Category:INSPECTION REPORT
MONTHYEARML20216F1281999-09-0808 September 1999 Insp Rept 70-1113/99-05 on 990809-13.No Violations Noted. Major Areas Inspected:Rountine Unannounced Insp Involved Observation of Work Activities,Review of Selected Records ML20211L3001999-08-31031 August 1999 Insp Rept 70-1113/99-04 on 990726-0805.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Emergency Preparedness ML20211F2551999-08-25025 August 1999 Insp Rept 70-1113/99-202 on 990802-06.No Violations Noted. Major Areas Inspected:Implementation of GE Fire Protection Program Commitments Re Safe Plant Operations ML20210V2051999-08-13013 August 1999 Insp Rept 70-1113/99-03 on 990712-16.No Violations Noted. Major Areas Inspected:Environ Monitoring Program ML20195D4131999-06-0404 June 1999 Partially Withheld Insp Rept 70-1113/99-201 Conducted on 990510-14.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20203G4671999-02-0505 February 1999 Insp Rept 70-1113/99-01 on 990111-15.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Personnel in Area of Radiation Protection ML20202J1001999-01-29029 January 1999 Insp Rept 70-1113/99-02 on 990104-08.No Violations Noted. Major Areas Inspected:Plant Operations,Environ Protection & Training ML20155A8561998-09-30030 September 1998 Insp Rept 70-1113/98-05 on 980908-10.No Violations Noted. Major Areas Inspected:Licensee Program for Security & Safeguards ML20154C3421998-09-11011 September 1998 Insp Rept 70-1113/98-03 on 980817-21.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Transportation Program for Radioactive Matls & Radioactive Waste Mgt Program ML20154C1651998-09-0404 September 1998 Insp Rept 70-1113/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Assessment of Licensee Emergency Preparedness Program & State of Readiness for Responding to Various Postulated Accidents ML20151S8091998-09-0303 September 1998 Partially Withheld Insp Rept 70-1113/98-204 on 980810-14. Details Withheld (Ref 10CFR2.790) ML20237B4241998-08-0707 August 1998 Insp Rept 70-1113/98-02 on 980713-17.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations,Mgt Controls & Environ Protection Program ML20247H9921998-05-14014 May 1998 Insp Rept 70-1113/98-202 on 980420-24.Noncited Violation Noted.Major Areas Inspected:Implementation of GE Fire Protection Program ML20247H8581998-05-13013 May 1998 Insp Rept 70-1113/98-203 on 950504-08.Noncited Violations Noted.Major Areas Inspected:Review of Adequacy of Licensee Criticality Safety Program ML20216D3001998-04-0808 April 1998 Partially Withheld Insp Rept 70-1113/98-201 on 980309-13. No Violations Identified.Details Withheld Per 10CFR2.790 ML20217G1081998-03-26026 March 1998 Insp Rept 70-1113/98-01 on 980223-27.Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations & Training ML20199B4051998-01-0606 January 1998 Insp Rept 70-1113/97-08 on 971208-12.No Violations Noted. Major Areas Inspected:Licensee Conduct of Plant Operations & Maint ML20198H4351997-09-0404 September 1997 Partially Withheld Insp Rept 70-1113/97-203 on 970811-15, Per 10CFR2.790 ML20216B1821997-08-29029 August 1997 Insp Rept 70-1113/97-07 on 970714-18.No Violations Noted. Major Areas Inspected:Safety Operations,Radioactive Solid Waste Mgt,Transportation & Emergency Preparedness ML20141J7671997-08-11011 August 1997 Insp Rept 70-1113/97-06 on 970623-27.No Violations Noted. Major Areas Inspected:Status of Dry Conversion Facility, Including Completion of Const,Nuclear Criticality Safety, Chemical Safety & Radiation Protection ML20140E6571997-06-0606 June 1997 Insp Rept 70-1113/97-04 on 970326-28,0407-11 & 0429-0509. No Violations Noted.Major Areas Inspected:Status of New Dry Conversion Facility,Including Operations & Completion of Const ML20141K7021997-05-16016 May 1997 Insp Rept 70-1113/97-05 on 970414-18.No Violations Noted. Major Areas Inspected:Rp & FP Programs ML20138J8401997-04-18018 April 1997 Insp Rept 70-1113/97-03 on 970323-27.No Violations Noted. Major Areas Inspected:Environ Protection & Waste Mgt Programs & Status of New Dry Conversion Facility ML20137T5471997-04-0808 April 1997 Insp Rept 70-1113/97-02 on 970303-07 & 17-21.No Violations Noted.Major Areas Inspected:Operations,Training,Construction Completion & Training & Functional Testing of Sys ML20137P8141997-03-0707 March 1997 Insp Rept 70-1113/97-201 on 970303-07.Violation Noted.Rept Details Withheld ML20217D7331997-02-27027 February 1997 Insp Rept 70-1113/97-01 on 970127-31.No Violations Noted. Major Areas Inspected:Plant Operations,Management Organization & Controls,Maintenance/Surveillance,Training & Dcf Project ML20134G9851997-01-28028 January 1997 Special Insp Team Rept 70-1113/96-12 on 961204-08.Violations Noted.Major Areas Inspected:Circumstances Surrounding Tube Failure,Precursors to Event & Response to Event ML20134Q3121996-11-13013 November 1996 Insp Rept 70-1113/96-11 on 961014-18.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Maint/Surveillance & Dcf Project ML20134J4071996-11-0606 November 1996 Insp Rept 70-1113/96-10 on 960930-1003.Violations Noted. Major Areas Inspected:Elements of Internal Dose Monitoring & Controls Program Including Activities in Urinalysis Bioassy & Associated Air Sampling Program ML20134C4891996-09-0909 September 1996 Insp Rept 70-1113/96-07 on 960805-09.No Violations Noted. Major Areas Inspected:Review of Listed Physics Program Elements,Independent Radiation Safety Audit,External & Internal Exposure Controls & Organizational Change ML20058P6741993-12-0808 December 1993 Insp Rept 70-1113/93-11 on 931115-19.Non-cited Violations Identified.Major Areas Inspected:Mgt Controls,Organization, Nuclear Criticality Safety,Facility Changes,Maintenance, Operations & NRC Bulletins & Notices ML20058P5011993-12-0303 December 1993 Insp Rept 70-1113/93-10 on 931025-29 & 1101-05.No Violations Noted.Major Areas Inspected:Evaluation of Fuel Processing in Selected Favorable Geometry Operations & Nuclear Criticality Safety Aspects of Modifications Made to Conversion Lines ML20058Q2071993-10-17017 October 1993 Insp Rept 70-1113/93-09 on 930913-17.No Violations Noted. Major Areas Inspected:Licensee Radiation Protection Program Including Program Organization & Staffing,Procedures & Program Changes & Training ML20057E7331993-09-30030 September 1993 Insp Rept 70-1113/93-08 on 930907-10.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness & Which Included Listed Program Elements ML20057C1271993-09-20020 September 1993 Insp Rept 70-1113/93-202 on 930816-20.No Violations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment. Proprietary Insp Rept Details Withheld ML20057C2901993-09-15015 September 1993 Insp Rept 70-1113/93-07 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations,Fire Protection,Facility Changes & NRC Bulletins & Notices ML20056E2851993-08-12012 August 1993 Insp Rept 70-1113/93-06 on 930726-30.No Violations Noted. Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Maint & Fire Protection ML20056F3711993-08-10010 August 1993 Insp Rept 70-1113/93-05 on 930712-16.No Violations Noted. Major Areas Inspected:Radioactive Effluents,Environ Protection & Transportation of Radioactive Matl ML20128G4351993-02-0202 February 1993 Insp Rept 70-1113/93-01 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Changes,Facility Operations & follow-up of Previously Identified Items ML20128C0081992-11-23023 November 1992 Insp Rept 70-1113/92-15 on 921013-16.No Violations Noted. Major Areas Inspected:Emergency Facilities,Equipment & Implementing Procedures & Coordination of Emergency Planning W/Offsite Support Agencies ML20128C9151992-11-23023 November 1992 Insp Rept 70-1113/92-17 on 921109-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Operations,Facility Changes,Followup on Previously Identified Items & Current Issues ML20062H4231990-11-19019 November 1990 Insp Rept 70-1113/90-11 on 900924-28.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review & Followup on 10CFR21 Reportable Items ML20059N3391990-09-28028 September 1990 Insp Rept 70-1113/90-08 on 900827-31.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt, Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246C0641989-08-0909 August 1989 Partially Withheld Insp Rept 70-1113/89-10 on 890718-19 (Ref 10CFR2.790).Violations Re Controlled Access Area Noted But Not Cited.Major Areas Inspected:Physical Protection of Low Enriched Nuclear Matl ML20245E6791989-08-0303 August 1989 Partially Withheld Insp Rept 70-1113/89-09 on 890626-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys & Measurement Controls ML20248C1411989-07-27027 July 1989 Insp Rept 70-1113/89-05 on 890522-26 & 0612-15.Violations Noted.Major Areas Inspected:Licensee Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA, & Review of Previously Identified Inspector Followup Items ML20246E7181989-06-29029 June 1989 Insp Rept 70-1113/89-06 on 890605-09.No Violations & Deviations Noted.Major Areas Inspected:Emergency Preparedness,Radiological Contingency & Emergency Plan.Two Drill Weaknesses Identified ML20246C0611989-06-27027 June 1989 Insp Rept 70-1113/89-08 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing ML20244D8301989-05-25025 May 1989 Insp Rept 70-1113/89-04 on 890424-28.Non-cited Violation Identified.No Deviations Noted.Major Areas Inspected: Radwaste Mgt,Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246J7991989-05-0404 May 1989 Insp Rept 70-1113/89-03 on 890327-31.No Violations or Deviations Noted.Major Areas Inspected:Previously Identified Fire Protection/Prevention Program Findings from Oct 1986 Operational Safety Assessment Insp 1999-09-08
[Table view] Category:MANUFACTURER/VENDOR/ENGINEER
MONTHYEARML20059N3391990-09-28028 September 1990 Insp Rept 70-1113/90-08 on 900827-31.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt, Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246C0641989-08-0909 August 1989 Partially Withheld Insp Rept 70-1113/89-10 on 890718-19 (Ref 10CFR2.790).Violations Re Controlled Access Area Noted But Not Cited.Major Areas Inspected:Physical Protection of Low Enriched Nuclear Matl ML20245E6791989-08-0303 August 1989 Partially Withheld Insp Rept 70-1113/89-09 on 890626-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys & Measurement Controls ML20248C1411989-07-27027 July 1989 Insp Rept 70-1113/89-05 on 890522-26 & 0612-15.Violations Noted.Major Areas Inspected:Licensee Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA, & Review of Previously Identified Inspector Followup Items ML20246E7181989-06-29029 June 1989 Insp Rept 70-1113/89-06 on 890605-09.No Violations & Deviations Noted.Major Areas Inspected:Emergency Preparedness,Radiological Contingency & Emergency Plan.Two Drill Weaknesses Identified ML20246C0611989-06-27027 June 1989 Insp Rept 70-1113/89-08 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing ML20246J7991989-05-0404 May 1989 Insp Rept 70-1113/89-03 on 890327-31.No Violations or Deviations Noted.Major Areas Inspected:Previously Identified Fire Protection/Prevention Program Findings from Oct 1986 Operational Safety Assessment Insp ML20247F0161989-03-10010 March 1989 Insp Rept 70-1113/89-02 on 890123-27.No Violations or Deviations Noted.Major Areas Inspected:Mgt Organization Controls,Training & Retraining,Nuclear Criticality Safety, Operations Review,Maint & Surveillance Testing ML20247M6541989-03-0808 March 1989 Partially Withheld Insp Rept 70-1113/89-01 on 890109-13 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Measurement Sys & Matl Control & Accountability Sys Mgt & Assessment ML20206B4491988-11-0707 November 1988 Insp Rept 70-1113/88-17 on 880926-30.Violations & Deviations Noted.Major Areas Inspected:Radwaste Mgt & Radiological Environ Monitoring ML20206C2761988-10-28028 October 1988 Partially Withheld Team Insp Rept 70-1113/88-13 on 880926-30 (Ref 10CFR2.790).One Violation Noted.Major Areas Inspected: Licensee Nuclear Matl Control & Accounting Program Used to Achieve Performance Objectives for Period Ending 880801 ML20195C1581988-10-19019 October 1988 Insp Rept 70-1113/88-16 on 880919-22.No Violations or Deviations Noted.Major Areas Inspected:Mgt Organization & Controls,Training,Nuclear Criticality Safety & Operations ML20195C0111988-10-18018 October 1988 Insp Rept 70-1113/88-15 on 880919-23.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness ML20155B9121988-09-28028 September 1988 Partially Withheld Insp Rept 70-1113/88-12 on 880822-26. Violations Noted.Major Areas Inspected:Export Shipments & Measurements ML20154A8391988-08-29029 August 1988 Partially Withheld Insp Rept 70-1113/88-11 on 880725-0802 (Ref 10CFR2.790).No Deviations or Violations Noted.Major Ares Inspected:Physical Inventory,Independent Insp Effort & Actions on Previous Findings ML20151S4481988-07-27027 July 1988 Insp Rept 70-1113/88-08 on 880523-27.Violations Noted.Major Areas Inspected:Radiation Protection Program Areas,Including Radiation Protection Staff Organization & Training,Solid Radwaste Issues & Transportation Activities ML20154N6231988-05-18018 May 1988 Insp Rept 70-1113/88-06 on 880411-15.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt & Radiological Environ Monitoring ML20151V3321988-04-19019 April 1988 Partially Withheld Insp Rept 70-1113/88-03 on 880314-18 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Implementation of Us/Iaea Agreement at GE Fuel Fabrication Facility ML20151P2311988-04-15015 April 1988 Partially Withheld Insp Rept 70-1113/88-05 on 880328-30 Ref (10CFR2.790(d) & 73.21).No Violations or Deviations Noted.Allegation Could Not Be Substantiated ML20236R6281987-11-16016 November 1987 Revised Page 9 to Insp Rept 70-1113/87-12 ML20236E4301987-10-16016 October 1987 Partially Withheld Insp Rept 70-1113/87-14 on 870908-28 (Ref 10CFR2.790(d)).No Violations or Deviations Noted.Major Areas Inspected:Statistical Analysis of U Concentration Measurements of U Dioxide Powder by Util & NRC Contractor ML20235F4141987-09-18018 September 1987 Insp Rept 70-1113/87-12 on 870824-28.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt,Environ Monitoring & Confirmatory Measurements ML20235H4571987-07-0707 July 1987 Insp Rept 70-1113/87-08 on 870608-12.Major Areas Inspected: Radiation Protection Program,Transportation of Radioactive Matls,Solid Radwaste Mgt,Followup of Previous Enforcement Issues,Allegations & IE Info Notices ML20235M1131987-06-30030 June 1987 Partially Withheld Insp Rept 70-1113/87-09 on 870615-18 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Followup on Inspector Identified Items,Facility Organization & Mgt Controls & Measurement Sys ML20214T7921987-05-29029 May 1987 Partially Withheld Insp Rept 70-1113/87-05 on 870504-08 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Failure to Properly Approve Procedure Prior to Use ML20214W1081987-05-22022 May 1987 Partially Withheld Insp Rept 70-1113/87-07 on 870427-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Exam of Measurement Differences Between GE & New Brunswick Lab Associated w/UO2 Powder ML20209E1571987-04-22022 April 1987 Partially Withheld Insp Rept 70-1113/87-04 on 870323-27 (Ref 10CFR2.790 & 73.21).No Violation or Deviation Noted.Major Areas Inspected:Investigation of GE UO2 Powder Measurements ML20209E1001987-04-0909 April 1987 Partially Withheld Insp Rept 70-1113/87-03 on 870316-20 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Followup on Inspector Identified Items & Measurement Control & Statistics ML20207T7341987-02-17017 February 1987 Partially Withheld Insp Rept 70-1113/87-01 on 870112-16 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Measurement Sys,Facility Organization & Mgt Controls ML20211C7391987-02-10010 February 1987 Partially Withheld Insp Rept 70-1113/87-02 on 870120-23 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Measurements & Independent Insp Effort ML20214W9871986-11-26026 November 1986 Partially Withheld Insp Rept 70-1113/86-23 on 861014-17 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Measurement Sys & Followup on Previous Violations & Insp Findings ML20207A8831986-10-29029 October 1986 Insp Rept 70-1113/86-19 on 860929-1003.Violations Noted: Failure to Follow Procedures,Failure to Calibr Airline Pressure Gauges or Flow Measuring Devices & Failure to Meet DOT Empty Radioactive Matl Package Shipping Requirements ML20197A7691986-10-0909 October 1986 Insp Rept 70-1113/86-18 on 860926.No Violations or Deviations Noted.Major Areas Inspected:Selected Areas of Emergency Preparedness Program ML20205E0941986-08-0606 August 1986 Partially Withheld Insp Rept 70-1113/86-16 on 860721-25 (Ref 10CFR2.790 & 73.21).Violation Noted:Failure to Submit Matl Status Rept ML20211N0431986-08-0505 August 1986 Partially Withheld Insp Rept 70-1113/86-16 on 860721-25 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Failure to Submit Matl Status Rept ML20211M9841986-07-30030 July 1986 Partially Withheld Insp Rept 70-1113/86-15 on 860714-18 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Failure to Follow Approved Plant Procedures ML20207K4371986-07-14014 July 1986 Partially Withheld Insp Rept 70-1113/86-13 on 860630-0702 (Ref 10CFR2.790).No Violation Noted.Major Areas Inspected: Licensee Program for Physical Protection of SNM of Low Strategic Significance ML20211N8691986-07-14014 July 1986 Physical Security Insp Rept 70-1113/86-13 on 860630-0702. No Violations Noted.Major Areas Inspected:Licensee Program for Physical Protection of SNM of Low Strategic Significance ML20199J3761986-06-17017 June 1986 Insp Rept 70-1113/86-11 on 860602-06.No Noncompliance Noted. Major Areas Inspected:Measurements,Export Shipment & Followup on Previous Insp Findings.Details Withheld (Ref 10CFR2.790) ML20211M9061986-06-17017 June 1986 Partially Withheld Insp Rept 70-1113/86-11 on 860602-06 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Measurements,Export Shipment & Followup on Previous Insp Findings ML20211M8561986-06-0303 June 1986 Partially Withheld Insp Rept 70-1113/86-09 on 860428-0502 (Ref 10CFR2.790(d) & 73.21).Violation Noted:Failure to Correctly Calculate Limit of Error Associated W/Inventory Difference ML20205P7791986-04-28028 April 1986 Partially Withheld Insp Rept 70-1113/86-07 on 860324-28 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Export Shipment,Measurements & Followup on Previous Insp Findings ML20211M7911986-04-28028 April 1986 Partially Withheld Details of Insp Rept 70-1113/86-07 on 860324-28 (Ref 10CFR2.790(d) 73.21).No Violations or Deviations Noted.Major Areas Inspected:Export Shipmment, Measurements & Followup on Previous Insp Findings ML20203P1091986-04-25025 April 1986 Insp Rept 70-1113/86-08 on 860408.No Violations or Deviations Identified.Major Areas Inspected:Confirmatory Radiation & Contamination Surveys Performed as Closeout Insp of Storage Facility Leased by Eastern Distribution,Inc ML20203N9271986-04-10010 April 1986 Partially Withheld Insp Rept 70-1113/86-05 on 860317-21 (Ref 10CFR73.21 & 2.790).No Violation or Deviation Noted. Major Areas Inspected:Facility Operations & Internal Controls,Records & Repts ML20141E4731986-04-0808 April 1986 Partially Withheld Insp Rept 70-1113/86-06 on 860317-21 (Ref 10CFR2.790 & 73.21).No Violation Noted.Major Areas Inspected:Measurement Control & Statistics ML20211M7561986-04-0808 April 1986 Partially Withheld Insp Rept 70-1113/86-06 on 860317-21 (Ref 10CFR2.790(d) & 73.21).No Violations or Deviations. Major Areas Inspected:Measurement Control & Statistics & Licensee Action on Previously Identified Violations ML20155A0191986-03-31031 March 1986 Insp Rept 70-1113/86-03 on 860218-21.No Violations or Deviations Noted.Major Areas Inspected:Followup on Conversion Reactor Event,Nuclear Criticality Safety, Operations Review & Procedures Re UF6 Cylinders ML20205M2031986-03-28028 March 1986 Insp Rept 70-1113/86-02 on 860224-28.No Violation or Deviation Noted.Major Areas Inspected:Emergency Preparedness ML20205M5531986-03-27027 March 1986 Insp Rept 70-1113/86-01 on 860203-05.Violations Noted:Eight HEPA Filters Improperly Installed,Resulting in Degradation of Rated Efficiency of Gaseous Effluent Treatment Sys & Failure to Approve Transportation Procedures 1990-09-28
[Table view] Category:INSPECTION REPORT
MONTHYEARML20216F1281999-09-0808 September 1999 Insp Rept 70-1113/99-05 on 990809-13.No Violations Noted. Major Areas Inspected:Rountine Unannounced Insp Involved Observation of Work Activities,Review of Selected Records ML20211L3001999-08-31031 August 1999 Insp Rept 70-1113/99-04 on 990726-0805.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Emergency Preparedness ML20211F2551999-08-25025 August 1999 Insp Rept 70-1113/99-202 on 990802-06.No Violations Noted. Major Areas Inspected:Implementation of GE Fire Protection Program Commitments Re Safe Plant Operations ML20210V2051999-08-13013 August 1999 Insp Rept 70-1113/99-03 on 990712-16.No Violations Noted. Major Areas Inspected:Environ Monitoring Program ML20195D4131999-06-0404 June 1999 Partially Withheld Insp Rept 70-1113/99-201 Conducted on 990510-14.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20203G4671999-02-0505 February 1999 Insp Rept 70-1113/99-01 on 990111-15.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Personnel in Area of Radiation Protection ML20202J1001999-01-29029 January 1999 Insp Rept 70-1113/99-02 on 990104-08.No Violations Noted. Major Areas Inspected:Plant Operations,Environ Protection & Training ML20155A8561998-09-30030 September 1998 Insp Rept 70-1113/98-05 on 980908-10.No Violations Noted. Major Areas Inspected:Licensee Program for Security & Safeguards ML20154C3421998-09-11011 September 1998 Insp Rept 70-1113/98-03 on 980817-21.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Transportation Program for Radioactive Matls & Radioactive Waste Mgt Program ML20154C1651998-09-0404 September 1998 Insp Rept 70-1113/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Assessment of Licensee Emergency Preparedness Program & State of Readiness for Responding to Various Postulated Accidents ML20151S8091998-09-0303 September 1998 Partially Withheld Insp Rept 70-1113/98-204 on 980810-14. Details Withheld (Ref 10CFR2.790) ML20237B4241998-08-0707 August 1998 Insp Rept 70-1113/98-02 on 980713-17.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations,Mgt Controls & Environ Protection Program ML20247H9921998-05-14014 May 1998 Insp Rept 70-1113/98-202 on 980420-24.Noncited Violation Noted.Major Areas Inspected:Implementation of GE Fire Protection Program ML20247H8581998-05-13013 May 1998 Insp Rept 70-1113/98-203 on 950504-08.Noncited Violations Noted.Major Areas Inspected:Review of Adequacy of Licensee Criticality Safety Program ML20216D3001998-04-0808 April 1998 Partially Withheld Insp Rept 70-1113/98-201 on 980309-13. No Violations Identified.Details Withheld Per 10CFR2.790 ML20217G1081998-03-26026 March 1998 Insp Rept 70-1113/98-01 on 980223-27.Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations & Training ML20199B4051998-01-0606 January 1998 Insp Rept 70-1113/97-08 on 971208-12.No Violations Noted. Major Areas Inspected:Licensee Conduct of Plant Operations & Maint ML20198H4351997-09-0404 September 1997 Partially Withheld Insp Rept 70-1113/97-203 on 970811-15, Per 10CFR2.790 ML20216B1821997-08-29029 August 1997 Insp Rept 70-1113/97-07 on 970714-18.No Violations Noted. Major Areas Inspected:Safety Operations,Radioactive Solid Waste Mgt,Transportation & Emergency Preparedness ML20141J7671997-08-11011 August 1997 Insp Rept 70-1113/97-06 on 970623-27.No Violations Noted. Major Areas Inspected:Status of Dry Conversion Facility, Including Completion of Const,Nuclear Criticality Safety, Chemical Safety & Radiation Protection ML20140E6571997-06-0606 June 1997 Insp Rept 70-1113/97-04 on 970326-28,0407-11 & 0429-0509. No Violations Noted.Major Areas Inspected:Status of New Dry Conversion Facility,Including Operations & Completion of Const ML20141K7021997-05-16016 May 1997 Insp Rept 70-1113/97-05 on 970414-18.No Violations Noted. Major Areas Inspected:Rp & FP Programs ML20138J8401997-04-18018 April 1997 Insp Rept 70-1113/97-03 on 970323-27.No Violations Noted. Major Areas Inspected:Environ Protection & Waste Mgt Programs & Status of New Dry Conversion Facility ML20137T5471997-04-0808 April 1997 Insp Rept 70-1113/97-02 on 970303-07 & 17-21.No Violations Noted.Major Areas Inspected:Operations,Training,Construction Completion & Training & Functional Testing of Sys ML20137P8141997-03-0707 March 1997 Insp Rept 70-1113/97-201 on 970303-07.Violation Noted.Rept Details Withheld ML20217D7331997-02-27027 February 1997 Insp Rept 70-1113/97-01 on 970127-31.No Violations Noted. Major Areas Inspected:Plant Operations,Management Organization & Controls,Maintenance/Surveillance,Training & Dcf Project ML20134G9851997-01-28028 January 1997 Special Insp Team Rept 70-1113/96-12 on 961204-08.Violations Noted.Major Areas Inspected:Circumstances Surrounding Tube Failure,Precursors to Event & Response to Event ML20134Q3121996-11-13013 November 1996 Insp Rept 70-1113/96-11 on 961014-18.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Maint/Surveillance & Dcf Project ML20134J4071996-11-0606 November 1996 Insp Rept 70-1113/96-10 on 960930-1003.Violations Noted. Major Areas Inspected:Elements of Internal Dose Monitoring & Controls Program Including Activities in Urinalysis Bioassy & Associated Air Sampling Program ML20134C4891996-09-0909 September 1996 Insp Rept 70-1113/96-07 on 960805-09.No Violations Noted. Major Areas Inspected:Review of Listed Physics Program Elements,Independent Radiation Safety Audit,External & Internal Exposure Controls & Organizational Change ML20058P6741993-12-0808 December 1993 Insp Rept 70-1113/93-11 on 931115-19.Non-cited Violations Identified.Major Areas Inspected:Mgt Controls,Organization, Nuclear Criticality Safety,Facility Changes,Maintenance, Operations & NRC Bulletins & Notices ML20058P5011993-12-0303 December 1993 Insp Rept 70-1113/93-10 on 931025-29 & 1101-05.No Violations Noted.Major Areas Inspected:Evaluation of Fuel Processing in Selected Favorable Geometry Operations & Nuclear Criticality Safety Aspects of Modifications Made to Conversion Lines ML20058Q2071993-10-17017 October 1993 Insp Rept 70-1113/93-09 on 930913-17.No Violations Noted. Major Areas Inspected:Licensee Radiation Protection Program Including Program Organization & Staffing,Procedures & Program Changes & Training ML20057E7331993-09-30030 September 1993 Insp Rept 70-1113/93-08 on 930907-10.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness & Which Included Listed Program Elements ML20057C1271993-09-20020 September 1993 Insp Rept 70-1113/93-202 on 930816-20.No Violations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment. Proprietary Insp Rept Details Withheld ML20057C2901993-09-15015 September 1993 Insp Rept 70-1113/93-07 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations,Fire Protection,Facility Changes & NRC Bulletins & Notices ML20056E2851993-08-12012 August 1993 Insp Rept 70-1113/93-06 on 930726-30.No Violations Noted. Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Maint & Fire Protection ML20056F3711993-08-10010 August 1993 Insp Rept 70-1113/93-05 on 930712-16.No Violations Noted. Major Areas Inspected:Radioactive Effluents,Environ Protection & Transportation of Radioactive Matl ML20128G4351993-02-0202 February 1993 Insp Rept 70-1113/93-01 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Changes,Facility Operations & follow-up of Previously Identified Items ML20128C0081992-11-23023 November 1992 Insp Rept 70-1113/92-15 on 921013-16.No Violations Noted. Major Areas Inspected:Emergency Facilities,Equipment & Implementing Procedures & Coordination of Emergency Planning W/Offsite Support Agencies ML20128C9151992-11-23023 November 1992 Insp Rept 70-1113/92-17 on 921109-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Operations,Facility Changes,Followup on Previously Identified Items & Current Issues ML20062H4231990-11-19019 November 1990 Insp Rept 70-1113/90-11 on 900924-28.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review & Followup on 10CFR21 Reportable Items ML20059N3391990-09-28028 September 1990 Insp Rept 70-1113/90-08 on 900827-31.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt, Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246C0641989-08-0909 August 1989 Partially Withheld Insp Rept 70-1113/89-10 on 890718-19 (Ref 10CFR2.790).Violations Re Controlled Access Area Noted But Not Cited.Major Areas Inspected:Physical Protection of Low Enriched Nuclear Matl ML20245E6791989-08-0303 August 1989 Partially Withheld Insp Rept 70-1113/89-09 on 890626-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys & Measurement Controls ML20248C1411989-07-27027 July 1989 Insp Rept 70-1113/89-05 on 890522-26 & 0612-15.Violations Noted.Major Areas Inspected:Licensee Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA, & Review of Previously Identified Inspector Followup Items ML20246E7181989-06-29029 June 1989 Insp Rept 70-1113/89-06 on 890605-09.No Violations & Deviations Noted.Major Areas Inspected:Emergency Preparedness,Radiological Contingency & Emergency Plan.Two Drill Weaknesses Identified ML20246C0611989-06-27027 June 1989 Insp Rept 70-1113/89-08 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing ML20244D8301989-05-25025 May 1989 Insp Rept 70-1113/89-04 on 890424-28.Non-cited Violation Identified.No Deviations Noted.Major Areas Inspected: Radwaste Mgt,Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246J7991989-05-0404 May 1989 Insp Rept 70-1113/89-03 on 890327-31.No Violations or Deviations Noted.Major Areas Inspected:Previously Identified Fire Protection/Prevention Program Findings from Oct 1986 Operational Safety Assessment Insp 1999-09-08
[Table view] Category:NRC-GENERATED
MONTHYEARML20216F1281999-09-0808 September 1999 Insp Rept 70-1113/99-05 on 990809-13.No Violations Noted. Major Areas Inspected:Rountine Unannounced Insp Involved Observation of Work Activities,Review of Selected Records ML20211L3001999-08-31031 August 1999 Insp Rept 70-1113/99-04 on 990726-0805.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Emergency Preparedness ML20211F2551999-08-25025 August 1999 Insp Rept 70-1113/99-202 on 990802-06.No Violations Noted. Major Areas Inspected:Implementation of GE Fire Protection Program Commitments Re Safe Plant Operations ML20210V2051999-08-13013 August 1999 Insp Rept 70-1113/99-03 on 990712-16.No Violations Noted. Major Areas Inspected:Environ Monitoring Program ML20195D4131999-06-0404 June 1999 Partially Withheld Insp Rept 70-1113/99-201 Conducted on 990510-14.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20203G4671999-02-0505 February 1999 Insp Rept 70-1113/99-01 on 990111-15.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Personnel in Area of Radiation Protection ML20202J1001999-01-29029 January 1999 Insp Rept 70-1113/99-02 on 990104-08.No Violations Noted. Major Areas Inspected:Plant Operations,Environ Protection & Training ML20155A8561998-09-30030 September 1998 Insp Rept 70-1113/98-05 on 980908-10.No Violations Noted. Major Areas Inspected:Licensee Program for Security & Safeguards ML20154C3421998-09-11011 September 1998 Insp Rept 70-1113/98-03 on 980817-21.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Transportation Program for Radioactive Matls & Radioactive Waste Mgt Program ML20154C1651998-09-0404 September 1998 Insp Rept 70-1113/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Assessment of Licensee Emergency Preparedness Program & State of Readiness for Responding to Various Postulated Accidents ML20151S8091998-09-0303 September 1998 Partially Withheld Insp Rept 70-1113/98-204 on 980810-14. Details Withheld (Ref 10CFR2.790) ML20237B4241998-08-0707 August 1998 Insp Rept 70-1113/98-02 on 980713-17.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations,Mgt Controls & Environ Protection Program ML20247H9921998-05-14014 May 1998 Insp Rept 70-1113/98-202 on 980420-24.Noncited Violation Noted.Major Areas Inspected:Implementation of GE Fire Protection Program ML20247H8581998-05-13013 May 1998 Insp Rept 70-1113/98-203 on 950504-08.Noncited Violations Noted.Major Areas Inspected:Review of Adequacy of Licensee Criticality Safety Program ML20216D3001998-04-0808 April 1998 Partially Withheld Insp Rept 70-1113/98-201 on 980309-13. No Violations Identified.Details Withheld Per 10CFR2.790 ML20217G1081998-03-26026 March 1998 Insp Rept 70-1113/98-01 on 980223-27.Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations & Training ML20199B4051998-01-0606 January 1998 Insp Rept 70-1113/97-08 on 971208-12.No Violations Noted. Major Areas Inspected:Licensee Conduct of Plant Operations & Maint ML20198H4351997-09-0404 September 1997 Partially Withheld Insp Rept 70-1113/97-203 on 970811-15, Per 10CFR2.790 ML20216B1821997-08-29029 August 1997 Insp Rept 70-1113/97-07 on 970714-18.No Violations Noted. Major Areas Inspected:Safety Operations,Radioactive Solid Waste Mgt,Transportation & Emergency Preparedness ML20141J7671997-08-11011 August 1997 Insp Rept 70-1113/97-06 on 970623-27.No Violations Noted. Major Areas Inspected:Status of Dry Conversion Facility, Including Completion of Const,Nuclear Criticality Safety, Chemical Safety & Radiation Protection ML20140E6571997-06-0606 June 1997 Insp Rept 70-1113/97-04 on 970326-28,0407-11 & 0429-0509. No Violations Noted.Major Areas Inspected:Status of New Dry Conversion Facility,Including Operations & Completion of Const ML20141K7021997-05-16016 May 1997 Insp Rept 70-1113/97-05 on 970414-18.No Violations Noted. Major Areas Inspected:Rp & FP Programs ML20138J8401997-04-18018 April 1997 Insp Rept 70-1113/97-03 on 970323-27.No Violations Noted. Major Areas Inspected:Environ Protection & Waste Mgt Programs & Status of New Dry Conversion Facility ML20137T5471997-04-0808 April 1997 Insp Rept 70-1113/97-02 on 970303-07 & 17-21.No Violations Noted.Major Areas Inspected:Operations,Training,Construction Completion & Training & Functional Testing of Sys ML20137P8141997-03-0707 March 1997 Insp Rept 70-1113/97-201 on 970303-07.Violation Noted.Rept Details Withheld ML20217D7331997-02-27027 February 1997 Insp Rept 70-1113/97-01 on 970127-31.No Violations Noted. Major Areas Inspected:Plant Operations,Management Organization & Controls,Maintenance/Surveillance,Training & Dcf Project ML20134G9851997-01-28028 January 1997 Special Insp Team Rept 70-1113/96-12 on 961204-08.Violations Noted.Major Areas Inspected:Circumstances Surrounding Tube Failure,Precursors to Event & Response to Event ML20134Q3121996-11-13013 November 1996 Insp Rept 70-1113/96-11 on 961014-18.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Maint/Surveillance & Dcf Project ML20134J4071996-11-0606 November 1996 Insp Rept 70-1113/96-10 on 960930-1003.Violations Noted. Major Areas Inspected:Elements of Internal Dose Monitoring & Controls Program Including Activities in Urinalysis Bioassy & Associated Air Sampling Program ML20134C4891996-09-0909 September 1996 Insp Rept 70-1113/96-07 on 960805-09.No Violations Noted. Major Areas Inspected:Review of Listed Physics Program Elements,Independent Radiation Safety Audit,External & Internal Exposure Controls & Organizational Change ML20058P6741993-12-0808 December 1993 Insp Rept 70-1113/93-11 on 931115-19.Non-cited Violations Identified.Major Areas Inspected:Mgt Controls,Organization, Nuclear Criticality Safety,Facility Changes,Maintenance, Operations & NRC Bulletins & Notices ML20058P5011993-12-0303 December 1993 Insp Rept 70-1113/93-10 on 931025-29 & 1101-05.No Violations Noted.Major Areas Inspected:Evaluation of Fuel Processing in Selected Favorable Geometry Operations & Nuclear Criticality Safety Aspects of Modifications Made to Conversion Lines ML20058Q2071993-10-17017 October 1993 Insp Rept 70-1113/93-09 on 930913-17.No Violations Noted. Major Areas Inspected:Licensee Radiation Protection Program Including Program Organization & Staffing,Procedures & Program Changes & Training ML20057E7331993-09-30030 September 1993 Insp Rept 70-1113/93-08 on 930907-10.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness & Which Included Listed Program Elements ML20057C1271993-09-20020 September 1993 Insp Rept 70-1113/93-202 on 930816-20.No Violations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment. Proprietary Insp Rept Details Withheld ML20057C2901993-09-15015 September 1993 Insp Rept 70-1113/93-07 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations,Fire Protection,Facility Changes & NRC Bulletins & Notices ML20056E2851993-08-12012 August 1993 Insp Rept 70-1113/93-06 on 930726-30.No Violations Noted. Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Maint & Fire Protection ML20056F3711993-08-10010 August 1993 Insp Rept 70-1113/93-05 on 930712-16.No Violations Noted. Major Areas Inspected:Radioactive Effluents,Environ Protection & Transportation of Radioactive Matl ML20128G4351993-02-0202 February 1993 Insp Rept 70-1113/93-01 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Changes,Facility Operations & follow-up of Previously Identified Items ML20128C0081992-11-23023 November 1992 Insp Rept 70-1113/92-15 on 921013-16.No Violations Noted. Major Areas Inspected:Emergency Facilities,Equipment & Implementing Procedures & Coordination of Emergency Planning W/Offsite Support Agencies ML20128C9151992-11-23023 November 1992 Insp Rept 70-1113/92-17 on 921109-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Operations,Facility Changes,Followup on Previously Identified Items & Current Issues ML20062H4231990-11-19019 November 1990 Insp Rept 70-1113/90-11 on 900924-28.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review & Followup on 10CFR21 Reportable Items ML20059N3391990-09-28028 September 1990 Insp Rept 70-1113/90-08 on 900827-31.No Violations or Deviations Noted.Major Areas Inspected:Radwaste Mgt, Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246C0641989-08-0909 August 1989 Partially Withheld Insp Rept 70-1113/89-10 on 890718-19 (Ref 10CFR2.790).Violations Re Controlled Access Area Noted But Not Cited.Major Areas Inspected:Physical Protection of Low Enriched Nuclear Matl ML20245E6791989-08-0303 August 1989 Partially Withheld Insp Rept 70-1113/89-09 on 890626-30 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment,Internal Controls,Measurement Sys & Measurement Controls ML20248C1411989-07-27027 July 1989 Insp Rept 70-1113/89-05 on 890522-26 & 0612-15.Violations Noted.Major Areas Inspected:Licensee Radiation Protection Programs for Assuring Personnel Exposures Maintained ALARA, & Review of Previously Identified Inspector Followup Items ML20246E7181989-06-29029 June 1989 Insp Rept 70-1113/89-06 on 890605-09.No Violations & Deviations Noted.Major Areas Inspected:Emergency Preparedness,Radiological Contingency & Emergency Plan.Two Drill Weaknesses Identified ML20246C0611989-06-27027 June 1989 Insp Rept 70-1113/89-08 on 890530-0602.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations Review,Maint & Surveillance Testing ML20244D8301989-05-25025 May 1989 Insp Rept 70-1113/89-04 on 890424-28.Non-cited Violation Identified.No Deviations Noted.Major Areas Inspected: Radwaste Mgt,Radioactive Effluent Sampling,Monitoring & Analysis & Radiological Environ Monitoring ML20246J7991989-05-0404 May 1989 Insp Rept 70-1113/89-03 on 890327-31.No Violations or Deviations Noted.Major Areas Inspected:Previously Identified Fire Protection/Prevention Program Findings from Oct 1986 Operational Safety Assessment Insp 1999-09-08
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARML20216F1281999-09-0808 September 1999 Insp Rept 70-1113/99-05 on 990809-13.No Violations Noted. Major Areas Inspected:Rountine Unannounced Insp Involved Observation of Work Activities,Review of Selected Records ML20211L3001999-08-31031 August 1999 Insp Rept 70-1113/99-04 on 990726-0805.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Controls,Maint/Surveillance & Emergency Preparedness PNO-II-99-033, on 990830,Hurricane Dennis Was Located Approx 72 Miles Southeast of Bsep.No Significant Damage Has Been Sustained at Site.Ge Facility Suspended Fuel Fabrication Processes & No Significant Damage Was Sustained1999-08-30030 August 1999 PNO-II-99-033:on 990830,Hurricane Dennis Was Located Approx 72 Miles Southeast of Bsep.No Significant Damage Has Been Sustained at Site.Ge Facility Suspended Fuel Fabrication Processes & No Significant Damage Was Sustained ML20211F2551999-08-25025 August 1999 Insp Rept 70-1113/99-202 on 990802-06.No Violations Noted. Major Areas Inspected:Implementation of GE Fire Protection Program Commitments Re Safe Plant Operations ML20210V2051999-08-13013 August 1999 Insp Rept 70-1113/99-03 on 990712-16.No Violations Noted. Major Areas Inspected:Environ Monitoring Program ML20195D4131999-06-0404 June 1999 Partially Withheld Insp Rept 70-1113/99-201 Conducted on 990510-14.No Violations Noted.Details Withheld,Per 10CFR2.790 ML20203G4671999-02-0505 February 1999 Insp Rept 70-1113/99-01 on 990111-15.No Violations Noted. Major Areas Inspected:Observation of Work Activities,Review of Selected Records & Interviews with Personnel in Area of Radiation Protection ML20202J1001999-01-29029 January 1999 Insp Rept 70-1113/99-02 on 990104-08.No Violations Noted. Major Areas Inspected:Plant Operations,Environ Protection & Training ML20155A8561998-09-30030 September 1998 Insp Rept 70-1113/98-05 on 980908-10.No Violations Noted. Major Areas Inspected:Licensee Program for Security & Safeguards ML20154C3421998-09-11011 September 1998 Insp Rept 70-1113/98-03 on 980817-21.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Transportation Program for Radioactive Matls & Radioactive Waste Mgt Program ML20154C1651998-09-0404 September 1998 Insp Rept 70-1113/98-04 on 980810-14.No Violations Noted. Major Areas Inspected:Assessment of Licensee Emergency Preparedness Program & State of Readiness for Responding to Various Postulated Accidents ML20151S8091998-09-0303 September 1998 Partially Withheld Insp Rept 70-1113/98-204 on 980810-14. Details Withheld (Ref 10CFR2.790) ML20237B4241998-08-0707 August 1998 Insp Rept 70-1113/98-02 on 980713-17.No Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations,Mgt Controls & Environ Protection Program ML20247H9921998-05-14014 May 1998 Insp Rept 70-1113/98-202 on 980420-24.Noncited Violation Noted.Major Areas Inspected:Implementation of GE Fire Protection Program ML20247H8581998-05-13013 May 1998 Insp Rept 70-1113/98-203 on 950504-08.Noncited Violations Noted.Major Areas Inspected:Review of Adequacy of Licensee Criticality Safety Program ML20216D3001998-04-0808 April 1998 Partially Withheld Insp Rept 70-1113/98-201 on 980309-13. No Violations Identified.Details Withheld Per 10CFR2.790 ML20217G0971998-03-26026 March 1998 Notice of Violation from Insp on 980223-27.Violation Noted: on 980226,three Unscanned Solvent Drums Stored at Distances of Four to Ten Feet from Other Drum Arrays ML20217G1081998-03-26026 March 1998 Insp Rept 70-1113/98-01 on 980223-27.Violations Noted. Major Areas Inspected:Evaluation of Licensee Conduct of Plant Operations & Training PNO-II-98-016, on 980316,licensee Declared Alert Due to Fire in Dumpster Located Outside Fuels Mfg Operations Bldg. Extinguished Fire,Inspected Roof & Posted Hourly Fire Watch. Licensee Will Investigate Root Causes & CAs to Be Taken1998-03-17017 March 1998 PNO-II-98-016:on 980316,licensee Declared Alert Due to Fire in Dumpster Located Outside Fuels Mfg Operations Bldg. Extinguished Fire,Inspected Roof & Posted Hourly Fire Watch. Licensee Will Investigate Root Causes & CAs to Be Taken ML20199B4051998-01-0606 January 1998 Insp Rept 70-1113/97-08 on 971208-12.No Violations Noted. Major Areas Inspected:Licensee Conduct of Plant Operations & Maint PNO-II-97-049, on 970904,stack Sample Above Licensee Action Was Noted.Sample Taken from H Fluoride Bldg Exhaust Stack.Environ Air Samples Collected at Site Boundary & Radioactivity Levels Determined to Be Background1997-09-0505 September 1997 PNO-II-97-049:on 970904,stack Sample Above Licensee Action Was Noted.Sample Taken from H Fluoride Bldg Exhaust Stack.Environ Air Samples Collected at Site Boundary & Radioactivity Levels Determined to Be Background ML20198H4351997-09-0404 September 1997 Partially Withheld Insp Rept 70-1113/97-203 on 970811-15, Per 10CFR2.790 ML20216B1821997-08-29029 August 1997 Insp Rept 70-1113/97-07 on 970714-18.No Violations Noted. Major Areas Inspected:Safety Operations,Radioactive Solid Waste Mgt,Transportation & Emergency Preparedness PNO-II-97-044, on 970808,thirty-seven Salaried Positions Eliminated,Fifteen Positions Resulted from Voluntary Separation & twenty-two Involuntary Eliminations.Areas Affected Were Design,Engineering & Production Scheduling1997-08-14014 August 1997 PNO-II-97-044:on 970808,thirty-seven Salaried Positions Eliminated,Fifteen Positions Resulted from Voluntary Separation & twenty-two Involuntary Eliminations.Areas Affected Were Design,Engineering & Production Scheduling ML20141J7671997-08-11011 August 1997 Insp Rept 70-1113/97-06 on 970623-27.No Violations Noted. Major Areas Inspected:Status of Dry Conversion Facility, Including Completion of Const,Nuclear Criticality Safety, Chemical Safety & Radiation Protection ML20140E6571997-06-0606 June 1997 Insp Rept 70-1113/97-04 on 970326-28,0407-11 & 0429-0509. No Violations Noted.Major Areas Inspected:Status of New Dry Conversion Facility,Including Operations & Completion of Const ML20141K7021997-05-16016 May 1997 Insp Rept 70-1113/97-05 on 970414-18.No Violations Noted. Major Areas Inspected:Rp & FP Programs ML20138J8401997-04-18018 April 1997 Insp Rept 70-1113/97-03 on 970323-27.No Violations Noted. Major Areas Inspected:Environ Protection & Waste Mgt Programs & Status of New Dry Conversion Facility ML20137T5471997-04-0808 April 1997 Insp Rept 70-1113/97-02 on 970303-07 & 17-21.No Violations Noted.Major Areas Inspected:Operations,Training,Construction Completion & Training & Functional Testing of Sys ML20137P8141997-03-0707 March 1997 Insp Rept 70-1113/97-201 on 970303-07.Violation Noted.Rept Details Withheld ML20217D7331997-02-27027 February 1997 Insp Rept 70-1113/97-01 on 970127-31.No Violations Noted. Major Areas Inspected:Plant Operations,Management Organization & Controls,Maintenance/Surveillance,Training & Dcf Project ML20134G9561997-01-28028 January 1997 Notice of Violation from Insp on 961204-08.Violation Noted: on 961130,engineered Control Associated W/Line 3 Calciner Tube Failure Did Not Detect Undesired Situation & Was Not Capable of Performing Criticality Safety Purpose Specified ML20134G9851997-01-28028 January 1997 Special Insp Team Rept 70-1113/96-12 on 961204-08.Violations Noted.Major Areas Inspected:Circumstances Surrounding Tube Failure,Precursors to Event & Response to Event ML20134Q3121996-11-13013 November 1996 Insp Rept 70-1113/96-11 on 961014-18.No Violations Noted. Major Areas Inspected:Plant Operations,Mgt Organization & Control,Maint/Surveillance & Dcf Project ML20134J3971996-11-0606 November 1996 Notice of Violation from Insp on 960930-1003.Violation Noted:Cm&S Analytical Method 1.2.21.10 Was Not Followed in That Data Derived from Urinalysis Tests Performed on 941019 Was Not Recorded ML20134J4071996-11-0606 November 1996 Insp Rept 70-1113/96-10 on 960930-1003.Violations Noted. Major Areas Inspected:Elements of Internal Dose Monitoring & Controls Program Including Activities in Urinalysis Bioassy & Associated Air Sampling Program ML20134C4891996-09-0909 September 1996 Insp Rept 70-1113/96-07 on 960805-09.No Violations Noted. Major Areas Inspected:Review of Listed Physics Program Elements,Independent Radiation Safety Audit,External & Internal Exposure Controls & Organizational Change ML20058P6741993-12-0808 December 1993 Insp Rept 70-1113/93-11 on 931115-19.Non-cited Violations Identified.Major Areas Inspected:Mgt Controls,Organization, Nuclear Criticality Safety,Facility Changes,Maintenance, Operations & NRC Bulletins & Notices ML20058P5011993-12-0303 December 1993 Insp Rept 70-1113/93-10 on 931025-29 & 1101-05.No Violations Noted.Major Areas Inspected:Evaluation of Fuel Processing in Selected Favorable Geometry Operations & Nuclear Criticality Safety Aspects of Modifications Made to Conversion Lines ML20058Q2071993-10-17017 October 1993 Insp Rept 70-1113/93-09 on 930913-17.No Violations Noted. Major Areas Inspected:Licensee Radiation Protection Program Including Program Organization & Staffing,Procedures & Program Changes & Training ML20057E7331993-09-30030 September 1993 Insp Rept 70-1113/93-08 on 930907-10.No Violations or Deviations Noted.Major Areas Inspected:Emergency Preparedness & Which Included Listed Program Elements ML20057C1271993-09-20020 September 1993 Insp Rept 70-1113/93-202 on 930816-20.No Violations Noted. Major Areas Inspected:Mc&A Sys Mgt & Assessment. Proprietary Insp Rept Details Withheld ML20057C2901993-09-15015 September 1993 Insp Rept 70-1113/93-07 on 930830-0903.No Violations or Deviations Noted.Major Areas Inspected:Nuclear Criticality Safety,Operations,Fire Protection,Facility Changes & NRC Bulletins & Notices ML20056E2851993-08-12012 August 1993 Insp Rept 70-1113/93-06 on 930726-30.No Violations Noted. Major Areas Inspected:Mgt Controls,Nuclear Criticality Safety,Maint & Fire Protection ML20056F3711993-08-10010 August 1993 Insp Rept 70-1113/93-05 on 930712-16.No Violations Noted. Major Areas Inspected:Radioactive Effluents,Environ Protection & Transportation of Radioactive Matl ML20128G4351993-02-0202 February 1993 Insp Rept 70-1113/93-01 on 930111-15.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Changes,Facility Operations & follow-up of Previously Identified Items ML20128C0081992-11-23023 November 1992 Insp Rept 70-1113/92-15 on 921013-16.No Violations Noted. Major Areas Inspected:Emergency Facilities,Equipment & Implementing Procedures & Coordination of Emergency Planning W/Offsite Support Agencies ML20128C9151992-11-23023 November 1992 Insp Rept 70-1113/92-17 on 921109-13.No Violations or Deviations Noted.Major Areas Inspected:Mgt Controls,Facility Operations,Facility Changes,Followup on Previously Identified Items & Current Issues PNO-II-91-044, on 910709,licensee Inadvertently Transferred Approx 400 Gallons of Liquid Containing Small Amounts of U from Favorable Geometry Tank (T-417) to Unfavorable Tank (V-103).State of Nc Notified1991-07-10010 July 1991 PNO-II-91-044:on 910709,licensee Inadvertently Transferred Approx 400 Gallons of Liquid Containing Small Amounts of U from Favorable Geometry Tank (T-417) to Unfavorable Tank (V-103).State of Nc Notified PNO-II-91-043, on 910707,NRC Authorized GE Co to Resume Normal Operation of Fluoride & Nitrate Waste Sys,Which Had Been Shut Down Subsequent to 910528 Event at Site1991-07-0808 July 1991 PNO-II-91-043:on 910707,NRC Authorized GE Co to Resume Normal Operation of Fluoride & Nitrate Waste Sys,Which Had Been Shut Down Subsequent to 910528 Event at Site 1999-09-08
[Table view] |
Text
-,
53M4 UNITED STATES q'o NUCLEAR REGULATORY COMMISSION
[ , REGION 18 g j 101 MARIETTA STREET.N.W.
- _;* ATLANTA. GEORGI A 30323 SEP 131985 Report No.: 70-1113/85-15 Licensee: General Electric Company Wilmington, NC 28401 Docket No.: 70-1113 License No.: SNM-1097 Facility Name: General Electric Company Inspection Conducted: p gust p 6 and August 23, 1985 Inspector:
G. L. Troup- '
,M
~/
7f!C[
Date/ Signed Accompanying Personnel: J. N. Grace-(August 14,1985)
K. P. Barr (August 14,1985)
Approved by: "(lk E. J. McA1)ine, Chief,) Material Control and
~
9/Yh$
Date Signed Accountability Section, Nuclear Materials Safety and Safeguards. Branch, Division.of Radiation Safety and Safeguards
SUMMARY
Scope: This routine,. unannounced inspection entailed 33 inspector-hours on site in the areas of management organization and controls, training, nuclear criticality safety, audits, operations, and fuel storage. Additionally, a management meeting was held on August 14, 1985 Results: Of the areas inspected, no violations or deviations were identified.
8509270188 850913 PDR ADOCK 07001113 C PDR 1
J 3
REPORT DETAILS
- 1. Persons Contacted Licensee Employees E. A. Lees, General Manager
- W. W. McMahon,. Manager,. Quality Assurance
- J. E. Bergman, Manager, Manufacturing
- R. A. Petelinkar, Manager, Site Operations and Materials Systems
- B. F. Bentley, Manager, Fuel Chemical Operations
- G. R. Pearson, Manager, Uranium Fuel Fabrication
- C. M. Vaughan, Manager, Regulatory Compliance
- W. C. Peters, Manager, Nuclear Safety Engineering
- R. E._ Lennon, Senior Manager, Manufacturing Training and Program Development
- W. B. Smalley, Manager, Environmental Protection F. C. Eschenlauer, Supervisor, Metallurgical Laboratory J. T. Taylor, Senior Nuclear Safety Engineer G. M. Bowman, Senior Nuclear Safety Engineer S. P. Murray, Senior Nuclear Safety Engineer R. H. (). Folleck, Senior Specialist - License Engineeri~ng G. R. Mallett, Senior Engineer - Measurements and Statistics B. S. Dunn, Specialist - Licensing Support W. B. Haverty, Analyst - Nuclear Material Control R. J. Keenan, Nuclear Safety Engineer
- T. R. Crawford, Environmental Protection Engineer Other licensee employees contacted . included technicians, operators, and office personnel.
- 2. Exit Interview The inspection scope and findings were summarized on August 16, 1985, with those persons-indicated in paragraph I above. The inspector described the areas inspected and discussed in detail the inspection findings listed
~
below. No dissenting comments were received from the licensee. The~
licensee stated that design, process and operational information associated with the Uranium Process Management Project (UPMP) would be considered company proprietary under the terms of 10 CFR 2.790.
- 3. Licensee Action on Previous Enforcement Matters Not inspected.
L i
2
- 4. Management Organization'and Controls'(88005)
- a. Organizational Structures The responsibilities of the licensee's key positions with safety related responsibilities and qualifications of the personnel filling the positions were reviewed in report 70-1113/85-07. 'The inspector discussed the assignments with licensee representatives and determined that there had been no changes or reassignments since the last review.
- b. Safety Review Committee (1) Section 2.3.1 of the license application states ~ that the Safety-Review Committee (SRC) shall be comprised of at least five members appointed by' the Department General Manager, shall meet at least four times a calendar year and shall be responsible for performing certain specified reviews. P/P 40-1, "Wilmington Safety Review Committee" appoints the members- of the position as well. as designates the Chairman and secretary. The procedure was approved by the Department General Manager.
(2) The inspector reviewed the minutes of the meetings- held on June 19, August 28 and December 7,1984, and meetings held on March 28, April 18, April 19 and April 24, 1985. The minutes indicated that a- quorum was present for each meeting, and that >
items requiring action by managers were identified and responsi-bility assigned. The 1985 meetings constituted a review of the status and open work on the UPMP project (See paragraph 9).
No violations or deviations were identified.
- 5. Training / Retraining (88010)
- a. Section 2.6 of the license application requires that nuclear safety training be performed by instructors cert.ified by the manager of the criticality safety and radiation safety functions. This requirement is implemented by P/P 40-17, " Nuclear Safety Training", which requires the documentation of the qualification of instructors and approval by the Manager, Nuclear Safety Engineering. The inspector verified that qualification records .had been prepared and approved for persons currently conducting training.
b .- Section 2.6 of the licensee application ' requires employees will be retrained every two years. - The inspector discussed this requirements with licensee representatives and reviewed computer records used to track the status . of retraining, and identify individuals requiring retraining. During tours of the process ' areas, discussions with ir.dividuals indicated that they had received nuclear safety training within the past year and that they were aware.of the requirements for periodic retraining.
3
- 6. Nuclear Criticality Safety (88015)
- a. Facility Modification and Changes The inspector reviewed four facilities change requests . and the 1
associated ' nuclear safety analyses. The inspector verified that the analyses were conducted using approved evaluation methods and that the analyses were verified by an inde' pendent-reviewer. The inspector also verified that preoperational audits had ~ been conducted prior to the issuance of the final approval by Nuclear Safety Engineering,:and that a Nuclear Safety Release / Requirement (NSR/R) had been approved by the Area Manager and Nuclear Safety Engineering prior to f ssuance. The inspector also reviewed six change requests which were '
ev'aluated as not
-requiring a nuclear. safety analysis. \'
No violations or deviations were identified.,. ,
- b. Nuclear Safety Analysis Methods The inspector discussed the methods used to perform nuclear safety calculations with the cegnizant individuals and verified that the methods used were in= accordance with the licensee requirements.
Calculational methods which may be used and individuals designated as qualified to perform analyses and/or to perform the independent verification are specified in NSI E-4.0, " Criticality Safety Analysis Methods and Verification". A licensee representative informed the inspector that three approved codes are presently used.
No violations or deviations were identified.
- c. SNM Containers Table 13.7 of the license application lists the shipping containers authorized for use by the licensee. A licensee representative informed the inspector that no other containers were in use. During tours of-the facility the inspector did not observe any shipping containers which were not listed in Table 13.7.
- d. Proceduces _
The inspector reviewed five procedures for performing nuclear safety
' analyses. No changes or revisions to these procedures had been made
.since the last review.
", , 7. Audits (88005,88015)
- a. Sections 2.8.1 and 2.8.3 of the license appl'fcation specify require-ments for internal quarterly audits and. biennial external audits. The inspector reviewed the written report for'the second quarter internal audit conducted in June 1985 and an external' audit conducted by the Quality Assurance and Reliability Operation (QAR0) in May 1985. The y -j
4 inspector verified that the audit findings were documented and submitted to management, that corrective actions were documented, and each item closed after the adequacy was determined.
- b. The inspector reviewed .the_ audit reports and determined that auditors were rotated during the quarterly audits. A memorandum from the Manager, Nuclear Safety Engineering Edated September- 17, 1984, designated the senior members of the criticality safety and radiation safety functions for auditor qualification. Individuals to perform audits are designated in writing prior to the audit.
- c. Nuclear Safety Instruction NSI 2.0, " Internal Nuclear Safety Audits",
requires that quarterly audits be conducted at the Greenville, SC warehouse. An audit form has been p epared for these audits. The inspector reviewed fthe audit reports for the audits _ conducted on February 21, 1985 a6d - May 23, 1985. Additionally, the inspector
~
observed.the audit conducted on August 23, 1985 (see paragraph 11).
No violations or deviations'were identified.
- 8. Operations Review (88020, 88025)
- a. Tours During the inspection, tours were made of various work areas to observe operations. Items. reviewed or verified included:
-(1) Special nuclear material was stored in arrays on carts, conveyors, and process areas, and in designated storage locations in accordance with license requirements.
(2) Housekeeping and industrial safety provisions :in all areas were acceptable.
(3) Operating ~ procedures (PRODS) were available in the various areas.
Nuclear Safety Release / Requirements and Radiological Safety Instructions were also available.
(4) Compressed gas cylinders were constrained by a rope or chain in accordance with good industrial safety' practices.
(5) Containers of SNM were marked to identify the enrichment of the material. Observed enrichments were within posted limits.
(6) Quantities ofc SNM in waste boxes were checked for conformance of labeled quantities'in each box and the total in the array with the posted limits for the area. ,
5
- b. Hydrofluoric Acid Shipments
! Section 1.8.3.1 of the License Application (a condition of the license) authorizes the sale of hydrofluoric acid to a non-licensed company provided that the uranium concentration is less than 3 ppm. The inspector reviewed the records for the shipments of acid made in 1985 and determined that the material was less than the uranium concentra-tion limit and was shipped to the designated receiver.
No violations or deviations were identified.
- 9. Uranium Process, Management Project (UPMP) (88015, 88020)
I
- a. Amendment 3 to' license SNM-1097, dated Febraury 26, 1985, authorized :
i the use of UPMP to process licensed materials. The licensee has started using several subsystems of UPMP to process uranium bearing process streams.
- b. The inspector reviewed the following documents related,to the startup of the UPMP subsystems:
(1) Memoranda dated May 9,1985, May 16,1985, and June 3, 1985, from the Manager, Nuclear Safety Engineering to the Manager, Fuel Chemical Operations which approved the operation of the systems with uranium and constituted the official nuclear safety releases.
(2) Safety Review Committee minutes for meetings 3.on March 28, April 18, April 19, and April 24, 1985, which pertained Eto t.he status, training, and preoperational testing for. UPMP. .
(3) Approximately 25 Nuclear Safety Release /Requireme'nts (NSR/Rs) for proper review and approval and verification thdt nuclear safety "
requirements were consistent with the license ' application and nuclear safety analyses. A total of 63 NSR/Rs have been prepared and approved.
No violations or deviations were identified.
- 10. Management Meeting 3
- a. On Augu'st 14, 1985, a management meeting was held at the Nuclear Fuel Manufacturing Department.
NRC Attendees ,
J. Nelson Grace, Regional Administrator, Region II i;
K. P. Barr, Chief, Nuclear Materials Safety and Safeguards Branch G. L. Troup, Fuel, Facilities Inspector a
.f
?
~- -.
-._g,,. ,7,. gv ,_ ~ . . - _ . _ . . - ,, - - . _.. . -
6 GE - NFMD attendees E. A. Lees, General Manager J. E. Bergman, Manager, Manufacturing R. A. Petelinkar, Manager, Site Operations and Materials Systems
, W. W. McMahon, Manager, Quality Assurance J. L. Harmon, Manager, Manufacturing Technology and Engineering Operations B. F. Bentley, Manager, Fuel Chemical Operations C. M. Vaughan, Manager, Regulatory Compliance W. C. Peters, Manager, Nuclear Safety Engineering S. P. Murray, Senior Nuclear Safety Engineer
- b. The purpose of the meeting was to familiarize the Regional Adminis'-
trator with the facilities and operations of the NFMD. Topics discussed included the organization, qualifications of key managers, site facilities, and fuel manufacturing operations. The meeting
. included a tour of the fuel manufacturing areas and associated support facilities.
- 11. Greenville Fuel Storage Facility
- a. Sections 1.8.4.2 and 1.8.4.3 of the license application authorize the licensee to store uranium and completed fuel assemblies at the storage-warehouse in Greenville, SC. Fuel assemblies may be stored either in packages as for transport in a Fissile Class I package or in the metal inner containers of the RA-series shipping package under certificate of compliance USA /986/AF.
b.- On August 23, 1985, the inspector toured the . warehouse to observe operations. Items reviewed or verified included:
(1) Nuclear Safety requirements (NSR/Rs) were current, and were posted in each section of the warehouse.
(2) Materials were contained in approved shipping containers,-and were-stored iri approved arrays.
(3) All licensed material was stored inside of the ware. house.
(4) Flammable and combustible materials were stored in a designated steel storage cabinet.
(5) Warehouse doors were posted with ' appropriate radiation warning I signs.
'(6) Security and fire alarms were installed and functional. l No violations or deviations were identified.
l l
l
_