4 MAR 161990 MEMORANDUM FOR: Wii. tam F. Kane, Director Division of Reactor Projects THRU:

James C. Linville, Chief Reactor Projects Branch No. 1 FROM:

Curtis J. Cowgill, Chief Reactor Projects Section No. 1A

SUBJECT:

CALVERT CLIFFS AUGMENTED STARTUP INSPECTION PLAN Calvert Cliffs has been shut down under Confirmatory Action Letter (CAL) since May 1989.

Significant problems and issues were identified in various inspec-tions which required closure prior to. restart of either unit.

Most of these items have been resolved as documented in the last several resident reports.

The remaining issues are currently under review for closure.

The licensee's current schedule shows a readiness to begin mode change activ-ities late March or early April with reactor startup about 12 days later.

Augmented inspection coverage has been scheduled to monitor the facility's startup and return to power. outlines this augmented coverage.

This inspection is intended to verify startup preparations have been properly completed, operators have been trained on modifications made, surveillances have been completed, maintenance is controlled and that management and opera-tors conduct a controlled, safe and orderly startup. identifies the weekly activities required during the preparation for heatup and subsequent startup and power operation. Periods of round-the-clock coverage will be included during critical and power operations.

Exten-sive backshift inspection will be performed during mode change activities. The Team will include members of the division of Reactor Safety and the NRR Licen-sing Project Manager.

Larry Nicholson will be Team Leader.

C"GP'/J. S!GNED BY.

CLRT!D J. C ;qu Curtis J. Cowgill, Chief Reactor Pro'jects Section No. IA

Enclosures:

l As stated 1

eld %

xh A

0FFICIAL RECORD COPY COWGILL 626 3/14/90 - 0001.0.0 p 3v 1

g J/3 O//L g

03/15/90

~ iig 8

a

Memoran'dum for William F. Kane -

2 MAR 161990 cc w/encis:

W. Russell, RA T. Martin, DRA W. Hodges, DRS M. Knapp, DRSS J. Wiggins, DRP 1

R. Gallo, DRS i

J. Durr, DRS J. Linville, DRP N. Blumberg, DRS P. Eselgroth, DRS D.:Limroth, DRP K. Lathrop, DRP D. Vito, DRP L. Nicholson, SRI - Calvert Cliffs T. Kim, RI - Calvert Cliffs A. Howe, RI - Calvert Cliffs j

B. Boger, NRR R. Capra, NRR D. Mcdonald, NRR j

i RI:DRP k RI:DRP R

[

CCowgill/mjd JLinville W

e 3/f/90 3/f(/90 3/I/90 0FFICIAL RECORD COPY COWGILL 626 3/I4/90 - 0002.0.0 03/15/90

a ENCLOSURE 1 Calvert Cliffs Startup Inspection Plan A.

Pre-Startup and Startup Preparations 1.

Independently review selected system lineups (IMC 71710):

Auxiliary Feedwater Containment Spray Service Water RCS Electrical (Partial)

Perform after the licensee has completed their lineups.

2.

Review the estimated critical position calculations (61707).

3.

RCS (71707).

4.

Observe selected startup checklist activities (0P-6).

5.

Verify operable status of emergency response facilities.

6.

Review licensee operator training for outage modifications (71707).

7.

Resolution of operational items associated with previous inspections.

8.

Observe and review surveillance tests during mode ascension with special emphasis on the following areas:

ECCS Pump Operability Tests Reactor Protection System (Including Nuclear Instrumentation)

EDG and Associated Emergency Power Supply Tests B.

Extended Shift Coverage (Power Ascension Schedule) (71707 and 71715)

Verify:

Operators are attentive and re ponsive to plant parameters and conditions.

Procedures are used and followed as required by plant policy.

0FFICIAL RECORD COPY COWGILL 626 3/14/90 - 0003.0.0 03/15/90

l

- - Calvert Cliffs Startup 2

Inspection Plan Logkeeping is timely, accurate, and adequately reflects plant activ-ities and status.

Shift turnovers are conducted in an effective manner.

)

Control room atmosphere is quiet and access is appropriately controlled.

t Shift manning is as per plant Technical Specifications and 10 CFR 50.54(m) (82205).

Observe:

1 Surveillance performance as opportunities present themselves (61726) and as directed by number 8.

Equipment operator rounds and evolutions.

Operator training evolutions.

Selected maintenance activities outside the control room (62703).

Perform primary system leak rate evaluation (71628).

Observe startup testing activities (72700).

Operations interface with other disciplines (i.e., engineering).

Tagouts are properly reviewed and authorized.

C.

Observe and assess BG&E's management involvement with restart and power ascension program including implementation of the licensee's self-assess-ment of their activities.

D.

Followup on observed anomalies during startup as they occur and assess

{

management emphasis on quality and safety over power production.

E.

Attend Plant Safety Committee meetings.

F.

Perform around-the-clock control room surveillance of selected critical-ity, and power ascension milestones and activities.

G.

During surveillance activity observations, confirm the following:

Confirm training of technicians.

Observe for procedure adherence.

OFFICIAL RECORD COPY COWGILL 626 3/14/90 - 0004.0.0 03/15/90

e., - Calvert Cliffs Startup 3

Inspection Plan Observe that test equipment is properly installed and calibrated.

Confirm that licensee is properly. implementing latest revision of CCI-120.

That' completed STs get prompt review by licensee management chain including Shift Supervisor review.

1 i

i l

l 0FFICIAL RECORD COPY C0WGILL 626 3/14/90 - 0005.0.0 03/15/90

I ENCLOSURE 2 Activities i

Week 1:

i Plant Status:

Final Preparations for Startup i

)

Staffing:

Residents and 2 from Region (DRS)

Goals:

Valve Lineup (71710)

ESF System Walkdown (71710)'

Evaluate Plant Material Condition Evaluate Adequacy of System Engineer Walkdowns Assess Identification / Resolution of Discrepancies Surveillance (61726)

Review Plant-Logs Review Startup Checklist Assess Management Involvement Evaluate Licensee Self-Assessment Capability Week 2:

Plant Status: Hot Sh'utdown Work / Enter Mode 3 Staffing:

Residents and 2 from Region (ORS and Section Reactor or Project Engineer)

Goals:

Maintenance Review (Review Ongoing and Outstanding)

Assess Adequacy Compliance with Procedures Assess Identification / Resolution of Discrepancies Review Startup Checklist Review Plant Logs Evaluate Operations Training on Outage Modifications Follow Auxiliary Building Operator on Rounds Evaluate Plant Material Condition Verify Status of Emergency Response Facility Evaluate Licensee Self-Assessment Capability Assess Management Involvement i

0FFICIAL RECORD COPY COWGILL 626 3/14/90 - 0006.0.0 03/15/90

4.

l 2

i 1

Week 3:

Plant Status: Final Preparations and Criticality Staffino:

Residents and 3 from Region (DRS and Section Reactor or Project Engineer)

Goals:

Surveillance Maintenance Evaluate Licensee Self-Assessment Assess Adequacy and Compliance with Procedures Assess Identification / Resolution of Discrepancies Attend POSRC Meetings Review Startup Checklist Review Outstanding Jumpers / Temperature Modifications Review Plant Logs (Including Plant Status Logs)

Evaluate Plant Material Condition Evaluate Operations Interface with Other Departments Limited Sustained Control Room Observation Week 4:

Plant Status: Power Operation and Shutdown Staffing:

Residents and 3 (DRS, LPM, Section Reactor or Project Engineer) 1 Goals:

Sustained Control Room Observation Surveillance Assess Adequacy and Compliance with Procedures Review Plant Logs Evaluate Plant Material Condition Review Estimated Critical Position Calculations Primary System Leak Rate Evaluation Observe Startup Testing Assess Management Involvement Evaluate Licensee Self-Assessment Capability Attend POSRC Meetings Evaluate Operations Interface with Other Departments

. ~.,

OFFICIAL RECORD COPY COWGILL 626 3/14/90 - 0007.0.0 03/15/90