 1.4 (p, + pe) f + (A /1 t) (f,//3) ((N - 1.5)/(N, - 1)]

v=

f o

y 3c y

e where the coefficient of friction,, for the normal force is taken as the weighted average based on the relative areas of bearing composed of mortar bed joints and concrete in the block cell and the wall core. In the absence of any code-specified value, the coefficient of friction for the mortar bed joints is taken as 0.75, which is a lower bound value used in Reference 5. The numerator in the multiplying factor for the column resistance, (N, - 1.5).

O 3.2-25 Revision 4

represents the number of columns available to resist sliding in the entire wall section and is ec to the total number of columns crossing the shear plane minus one end column and half the other end column. The term (N, - 1) in the denominator represents the number of panels; therefore v = (0.75 A /A, + 1.4 A /A,) o + 1.4 (p, + pe) f t

3 g

o y

+ (A /l,t) (f,//3) [(N -1.5)/(N, - 1)]

se y

e (3) Dingonni ten < inn (the'ri mnde:

For evaluating the diagonal tension related shear capacity of a wall panel, the ACI deep beam equation is used, which gives the shear stress, v, as e

v, = (3.5 - 2.5 Mil,V) 2/f '

s O

where M and V are the moment and shear force at the section. For a cantilever shear panel, M = Yh.

v, = (3.5 - 2.5h/1,) 2/f,'

The compressive strength of the grouted masonry composite weighted average of masonry and concrete, or (f,' = (f ' (Aa ^w) + f ' (A /A )

l b

c g

Accounting for the normal stress, o, on the wall section, the resulting shear capacity, v *,

o e

is v ' * {[(V Y 0 /2)2 -(c /2/]

c c

0 o

Revision 4 3.2-26

t t

t (3

The b rizontal and vertical reinforcing steel provide additional contnbutions to the diagonal tension strength.

l i

{

Test results from specimens with height-to-width ratio of 0.5 (Reference 6) and I

height-to-width ratio of 1.17 (though titled as 1.0 in Reference 7) indicated that the cracking i

plane engages both the horizontal and vertical reinforcing steel; therefore, these may be considered as equally effective in providing the shear resistance.

Thus the ftual equation for the diagonal tension mode is t

v = v/ + 0.5(pv + ph h/1 ) f f

y i

t (4) Venient 9henr:

i O-The vertical shear at embedded columns resulting from earthquake motion was also f

checked. The vertical forces are obtained from the finite element model and used in the load combinations in Section 3.2.1.4.2.1. The resistance is obtained by combining the shear friction resistance of the horizontal reinforcing steel (ACI 318-77, Section 11.7) and i

the resistance of the embedded bolted beam-column connection to slipping.

i R = 1.4 A,f + Evr y

y i

A, = area of horizontal reinforcing steel crossing a hypothetical vertical crack along the

]

embedded columns, square inches.

i l

f = yield stress of reinforcing steel, ksi y

t i O 3.2-27 Revision 4

v = 1e resistance of the bolted beam-column connection to slippage, based on a clamping force t

of 0.7 of the minimum tensile strength of the bolts 120 ksi) and a coefficient of friction of 0.35 (based on Reference 2).

3.2.1.5.3 Design and Analysis Procedure Used for the Fuel Building Steel Superstructure The Fuel Building steel superstmeture is basically a steel-framed, braced stmeture supporting a 125-ton overhead crane. Lateral loads are resisted by frames in the East-West direction and by bracing in the North-South direction. The superstructure was designed and analyzed for seismic loads as described in Section 3.1.6.2.8 and for tomado loads as described in Section 3.1.3. The computer program used in the analysis is identified in Section 3.1.6.2.8.

3M 1 A strucnirni Accepennce criterin O

3.2.1.6.1 Original Procedure Except as noted in Section 3.2.1.4.2 allowable stresses are as specified in the applicable codes.

Tables 3.2-2 through 3.2-4 give calculated results for the principal stmetural members of structures other than the Containment and Control Building Complex. Seismic stress contributions are listed separately to indicate their portion of the total stress.

In order to prevent loss of function of the structures, values are established to control the maximum stmetural deformations to within defined limits.

The limiting values for deformation and strength are normally set by the need to maintain structural integrity, the need to prevent stmetural deformation from displacing the equipment to the extent that the equipment suffers a loss of function, and the need e

Revision 4 3.2 23

O to prevent deformations which would inhibit the stmeture's ability to control leakage. Structural deformations were never the controlling criteria in the design of stmetures listed in Section 3.2.1.1. The allowable strains for concrete are in accordance with ACI 318-63.

3.2.1.6.2 Procedure Used for the Complex-n 1 611 In-nhne inading ennditinnt. Concrete block walls used in Seismic Category I structures, including the Complex, are designed to the UBC requirements for masoruy. The major shear walls of the Complex are constructed of a high-strength concrete core, either reinforced or unreinforced (nonmasonry structural element), sandwiched between two wythes of reinforced grouted concrete blocks (masonry units). Since the provisions of the UBC applicable to masoruy constmetion do not address a combination of masonry and nonmasonry units, the shear walls of the Complex are not addressed directly by the UBC. However, Sections 106 and O:

107 of the UBC allow departure from certain detailed code formulae and quantifications where such departures are supported by substantiation through testing. In addition, testing is the basis upon which most code criteria have been established. Accordingly, application of test results in the determination of wall capacities is appropriate.

Such a testing program, conducted during the period September 1978 through February 1979, is described in Appendix A of PGE-1020. The testing utilized 23 specimens which were designed to simulate parameters of the walls in the Complex. The materials used in the construction of these specimens as well as their aspect ratios and thicknesses were similar to the wall panels in the Complex. The testing program was extensive for its purpose and was typical of testing performed to substantiate code compliance.

The test results indicated that the hybrid unit of steel column-composite wall will have a lower bound diagonal tension capacity of 300 psi for the large percentage of composite walls which

\\

have an aspect ratio of approximately 0.5. However, this behavior relies 3.2 29 Revision 4

upon bond between the embedded steel frame and the surrounding concrete. In the development of the capacity criteria, this important stmetural aspect is conservatively neglected.

The capacity values obtained in the tests are not factored directly into the computation of the capacities of the Complex walls. Rather, the characteristics of the composite walls demonstrated by the test specimens formed the basis for development of theoretical equations which predicted the shear capacities of the individual wall panels as functions of percentage of vertical and horizontal reinforcing steel, the embedded steel columns, and the vertical load bearing on the wall panels from the dead load of the wall above.

The formulae given in Section 3.2.1.5.2.2, based upon understanding of behavior gained from the testing program, reflect at least the same level of conservatism as code equations.

3117 \\fnterinic Onnlity Contrni nnd S.necint Constructinn Techni.m. ee 3.2.1.7.1 Original Construction of Seismic Category I Stmetures The following major structural materials are used in the constmetion of the Seismic Category I and Seismic Category II structures:

Concrete:

4 Auxiliary Building f'c = 3000 psi Fuel Building f'c = 3000 psi Intake Stmeture f'c = 3000 psi Control Building f'c = 3000 psi MSSS f'c = 3000 psi Turbine Building f~c = 3000 psi Shop building f'c = 3000 psi Revision 4 3.2-30

l 4

Chlorine Building f'c = 3000 psi.

Administration Building f*c = 3000 psi

- Security Building f'c = 3000 psi TSC f'c = 3000 psi Cooling tower f'c = 4000 psi (veil) 5000 psi (columns)

Reinforcing steel:

ASTM A-615, Grade 40 & 60 Structural steel:

ASTM A-36 High-strength bolts:

ASTM A-325 Stainless steel liner plate:

ASTM A-167. Type-304 Concrete block masonry:

ASTM C-90, Grade PI 3.2.1.7.2 Control Building Modification Construction relating to modification of the Control Building was performed by Bechtel as described in Section 3.2.1.1.4, Bechtel performed design engineering, prepared specifications.

obtained PGE's approval of the construction documents, and was generally under PGE's supervision and surveillance during construction. work. Bechtel also had a staff of qualified supervisory personnel and inspectors assigned to the jobsite to ensure that the work was -

accomplished in accordance with the specifications and drawings.

371.771 rnneructinn materimic and merificatinne. Basically, four types of materials were used in the construction of the Control Building modifications. They are:

(1) Concrete:

f ' = 3500 psi e

1 (2) Reinforcing steel:

ASTM A-615-78, Grade 60 (3) Structural steel and 3-inch plate:

ASTM A-36 3.2-31 Revision 4

(4)

Bolts:

(a) High-strength bolts for stmetural steel: ASTM A-490 (b) High-strength bolts for 3-inch plate:

ASTM A-354-78, Grade BD A comprehensive set of documents, including specifications and drawings, was issued by Bechtel and approved by PGE for the entire modification work. These documents contained the technical provisions plus the necessary general and special conditions. The technical provisions were specific as to the scope, detail and quality of work required and were used by the inspectors along with the appropriate drawings to determine the acceptability of the work. In general, the technical provisions referred to the applicable standards and codes as the basic governing documents.

3 7 1_7 2 2 Qualirv quurance and n,nalirv control.

O.

PGF Qunlirv Aunrnnce As the principal owner and the operator of the Plant, PGE was responsible for the administration l

and control of the total QA program as described in this section. In carrying out this responsibility, 1

PGE delegated to Bechtel the responsibility for the QA of the engineering, procurement, and constmetion activities. PGE audited this delegated responsibility in accordance with the PGE Nuclear Plant Quality Assurance Program for Operation (NPQAP/0), which describes the overall QA administration and control including the interface controls between contracted organizations and PGE.

i Rechtel Quality Aunrnnce-The Bechtel QA Program plan for use by the Bechtel Thermal Power Organization during design, procurement and implementation phases of the Control Building Revision 4 3.2-32

i i

modification is described in Bechtel Topical Report BQ-TOP-1, "Bechtel Quality Assurance Program for Nuclear Power Plants", Rev. 2gs) l l

Rechtel Onnlity Inntrol:

The Bechtel quality control program requirements, procedures and instructions implemented by Bechtel construction quality control engineers during the modification of the Control Btiilding are described in the Bechtel Construction Quality Control Manual. This manual was prepared for use by Bechtel construction quality control engineers to assure that the required quality verification and inspection activities were performed. Project quality control instructions were issued by the division chief constmetion quality control engineer and provided supplementary technical and administrative direction to the project construction quality control engineer at the jobsite. Two types of project quality control instmetions were used to supplement the requirements, procedures, and instructions contained in the Constmetion Quality Control Manual. They were administrative and technical.

' O Administrative quality control instructions were used to convey special and unique project provisions that further specified the construction quality control program on this specific project by modifying or superseding the requirements, procedures and instmetions contained in the Construction Quality Control Manual.

Technical quality control instructions were used to convey information which supplemented but did not modify or supersede the requirements, procedures and instructions contained in the Construction Quality Control Manual.

3 2 1_7_7 1 Rnecial enmtmerinn rechninna. No special construction techniques were utilized in the course of carrying out the modification to the Control Building. However, durin;; most of the j

constmetion period the Plant was in operation and, therefore, the performance of the work was sequenced in such a way as not to reduce the strength of the shear walls or the structural capacity of the Complex below the level required to withstand the loading combination involving the SSE.

3.2-33 Revision 4 l

1 l

Also, de details of work were developed to preclude potentials for creating hazardous conditions disrupting operations of the Plant. Details of Bechtel constmetion procedures and the modification work, including sequence of constmetion, are described in Section 4 of PGE-1020m and Licensee's Testimony on hiatters Other Than Stmetural Adequacy of the hfodified ComplexW 3.1 1 R Testing and intervice intnectinn Renuirernente 3.2.1.8.1 Original Procedure No structural preoperational testing of the Seismic Category I and Seismic Category II structures was performed. During the life of the Plant, periodic inspections of the structures are made to visually inspect for apparent structural deterioration such as large cracks and excessive deflection of stmetural members. All seam and plug welds in the SFP liner plate were vacuum box tested upon completion of the welding. Where vacuum box testing was not possible, liquid penetrant testing was performed. The SFP has a system that provides for leakage to be detected at any time in the life of the Plant. This system consists of 2-inch by 2-inch troughs under the liner plate which lead to a collection system where leakage can be observed.

3.2.1.8.2 Procedure Used for the Complex l

Transfer of shear force from the existing west and east walls of the Control Building to steel plate and new reinforced concrete wall elements is accomplished principally by friction with a clamping (normal) force supplied by through-wall post-tensioned bolts. A surveillance program was employed to ensure that the tension force in the bolts did not fall below design levels.

1 31.1 O Fnundarinnt l

The foundation slabs for Category I stmetures are made of reinforced concrete. Section 3.2.1.3 lists those documents applicable to the foundations of stmcrures. The loads and load combinations Revision 4 3.2-34

_ =

i i

i l

described in Section 3.2.1.4 are applicable to the design of foundations. Design and analysis procedures applicable to foundations are described in Section 3.2.1.5. Criteria for foundations are the same as those listed for the stmetures in general (see Section 3.2.1.6). Description of the reinforced concrete and structural steel used in the construction of foundations is in Section 3.2.1.7.

Floor slabs were coated to prevent possible absorption of contaminated fluids and to facilitate decontamination.

12 2 SPFNT FITFT POOI_ AND FTIFT STORAOR R ACKS

]

The SFP is the storage space for irradiated fuel from the reactor.

1221 nesign mer.

The original design bases for the SFP and rack is designed for the following:(10 !! 12)

(1) Store 1408 fuel assemblies with maximum enrichment of 4.5 wt% and an average region burnup of 55,000 mwd /MTU. Some of the 1408 storage cells are used to store fuel rod storage canisters, radioactive filters, debris or specimen assemblies associated with refueling evolutions.

(2) Maintain k,g s0.95 during nonnal conditions with SFP water between 40*F and 140*F and a boron concentration of 0 ppm (demineralized water).

(3) Maintain k,g 50.95 for abnormal conditions, including:

(a) Loss of normal SFP cooling (water temperature of 212'F at SFP surface).

(b) Drop accidents involving items which may be transferred or handled over the fuel racks. These items are shown in Table 3.1-4.

3.2-35 Revision 4

l l

l (c) Accidental drop of a fuel assembly in any position or orientation.

1 (d) Effects on fuel assemblies resulting from an earthquake or missile (See Table 3.1-4).

l During abnormal events, a soluble boron concentration of 2000 ppm is assumed.

Variations in rack dimensions, neutron absorber parameters, fuel parameters, and fuel location permitted by fabrication tolerances are included in the analysis. Calculations l

were performed to determine the sensitivity of k,g to abnormal SFP water temperatures which may be encountered during a loss of cooling water incident.

l (4) Sfaintain fuel cladding integrity in the event forced cooling is lost and cooling occurs by SFP boiling (212*F) at the water surface. Evaporative losses are made up by a variety of sources as discussed in Section 4.3.1.

O (5)

The structural design of the spent fuel racks is in accordance with NRC Standard Review Plan 3.3.4 Appendix D, " Technical Position on Spent Fuel Racks."

Construction materials for the racks conform to the requirements of ash!E Section III, Division 1 Subsection NF.

The governing code for rack design and analysis is AShiE Section III, Division 1 Subsection NF for Class 3 component supports. The design loads are specified in Reference 10.

(6) The entire structure, including the spent fuel racks, has been designed to Seismic Category I requirements.

O1 Revision 4 3.2-36

C'\\

()

(7) The dose rates at the surface of the SFP from spent fuel assemblies do not exceed 2.5 mrem /hr during spent fuel transfer and storage. Dose rates at the outside surface of u

the walls of the SFP do not exceed the maximum radiation zone level for the area ).

(S) A fuel handling accident involving dropping of a single spent fuel assembly in the SFP from its maximum attainable height will not result in offsite radiation doses to the public exceeding the values calculated in Secnon 6.2.

(9) A spent fuel shipping cask shall not be moved into the Fuel BuildingU U.

3 2 2 ' sycem nsign The SFP is a reinforced concrete structure with seam-welded stainless steel plate liners. The pool 3

2 volume is approximately 51,900 ft with a surface area of 1300 ft. The pool is filled with borated water which is maintained at a concentration of a2000 ppm boron.

The spent fuel assemblies are stored in storage racks in parallel rows having a center-to-center distance of 10.5 inches in both horizontal directions. The racks are freestanding modules containing a neutron absorber (Boroflex). Burnable poison rod assemblies, neutron-source assemblies and thimble plugging devices removed from the reactor are also stored in the SFP.

Adjacent to the SFP are two small pools. One is the fuel transfer canal which is connected to the refueling cavity (inside the containment) by the fuel transfer tube. The other is the spent fuel cask loading pit. Leak-tight doors have been provided between the SFP and these two smaller pools to allow underwater movement of the assemblies between pods. The doors open into the SFP so that when the doors are closed with the adjacent pools drained, water pressure tends to seal the doors. Additionally, each door is equipped with an inflatable boot seal around its periphery which is inflated when the door is closed using the instrument and service air system.

O v

3.2-37 Revision 4

The water level in the SFP is maintained to provide at least 23 feet of water above the top of a spent fuel assembly in the storage racks, and at least 9.5 feet above the active ponion of the fuel assembly during fuel transfer operations. This water barrier serves as a radiation shield, enabling the gamma dose rate at the pool surface from the spent fuel assembly to be maintained at or below 2.5 mrem /hr.

Overflows from the SFP drain into the SFP ventilation system (AB-4) exhaust ductwork and are directed to the dirty waste drain tank.

Beneath the SFP liner is a network of monitoring trenches which will collect any leakage through the liner. The trenches drain through normally open valves to the diny radioactive waste treatment system. The leak detection valves are arranged into manifolds that are inspected periodically to monitor for SFP liner leakage.

Ventilation systems remove gaseous radioactivity from the atmosphere above the SFP and h

discharge through the Plant vent. The ventilation systems are described in Section 5.2. These ventilation systems are monitored for radioactivity by Process and Effluent Radiation Monitoring Systems (PERMS) which are described in Section 5.5.

A SFP Area Radiation Monitoring System (ARMS) is provided for personnel protection and general surveillance of the SFP area. These ARMS are discussed in Section 5.6.1.

The SFP water chemistry is sampled and maintained in accordance with Section 4.1.2. The environment to which the SFP liner and spent fuel are exposed is not conducive to corrosion.

O Revision 4 3.2-38

(3 V

1, ' i nr<ign Fvention The center-to-center distance between the adjacent spent fuel assemblies and the fixed neutron absorber are sufficient to ensure a kg s0.95 even if unborated water and fresh nondepleted fuel, enriched in U-235 to 4.5 wt"c, are in the SFP.

The design of the spent fuel storage rack assembly is such that it is impossible to insert the spent fuel assemblies in other than prescribed locations, thereby preventing any possibility of accidental criticality.

Mechanical and electrical stops are provided on the Fuel Building bridge crane rails to prevent an inadvertent traverse of the pool with heavy loads.

O The only requirement to assure adequate coolmg of the spent fuel is to maintain the water level in the SFP above the spent fuel elements. Section 6.3 analyzed the loss of forced SFP cooling due to failures of the non-Seismic Category I piping and the fuel transfer doors and determined that the loss of SFP cooling and inventory would not lead to uncovering of the fuel. Sufficient time would be available to establish makeup flow to the SFP.

Lines entering the SFP which could siphon the pool to Elevation 76-feet 7-inches or below (approximately 10 feet above fuel elements) are equipped with siphon breakers at Elevation 83-feet 11-inches.

17 7 4 Test < 2nd intnectinn<

Neutron absorber coupons are located in the SFP and used for periodic verification of absorber effectiveness. The verification surveillance is every 4 years. Coupon inspection includes visual inspection, hardness, weight, and dimensional measurements.

,3 U

3.2-39 Revision 4

1 The SFP !!ner leak detection manifold is inspec:ed periodically to monitor for SFP liner leakage.

i U 2M instmment,rinn Anni;cnrinn A level switch is provided in the SFP for the purpose of annunciating high and low water levels to the control room. Local level indication is installed in the SFP.

1 SFP water temperature indication and a high temperature alarm on the sequence of events recorder are provided in the control room.

3.2.2.6 SFP Structure Re-evaluation for Revond Desion Rasic Reismic \\forinnt The SFP stmeture was evaluated for ground motions that would result from the occurrence of a conservatively postulated Seismic Margin Earthquake (SME).

g Cascadia Subduction Zone earthquake source interface events in the magnitude range of M 8 to 9 and intraslab events in the range of M 7 to 7 la, and random crustal earthquakes in the range of M 6 to 6 v2 were considered to envelop hypothetical earthquake ground motion exposures to the Trojan site.

The bounding case SME was determined to be a Cascadia Subduction Zone intraslab eanhquake of magnitude range M 7 to 7 la at a hypocentral distance (source to site distance) of between 55 and 60 km. The corresponding peak horizontal ground acceleration at Trojan would be 0.38 g.

The SFP structure was deterministically found to have large to very large capacity margins over SME demands. Peak horizontal ground accelerations on the order of 2 g would be required to l

j approach the threshold of unacceptable damage to the SFP walls. There are no rational earthquake sources that could produce anywhere near this level of ground acceleration at the Revision 4 3.2-40

i 0

i

\\

l Trojan site. Here is, therefore, a very high level of confidence that the SFP structure would not i

be damaged by the postulated occurrence of a SME.

1

?

A probabilistic assessment was also performed that concluded that the annual probability of i

unacceptable SFP wall structural performance due to an earthquake producing several times the SME level of ground acceleration would be considerably less than 5x10 8, d

I i

f 1

4 j

i 1

2 t

i i

!O 4

i l

l t

t e

O 3.2-41 Revision 4

31 AttYTT TARY SYSTFMS This section discusses the auxiliary systems that are used to support the storage of spent fuel at Trojan. This section includes discussions on the fuel handling system, SFP cooling and demineralizer system, component cooling water system, service water system, compressed air system, makeup water treatment system, equipment and floor drain systems, Plant discharge and dilution structure, primary sampling system, fire protection system and program, control room habitability, and seismic instrumentstion. These systems do not perform any safety l

functions with the reactor defueled.

311 FIIFT MANDI ING SYSTFM The fuel handling system consists of equipment and structures utilized for handling spent fuel assemblies during fuel transfer operations. This discussion is limited to fuel handling equipment used for transfer operations within the SFP. The transfer of fuel to the Containment Building or to a spent fuel shipping cask is prohibited under Trojan's current license.

1 1.1 1 Design Bases j

The fuel handling system is designed to minimize the possibility of mishandling or maloperation that could cause fuel damage and potential fission product releases. The following design bases apply to the fuel handling system:

(1) Fuel handling devices have provisions to avoid dropping orjamming of fuel assemblies during transfer operations.

O 3.3 1 Revision 4

(2) The fuel handling equipment has been designed for the loading that would occur during a Safe Shutdown Eanhquake (SSE). The fuel handling equipment will not fail so as to cause damage to any fuel elements should a SSE occur during fuel transfer operations.

(3) The hoist used to lift the spent fuel assemblies has a limited maximum lift height which is detennined by the length of the long-handled tool, so that the mimmum required depth of water shielding is maintained.

Environmental conditions of the fuel handling equipment, such as exposure to borated water and high humidity, are considered in the design and selection of the material.

3.3.1 2 Svtrem De<crintinn 3.3.1.2.1 General Description Fuel assemblies are moved in the SFP using the SFP bridge hoist. When lifting spent fuel assemblies, the hoist uses a long-handled tool to assure that sufficient radiation shielding is maintained. Fuel assembly inserts, such as thimble plugs, burnable poisons rods, rod control clusters, and source rods, may also be transferred between positions within the SFP.

3.3.1.2.2 Component Description 1.11711 Finel Nilding bridge crane. The Fuel Building bridge crane is an indoor electric overhead travelling bridge crane complete with a single trolley and all the necessary motors, control, brakes, and control station. The main hoist of the crane is rated at 125 tons and the auxiliary hoist at 25 tons. The crane and accessories have been designed and constmeted for indoor service and were designed to handle new and spent fuel containers between the railroad cars and loading and unloading pits. Movement of 3.3-2

I heavy ! cads outside the approved load path discussed in Section 4.2.1 must be authorized prior to implementation. Neither the main hoist nor the auxiliary hoist are capable of being immersed in SFP water.

111212 SFP hHdoe hnist. The SFP bridge hoist is a wheel-mounted walkway, spanning the SFP, which carries an electric monorail hoist on an overhead structure. The fuel assemblies are moved within the SFP by means of a long-handled tool suspended from the hoist.

l L

The manufacturer's construction drawing details include the following information:

The SFP bridge hoist has a 2000-pound capacity with a 21-foot maximum lift. The hoist l

i l

uses stainless steel Type-304 cable and a safety load hook.

The SFP bridge hoist incorporates design features to minimize the probability of a fuel handling accident. These features include:

l (1) The SFP bridge cannot be moved unless the hoist is in the full up position (with the exception of jogging). An interlock prevents simultaneous operation of the SFP bridge drive and hoist.

1 (2) Hoist travel in the up direction is terminated by a limit switch that also provides the

" full up" interlock for the bridge drive with a hoist geared limit switch providing backup. Hoist travel is designed to maintain safe shielding depth of fuel assemblies by limiting maximum lift height with the spent fuc! handling tool attached.

4 (3) A geared limit switch is provided to automatically stop downward motion when the hoist drum does not have a sufficient number of cable wraps remaining.

i l

O 3.3-3

(4) Indexing of the SFP bridge crane to spent fuel storage racks is accomplished by means of a grid system laid out on the bridge rails and on the handrail.

331.711 Snent fuel handling inni. The spent fuel assembly handling tool is a long handle tool l which is about 30 feet long that is used to move spent fuel assemblies in the SFP. The tool is mechanically operated by an operator on the SFP bridge. The tool may also be used to handle debris baskets and specimen assemblies. The length of the tool assures that a minimum depth of 10 feet of water will remain above the active fuel during fuel movements.

The spent fuel assembly handling tool employs four cam actuated latching fingers, which grip the underside of the fuel assembly top nozzle. The operating handle that actuates the fingers is located at the top of the tool. When the fingers are latched, a lock pin is inserted into the l

operating handle (held by a ball and detent) to prevent accidental unlatching.

3_3_1 1 Design Fvninnrinn 3.3.1.3.1 Seismic Consideration The maximum design stress for the stmetures and for parts involved in gripping, supporting or hoisting the fuel assemblies is one-fifth the ultimate strength of the material. This requirement applies to normal working load and emergency pullout loads, when specified, but not to earthquake loading. To resist design basis earthquake forces, the equipment is designed to limit the stress in the load bearing parts to 0.9 times the ultimate stress for a combination of werking load plus design basis earthquake forces.

O Revision 4 3.3-4

i i

g y)

(9) Valves and piping.

(10) Instrumentation.

The SFP cooling and demineralizer system components are located in the Auxiliary Building and Fuei Building.

The SFP cooling and demineralizer system is a closed-loop system consisting of three subsystems:

the cooling system, the purification system, and the skunmer system.

i The SFP cooling subsystem utilizes two SFP cooling pumps installed in parallel and two SFP cooling water heat exchangers installed in parallel with a common pipe between the pumps and the heat exchangers. The SFP cooling pumps draw suction from the SFP through a common strainer located above the spent fuel assemblies and discharge back to the SFP through the SFP b

cooling heat exchangers.

The SFP purincation subsystem utilizes the SFP purification pump to divert a small fraction of the total flow through the SFP purification filter and/or the SFP demineralizer. Both the filter and demineralizer have sufficient capacity to recirculate the entire SFP water inventory at least once every two days. This purification loop is adequate for removing fission products and other contaminants which may be introduced by a leaking fuel assembly. Portable vacuum filtration units may also be used to support special cleanup evolutions.

The skimmer subsystem consists of the SFP skunmer pump and two 1-1/2-inch diameter standpipe and valve assemblies with quick disconnects to which a floating skimmer can be connected by a flexible hose. The SFP skimmer pump can draw suction from the top water surfaces of the SFP and discharge through the skimmer filter or empty filter housing back to the SFP.

fV 3.3-7

1 lli Onign Fvnhnrinn A single SFP cooling pump and a single SFP cooling water heat exchanger can maintain SFP temperatures s140*F.

All lines entering the SFP which could siphon the pool to Elevation 76 feet 7 inches (approximately 10 feet above fuel elements) or below are equipped with siphon breakers at Elevation 83 feet 11 inches.

The SFP cooling and demineralizer system does not perform any safety functions. Loss of forced SFP cooling will cause the SFP water temperature to slowly rise. The longest time interval l between SFP cooling system failure and its detection is 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> since the system is inspected once per shift. The failure would be detected sooner if the SFP water temperature reaches the alarm setpoint. If forced cooling cannot be restored, then the SFP water temperature will continue to rise, increasing the evaporation rate and possibly resulting in boiling within The only requirement to assure adequate cooling of the spent fuel is to maintain the water level in the SFP above t5e spent fuel elements. Section 6.3 analyzed the loss of forced cooling to the SFP and determined that sufficient time exists to effect repairs to the cooling system or to establish makeup flow prior to uncovering the spent fuel. Makeup water is available from a

^

variety of sources as described in Section 4.3.1.

l In the event of a design basis seismic event, the systems that were designed to Seismic Category II requirements may not be operable. In this case, sufficient time would be available to align a source of makeup water to maintain water level.

111 COMPONENT COOT ING WATFR SYSTEM The Component Cooling Water System (CCWS), shown in Figure 3.3-2, is a closed cycle system designed to provide a monitored intermediate barrier between components Revision 4 3.3-8 l

i I

L installed in the nitrogen supply lines between the nitrogen sources and de surge tanks. The pressure may also be adjusted manually using the solenoid vu s installed in the nitrogen supply i

lines from the Plant nitrogen storage system. Each tank is equ.gped with two safety relief valves J

)

to prevent overpressurizing the system.

Provisions exist for adding corrosion inhibitor to the system.

Two identical CCWS makeup pumps are installed to furnish makeup water to the system.

Normal makeup water is supplied from the demineralized water storage tank using the

{

demineralizud water transfer pumps.

l For the defueled condition, train independence and automatic isolation of selected loads are not i

required. A single CCWS pump and a single CCWS heat exchanger provide excess heat removal j

capacity for the current heat loads.

i l

1 Piping in the portions of the CCWS providing SFP cooling is seamless carbon steel, fabricated e

and installed in accordance with the requirements of ANSI B.31.1.0, Code for Power Piping.

i 4

3 i

j 11.1.3 Decign Evninstinn i

l The CCWS does not perform any safety functions. Ioss of component cooling water to the SFP f

cooling water heat exchangers will cause the SFP water temperature to slowly rise. If the component cooling water cannot be restored to the heat exchangers, then the SFP water temperamre will contmne to rise, increasing the evaporation rate and possibly resulting in boiling j

within the SFP. The only requirement to assure adequate cooling of the spent fuel is to maintain I

the water level in the SFP above the spent fuel elements. Section 6.3 analyzed the loss of forced i

cooling to the SFP and determined that sufficient time exists to effect repairs to the cooling I

system or to establish makeup flow prior to uncovering the spent fuel. Makeup water is available 1

j from a variety of sources as described in Section 4.3.1.

3.3-11 Revision 3

~

s O

1.14 SERVirF WATFR SYSTEM l

The SWS, shown in Figure 3.3-3, is designed to provide water from the Columbia River to cool l

equipment and to supply water to various systems and equipment. With the reactor permanently defueled, the primary functions of the SWS are reduced to providing cooling water to the l component cooling water heat exchangers and selected room cooler units as well as provide makeup to the spent fuel pool.

3 3.4.I Design Rues The SWS is designed to deliver the minimum required flows of water to equipment assuming a minimum water level of 1.5 feet below MSL in the Columbia River. With the reactor permanently defueled, system design requirements are reduced substantially from the original design bases of the system.

Heat transfer equipment was selected based on a temperature of 75'F, which exceeds the highest recorded Columbia River water temperature.

l The system design includes provisions for inhibiting long-term corrosion and organic fouling of the system water passages.

O Revision 4 3.3-12

f n

l' Loss of the SWS will cause the SFP water temperature to slowly rise due to loss of heat removal l

capability from the SFP cooling water heat exchangers (due to loss of component cooling water cooling). The only requirement to assure adequate cooling of the spent fuel is to maintain the water level in the SFP above the spent fuel elements. Section 6.3 analyzed the loss of forced cooling to the SFP and determined that sufficient time exists to effect repairs to the cooling system or to establish makeup flow from an alternate makeup source prior to uncovering the spent fuel.

1 0

1 315 COMPRFSSFD AIR SYSTFM i

)

The compressed air system provides the Plant compressed air requirements for pneumatic i

instmments and valves and fo*: service air outlets located throughout the Plant which are used for operation of pneumatic tools. The system does not perform any safety functions.

LO The system uses water-cN!ed aftercoolers and compressors. The air receivers are connected to a i

common compressed air Mader which cranects to the air filter unit. The discharge of the air filter unit connects to the air-dryer unit inlet and the service air header. The instrument air header is connected to the air-dryer unit discharge. Each air header supplies branch lines which I

i supply instmment air and service air to the required loads throughout the Plant. The instrument and service air system provides air to the inflatable seals for the SFP gates and to the CCWS air-l l

operated isolation valves (CV-3303, CV-3287, CV-3304, and CV-3288).

i J

i 4

O 3.3-15 Revision 4 1

1 l Loss of instrument air to the CCWS isolation valves would cause them to fail closed causing a loss of forced cooling to the SFP (due to loss of component cooling water to the SFP cooling water heat exchangers). The only requirement to assure adequate cooling of the spent fuel is to maintain the water IcVel in the SFP above the spent fuel elements. Section 6.3 analyzed the loss of forced cooling to the SFP and detennined that sufficient time exists to effect repairs to the cooling system or to establish makeup flow prior to uncovering the spent fuel.

116 RORIr Acin RATCM TANK The boric acid batch tank will normally be used to supply borated water to the SFP. Procedural controls will be used for this process.

11_7 \\f AKETTP WATFR TREATMENT SYSTFNi The Makeup Water Treatment System provides demineralized water of the required quality to g meet Plant needs. Makeup water is processed and then stored in the demineralized water storage tank where it is available to meet Plant needs. The DWST is a source of SFP makeup water.

The water is transferred to the SFP using a demineralized water transfer pump.

1.1 R FOIRPMENT ann FI OOR DRAIN SYSTFM.S The following equipment and floor drainage systems are provided for the Plant:

(1) Diny Radioactive Waste Treatment System (DRWS) drains.

(2) Clean Radioactive Waste Treatment System (CRWS) drains.

(3) Oily waste system.

O Revision 4 3.3-16

f'N 3.4 Ff FCTRIC POWFR G

The electric power system consists of the offsite and onsite power systems.

3.4.1 OFFSITF POWER SYSTEM 3.4 1 1 Deerintinn Four overhead transmission lines transmit power to the Trojan switchyard from switchyards at Allston. Rivergate, and St. Niarys. The four transmission lines, the Trojan switchyard, and the two startup transformers constitute the offsite power supply system.

The offsite power supply is divided into two independent sources. Source No.1 includes startup transformer No.1, the 230-kV bus No.1, and its associated power sources: the Trojan-St. Afarys (PGE) and the Trojan-Allston No.1 (BPA) 230-kV transmission lines. Source No. 2 includes startup transformer No. 2, the 230-kV bus No. 2, and its assochted power sources: the Trojan-Rivergate (PGE) and the Trojan-Allston No. 2 (BPA) 230-kV transmission lines.

The design of the Trojan switchyard and the septreion of the transmission towers allows for two physically independent and redundant offsite powc,. supply combinations:

(1) Trojan-St. Starys and Trojan-Allston No.1, and (2) Trojan Rivergate and Trojan-Allston No. 2.

High speed clearing of faults and selective reclosing assure maximum availability of power.

System stability studies have been made to assure that a sudden system load drop will not adversely affect the Trojan facility or the connected electric system.

The offsite power system does not perform any safety functions.

((

3.4-1

I l

3 4.12 Analytic 9

l 1

l An analysis of the offsite power system shows that it provides reliability and flexibility for maintaining offsite power to the Trojan facility. Loss of power and its effects on maintaining i

SFP cooling is analyzed in Section 3.4.2.2.

l 3J2 ONSITF POWFR SYSTFMS The onsite power system consists of the sources of electric power and their associated distribution l systems in the generating station. Included are the batteries. In the defueled condition, the onsite power systems no longer perform any safety functions.

3.4 2 1 neveri, tinn n

3.4.2.1.1 12.47-kV System The system consists of three 12.47 kV buses, designated H1, H2, and H3. Bus H1 is energized from startup transfonner No. I and bus H2 is energized from startup transformer No. 2. Bus H3 is normally energized from bus H2. Bus H3 may also be energized from the yard loop.

3.4.2.1.2 4.16-kV System The 4.16-kV system is designed to provide electric power for operation of Plant systems and equipment. It consists of four 4.16-kV buses which are normally supplied from the 12.47-kV system through two unit substation transformers.

Unit substation transformer No.1 supplies buses Al and A5 and unit substation transformer No. 2 l supplies buses A2 and A6.

O Revision 4 3.4-2

O)

\\~

l For defueled conditions, train separation is no longer required. The ability to cross-tie buses provides flexibility for maintaining power to station loads.

3.4.2.1.3 480-V System The 480-V system is designed to provide sufficient electric power for operation of Plant loads from load centers and MCC buses. The system consists of load centers, MCCs, loads fed from these load centers and MCCs, interconnecting cables, and associated instrumentation and control circuits.

For defueled conditions, train separation is no longer required. The ability to cross-tie buses provides flexibility for maintaining power to station loads.

3.4.2.1.4 120-V A-C System The 120-V instmment a-c and the preferred instrument a-c systems are designed to provide reliable electric power for control and instrumentation.

i The 120 V instrument a-c system was designed to supply 208/120-V control and instrumentation power for equipment not required for the safe shutdown of the reactor. This system supplies power to the normally open service water isolation valves at the Seismic Category I (original l

design) interface with the Seismic Category II portion of the system. In the defueled condition l

this automatic isolation is no longer needed.

The 120-V preferred instrument a-c system consists of four 120-V bus sections which are.

supplied from 120-V instrument a-c buses. For defueled conditions, the system no longer performs any safety functions.

O i

3.4-3 Revision 4

l 3.4.2.1.5 125-V D C System l

The 125-V d-c system consists of two systems. Each system is comprised of one 125-V banery, two 'sattery chargers, one 125-V d-c control center with two distribution panels and a split bus connected together by a nonautomatic circuit breaker, interconnecting cables, and associated instmmentation and control circuit. The system is arranged so that the battery or any one charger can independently supply the system bus. Power to each 125-V d c system is normally supplied from one battery charger which rectifies 480-V a-c obtained from an associated 480-V a-c MCC.

i For defueled conditions, the system no longer performs any safety functions.

l l 3.1 2 2 untysis A variety of electrical distribution system faults can cause the loss of forced cooling to the SFP.

The only requirement to assure adequate cooling of the spent fuel is to maintain the water level in the SFP above the spent fuel elements. Section 6.3 analyzed the loss of forced cooling to the SFP and determined that sufficient time exists to effect repairs to the cooling system or to establish makeup flow prior to uncovering the spent fuel.

Based on the results of the analysis and the Gexibility of the offsite and onsite electrical distribution system, sufficient time would be available to perform one of the following options:

(1) Restore offsite power and forced SFP cooling.

l (2) Provide alternate source of power to systems reuqired for SFP forced cooling.

l (3) Provide an a-c independent source of makeup water.

G Revision 4 3.4-4

TAM F 1 1-1 j

LOCATIONS OF GAS STORAGE TANKS l

Equip. No.

Service Location Dimensions pi T-118 Compressed Turbine Bldg. Elevation 3-ft dia x 165 A,B,C air receivers 45 ft. outside EDG rooms 8-ft high max between column 51 -55 l

T-151 N bulk gas Roof of Control Bldg.

24-in dia x 2450 i

A,B,C,D, tanks 21-ft long l

E. F l

T-159 Liquid CO, Turbine Bldg. between 4-ft dia x 200 storage tank column 77 - 83, Elevation 10-ft long l

45 ft.

3 T-157 Air Main steam support 183 in each 125 A.B.C.D accumulator stmeture. Elevation 64 ft.

T-125 Hydro-Turbine Bldg. south end, 11-ft dia x 125 pneumatic Elevation 45 ft., between 19-ft long pressure column U and T accumulator (air)

T-204 A, B CCWS surge Elevation 77 ft., column 7-ft dia x 150 tank (N )

line E and 61, between 8-ft 3-in high 2

Reactor and Auxilary Building

~

lO Revision 4 1

i TA M F 3 1 -4 ANALYZED SFP LOAD DROPS AND hilSSILES I

LOAD DROPS Niax.

hiax.

D Drop Impact Impact Item We t

n.) ght(i Energy Surface Hei No.

Item Description (I

(in.-lbs)

(in.)

1 Spent fuel assembly 1,624 12 19,488 8.42 x 8.42 with reactor control rod 2

Spent fuel assembly 356 172 61,200 9.0 x 9.0 handling tool 3

Spent fuel assembly 1,976 12 23,700 8.42 x 8.42 with handling tool 4

BPRA handling tool 800 148 118.400 18.0 x 18.0 5

Thimble plug removal 290 192 55,700 8.69 x 8.69 tool gl 6

Fuel assembly channel 350 254 88,900 8.42 x 8.42 spacing tool 7

Radiation specimen 600 12 7,200 8.42 x 8.42 transfer basket 8

New fuel tool 80 480 38.400 9.0 x 9.0 9

Electric chain hoist 90 530 47.700 8 diameter 10 Portable RCCA change 900 148 133,200 8.42 x 8.42 tool 11 hiiscellaneous hand 500 300 150,000 36 x 48 tooling / portable vacuum system TORNADO hilSSILES Vertical Velocity at SFP Surface Dry (W)eight Item No.

Item Description Ib (mph) 1 4-in. x 4-in. x 12-ft long wood plank 108 140 0

2 3 in. diameter x 10-ft long steel pipe 76 52.5

s i

tam F 1 <-1 Sheet 1 of 38 i

l I-LIST OF PERTINENT REGULATORY GUIDES FOR DEFUELED CONDITION i

Revision and Compliance Status Regularnrv Gnia, 1.8 - Personnel Selection and Training (5/77), Rev.1-R Cnmnlinnee Stame i

i Comply with exception.

i j

-(a)

Technical Specifications require that each member of the facility staff shall meet or exceed the minimum qualifications of ANSI N18.1-1971 except for the Radiation 1

j Protection Manager, who shall meet or exceed the qualifications of Regulatory Guide 1.8, April 1987, and Independent Safety Reviewers., who shall have five years of l

s I )

professional level experience and either a Bachelor's Degree in Engineering or the l

i Physical Sciences or equivalent in accordance with ANSI /ANS-3.1-1981.

l.

i (b)

The qualification requirements of ANS 3.1-1981 are used as a goal for the Technician with one exception. Specifically the Technician requirements given in ANSI N18.1-1971 (2-year working experience and an optional 1 year of related technical training) will be used as a muumum requirement in lieu of the 3 years experience required for

]

ANS 3.1-1981.

i (c)

Paragraph 4.2.2 of ANSI N18.1-1971 requires there be an operations maiager who holds a Senior Reactor Operator (SRO) license. Paragraphs 4.3.1 and 4.5.1 discuss i

supervisors and operators required to have NRC licenses. Section 5.2 discusses training of candidates for NRC exammations. Paragraph 5.5.1 recommends retraining include startup and shutdown procedures and emergency shutdown systems. In lieu of I

. the above, no personnel are required to hold NRC licenses, and Certified Fuel Handler (CFH) training will only be given on subjects applicable to the permanently defueled i

mode. In addition CFH training need only maintain proficiency in allowed activities.

1 i

t i O Revision 3 4m-

-.r.,

TABLE 3.5-1 Sheet 2 of 38 Regilntnry Guide 1.13 - Fuel Storage Facility Design Basis (3/71), Rev. O cnmnt;2nce st,nic Comply with exception.

i l A seismic Category I makeup system is not provided. The reduced decay heat load after 3 %

l years since the reactor was defueled allows over 10 days with no makeup or cooling before manual actions are required to prevent fuel damage. Therefore, adequate time is available to operate or restore one of the diverse non-seismic makeup sources.

Regilatnry Guide 1.21 - Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants (6/74), Rev.1 comnliance stame Comply with exception.

The use of a meteorological tower for real time measurement of meteorological conditions may not be used. Worst case meteorological values, based on previous evaluations, will be used to conservatively estimate releases when the meteorological tower is not used.

Regi12tnrv Guia, 1.24 - Assumptions Used for Evaluating the Potential Radiological Consequences of a Pressurized Water Reactor Gas Storage Tank Failure (3/72), Rev. O Cnmnliance Statut Comply.

Revision 4

1 J

4

!O TABLE 3.5-1 Sheet 9 of 38 quality related materials, parts, and components only when specific protection measures are required. In lieu of the detailed requirements of ANSI N45.2.2-1972, quality-related items will receive a thorough engineering evaluation to assure that adequate protective measures are specified for packaging, shipping, receiving, storage, and -

handling of items for nuclear power plants. These protective measures will be consistent with standard / commercial engineering practices and manufacturers' recommendations.

(c)

Marking may be applied to bare austenitic stainless steel and nickel alloy metal surfaces provided that it has been established that the marking is not deleterious to the item rather than as stated in Paragraph A3.9 of ANSI N45.2.2. Proper chemical controls I

.will be employed to ensure there is no adverse metallurgical impact on the steel or nickel alloy. This position has been adopted in the document ASME NQA-2, Addenda 2a.

Remilarnry Giiide 1.39 - Housekeeping Requirements for Water-Cooled Nuclear Power Plants (9/77), Rev. 2 Cnmnliance Comply with exception.

l l

Regulatory Guide 1.39 endorses the application of the recommendations of l

ANSI Standard N45.2.3, " Housekeeping During the Construction Phase of Nuclear Power l

Plants." The cleanliness and housekeeping standards established in ANSI Standard N45.2.3 l

)

are designed to control work activities, conditions, and environments that can affect the quality l

of important parts of a nuclear power plant. These parts include structures, systems, or l

components whose satisfactory performance is required for the plant to operate reliably, to l

prevent accidents that cause risk to the health and safety of the public, or to mitigate the l

consequences of such accidents if they were to occur. Specifically, the last paragraph of I

Section 2.1, " Planning," requires a written record of the entry and exit of material be l

established and maintained for Zone III cleanliness areas. In addition, the second paragraph of l

Section 3.2, " Control of Facility " states that appropriate control measures shall be provided l

through the utilization of such items as log books and tethered tools.

l l

In that the plant no longer operates and has a relatively long time available to respond to, and l

mitigate the consequences of, any accidents postulated in this DSAR, strict application of the l

requirements of ANSI N45.2.3 is no longer necessary. Specifically, the use of a log for l

control of material above the spent fuel pool will no longer be required, but the option for its l

Revision 4

O TABLE 3.5-1 Sheet 10 of 38 l use will not be precluded. If a log for control of material is not used, a visual inspection of l the tops of spent fuel assemblies will be performed.

Repilarn7 Gnide 1.58 - Qualification of Nuclear Power Plant Inspection, Examination and Testing Personnel (9/80), Rev.1 Withdmwn Cnmnliance Comply with exception.

Position C.2 requires certification of non-destructive examination (NDE) personnel per SNT-TC-1 A-1975. The NDE personnel are certified per SNT-TC-1 A-1984 at the Trojan Facility.

Remilarnrv. Guide 1.59 - Design Basis Floods for Nuclear Power Plants (S/77), Rev. 2 Cnmnliance Comply with exception.

During the design phase of Trojan, pertinent regulations dealing with floods were 10 CFR 100.1 and General Design Criterion 2. The probable maximum flood (PMF) for Trojan was determined prior to the issuance of this Regulatory Guide and has been reviewed and approved by the NRC. As stated in this Regulatory Guide, previously reviewed and approved detailed PMF analysis at specific sites will continue to be acceptable.

Regninen7 Guide 1.60 - Design Response Spectra for Seismic Design of Nuclear Power Plants (12/73), Rev.1 Cnmnliance Comply with exception.

Design response spectra for the OBE and SSE were derived and used in the seismic ~ analysis Revision 4

~

l l

j V(~)

TABLE 3.5-1 Sheet 11 of 38 l

l t

1 and design of the Trojan Nuclear Plant prior to issuance of this Regulatory Guide. The methods used in the original derivation are described in FSAR Section 3.7.1 and have been reviewed and approved by the NRC. DSAR Section 3.1.6 summarizes the seismic design parameters.

l Regnf arnry GnMe 1

l 1.61 - Damping Values for Seismic Design of Nuclear Power Plants (10/73), Rev. O cnmnnwe Comply with exception.

(a)

Table 1 of this Regulatory Guide specifies a damping value from 1 to 3 for piping systems (dependent upon pipe diameter and type of earthquake). PGE used a critical damping value of 0.5 percent in the dynamic analysis of vital piping systems and equipment. Seismic analysis of Trojan piping systems using a damping value of 0.5 l

,3 (v) percent is mote conservative than the criteria specified by this Regulatory Guide.

(b)

Table 1 of this Regulatory Guide specifies a damping value of 4 and 7 percent for an OBE and SSE. respectively, for reinforced concrete structures. PGE used critical damping values of 2 and 5 percent for the OBE and SSE, respectively. Analysis of Trojan's Category I structures employing damping values of 2 and i

5 percent is more conservative than the criteria specified by this Regulatory Guide.

(c)

Principle constituents of the Control, Auxiliary, and Fuel Building complex are reinforced concrete, reinforced grouted masonry, and a combination of the two. Table I of this Regulatory Guide does not specify damping values for such heterogeneous I

structures. However, the complex's stmetural materials can be conservatively assumed analogous to reinforced concrete for damping consideradons. Damping values of 2 and 5 percent were used for an OBE and SSE, respectively, and are adequate.

(d)

Table 1 of the Regulatory Guide specifies damping values of 2 to 3 percent for equipment,2 to 4 percent for welded structures, and 4 to 7 percent for bolted structures. For stmetures and equipment, and supports for other than vital piping l

systems, PGE used damping values higher than 0.5 percent where justified. A maximum of 2 percent for OBE load combinations and 5 percent for SSE Icad combinations was used by PGE in accordance with the original design approach.

Alternatively, some damping ratios are based on calculated stress levels as prcvided in 1

I Revision 4 l

l t

l l

TABLE 3.5-1 Sheet 12 of 38 DSAR Table 3.1-5. The use of 2 percent for OBE and 5 percent for SSE, where justified, or damping ratios based on stress levels as provided in DSAR Table 3.1-5 meets the intent of the Regulatory Guide and is adequate.

Regularnrv Guide i

1.64 - Quality Assurance Requirements for the Design of Nuclear Power Plants (4/76), Rev. 2 WithdrnYn enmnliance Comply with exception.

Under certain conditions, the Manager, Engineering / Licensing may perform design verification provided-(a)

This manager is the only technically qualified individual or has special technical gl expertise which would allow him to perform a more thorough design verification.

l (b)

The need is individually documented and approved in advance by the General Manager, l

Trojan Plant.

(c)

Quality Department audits cover frequency and effectiveness of use of the Manager, Engineering / Licensing as a design verifier to guard against abuse.

This position is consistent with NUREG-0800.

Reguintnrv Guide 1.74 - Quality Assurance Terms and Definitions (2/74), Rev. 0 Withdr2wn Cnmnlinnee Comply with exception.

The terms and definitions of ANSI N45.2 daughter standards that are not in agreement with ANSI N45.2.10 will be as used in the daughter standard. In addition, the definitions of Permanent (Lifetime) Records and Nonpermanent Records have been modified for clarity in accordance with the definition in the QA Program Glossary. The definition of " repair" in Revision 4

_.m.

4 5

d TABLE 3.5-1 Sheet 13 of 38 v

ANSI N45.2.10 is replaced by " modify", because the term " repair" as used in various sections of de ASME Boiler and Pressure Vessel Code has a different meaning. The term " modify" is used to avoid confusion.

Reaularnry Guide 1.76 - Design Basis Tornado for Nuclear Power Plants (4/74), Rev. O Campli mce Comply with exception.

Design. constmetion, and licensing activities for the Trojan Nuclear Plant were in an advanced stage prior to issuance of this Regulatory Guide. The recommendations of this Regulatory Guide were therefore not used as a basis for characterizing a design basis tornado. For the Trojan Nuclear Plant, criteria to evaluate safety-related structures for potential effects of tomados were developed pursuant to AEC General Design Criterion 2. All Plant structures containing systems needed to achieve and maintain safe j

shutdown were determined to be capable of resisting 200-mph tornado loads and a pressure differential of 1.5-psi bursting pressure applied at 1 psi /sec Many of these structures were evaluated to be further capable of resisting 300-mph tornado loads and a pressure differential of 3-psi bursting pressure at 1 psi /sec. Draft Standard ANS 2.3 specifies a 200-mph tornado 4

4 at a probability of 10 yr for sites in Trojan's region. He 200-mph and 300-mph tornado maximum wind speed criteria are conservative with respect to the wind speed associated with the maximum tornado that could reasonably be hypothesized for the site. These criteria and methods have been reviewed and approved by the NRC.

Reaulsenrv Guide 1.78 - Assumptions for Evaluating the Habitability of a Nuclear Power Plant Control Room During a Postulated Hazardous Chemical Release (6/74), Rev. O rnmnliance Not applicable.

Analysis shows that Control Room habitability is not a concern in the defueled configuration.

See the discussion in Section 3.3.12 of the DSAR.

O Revision 4

TABLE 3.5-1 Sheet 14 of 38 Regiarnrv Guide 1.88 - Collection, Storage, and Maintenance of Nuclear Power Plant Quality Assurance Records (10/76), Rev. 2 Witharnwn Cnmnliance Comply with exception.

(a)

The QA records will be stored in a facility with a minimum 2-hour fire rating in accordance with ANSI N45.2.91979, or as NFPA Class 1 records in a Class B (350-2 hours) container in accordance with NFPA 232-1975. ANSI N45.2.9-1979 has superseded ANSI N45.2.9-1974 and requires a minimum fire rating of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> for facilities in which QA records are stored. NFPA 232-1975 is endorsed in this Guide as an acceptable altemative to the tire protection provisions listed in Subdivision 5.6 of ANSI N45.2.9-1974.

(b)

The retention requirements of ANSI N45.2.9-1979 will be followed in lieu of the h

requirements in ANSI N45.2.9-1974. The retention requirements of ANSI N45.2.9-1979 appropriately reference the requirements of the regulatory agencies having jurisdiction over these records.

l l (c)

Trojan will use optical storage as allowed by NRC Generic Letter 88-18. " Plant Record l

Storage on Optical Disks."

Repibrnry cuide 1.91 - Evaluations of Explosions Postulated to Occur on Transportation Routes Near Nuclear Power Plants (2/78), Rev.1 Cnmnlinnce Comply with exception.

An exception is taken to the value of 1 psi for the maximum permissible overpressure generated by the atmospheric shock from an explosion. The analysis given in DSAR Section 2.2.3.1 calculated the probability of occurrence of a shock wave with a 2.2-psi overpressure. Test structures similar to the safety-related structures at Trojan have demonstrated that overpressures of 5 psi can be endured without any significant damage to h

Resision 4

TABLE 3.5-1 Sheet 15 of 38 i

l these structures. Furthermore, it is noted that these stmetures are designed to withstand pressure differentials of a least 3 psi due to tornado effects. For credible accidents, however, l

the maximum permissible overpressure value used in the analyses of Trojan is 2.2 psi.

Regibrnry Guide 1.92 - Combining Modal Responses and Spatial Components in Seismic Response Analysis (2/76), Rev.1 Comnliance Comply with exception.

Seismic analysis of structures, systems and components in the Trojan Nuclear Plant were i

completed prior to the issuance of this Regulatory Guide. The methods of combining modal responses and spatial components as recommended by this Regulatory Guide are technically sound. For modifications to the Trojan Nuclear Plant and for analysis of existing stmetures and components, either the square root sum of the squares method or the methods of modal

(

and spatial combination recommended by this Regulatory Guide may be used at the option of the engineer performing the analysis.

However, modal responses were combined in accordance with this Regulatory Guide for the modification of the Control, Auxiliary and Fuel Building complex, with one exception.

Contrary to Position C.2 of this Regulatory Guide, the combination of effects due to three spatial components of an earthquake was not performed. Rather, a co-directional response value was determined. That value was the maximum value obtained by adding the response due to the vertical earthquake with the larger value of co-directional response due to one of the two horizontal earthquakes by the absolute sum method.

Regihrnrv Guide 1.94 - Quality Assurance Requirements for Installation, Inspection, and Testing of Stmetural Concrete and Stmetural Steel During the Construction Phase of Nuclear Power Plants (4/76),

Rev.1

("'nmnlin nce l

l Comply O

t Revision 4

TABLE 3.5-1 Sheet 16 of 38 w

Reguintnrv Guide 1.102 - Flood Protection for Nuclear Power Plants (9/76), Rev.1 Comnlinnee Comply with exception.

Construction of Trojan was completed prior to the issuance of this Regulatory Guide. De flood design criteria and bases for floods used for Trojan are described in DSAR Sections 2.4 and 3.1.4. The need for shutdown procedures and communications per Position C.2 does not apply to a permanently defueled facility that does not require operator action to maintain fuel integrity for several days.

Remilntnry Gnide l

1.105 - Instmment Setpoints (11/76), Rev. I comnliance Comply with exception.

Trojan does not conform to the regulatory position concerning the design verification of these instruments as part of the instrument qualification program recommended in Regulatory Guide 1.89. Trojan's serpoints meet the intent of this Regulatory Guide but not its specific format.

Construction of the Trojan Nuclear Plant was completed prior to the implementation date of this Regulatory Guide. The method of selection of serpoints was previously approved by the NRC.

O Revision 3

i Bm a.

'=~YilWR5%$y.,d-~_a E,d_ 4 / w__, e._

t l

p=

a m

E4.,I A E W ll.,c,===-

g i

e.ns m i.=4

, dE, l

i Iv- ; 1 l

I l

c e

.l L

s i

- h D

S 2

0,,

S.

,/7 i

i 1..

i J W-s.

m, g -

-i m-_,

m i

I.

Q

~W.

Ce

.M

p4 wl t $1!L R.ss ~,. W-E w--

e r

6:-

enc 7a -:

y p y-,

~,

l "3

1 STME

g. 1:ii;-" t g w~y
  • . c,
g..is I

c_,-

.s

.~

e s

BJ

~~

e-e e

e-e -.

. ; =p

. - a n c-e e..y-.

r l _.

!Np i!

e,l i

M. I.

l

.....'...,4 i

1:

l D

e...e.

9 9

9 l'

..J s"'f I J.6

- m r;:9 e gpre: g,!"e bp".mm%.c u_

x.,,.,

e

~

5*1.i'1.; f:a:s.

T i

i. ;r

.d E.. f". r1::: =I.

-ma *..

-.a.w'rf-Fi I li

-t v

.e -

c

. dIlJ

-d RS. I il _

' 'ill '

c-l t., p -

-a y _

,......a.

a,p Wp i

h so l

5-r.n_,.,m.,

i

.-- %- _+, _.q e,q __m s

u e.

[ r.m;uic_N

.N.

...x., -._

v-

'7. :....!.'. Er <' W,,!,

.;cA :'-- ;@m 2 ': ":::::: ::

'.2'.u? =

.,:; w..____ ;!'. 3 L._. ; !*,'il,E.h..

2 i.J r, --. '.. s l

l

~

e l

~'

~di / '?"f.

~;

".u.;,,,.

w,.

gi f-

-C-*,.

C ' 13','.8' )b

~

i ~ ~, ;

h*

"'7 p-

.y _.

~.,

. _~

i

+

8-(

$8 226 M<

  • E c

__: sa...*

  • e

{s_,

m i.

.e.s

..w.

l A

m.. *.

T'_

8'

  • 1 1

{

(

8 i

7 l

6 i

l

l 0

i

  • ]

i oc!GTEC l

t APERTURE CARD gz Also Available on Aperture Card i

t

/ /.

i Ti

,,' i- ~

=

l

\\

i

.I

- =....

8

... /.

l 431

~~

J

/

l l'

l

,/ l

/

dj / e

./

i 6

AJ blzof0047 Figure 3.2-15 Equipment Location, Reactor and Auxiliary Buildings

- Plan Below Ground Floor NOTE: HistoricalInformation Only Revision 4 5

1 4

i 8

I

~~

r H

=N

+

.s

e ri s i

z.

o.

~

i.

. #, #':4 ;j

. n!.: f >

.. Tf r (%

.m

  • y G'A.

/is l

f i v4 (p. ;

. si l'

Ng

'(

t p;lt;l e.

W c

x I

a

.i e

i a

g

, !o r

i r

.e a "

===== m

.e.r sica.msu

~

%.g 6-. b.

--e*

[, j C__;w.; ^a :-

i t.

.l J f

.- 1. !1.x-a l

M!

..ee %

pl m

r-P

- -"_]-%

~

.m u

~ y. ; 7 _"-"'" q j ' ~? *

.a ~

D i

..... ~ -

q..y

_~

t F

waz,,,

g, y;;;..a.-

psi gg,.; :,~,,,.,

h

. u

-.- u ~..

!.r e-i s_w = ny #_ A. / -e r

l 'J

- ll'le--

1: ' !"

'v

- e I,LL

.j,,=.ch, ',,..

- h..

_=== -

O'T h i

i i ;...

_s s

i.._.','

=

i

.".fL#' i! !

. I 7

,, 3..

l

~.l. -l-y-i

}..; j, j e._,__
q,"" -"2

~

l M '.E.'4

  • /

u g

g

} {.

, % * '- 1er*3r.!

i emeses e E

.l I,l*22L,' 2::' f 4-I d '79-*'

@.,i

)0 r__

(

-J

-_.d n

i I ;g s;r.v e i I:

l

  • y l

m

}#7 a.

i ju j

i r-__ I ' ~, w-T !"

F c

J

... = = -

r

=

i ~<

1 q,.._,

e ~_q:

a i

i 11

~~

i i

i 1

. 41 se ~..a n

l Y.,,.

,.,e t, n

D

(%e. s.

- eg

.c-

1... macss,_,,.

m.

d' 9

.e

,l

  • mae f c:n.. e i

N

,5 I

i ir d

.W

- M:::

h.2sp e.-A -

r

-;l*b a

.=

gr-.,.:.v. 2i.- - - '

a t.g:..% 1 l

=:

'3 I

C i

I g ll

-l

'u t:s t 22'.

"-- J+ y g

g,'_-

ss,....

' 3.f y

.g p-ear.

s s

  • -***.O..

I*A$e -

-,}-

~'

\\

j-o u c.

.<.: s a

6

-4

-+:

  • W,@f3 *i/f

~ f..

g

,a

~. r,

v

,_M

..a ne 4.

.w. s.

8 4

==-

9%

.d s

  • )

l..~.

r

,q. p

..,...,,.u.....-,

/

C A

8 1

7 1

6 i-

i I

ANSTEC

~e v

APERTURE ew yo

<2

i - =.r.:

e.

CARD

... m m.3g.F.-

tj g,

l e,m"., 3 t >

,y

-- - c.1 :@=

g_-

1. "

L i}i

-Q* U%t j = %.

y?

-x:.

Also Available on e

t

} 8,; L '-

h:ra-*

1:e Mn-;p m-13_-

l w.5 i.

' Aperture Card gj,

r.

====, q.m y -

.m I

% -7,.;

l' a

~

i.

t.

.= - '*,a :. J j

.m. g m,, +,

~

o r

i 7q..

_ a x.:. -

r._

_... 2 ;r;,,.,,

r 2

r

,g.

c N

s,a l

4 l

f

- f

%+9' a:as.

s t

t i-i l

l

".1 1W

.- i i W.

e-,

,o i l l

l ll l

li %

' C 5j i.

U!

~ ~. '. ".

. h 4. *w r

^

u.. r l II I

l.

,t*

,il n

i r4

~.3 I;

h i

l}

I I

I t

D t

~

[h,_f '

s t

-s f..

. [

!L

,,~ m.,

N i

I s

, '., _Mg

?

,....I~l. -

.f

-s

,I r-J.

l ( l t_,.

-,-(

l

c L

+/

s...,j

.N

,s.m-o

%./

x'N,

i N

s

.m b-6.~_.

_-m.u.r--

.%w l

.pa-w H

3 s.x s s

3,

- y,.

u s

,x

-.-..y ;...s,;; w

._.%_.~.'".'.".i[---"'.*.'.

'/

b -././ {...?,.~,..gi err U r..,.,,. m 3IJi

.w

.. s n.

s a a

y

+

N

..,,r-s, s

x..

\\\\.

,,N

-M, A p.<>

/ ;.,j., _

C.-

-rn

.l..

-r.N,.

,M,2 '\\

-_3

--KC.

-~,'~ '/

e

/

f.

,,/.,

. _c __,. i_ i,

c.a s,

. /

, q. _. T._,.g.? L. J, *~. ' N

..& c

,. 7,,e,g'.

... -.7. g,..; q ;

p.

'K I

-""'*f.i# s.

_ A,&... s-.. _ -.... _.9,. g = ~ \\. ;,.

f

.m y

c

, n_/ z.,- -

s.

s

~.%'

G .

s

.V.

3 4

/.

,.. c'y. --

.'., T.,,s.{,(7;';'.. a

',N.~ \\ \\.

Fi.

's St a i e-J

.ej

- s

~n Js.. vm..

7,o _

s.,,-- '.,

q!aa 6

p..;.1

-.2k.

"N I

ti

  • .=.a.

):..,ur>..~ys--

.I M_.

m_

-m.:

,- - n

-- = y.

y.-

L-.

,;w..

.~

&_j ' % -. p ~ 5 1 '~ ll.

?.m 3m

? ;.y '

x.kA t-N i G

=.\\., -.,~".a $

& W S '.

\\

a 7 _f,

<' x r..n.. u.

r.

,,e n

  • * * '. ~:~ m'. seg'c ->.. '-
-s

\\ " ~ 'C'** ; -j.',.

7,.

.c

=

i W*'.2.,, N'N '. -

,O/,/

\\

c.. & : = m J. - i

-= y..g f/

?

\\

\\

/ L '.. -..c- = r.

O- -

/

~.,

s.

/

g

- ~...

\\

.g s

s

.J' f,

,, ' -~ QyQgQ~ ....,.' A ' N^ N - 14 m - s s ,,m,. a

. ',e

.u ^- r;::x N._ y ..;g' r,-..- 2 _m [ _y ~. --.~ x- ' _ _;r ;.. pe i x ,,s x x' u, -:u~-s'~ :;3 i== 9. x

3..'.;. y x*nx e i.=

1 a .,.e. 2 r .m...... __cr 47 _ 7___g_7_ --.-.. NOTE. Historical Information Only ..w_j Revision 4 3 '9 ~ 2....,,., ,_.m ? '" W _r Figure 3.216 Equipment Location, Reactor and Auxiliary ..m .e i Buildings - Plan Operating Floor. ~ Elevation 45' 5 1 4 1 3 1 2 i I c _._ -___s

b BT i hh(l,/ -/ m fm W....P..r._, >t l2 ._e l -o ~ w o J \\ m p, p

  • T Y

a j l ( - s, , ag;,, G E l l* u\\ ! "& W r4 4... s e. 4., s (j V M*-- 3 -; i V+ .-i 3 j . Ca:j:,.,, my, w's t - e i / a e . ss.et ; Nsa.7 i T; c +w g= z e i AllAVN3 ' ' /,'g g h\\1/4W!Lld L /// / /. ', A- _I_ M //d e L.lQ l,6 3, % ' F '<'-=== e'=== p lr.:fY E m, Vb -$'*{ f .2" "*."*w p g@ 3*" tl 2-NUkP$h"h;=Mih)$ e d2 !I b.I Il'y c.w.e I~ 4 '*3 k..,) [ ~

  • j b Nf

- lf? m N 'f ':ll = ' I ; j,,, I; @g ! /*'*S (/r-71l @/ f o E g lL, k g :n 31. - i d ,,,,,,,a, hb d' pa. .h I l, l ,w \\ + l '* f,, O "P - e s- ' ; i f P 'd , /o. ,0 j y wr ~ g 1. l'GJ .E .i ~ \\ Y"". o g. = p .1 ,f d***.!. .i: h o ws h'I /j. n ,Qf k { p s' f'i 5 G b u4 .n-t

(

y IfM ' d A<;.5 ' ***'.e ik

  • -""*l j

b t _ a _.4 V1 hj U + Tfk e iip. i! =. h. [ L: mi d [. lA ' 1*'.". [: - e..... e ~ ! i = O,, N 1., ' r--- 'h

91..s, - -

- A% .-.,..--r... . a h_ar* ***'a=4 ~ -

  • e.t..a.ae cm.

,,rg, aume l ' ' ' ' ~ 5 es.ves essa 3 B !6 6 j "'*"**a ~

l. $7 M.

i i.*

  • El w

.,I' h t '~~' F T .1 1 E .e.,s....v... re.. e .- o : (N, "U A 8 l 7 l 6 !) o

} e AA e + +

== ux~ i it -.-. u. t u a

===-A- ,,,,.e.-- ,a - ,s-a, _a i. 4 e i rh j a c,i,_ w-. v .-... L RTURE s+-

?

_.c,. m y c m:. -_a ,_g" 1 >f =,. p i m. CARD i v J'== -l d m-i yso Available on s -- = : j ,1 i ~~ 3 f < L * =, J-APefture Card q{ l'+ --- y g g 'h. n-h l 'I ~ d/ ;'[ b, -gi

l 1

~ D 1 i

"4 i, A

'i l 1 JE ' 6 g-g j

':~4 I

'y~ L h } M'W-l*~~ h sl p.l4 /. h.-

)

,, c"" .on-. M

  • !W 7 Er p

s '\\'. -*^ "^' R ^" E

  • 3 L_a bm.

..a y 4' m i s ~1 ! w.- ~.. G~r F, . c ~ ~N. - , ' ' " " " Q.& y.,/ -r=4 y2pg; l, /~% R _1 * %:.a Ni s s/ o.*, ~, ase s es V 3 g,. _ m i.-

      • 8.

,g.,,f, '(pl/ \\ l p g g-

i i%.*i

,i f, p..j; a t ~ % y, ... =in s &' g*.,/ p ...~.I r g 0g !==l ' 'O ff'N q Q/h . N, '\\\\ 7 N , m: o n r-N, 9 i . ' y.2.= . - e \\ _. n / v '} Q. % N-.h l ^^ v. e. ~) . I &.. Ij p O1; ) ~y \\,~ . ] I:' ' #f 'is W.I ; n

L.....

a t,,4 .~I i,,,,,. . g .w p g \\ 1 ,p g i ,. T~",7,/ h1%aNe^ / 0 lj; _ hUi m s

  • -*~*i
O k'

' - () I k1 w o\\ M d l>l PG.Fs - / '4

s s

/ gegg,, g / ',.*<C- *r ,R s .t. s ,'.7**.,,' C W' O. s pi"1 M-w \\ N '.. 'y q] &.E,n #2W e' !j d \\ s f,b.< H =.' ".%,. : / /,/ /,<' 2, ..4 .x i I: s s -q agg.;.,,,4 x \\. _=a +. i ' y-. ' 'N x - m _ ' l.e .l t>,. m y / mJ .3 u. ~,* r 3p =;;; m....__ 1 8 _Y [ *i )!l h. s-G- x ds 1 i --..,) ., 2 i s..._, ew, l"Q, ;j a __pd' l m.- Figure 3.2-d Equipment Location, Reactor and -v -- 7 ="- &_] Auxiliary Buildings - Plan Elevation o a- +.....-_e,_._,. TlG.. e. -..s '= y + ~ .g g a O 9(j/20500 S S NOTE: HistoricalInformation Only Revision 4 i 3 2 i 1

1 h. 4h. (D. .B.".92@ v ... e. i ~ H T-- g i m. l [< \\ 4 .u = rs .f ifl!

g~-9 --k

_1. D i l'~h l.. $k; /*K W 1 h n

e.,6 W IY i

d li 0 ' /*\\ : 1 I 'i 5 Wb m sw -_ i. a i;; /g ,-- ~ *4

  • 7_W t #4 ctL c17 g, q.-

,,x 1 y" ' - ~ ; 6)'N..nw:e/,? I ; ' l ' D5 yI/ s t

  • i m

m = u. I... .I 6 3 ' " " = = l fi, _g" /e. s.* t s g=_q_ a, ~. _._v q '- 7- / v,, c . 3. j. 1 ,, w ,F ..1 '#x==m= t - s/. I~ g

t. l n

e g ,r - F. r. f l. ., =, -2 2 f. t g .P m. .. t. C. /

    • '.'?

3 t l r (, f & l

l/. I ;.y l.
4
r-'s E

b ~) \\ y;"" V) / ir. i#'N" 1 W= J X- .. - gi M t ..Y. l .i h ~ @h i U ~

jY

=i -.a i .j i i s...i Al; i J J s --%.T, if te g-W f$g [g O&;tsfa$ ii i i- g' 7 '.. ! d, ame=.w ~ .I g ]N

t. tl.

d. lw.g 3 l ~ f. D "'T ;*. , ' . -Fi y,; g Gp aM a g. r. 1 .3 A,a i 5:e w =.yQ ,, j:s sD ri.!, - i l j j' N j [d -Y E N j i 1 ,Y gy. = '3 T/ < ~~21,. 3.2f C 1 l u. ,n. i va riK:1. m,,- i .@ s v, -11 i .= , p - -, -~ l fk I y .;,g a (~ l w -i i a u --.3 8 5%__ s. 59--- Ij,n-,*.=m.r .c c. i .n i t -M i ./ i + 8 [. s,.l. '-[ 4 t c; / ~. g%g. 9 a=i- " -- - H .. ~ ~ " "...... - ~ ~ Bd m 6%#et up A 8 l 7 l 6 1 +-

e. 4 ... e-. I k 'I 1 . o ,.s.. 4_,_ tw, 9 -w a ---r =3 49il , er o 'j ANSTEC 7~ .= p j ~ APERTURE r l 4-W .-.J =m! CARD m. Wg[g i 5 [! i j T PG j; Also Available on Aperture Card i. ir I I II $ ' l$ }, {' $yj 'U l 'w- /%.. L2

L

\\\\ 'd i - m

=,
t i.

Ei =h. +' ? y sf, ;,,. %f .. x ?i .-} ^ll Yg h. , / am".T.. 7 E / j t. c sr m [ 4** /\\ ~', - wr y / sj g g -v w w - q, f <\\ a NN : ~ k, E\\ [TW k -- QJ/l m \\h)gY' $ r I i ? Q 4 8 2 i d '".i,d..'f :l / de... i 1 3 Cg,,,,,. JTi. .,_.y ja ; @O . & l [....p. ,a w c, s l 1s / .g \\ f ...,A, s ri' , l- .\\ /T. 's v,

~

.\\ (N Q* \\ /

  • /s i

A x / -~ /,. -.. W )y h T'gM TCg 1.T1 'N m N -Q:.**z }.. f 'k.

f.
:,317

/ ]% l \\ 'NQ )W"]~. '..-- ~g,.U// ( 7- - a m.r r/ p-.e.% 'N. ./. s /.w ,7 jom s lkN Nh ~{%d l:ig J"h. '7 NOTE: HistoricalInformation Only / i. W - -~- i, Q,{rf,.':::- Revision 4 m xx t -m G .h $ Y=sY, a u >.. A ' e -. 2 r e ~o b~- h ._h;,'.Cf.If[p/2C[dC 2- ~ s9 -Ce M ' ".. 'l o m

a =
9[ p,-

.li l !!.l -~~ "---- Figure 3.2-18 Equipment Location, -r-- A _I i i -r.-...--=..- u_ _.v_ w !!:c=. L Reactor and Auxiliary p a g, a. p,, e., I a .-._-_s., i d 9 Buildings - Plan Elevation 77' 5 l 4 1 3 l 2 j 1 gm _____a

ab ,,se 9 TM g..mm

== t a[ saiah md7 H WY -DR

  1. p l L--uu

, _ L., ,'sese g _ gym, i r. L j, .4. _- p,%../ o L. _ dor q [_.__, @) 'C 4 s .dy '.(- -< * ~ " 'l ]C,- l.*.'.*., l )ype y^7 '..' ' " i^ 7 M -' g L t ~ O ._ Cri.. Ck iS ) F17 g "-: ( \\ 1 .a C , "! x > - J'== l r.:ST={ ~ '-'-w]$- g.: 2 i l pm l =yl =iq

l,,

.l l

m. y.

t-,~. l i ce.- - g_.g. ~ = ! 'd' s-w ': ,,g 3 Wa,; ((!,L&, i i ., ~ ~ ) ! y' 1l E s as "#~ G s'--[ g ' EE 'lliM'atl $8- ;::r F 1 I' F l $y _- E kll} g iY , i lir-H et =- i e. 'Gt sim~n 4 kyW h-~U $ d-Gu.T i S Ti e, a j

a. w e_,w e..

_g ~ R, f e r i; i x #s.. - I I h. 'tfMa f h. f 'g %,36-l.d 1 l e eM._. 1 Ce -yL a q i,(; l iii e =~ 3 , s1 o L ,/ t.3 -h[a - f $f 'L ~ \\ 0% l' \\. - b '~~'*I lys }k. m -u f e - =j l \\ m -~~~ f . :l__ w I r.1 ,, Q. [ E -~ E -g ln' y c -A t e __. ~fy I R~~ ll i! ho,, _f l si_. %r ip. i_ _m

' (

B is = i,, p WE suue as M l ,f l '*~ 1:!I a ^ tp y A 8 l 7 1 6 l

ra, @ =. H A$"* ~ 9 g

- -4

-a ,1 r p;_ _. I i c. n:::.m M~ J n _., ~-. ;:u.,. 1 ( si ,i, [b -4 r.- 4-A L g- \\ ' C '1 \\ al ___ - /j :. N p e. v _r - 3 h E ' ~ ^ I 71 _' g <. . v ' m- --- - - --- -...... -../ s

1 p =~

l-9{.-.~I 13 ., i jn lc!

r ll

~ -- ) ,, 2 '. /= _:i, +!H ii,i l. <--%-~~ .=- e m. n f " ~. '. 4 'AL /. M J f.' ,J::t e,- f/ i idh_ L.\\. rs ~ e-- e,..._r._ , /- . N. [ w.-_* g._. --jing.; ;,. ,;,;;=, / a- .----n. 7 ~ \\,.-5 o

=== ::= =: - y e.; ;: 9 -, ' ,.~. s j s mY, d..ie s ,j ._..J _ ga- , _._ _ 4,\\ %. a,. ANSTEC x_.x -\\ Jr 4 ', - j yf,11 41 ~ -. ~ APERTURE 2 ' g=g _. 2. . _.j. _.,. edO CARD )_ T[i._ ! A t' ,frt i ! a ei \\'\\ [\\ / } !:u. P 2 'r ~)t W-^ =r-j%b% p 6._ q.9 l 5, 41 4 M 00,!l ~ O Ago Availa I n h 'l P' ""* kYN [l'" Y \\ rt.T ._._1 f" h l$ /\\ \\ y/ d % s

g.
  • S--

-A 4." - - , p. I . 'j/- M,y N vrJ I d $_'~ K'.

a....d lG

/ // ,/ ,4 h ' A. \\ - =:: T M '/,.'f 3 4';' N'gg 5E ,4,_/I NOTE: HistoricalInformation Only / ~.'7 Revision 4 / -:.w lih.< W.-..s j .A s~.

==. m-- = -. ~, ' s A.- e - =% g3' /gg[Mff-I ~ es -. m_%.vha.e / ii 'l 8l-Figure 3.2-19 Equipment Location. sman j'm"., llll:: g_='-** '=== /,,,i ,--c 8 p=:am. w =- =--- p, W: Er v Reactor and Aun.h.ary i l P l lAJ J i M' i Buildings. Plan Operating b.. 6 Floor and Above .L9 6 5 l 4 1 3 1 2 1 1 e.

assJD-i T I N h.e I f I t I i / / n G / =%e f," l l/ .w, / e e..e 1 / Y

    • r*
  • v

%e* m i i ./ l F .f . c me 3% w l I muse g n __ v as m . JtifStX l I p.? _ f.. a Ebg*# gg g l 4 l' y~ ap w M ' ~ ~. '"****"~ ~ dE l tI il i E 20* e "'"*- t Jo e 4 i D r.,,.-u ma-j wass mesen on.e ung i g. g-- l ' hit D".- - -t

i,

r q a i! n.es,.r%7 a;r---me: i i qqw ,1 .L,,,f. N ir" E,. mm aa m m 'N f fussi sue a e t

  • s'N

' * " = **-

=

asume .i w.p k' s (**- D j Y,#nmDi$ . I ' ' " ", *. - - * * = ~ ,g,,

    • Nat mese estems

'41ue 1rfr '1 .p..'."a-f*"j" c i WM ~. -.7

;==-*= I' ef 4,

...a,,.- f-~ u e 4:p l' .gy_ . _ _. - _ ~j a C

  • a===-
i F

,mw~ J ..~. ' M j (r.**.n**a ..w i .zy

W

) p ~ j )'

t... i

~ I: .c=a 6 ! 'I __ l j - b$ -i t-- a.,.- ? -i ]m7 l i. , <. _. d,,, g::~. %, [!'"fl - ~0 ! ~ ~J_! ,q-+ jj, d -c. Meheef B ,4, 3 ,} w

.b" Ii

\\

  • ~"

gg.,, a \\ ,r ' \\ s s.:.<..:.r.a.as_t t ..w t e.ae - e. 4.. w e\\_ e.o v.--.=t a'n ', t A o-8 l 7 l 6 l i

N' sN \\ x 7 N sn I h .o...v. r I I zes .r - r c-- N i f c; E1 g' v a I: p i.. _.. ~ g ,J.-,-. 9j g ANSTEC l o-.. v, 1 APERTURE JV 1

t. ~ sum, cue.. -y..!

i CARD _- : - ~ l,,, ^ " *' + s, i ~~.o., .A j,y 'I Also Available on F ~ l Aperture Card s t l ,l [ T.1:.-' l~m, fg.... ( ~3-

b e-f
#""

If pa gyp. -g; g .-i - r m... v r 1 . a _r-.- g_._ p: __r.---- i

l 2--

i q,7 .1.- t" f ~._=A ~* b_, .:N,es sse s X

r.,'

~ c - m. 3g Figure 3.2-20 Equipment Location, fh/f0f$DY A ..... 1 L y Reactor and Aun.h.ary =. _.. NOTE: Historical Information Ordy Buildings - Section A-A Revision 4 s i 4 i 3 i

l l E r H [ s _ _,e nr. ii 1 Q f-- l S. @ i, w. i - ~. - v

y.,

-e_,,,,,,,,. /a p y -T _ ! =** t 3 5.' l u s -,.1'U."..q;i ~ l JC'I l 4:f.:: l-(- e o tar r% em d ' f"~ l l.9 ka s n n g tA i e o .- 9 4 r .v - i l i A:",.r. h L . 'zj=},5 (f R dn ?s I i"'*$m-.:. !I vSO $=<; % r q I M O.P C - e /== ! 13 6 ir 'w W r n: gi t t .,.g, !q -"' " 'p % l p p'i l. f:'M"N i 'l

  • aaa -

i1 - s.a.s g, 5, _ D ji 5 Yd - ' '! ' m le!LS't. 3,i ; W y 2 1 , =.. i -

3 e

96 - e n 2 p ', lli w. ,9,..< = . ur=a ,.4 l ;p .mineuws-gl=.,,- .c ',, ; s.i**"f't! GM' 4 .M %..;t1g,,,,,,,, y y& ' sd r-i ' 4 . Wry \\ uu f,; j. m v.e g, .I

A' t.....

i,. -{'ga* *~ g a ct an iJ tr.a s 1 hat M j '.a='m ~ $ ' M i._ f r s

,i * ] ',*"*' -

i

  • ""'""*M, I ld e 7,g. - mnej.1 s

2Y *,. A., w' ' E l i N.sa. i , 4 "?_"_6 f l_,.gaa-'", W e-t"*t-w 4, I ,W 4 i i!

h..t +

.,,.,,.,..,,,-x _M ~ d aing y -k bE I -m1 f} j. f' ' {~'ll p,.f... u, r_ r r Q dog m l. i. L.._ Y-g',,N.w n-. -r ! J.. U,.,, m M W M $ I $.a.m.== i .- m-0 i.7. SECTlON C'[ g 9 C a 1 T, ~ L M2 ] -eas.e F. ~ =. I c -I"-,. I' .~.3. l v., , e, o ~ deucamas sm e deem .Jo se. 4 [ ... A A. .ac! mat tuAin ~ , w. e=., 4 ~ i f. ua - ~ ^ * " t . orr au semaM sench ~*-a 6 'WW - s [M d'*'* mc u.4 ,.u -4, g, ., _4.m.aer.--r-l u

  • tua

'u-j

  • I'es* I m m B

..~.,. sg

    • ws
ll w

es= <.. .us u. yv c.-= ( t "['M1."'" i %L 3 en q.- me.m *. . 7. .I g *- =*. y D' t s w : = se

y. u.,,,. a

...: a g ~ h qq=*st - d*. _.,;, 2 A _ " _ _ _ - -. - - - - - -. _ - - - - ~ r L U U-- 'M .$.h.# b$* g l 7 l 0 I

O S ? ? ? .,n.. i o., i 4 ,.e y-.___ o. y _ _ _...

l..

~ I l r M l w-v w... ', el c _a.4.d P i,g .. y,,,,,,,,i i 1 r "s ss 4A 4 4 r .:=-.s., h 1'a,- s ._.. c.. e.. e I, 8 g.Q = , tl 5, A ,i U n=*l'al 'l'- I l.. [ 1' N'. j ' I - il... l' l ,,, W i 't k - Ll ..- +A a i N' '4 k!* TL 4'1 4- ' + " a.'*-- ~ =.. x. ri i.t=$ m. _ =__ n, - .m _....-..a} tl% L.r e.e.ta.*" sb. ma4. ~ m _ _il ' h i _M8-**',a.=...e r%,) e,g}; _ : 2 )' ,P l en. .,; y ' . M. r.. + m.a e. .ur ia. . g k ';. ME--- w7 r i, I f, ~.. ~ I 4.m _ ,i % l io

  • ru,=x 5-.--., wc.

im r e' :l.1. J L-5 e -W ' ~ %.;. w T.,. ,s ~::. ._'*W_+-,>.. ~ .; g... ff, t. ma. -a - n - i s ,m _u e 'E l 3.- .um... I au awt. h.A , li ,,.v. ;ii..' 7 ^ u,e, . u __ ' -.._ ANSTEC r. g.: = c. ;". W~ APERTURE ,~ g-7, gr ,_...~ .u. i i t _.c 'e % w I Also Available on e- -c- -l ~ ~ w "' Aperture Card s=cm r a e t 4 I c ? -r ...,.m,..- i j O - r-nyrTryrv4..n#....,., T. ~mg Tyri.t'd o .....,. n m.,... a,. _ ~

  1. ,._,..m 3..

.m, s. "~. g '" w.g.-,;- 3 7 3, g. q.3. 5.. g's, s'.lj ,,....o

  • ='

ns,,i .r ~ 4 w ! '., s.- q .w g .......r m.

"'.'"J )m dC

_.m. s F. r-

3. -

i n NOTE: Historical Information Only 1 n Revision 4 I = =.., [ ' f(p/2 0 $ 06 D ' i U 9e,...l...y~i.. .,,..a -~ J ;,!, n .. r:= -- > - +--em n. i :!! .7

4, z._..,

Figure 3.2-21 Equipment Location, L n 'f.QC

i Reactor and Auxiliary F

. e-n um ua j [.", E 0 Buildings - Sections B.B, D.D, E-E, F-F

t.., -

.: :._.s -a.

==-v..,.c,.:.... g =.s 5 1 4 I 3 I

N c._.A. 3 g~. I ~~ O P ll l: F l

)

a =m l l1 l E e e! I r: ] e w,i r i.l - h T; i' f~ EJ J O ' = *

  • i
    3.*.""."

ll u, _. (.m 1s. 3 ~ V .,dV *!f( h l /fS l- / d M? d i

_,Q f em=*" ;.6 s

C { k l 131*=*= $. Q,_.@[ / I $ eme i /k m A m NRA d,8 '\\ l l' j m m, l m i .\\. [ p.];. ).,.,, l l MUMM !/' \\.. l M l v =. 39 I b =:=',;,:" l k arr* O.f7 O' w smt f,, ,l k J soM -+5 lj ,L J,,, kE_ p.e m.

-jN{"o_il_#7. i I

jh N r- ~ ,1 b il L" 7..M.. !)'Ib d -l l u A \\ 1 u~.:.- s ( 7 l a l

...._4 i N, p ,/ \\. / = /+ ANSTEC ,/

== ^ / I APERTURE / CARD h I' l 5 I I p Availabit 6ft k ,NAperture Card h P3 4 g__ y 4s m_., a = _... l =r i @l4 gf T a 4 Y b W_ f

A

~ '?: i T } m .m. W: - fy_ ' " ] y 2._ m. q sc, c.c, - a x y k n-; %.,h+ _r a Ip l 1 ', p-c i l ru i l ...u. .u u -- .m ,c- ~ ~ ; i .I vg; i,,% % .,. r-A. ._-l m yar._ .g, i ci -l i r I:I ,i 1

P oi4 i srew F-F

?

2r4:. ' ;

t. l.. i i _s- %rget=L s=-- i .- ~9 l A 7 gr - ' - lI

u -+

e 4 ,{ az, ._,.= %~ J u -, "X. C r-. gl g Pa*f) i ' Paa o I di 1 q s f:lll'== !_. i

i i

i ,0~*" ! [1-I/*Mr F# bA M A $:==.F";' 3 .. u l Jt-l e? M A l.*= : I.j y-; [, ,.e... k,~ y -9 l 8

M*c J f li-kw'7,[....IL/iQ %j-yJjjfp.{p'lg.,i

.I 3 ,,,., :.;- 5 'y' B S.t g >u ~..lr.,'.r; T' OJ, e, 4 t -- t 5 I N / {/N Figure 3.2-22 Equipment Location, i. l -/ Reactor and Auxih.ary .t-.m C-C c Buildings - Sections C-C and F-F 9 NOTE: Historical Information Only Resision 4 s i 4 1 3 1 2 a.

--J --a -una-- 4 -s a-- 4 444-6-ma-J----Ak-e-

  • 4--

4 4,--A--n -Ce& =L on 6 -ne b C U o 3._ Y V j f.3 yv U 5 2 s 51 M .i l i i i i ' Ea Ei nl .L >g3 l.2 W s '- y v I, ]!!'!a s ~- y 5l s! M,,i

!!'![~

l i it Z To,. T. i v I p 5 v is igl 4 3lmaf f. i I, i v l 7 g, d I Ad% 7 u i l 7 4 I F[* { c o-l' ,f s""e

  1. ,5 E4 8 l

-a -a e ss U l l f I 4 1, i i, 3 I m .o y ,m w ,, WS W M S 7 I I !a. !:s 3 ).3 a, 3 = f.o - ~ i i n a, t t u ~ I 5 k j g a r I I 5 i l =, : 5 l i 5 .c, i ? 6s . hl l e 4 N M \\ 6

~3 a

l l I' 2 l l -= 1 -lml - l = ~ v i t 1 U iIEl ~ ~ . 5 J. l y .I I~~ k 2{.. -: {. 1 Y" I I T" '~**.*,6 / ) t n l ~~ f G ~ .== l =y l .~ l r t,s. t .5 nr. l lil!3 jil!G -8 -n v v v v i xT WN A H 's;, r l 1 I I .y

'N gn e

e gn 1a a f.

s.

7um ! C k f. E ,f,i. i [ T y A 7 -{, V ( A i t Y a A d A d i i i or ni: u;!: a! Essg, 2;;I is.g-

s 1

m 3 x2, i o--n ,c, 2 +- a-a a2, f z --* l S.,c j Y e I s!- = I = l c /

  • Q e_

t >o M ll* a E ? EI l I 2 5 l~l l lIE 5 a j' l + I I 5., i O b S

  • ~ 8 5) f*'t c. { n~l
"~ i l Of E

1 s k I a 1 0 1 l 1 3 =. = =- + 4

i i

i - e rIf Ie)y l p T T T ST w a i I !, Ai 7 7 S !i. ? = 7 7 I - r. t _e s 6 e i I' 3:h h U N E F-9: g. o a .): ): l' l' si -e ) a l l E *! -I 4 R i l' 1 p :1 pe; : J v2 i i y l l 1-n l l 3) II l 32s !st k i j W,- _:._, s: +_ kVI O

a=

J

r. 3-
ws 3
  • v ;E r=

a e g ir,g w aa y I i $) 3 T ) Md g m i = y v z o e (A4 A ! , ap\\g h. M t io e f a r ->+- { !" {! e.5. a 4a_ W ->4-= ,gr 4 4 X -1 x 2 1 I l s .\\ .\\

g!

3=y!i 3ri! 23[3' !! gs !)y 4 4 3

  • !p;3

-g A s O 'M' >O-tN ' C .d e38 aw p ( .Ijc=I !!)t!I '~' ~ + hg 5 5*3r b n3 .J n .= s i II !!j O + (3 ' 0 O[ .u-i j-z gga"

4 0 OPFR ATIONS This chapter discusses facility operations related to the safe storage of irradiated fuel; including criticality prevention, chemistry control, instrumentation, maintenance activities, administrative controls of systems, spent fuel handling, and spent fuel cooling. To focus proper attention on important equipment and activities during the defueled condition, cenain structures, systems, components, and activities have been categorized as important to the safe storage of irradiated fuel. l The following structures, systems, and components are categorized as important to the safe storage of irradiated fuel: (1) Safety-Related structures (includes the spent fuel racks; Spent Fuel Pool (SFP); fuel transfer canal; cask loading pit; thel transfer tube; and the Control-Auxiliary-O Fuel Building complex). V (2) Quality-Related installed monitoring equipment used to satisfy Trojan Technical Specification (TTS) surveillance requirements (includes SFP level monitoring and SFP temperature monitoring). (3) Ponions of the SFP Cooling and Demineralizer System that support the primary method of SFP cooling or SFP water purification. (4) Portions of the Component Cooling Water System that support the primary method of SFP cooling. (5) Portions of the Service Water System that support the primary method of SFP cooling. O 4.0-1 Revision 4

l (6) Portions of the Service Water, Primary Makeup Water, Demineralized Water, and l Fire Water Systems that may provide makeup water to the SFP. l l Activities that are important to the safe storage of irradiated fuel are controlled through use of l appropriate approved procedures. i 0' 9 Revision 3 4.0-2

10 , V 4 2 SPFNT FIIFI. HANDI.ING 471 SPFNT FIIFT RFCFTPT MANDT.ING_ AND TR ANSFFR License NPF-1 prohibits the movement of a spent fuel shipping cask into the Fuel Building. This precludes the receipt or transfer of spent fuel. Movement of new or spent fuel into the Reactor Building is not authorized without prior NRC approval. The movement of spent fuel assemblies within the SFP is the only fuel handling activity authorized. This movement would be accomplished by use of the spent fuel pool bridge crane and spent fuel handling tool. Since i spent fuel handling is limited to relocating assemblies to alternate storage rack locations, inadvertent criticality prevention is provided as described in Section 4.1.1. 4 7 1.1 Functinn21 Decerintinn Figure 4.2-1 provides a layout of the spent fuel storage area. Movement of spent fuel assemblies is accomplished by use of the spent fuel pool bridge crane and spent fuel handling i tool. 1 The SFP bridge crane consists of a wheel mounted walkway spanning the SFP. The SFP l bridge crane moves in the north-south direction on rails by means of a two-speed motor. The I SFP hoist is a 1-ton capacity electrical monorail hoist that moves in the east-west direction on the overhead structure of the SFP bridge crane. The fuel assemblies are moved within the SFP by means of a long-handled tool suspended from the SFP hoist. The spent fuel handling tool is a manually actuated tool used to handle spent fuel in the SFP. Fuel assembly inserts, such as thimble plugs, burnable poison rods, rod control clusters, and source rods, may also be transferred between positions within the SFP. 4.2-1 Revision 4

i J Load movements outside of the SFP may be provided by the Fuel Building crane. The Fuel Building crane is a 125-ton pendant-operated crane and is provided with an auxiliary hoist rated at 25 tons. The Fuel Building crane is restricted from moving loads over the SFP. The Fuel Building crane is also limited to moving in a way that avoids the possibility of falling or dropping objects into the SFP. Mechanical stops installed on the rails prevent the crane hook from traveling beyond the centerline of the cask load pit. Electrical limit switches deenergize l the bridge drive before the mechanical stops. These stops and limit switches may only be l l bypassed or removed while following an approved procedure, and then only with the Shift j l Manager's approval. 1217 %ferv Ntures The SFP bridge crane incorporates design features to minimize the probability of a fuel handling accident. These features are discussed in Section 3.3.1. Administrative controls in place to minimize the probability and consequences of fuel handling accidents include: (1) Fuel handling operations can only be performed under the direct supervision of a CFH. (2) Fuel handling operations must be performed in accordance with approved Plant procedures. (3) Loads carried over the SFP and the heights at which they may be carried over storage racks containing fuel shall be limited to preclude impact energies over 240,000 in-lbs. Revision 4 4.2-2

\\ t (4) The Fuel Building crane is restricted to operation within the cask movement envelope shown in Figure 4.2-2 for heavy loads, except when following an l approved procedure, and then only with the Shift Manager's approval. l 417 SPENT FIIFT STORAGIl \\ Section 3.2.2 provides a description of the SFP design including the storage racks. Although SFP storage rack capacity is 1408 fuel assemblies, only 781 fuel assemblies are stored. The SFP cooling system provides forced cooling of the spent fuel assemblies. Bulk SFP coolant temperature is maintained between 40*F and 140*F. A more thorough description of the operation of the SFP cooling system is provided in Section 4.3.1. Subcritical arrays are ensured by maintaining center-to-center distance between adjacent fuel ( assemblies and the fixed neutron absorber contained in the spent fuel storage racks. Additional discussion is provided in Section 4.1.1. Radiation shielding is provided by the water level maintained in the SFP. A minimum of 23 feet of water is maintained above the top of a spent fuel assembly in the storage racks. During fuel transfer operations, at least 9.5 feet of water is maintained above the top of the active portion of a fuel assembly. This water barrier serves as a radiation shield enabling the gamma dose rate at the pool surface from the spent assembly to be maintained at or below 2.5 mrem /hr. (v 4.2-3 Revision 4

emergency makeup water source. Systematic guidance is provided by Plant procedures for leak identification and isolation. The only requirement to assure adequate cooling for the spent fuel is to maintain the water level in the SFP so that the spent fuel elements are not exposed. All lines entering the SFP which could siphon the pool to Elevation 76 feet 7 inches or below (equivalent to approximately 10 feet above stored fuel assembly), are equipped with siphon breakers to limit SFP water loss to an elevation of 83 feet 11 inches. The SFP gates for access to the cask loading pit and refueling canal are equipped with inflatable seals to prevent level loss to these adjacent areas. For a postulated event wherein the SFP is drained to the Siphon Breaker level followed by failure of the SFP gates and subsequent spillage of SFP water to the fuel transfer canal and cask loading pit (initially assumed empty), SFP level would reach a minimum level of 76 feet 7 inches, or 10 feet above the top of the fuel assemblies. Additional discussion of the SFP design to prevent loss of level is contained in Section 3.2.2. Accident analyses for l loss of SFP level are contained in Section 6.3. .1. 3.1.3 I nu of Snent Fuel Pnni Cnnling As discussed in Section 4.3.1, a high temperature alarm is provided in the control room with a maximum setpoint of 135'F. Plant procedures direct actions to restore operation of SFP cooling. As stated in Section 4.3.1.2, the only requirement to assure adequate cooling for the spent fuel is to maintain the water level in the SFP such that the spent fuel elements are not exposed. Procedure gui. dance directs the restoration of level by the use of makeup to the pool in the event of level loss from boil off. Restoration of SFP level is discussed in Section 4.3.1.2, IAss of Spent Fuel Pool Level. O G 4.3-3 Revision 4

4 31_4 High Snent Fuel Pnni Irvel A level switch has been provided in the SFP for the purpose of transmitting high and low water level annunciation signals to the control room. Plant procedures are in place that provide guidance for the systematic determination and isolation of the water source. Overflow from the SFP is directed to the dirty waste drain tank. 4.3.1.5 Raferv Criteria nnd Aunrnnce The only requirement to assure adequate cooling for the spent fuel is to maintain the water level in the SFP so that the spent fuel elements are not exposed. The top of fuel seated in the spent fuel storage modules is located at Elevation 66 feet 7 inches. Dose calculations for fuel handling accidents assume a minimum of 23 feet of wcter above the top of spent fuel assemblies; therefore, SFP level less than Elevation 89 feet 7 inches requires operator action to restore level. This minimum required level also ensures dose rates at the SFP surface will be maintained <2.5 mrem /hr during fuel movements. i A SFP minimum boron concentration of 2000 ppm is assumed for certain design basis l accidents to prevent inadvertent criticality. Sampling frequency and corrective actions to ensure boron concentration is maintained have been implemented. A maximum temperature limit of 140*F was assaned for SFP bulk temperature. This limit ensures that for the worst case loss of SFP cooling accident, SFP boiling will not occur within 20 hours, and that at least 4 days are available to establish makeup to the SFP before boil off would reduce SFP level to 5 feet above the fuel assemblies. Maintaining 5 feet of water above the active portion of the fuel provides adequate radiation shielding to allow access for restoration of SFP level. Table 6.3-2 provides estimates of radiation dose rates for various SFP levels. l O' 4.3-4

i i l 4 r 412 FT FCTRICAT. f)TSTRIRTITION ' 1 Durmg normal Plant operation, Plant electrical demands are provided from the 230-kV ) j switchyard. The design and reliability of the offsite power source are discussed in l Section 3.4.1. i I Offsite power is normally supplied to the Plant distribution system via the stanup transformers, j I i In the event of loss of offsite power, forced cooling capability would be lost. Without l l restoration of forced spent fuel cooling, boiling of the SFP would not occur for at least 88 l hours. SFP inventory is adequate to allow boiling for a minimum of 2;.5 days without any l j source of makeup and still maintain > 10 feet of level above the top of the spent fuel j assemblies. Makeup capability to the spent fuel coolant system independent of Plant power sources can be provided by the fire main system (diesel-driven fire pump). A discussion of the . fire main system is contained in PGE-1012, " Trojan Nuclear Plant Fire Protection Program." { 4 3 3 SIIPPORT SYSTFMS I. Operation of the SFP cooling system is supported by the CCWS and SWS. Decay heat i removed from the SFP cooling system is rejected to the CCWS via the SFP heat exchangers. f The SWS provides heat rejection of the CCWS to the Columbia River. Decay heat may also i be rejected to Containment via the CCWS and Containment Air Coolers. Other Plant support j systems include ventilation, radiation monitoring, and radioactive waste systems, which are discussed.in Chapter 5. 1 The CCWS interfaces with the SFP cooling system providing for heat rejection of the spent ) fuel decay heat via a SFP cooling water heat exchanger. Normal operation consists of one ] l component cooling water pump in operation. As a result of Plant defueling, the in-service SFP heat exchanger is the only required component cooling water load. Component cooling 4.3-5 Revision 4 d

water flow to the SFP heat exchanger may be throttled or secured to allow for maintaining SFP temperature between 40*F and 140*F. Loss of the CCWS can result in a loss of SFP cooling which is discussed in Section 4.3.1.3. The loads and design basis of the SWS are discussed in Section 3.3.4. In addition to providing l heat rejection for the CCWS, the SWS provides a makeup water source for the SFP. O l l Revision 4 4.3-6 1

I-4.4 C'ONTROI ROOM ARFA The control room provides a centralized station to monitor operation of the SFP cooling and suppon systems. At least one person qualified to stand watch in the control room shall be present in the control room when irradiated fuel is stored in the SFP. A discussion of the activities normally performed by the control room operator is provided below. i SFP cooling instnimentation available in the control room includes: SFP temperature indication, SFP high temperature alarm, and SFP level alarm (high/ low). In the event control room instrumentation becomes unavailable, the control room operator can utilize local monitoring of spent fuel pool temperature and level. All operation of the SFP cooling system, including normal and emergency makeup, is performed locally since remote operation of SFP components and makeup flow paths is not provided in the control room. Operation of the Plant's electrical distribution system is normally controlled and monitored in l the control room. Local operation of the electrical distribution switch gear and load breakers l can be performed if required. Operation and monitoring of the CCWS and SWS is normally performed in the control room. In the event control room indication and control become unavailable, redundant control of the CCWS and SWS components is provided locally. Additional systems that may be monitored or controlled in the control room include: (1) Plant Ventilation. (2) Area Radiation Monitors. (3) Process Radiation Monitors. (4) Fire Protection. 4.4-1 Revision 4 3

1 4 S RFFFRFNCFR REFERENCES FOR SECTION 4.1 d 1. Trojan Nuclear Plant, Final Safety Analysis Report, through Amendment 19 (December 1992). l 2. PGE-1012, " Trojan Nuclear Plant Fire Protection Program." e 1 i REFERENCES FOR SECTION 4.2 1. Trojan Operating License, No. NPF-1, as amended through Amendment 191 dated May i 6,1993. i 2. Trojan Nuclear Plant, Final Safety Analysis Report, through Amendment 19 (December 1992). / 3. PGE 1037, " Trojan Nuclear Plant Spent Fuel Storage Rack Replacement Report." 4. PGE Calculation, Trojan Spent Fuel Pool Heatup and Boil Down Bases, TC-720 Revision 4, dated 11/12/%. l L 4 REFERENCES FOR SECTION 4.3 1. Trojan Nuclear Plant, Final Safety Analysis Report, through Amendment 19 (December 1992). 2. PGE-1012, " Trojan Nuclear Plant Fire Protection Program."

t 4

1 O 4.5-1 Revision 4

O O O Page 1 of 2 TABLE 4.1-1 SEISMIC MONITORING INSTRUM ENTATION INSTRUMENTS AND SENSOR LOCATIONS MEASUREMENT CllANNEL CilANNEL CilANNEL NOTES. RANGE CllECK CALIBRATION FUNCTIONAL TEST TRIAXIALTIME-IllSTORY RECORDING ACCELEROGRAPilS ST-6336A (Containment Base Slab) 0-2 g M 18M SA 1, 3, 4 ST-6336B (Containment Wall) 0-2 g M i8M SA 1, 3, 4 ST-6336C (Fuci Bldg, Elev. 93') 0-2 g M 18M SA I, 3, 4 ST-6336D (Cable Spreadmg Room) 0-2 g M IBM SA I, 3, 4 ST-6336E (Free Field) 0-2 g M 18M SA 1, 3, 4 TRIAXIAL PEAK ACCELEROGRAPilS SR-6340A (Containment Base Inside,45' North) 0-2 g NA 18M NA None l SR-6340B (Intake Building Roof, South) 0-2 g NA 18M NA None l SR-6340C (Top of Containment Inside,201' 9" South) 0-2 g NA 18M NA None l SR-6340D (Control Building Menanine, Top of Ladder 0-2 g NA IBM NA None Above Secondary Sampic Storage Room) SR-6340E (Fuci Building,93' Ilot Shop, West, Behind the 0-2 g NA 18M NA None Wall) SR-6340F (CCW lleat Exchangers,45' Arca 3 Base) 0-2 g NA 18M NA None l SR-6340G (West EDG Room) 0-2 g NA ISM NA None l TRIAXIAL RESPONSE-SPECTRUM RECORDERS l SR-634 I (Containment Foundation) NA M i8M SA 2,3,5 4.5-3 Revision 4

, 9 -. y si oj g-) s r .. 3 l ~ \\ ,1. C c, i a,a m kB , FUEL 4Loe.atices 'euLJV g, G p h necesseo.c.s.m e-ps< svo. ~J .o, P NNM l l NOTE: FIGURE 9J-l 15 TAKEN FROM @JTURIG) 'h'. lrST1 "O H u-20 SHTJ. REVISION 19. 13 Isme M I: t3*.0= 1 I 4 {-, T 3 c-== i a e-l \\ NEW FUEL u w c w Aviisc suce' l t o i e een , W RAM. d*# _i M. 1 5tm i \\ i 2 ( l g y \\, e i-) o .a , i r1 4 j l j i 4 4 __ . + - / !Ty _x. -- c ~- t . mu e4 r bW~ i l l H 9 w )R \\ $P ) Kl' /*"s l' N Iw J g / g l, c-y i teo i I .m ) l / i { 4 l 2 ~ ~ aw 1 r\\. g w i .,/- tc,g

insamus, r6

( k. L. g ~ m cTT J / p b f~ l/ 0 ^ i 1 8 7 l 6

erteGE % .s_ v.. / .L.; m. M f N / I i /15 SSEERGE SmCES SIEWEREE CSIERs

  • M **7 i

m yij, n. ye i r _i-~ ge wo, Tr 6thd l N 1 / E ~ 4 1

  • \\

y j a \\;- I y hew surL F Baaet au D CLCANING i BT L-50(e I im-

== y b. -.ewau p 4mm L e v, t t i 1 / l ,i y t f marr nut. 8 L-ass EE came g t f -"e"nGE censEE ',i., &# # spear Rat, stonaec poet. S Uurr MsEL supG rio.e cran a ANSTEC a< APERTURE II E CARD R Also Available on v I-g =, ~l-- p oord ces tW g , y assi _7 %y$_ .is.., t' fone ier L m ano m ,o---. da3l ~] _4._ w e p ~ c -p. 1 umoras/ e r*-a',.p .t _rm yn I w- ! J b d. l' l I y jdC. Sie e'-s m I 3 \\ -Tirad w N y IR C-t ~., %/20506Y7-m ~ -ovtra $JIT e Figure 4.2-1 Spent Fuel Storage Pool Revision 4 5 j 4 3 j a-

? 9 9 9*N 8 g a,. me ,,,,, j i i r p H,- 'nt un ~ ~ ~ ~ ~nr v:P. @m u sty * =. L.'.=._ "s:"A I e i i lt - .j l ~,+" ~~I,c gJ r.2 4. h-.=3 __O q :.c.= l.T - .'.3. l.. . --s f .-r-y c1 .m g I , w _., e,, q ~~ f.. < 1.: nar-m: ,,,y y e*. l i t i 7, H .l

I

=* L. i l hk, m, n / i p d lI ._.. y_1 L '-*. - .=; ,g, ; m L_w ,,m_.= / 3 t ,d t. l m._ b.s a. .. w w t_ : f 3 t= lf'- g.. = p._,. w-- b w OLAN af 8_193 6 1 1 g p r 4 I i _y,- - ~:.:-- n 'e,p ! :,q lli A W,.F... j...

8...._ D.

_ 5.__./ l i .s >'t - I 'i t i . i,. v.

4.. v. :, v 4.;.,,

i p. _C g.. l ..~. :

  • ( * '

.,,_,I . v. .I ,. _....,. '.. V, 9- [~...,'. m

  • ""'"~h,

. M,. N ~ **a ^ e ?-='~'- h 'I' " Y f ~ es N;! ise$'(4. yl

g... l}

,=: __ i c i. j

-**~

y q" 3:, r. tJ ls6 d,_L tj /' l l 8l l F . ;. /. _,,.', ! -- m. sc._ N .2 l WF [ SII.AN Af fl 774 1%j f g ,,. a.- m 1-N %y Gf T.1 [i m prP A. p.. m &- g,_, __ t..m A -m =

b. I %.',,h, y i,' ea-a _

a $ *.'f.*,.M. i;,s ?.* p ' o' v s'* .-E....- r m c. L2... l: . v l ' _v =,l e.s 4 l [q [ ls i p l ? .ene.d l , l

  • i f*

L". ._.9 f - _ r. --. t b l,1 J. p i hnl. = :-: _ W-W = i _g f: q j; - a j4 api. 6'-'6 8:a J. c-m = i s. " _.q.... _. -l,- -,. i 3* n j ,.i._~_. "= DL AN AT EL Gl' Y r-- /..i 's..,._;,f n - =r' g t.

s,, F. l t, n

.gg. a%.. ... =., - f, r ..). .!..,i o i I i -~ ~ i. v _,~.. i n v. I,., g .f. =:. - l j 1 p-r > gn F,c. I L g y f _s. __._ 3 - i.i_. _,_ _ l l .g j <.-5E " - '.

  1. i 3:%

E.j l l--l.. l i!! 1 ~.. 4 I l 2 AN Af fL Ja g l

  • = - = = =

9 s ~ S 6 ..m . u m.m -w.e .m. -.- m w. s.~~.. Figure 4.2 2 Plant Arrangement Diagram of Fuel Cask Movement Envelope %wimp

operating time at full power which was assumed to occur at the end of each month. This is conservative m that it places more fission events near the end of each month and allows less time for decay to occur during a month. SFP decay heat generation for a decay time of 40 weeks after shutdown was utilized in the analysis. Figure 6.3-1 demonstrates the effects of j decay time on the heat generated in the pool which increases the safety margin with increasing time since reactor shutdown, t [ The evaluation showed that under the assumed conditions and at 3% years after shutdown SFP l I boiling would not occur for at least 88 hours. Boil off rate would be no greater than 3.7 gpm l l and at least 540 hours (22.5 days) would be available to establish a make-up source and still l l maintain at least 10 feet of water level over the fuel. Figure 6.3-2 provides a graph of SFP ] heatup rate versus time after reactor shutdown. This graph demonstrates that additional { response time becomes available as time from reactor shutdown increases. 1 2 A j U Figure 6.3-3 provides a graph of time available prior to SFP boiling based on the time after 4 shutdown. The time to boil is based on an initial SFP temperature of 140*F. Figure 6.3-4 1 j provides a graph of calculated boil off rate based on time after reactor shutdown. Figure 6.3-5 provides the makeup rate (based on a makeup water temperature of 100 degrees F) that would 1 be needed to maintain SFP level constant until forced SFP cooling could be restored. Time available to establish a makeup source prior to SFP pool level being reduced to 10 feet above the fuel due to boil off (i.e. no inventory loss from system leakage) is provided in 3 Figure 6.3-6. For inventory losses due to boil off only, more than 3 weeks are available to l establish a makeup water source. 6.3.3 LOSS OF FORCED SPENT FUEL COOLING WITH CONCIIRRENT RFP INVENTORY T OSS Certain events exist which could result in loss of inventory of the SFP. The events that could result in loss of inventory are discussed in Section 6.3.1.1. Regardless of the initiating event a bounding set of conditions can be established and the bounding 6.3 5 Revision 4

consequences evaluated. Three events were identified in Section 6.3.1.1 that could result in a loss of inventory. An explosion, a seismic event, and SFP cooling system pipe failure were considered to have the potential to affect the integrity of the SFP cooling system. The seismic event is considered to be the most bounding since this event has the potential to affect all components associated with SFP cooling system including support systems. The following bounding initial conditions were assumed to exist at the time of a seismic event: (1) Initial SFP temperature was 140*F. (2) The fuel transfer canal is empty with gate closed. (3) The fuel cask pit is empty with the gate closed. I The seismic event is assumed to cause a failure in the SFP cooling system which results in the instantaneous draining of the SFP to the level of the siphon breakers. The gates se fuel cask pit and fuel transfer canal then fail resulting in additional loss of level until equalized with the SFP level. This sequence of events, though unlikely, is conservative in that it maximizes SFP inventory loss. The resultant SFP level for this event would be 76 feet 10 inches or 10 feet 3 inches above the fuel. The SFP cooling system and SFP structure design are discussed in Chapter 3. Based on this design criteria this event is considered to be the maximum credible inventory loss prior to boiloff. The remaining discussion will demonstrate that adequate time is available to establish a source of makeup water to the SFP such that uncovery of the fuel and loss of spent fuel cooling is not credible. Heatup rates were conservatively calculated assuming a stanmg water level of only 10 feet above the fuel. To account for the possibility that pool heat up may not be uniform additional conservatism was incorporated by reducing the available inventory by 10 percent. Credit was not taken for heat loss to the pool walls or for water available in O 6.3-6

the fiel cask loading pit or fuel transfer canal. The time for the SFP to boil was conservatively calculated to be 49 hours. The boil off rate would then be no greater than l 3.7 gpm. At least 10 days are available to establish a makeup water source to the pool prior to l a level reduction to 5 feet above the fuel. This calculation showed that personnel access for recovery actions was possible with the coolant level reduced to 5 feet above the fuel. Calculations were performed to determine maximum expected dose rates in the area above the SFP. Table 6.3-2 provides the results of these analysis. Recovery of SFP level and cooling are discussed in Section 4.3.1. l O v l O 6.3-7 Revision 4

- - - -. - -.. - - - - - - -... - - -.. ~- f l 64 RFFFRFNrFR i REFERENCES FOR SECTION 6.0 3 1. J. J. DiNunno, et al. cniculatinn nf Dictance Factnrc for Pnwer nnd Tect Renctnr Sitec TID-14844 (March 1%2). i 2. St. E. Steek and B. F. Rider, Rummarv of Fiuinn Prnduct Y'etdc for 17.215_ IT-21R_ { Pu 210 and Pu 241 nr Thermal Fiuinn Knectrum and 14 Mev Nentenn Fnergiec j APED-5398 (hfarch 1968). 3. D. F. Toner, and J. S. Scott, " Fission-Product Release from UO2", Nuc R2ferv 1_ Nn. 2 (December 1961) pp 15-20. j 4. J. Belle, " Uranium Dioxide Properties and Nuclear Applications", Naval Reactors, Division of Reactor Development United States Atomic Energy Commission (1%1). l l S. A. H. Booth A Ruggected Methnd fnr Calculating the Diffncinn of Rndinnetive Rare l Gac Fiuinn Prndnetc Frnm I!O2 Fuel Flementc, DCI-27 (1957). 6. " Report of ICRP Committee II Permissible Dose for Internal Radiation 1959", Henith Phycicc 1 (1960) p 30,146-153. 7. C. hi. Lederer, et al, Table of Icntnne<, 6th ed. (1968). 8. Auumntinne IIced fnr Fv21nnting the Pntential Rndiningical Cnneennencee of n inu of Coninnt Accident for Preccurived Water Renetnrc, Regulatory Guide 1.4, Directorate of Regulatory Standards, U.S. Atomic Energy Commission (June 1973). 9. J. J. DiNunno, et al, Calenistian of Dietance Feetnew for Power nnd Teet Remetne Ritee, TID-14844, U.S. Atomic Energy Commission (March 1%2).

10. ' W. K. Brunot, FMFR AT D A Prngram for the Calenistinn nf Activity Relenese snd Pntential Dncee frnm n Preunrived Water Resetnr Plant, Pacific Gas & Electric Company (October 1971).

11. W. K. Brunot, C. L. Beard and R. J. Lutz, PRFT. A Pmgram for the emiculatinn of Activity Refence frnm a Remetnr Ryctem WCAP-7461, Westinghouse Electric Corporation, Proprietary (April 1971). 12. T. K. Shen, W. K. Brunot and R. J. Lutz, WFDOMF - A Prngenm for the C21culatinn of Potentin! Off Site Dnces from a Renetnr Syctem WCAP-7460, Westinghouse Electric Corporation, Proprietary (April 1971). ) 6.4-1 Revision 3

13. Accimntinne T!<ed for Fvnlunting the Potentini Rndiningical Consenuences nf n i nu nf Cnnt,nt Accident for Pre <uiri7ed Wnter Ranctnrt Regulatory Guide 1.4, Directorate of g Regulatory Standards, U.S. Atomic Energy Comnussion (June 1973) W 14. D. H. Slade, Marenrningy and Arnmic Fnern, TID-24190, U.S. Atomic Energy Commission (1972). REFERENCES FOR SECTION 6.1 1. A<cimntinns ITsed for Fvnlunting the Pntential Rndiningient Cnnennences nf a Pre <<urived Water Renctnr Radinnetive Gas Srnrnge Tank Failure, Regulatory Guide 1.24 (Safety Guide 24), Directorate of Regulatory Standards, U.S. Atomic Energy Commission (March 23,1972). 2. An<i< for Fuel Mandling Accident n< T imiting Case Accident, PGE Calculation RPC 93-025. 3. Seismic Design Cin"ificatinn, Regulatory Guide 1.29, Revision 3, U.S. Nuclear Regulatory Commission (September 1978). REFERENCES FOR SECTION 6.2 1. A<mimntinn_e IIsed for Fvnlunting the Pntential Rndiningient Cnn<ennences of n Fuel Handling Accident in the Fuel Mnndling and Stnrnge Facility for Rniling and Pre <uiri7ed water Renctnrc, Regulatory Guide 1.25, U.S. Atomic Energy Commission (March 23,1972). 2. Rn<ic fnr Fuel Mandling Accident n< T imiting Cnce Accident, PGE Calculation RPC 93-025. 3. Dnses at Fricting & Prnnnsed Site Rnimdarv frnm Fuel Mandling Accident nfter 6 Mnnths Decny, PGE Calculation RPC 93-003 Revision 1 dated 3/9/93. REFERENCES FOR SECTION 6.3 1. Trnian Snent Fuel Pnni Mcatup and Rnil Down Rate <, PGE Calculation TC-720 l Revision 4 dated 11/12/%. 2. Once Rate W. Water Meight Over Snent Firel in Pnni, PGE Calculation RPC 93-24, Revision 0 dated 9/16/93. Gl Revision 4 6.4-2

i a t 2.1 PGF ORGANI7ATIONAT. STRTICTITRE I a 7 1.1 MANAGEMFNT AND TECHNICAT. SIIPPORT ORGANI7ATTON l This section describes the organization of Portland General Electric Company (PGE) as related J to the operation of the Trojan Nuclear Plant. 4 4 717 NIICT FAR DIVISION The Nuclear Division consists of Plant Organizations, Supporting Organizations, and Review ] and Audit Organizations. i i 7.1 7 1 PInnt Organi72tions Trnjan Site Frecutive and Plant General Manager - responsible for the management of the l 1 { Plant. The Trojan Site Executive and Plant General Manager (hereafter referred to as General l { Manager, Trojan Plant), reports to the Senior Vice President, Power Supply, and has l l responsibility for operation of the facility in a safe, reliable and efficient manner. He exercises administrative direction to personnel assigned to the Plant and coordinates the activities of j i Nuclear Oversight, Engineering / Decommissioning, Plant Support, Technical Functions, and l 1 Plant personnel, including Operations, Maintenance, and Personnel / Radiation Protection. l i He is responsible for the operation of Plant equipment, proper maintenance, and establishment l of the radiation requirements of the Plant. l i 1 t !O i 7.1 1 Revision 4

i Mannger Mnintennnce - reports to the General Manager, Trojan Plant, and is responsible for the proper maintenance of the Plant. He ensures that Maintenance implements the ALARA program in maintenance activities to maintain occupational doses ALARA and to minimize radioactive effluent and solid waste generation. l Mannger Onerntinnt - reports to the General Manager, Trojan Plant, and is responsible for the operation of Plant equipment. He ensures that the Plant is operated in accordance with the requirements of the operating license and the procedures of the Nuclear Division Manual. He ensures that Operations implements the ALARA program in work activities to maintain occupational doses ALARA and to minimize radioactive effluent and solid waste generation [ Shift Mnnager - rep 0rts to the Manager, Operations, and is responsible to ensure the safe operation of the Plant equipment. He is responsible for the safety of shift personnel and assures Plant equipment is in a safe condition before allowing maintenance activities to proceed. He has the final approval authority for radioactivity releases. l Mnnager. Personnel /Rndintinn Prntectinn - responsible to the General Manager, Trojan l Plant, for chemistry, radiation protection, the ALARA program, emergency planning, [ nuclear fuel management, and safety. He is responsible for the onsite industrial safety program, and the Plant chemistry control and radiation protection programs. l I I I I I O Revision 3 7.1-2

712 2 Stmnnrting Organi7mtinnc The Supponing Organizations consist of four main groups supponing Plant activities: Engineering /Decommissicaing, Plant Support and Technical Functions, and Nuclear Oynsight. The following summarizes the responsibilities and authority of major supponing organization positions: General Manager Fngineering/Decnmmiccinning. reports to the General Manager, Trojan l Plant, and is responsible for engineering assistance, decommissioning, fire protection, and l design control of Trojan. Under the direction of the General Manager, Engineering / Decommissioning, engineering support is provided for safe, efficient operation of plant equipment, drawing and design document preparation, and plant modifications. ' Manager. Decommiccinning PInnning - responsible for the development of a decommissioning plan for the Trojan Nuclear Plant including the transition to dry fuel storage. Mannger Fngineering - responsible for engineering assistance, modifications, maintaining Plant configuration data and documentation, oversight and direction of the Fire Protection Program and Civil / Seismic Program. Also responsible for providing technical suppon for Plant Operations and Maintenance. Prnject Manager. Cnmnonent Remnval Projectc - responsible for component removal i activities as they relate to facility decommissionmg. General Manager. Plant hnnnre and Technical Finnetions - Reports to the General Manager, l Trojan Plant, and has responsibility for the Plant Suppon and Technical Functions I organizations, cost control, security, training, licensing, compliance and commitment management, and 'the overall administration and maintenance of records. 7.1-3 Revision 4

O Mannger_ Nucient Security - reports to the General Manager, Plant Support, and is responsible for the administration of the Plant Security Orgamzation, implementation of the security program, and the Fitness-for-Duty Program. This responsibility includes interaction with state and federal regulatory agencies; communication and coordination with local law enforcement agencies; direct supervision of the security staff; administry. ion of the contract with the security contractors; selection, training and staffing of the security orgamzation; administering the security screening programs for personnel authorized unescorted access to the Plant or to Safeguards Information; preparation of procedures required to implement the security program; approval of security-related Plant Modification Requests (PMRs). Mannger I icensing comnliance nnd commitment Management - responsible for all activities required to maintain the permits and licenses required for the Plant including producing, maintaining, and interpreting licensing documents. l General Mannger_ Nucienr Oversight - repons to the General Manager, Trojan Plant, and is responsible for the QA Program, for audits that are carried out to verify compliance with the QA Program, for evaluating the effectiveness of the QA Program for each area that is audited, and for supponing line management in event analysis, review, and performance monitoring of activities tLat affect the safe and reliable operation of the facility. He has the authority and independence to identify quality problems; initiate, recommend, or provide solutions to quality problems through designated channels; and verify implementation of solutions to quality problems. He has the authority and responsibility to initiate stop work orders to responsible management, as necessary, for any condition adverse to quality. O Revision 4 7.1-4 i

t 7.5 DFCOMMIRSIONING PI AN The Decommissioning Plan for Trojan Nuclear Plant is required by Title 10 of the Code of Federal Regulations, Part 50.82 and is contained in the " Trojan Nuclear Plant l Decommissioning Plan," PGE-1061. ] l ~ O \\ j i O 7.5-1 Revision 4}}