QUALITY-RELATED LIST CLASSIFICATION CRITERIA i
FOR THE TROJAN NUCLEAR PLANT j
i i
^
1 i
i 1
I f
Amendment 6 i
rx l
i i
i
)
3 r
i PORTLAND GENERAL ELECTRIC COMPANY 121 SW SALMON STREET PORTLAND, OREGON 97204 i
)
i J
%P 9706030288 970528 PDR ADOCK 05000344 g
PDR,,
e LIST OF EFFECTIVE PAGES
.f (V)
PGE-1052 QUALITY-RELATED LIST CLASSIFICATION CRITERIA FOR THE TROJAN NUCLEAR PLANT Amendment 6 Amendment Pace Number Number Date Title Page 6
May 1997 i
5 Sipt. 1995 11 3
Nov. 1993 111 5
Sept. 1995 iv 3
Nov. 1993 v
5 Sept. 1995 1-1 5
Sept. 1995 1-2 through 1-6 3
Nov. 1993 1-7 and 1-8 5
Sept. 1995 1-9 3
Nov. 1993 2-1 through 2-7 3
Nov. 1993 2-8 5
Sept. 1995 2-9 3
Nov. 1993 Table 2.1, Sheets 1 through 3 3
Nov. 3993 Table 2.2, Sheets 1 through 2 Original Nov. 1987 Table 2.3, Sheets 1 through 2 Original Nov. 1987
[
Table 2.4, Sheet 1 Original Nov. 1987 V Table 2.5, Sheets 1 through 2 Original Nov. 1987 Table 2.6, Sheets 1 through 3 Original Nov. 1987 Table 2.7, Sheet 1 Original Nov. 1987 Figure 2.1, Sheets 1 through 2 Original Nov. 1987 Figure 2.2, Sheet 1 Original Nov. 1987 Figure 2.3, Sheet i Original Nov. 1987 3-1 3
Nov. 1993 Table 3.1, Sheets 1 through 19 3
Nov. 1993 4-1 through 4-3 3
Nov. 1993 4-4 5
Sept. 1995-4-5 through 4-8 3
Nov. 1993 4-9 5
Sept. 1995 4-10 through 4-15 3
Nov. 1993 4-16 5
Sept. 1995 4-17 6
May 1997 4-18 through 4-19 3
Nov. 1993 4-20 and 4-21 5
Sept. 1995 4-22 through 4-35 3
Nov. 1993 Figures 4.8.2-1 through 4.8.2-20 1
Nov. 1992 5-1 3
Nov. 1993 A-1 through A-4 5
Sept. 1995 B-1 5
Sept. 1995 r\\
v v
Amendment 6 May 1997
,s e
Li SEISMIC CLASSIFICATION OF SYSTEMS AND COMPONENTS 4'5.1 SEISMIC CATEGORY I This category applies to structures, systems, and components that are necessary to ensures (a) the integrity of the RCPB, (b) the capability to shut down the reactor and maintain it in a safe shutdown condition, or (c) the
{
ability to prevent or mitigate the consequences of accidents that could result in potential offsite exposures comparable to the guideline exposures in 10 CFR, 100.
Seismic Category I components must remain operable and/or maintain structural integrity during and/or after an SSE in order to perform their safety functions.
The only remaining Design Basis Accidents are a fuel handling accident and a loss of forced cooling to the SFP.
Note that Trojan's licensing and design basic allows boiling of the water in the SFP.
To ensure that water remains in the SFP the integrity of the SFP walls, floor and liner must be maintained, and the fuel racks must maintain their integrity to ensure fuel geometry.
It is also necessary to ensure the ability to replace the water lost by boiling
\\
or evaporation, if normal cooling of the SFP is lost.
The structures, systems, and components of the Trojan Nuclear Planb, including their foundations and supports, designated as Category I include i
(1)
Control, Auxiliary and Fuel Building Complex.
(2)
SFP structure, including the fuel racks.
(3)
The fuel transfer tube.
4.5.2 SEISMIC CATEGORY II/I The Containment Structure and the Fuel Building Steel Superstructure are classified as Seismic Category II/I.
G' Amendment 6 4-17 May 1997