l SEP 2 51987 MEMORANDUM FORc Robert A. Capra, Project Director Project Directorate I-l Division of Reactor Projects I/II FROM:

M. W. Hodges, Chief Reactor Systems Branch Division of Engineering & Systems Technology

SUBJECT:

SAFETY EVALUATION OF CEN-348(B)-P, " EXTENDED STATISTICAL i

COMBINATION OF UNCERTAINTIES" Plant Name:

Calvert Cliffs Units 1 and 2 Docket Nos.:

50-317 and 50-318 TAC Nos.:

64985 and 64986 Project Directorate:

Project Directorate I-1 Project Manager:

S. McNeil Review Branch:

SRXB Review Status:

Complete The Reactor Systems Branch has reviewed the Extended Statistical Combination of Uncertainties (ESCU) methodology presented in topical report CEN_348(BI-P.

This report describes a modified methodology of the existing Statistical j

Combination of Uncertainties (SCU) for statistically combining the uncertainties involved in the departure from nucleate boiling and its associated analog system setpoints which had previously been approved by the staff. The staff finds the ESCU methodology acceptable for Calvert Cliffs Units 1 and 2 utilizing CE 14x14 fuel assemblies.

This completes the staff's effort on TACs 64985 and 64986. A SALP imput is i

also enclosed.

W W m p ed by Mmte lhdges M. W. Hodges, Chief Reactor 3ystems Branch Division of Engineering & Systems Technology

Enclosures:

DISTRIBUTION As stated Docket File SRXB R/F cc:

S. Varga MWHodges B. Boger TCollins A. Thadani AThadani S. McNeil LKopp LKopp R/F

Contact:

L. Kopp, SRXB Calvert Cliffs P/F x24204

\\

i FC :5RXB: DEST X

T

5RXB: DES g :5 : DEST AME :LK0PP:j S
MWH0DGES
ACTh ani ATE S/M /87 9 7 '87 9/t/87 9

/87 OFFICIAL RELORD COPY

/