l SAFETY EVALUATION REGARDING THE-PROCEDURES GENERATION PACKAGE FOR CALVERT CLIFFS NUCLEAR PLANT UNITS 1 AND 2

~

1.

INTRODUCTION The"TMIActionPlan"(NUREG-0660andNUREG-0737)requiredlicenseesof operating reactors to reanalyze transients and accidents and to upgrade energency operating procedures (EOPs) (Item I.C.1).

The plan also required the NRC staff to develop.a long-term plan that integrated and expanded efforts in the writing, reviewing, and monitoring of plant procedures (ItemI.C.9). NUREG-0899, " Guidelines for the Preparation of i

Emergency Operating Procedures," describes the use of a " Procedures l

Generation Package" (PGP) to prepare E0Ps. A PGP is required by Generic l

Letter 82-33, Supplement I to NUREG-0737, " Requirements for Emergency Response Capability." The generic letter requires each licensee to submit a PGP, which includes:

l (1)

Plant-specific technical guidelines (ii)

A writer's guide I

i (iff)

A description of the program to be used for the validation of E0Ps

-l l

(iv)

A description of the training program for the upgraded i

E0Ps.

This re

-(BG&E) port is the review of the Baltisere Gas and Electric Company submittal describing the development and implementation of E0Ps for Calvert Cliffs Nuclear Power Plant, Units 1 and 2. (CCNP).

The review was conducted to determine the adequacy of the BG&E program for preparing, implementing, and maintaining upgraded E0Ps for CCNP. This review was based on NUREG-0800, Subsection 13.5.2, " Standard Review Plan for tise Review of Safety Analysis Reports for Nuclear Power Plants."

Section 2 of this report briefly discusses the BG&E submittal, the NRC staff review, and the acceptability of the submittal. Section 3 contains the staff's conclusions.

The staff determined that the procedures generation program for CCNP has several items that must be satisfactorily addressed before the PGP is acceptable. BG&E should address these items in a revision to the PGP or document justification for why such revisions are not necessary. This revision and/or justification need not be submitted, but should be retained for subsequent review by the NRC staff. The revision of the PGP, and subsequently of the E0Ps, should not impact the schedule for the use of the E0Ps. The revision should be made in accordance with the CCNP administrative procedures and 10 CFR 50.59.

9608060007 960731 IC 6-237 PDR

i*

2.

EVALUATION AND FINDINGS 1

i i

In a letter dated March 14, 1984, from A. E. Lundvall (BG&E) to the Director of Nuclear Reactor Regulation, BGAE submitted its PGP of CCNP.

The staff conducted a review of the CCNP PGP, and identified its findings i

in a Request for Additional Information (RAI) which was forwarded to BG&E l

in.a letter dated August 7,1985. BGAE provided responses to the RAI items in a letter dated October 23, 1985 from A. E. Lundvall to A. C.

Thadant(NRC).

In a letter dated July 25, 1988,'from J. A. Tiernan (BG8E) l l

to the U.S. Nuclear Regulatory Commission, BG8E submitted a revised 1

Procedures Writer's Guide. The July 25, 1988 letter also contained the j

procedure verification / validation plan and the E0P training program. The PGP contained the following sections:

Plant-Specific Technical Guidelines Emergency Operating Procedure Writer's Guide l

Description of Verification / Validation Program t

E0P Training Program Description i

i-Sample E0P The staff review of the CCNP PGP is documented in the following j

subsections:

i j

A.

Plant-SpecificTechnicalGuidelines(P-STG) i The P-STG program description was reviewed to determine if it described acceptable methods for accomplishing the objectives stated j

in NUREG-0899. The P-STG includes a discussion of the process of j

how the licensee plans to develop the E0Ps from the generic j

technicalguidelines(CEN-153). The licensee described a process j

where the source material listed in the writer's guide will be used i

to establish plant-specific entry conditions, precautions, immediate l

actions, recovery actions, and exit conditions (where appropriate) for each procedure. This plant-specific information is to be compared with the generic guidelines and any deviations are to be formally documented. Engineering analysis will be done as l

required. When a deviation is substantiated, it will be incorporated into the plant-specific procedure. BG8E identified the following j

source documents for use in generating E0Ps for CCNP:

i i

Final Safety Analysis Report

}

Technical Specifications Architect / Engineer Technical Documentation Human Factors considerations J

Operating experience 1

Technical manual i

POEAC reconnendations j

POSRC recommendations

[

2 l

5, t

j' Procedural Development request forms CCOM Change Reports Current and past revisions of OIs, ops, A0Ps and E0Ps i

Combustion Engineering generic emergency proc,edure guidelines (CEN-152)

The staff review of the CCNP P-STG identified no concerns.

l The CCNP plant-s acific technical guidelines program should accomplish the oajectives stated in NUREG-0899 and should provide.

l adequate guidance for translating the Combustion Engineering Generic Emergency Procedure Guidolines into the CCNP E0Ps.

l t

As a result of our review of the revised PGP, the staff has the i

i following additional comment. This comment is provided with the recommendation that BG&E consider incorporating the resolution to i

4 y

this comment in the next revision of the CCNP PGP.

1 In the October 23, 1985 letter item A.3 states that 86&E will i

translate generic information and control characteristic document i

into a plant-specific document as a part of the control room design i

review project.

In order to make tie PGP complete, this control

}

characteristic document should be referenced in the PGP.

B.

Writer's Guide I

4 Tb a iter's guide was reviewed to determine if it described I

t acceptable methods for accomplishing the objectives stated in NUREG-0899. The CCNP writer's guide provides guidelines to be employed in the preparation of E0Ps. These guidelines have been established to insure consistancy in the organization, format, style, and content of CCNP E0Ps. The staff identified the following concerns:

1.

Information should be presented ti, procedures so that interrup-tions in the procedure's flow are minimal. To achieve this, each procedure should be written so that an action step is completed on the page where it began. The only valid reason for breaking an action step is when the step is too long to fit entirely on one page.

In that event, the action step should probably be re-written, if possible, in order to shorten it.

The limitations of wordprocessing tools are Swfficient justification for breaking action steps between pages.

2.

Major functions the operator must accomplish during an event are placed in boxes. The writer's guide shows examples of major functions bordered by horizontal lines but not boxes. This inconsistency should be corrected.

3

~

r With adequate resolution of the abo' e items, the CCNP writer's guide v

7 should accomplish the objectives stated in NUREG-0899 and should i

provide adequate guidance for translating the technical guidelines into E0Ps that will be usele, accurate, complete, readable, convenient to use and acceptable to control room operators.

4 As a result of our review of the revised writer's guide, the staff has the following additional comments. These comments are provided 4

with the recommendation that BG&E consider incorporating resolutions to 'hese comments in the next revision of the CCNP writer's guide, i

3.

The discussion in the writer's guide of cautions and notes should be revised with regard to the following:

i a.

The section in the writer's guide on cautions and notes l

should be expanded to describe a method of formatting l

notes. So that notes are not confused with cautions, this format should be clearly different than the format used for cautions.'

j b.

The writer's guide should state that notes will be complete on one page, i.e., a note will not be broken between pages. An example of a properly formatted note should be included.

The writer's guide should contain an example of a properly c.

formatted caution.

d.

The writer's guide should further state that enly one topic will be included in a caution or note. When a caution or note contains more than one topic, the j

importance of any one topic is obscured.

i 4.

The discussion in the writer's guide of logic terms should be i

revised with regard to the following i

a.

The writer's guide implies that OR may be used in both the i

inclusive and the exclusive sense.' The exclusive OR should be presented in a different manner than the-1 inclusive OR. The writer's guide should provide instructioiis for formatting logic statements that use OR used in either sense.

b.

The writer's guide should discuss the logic term IF NOT.

c.

Using the logic term THEN at the end of an action to intt uct the operator to perform another action within the same step runs actions together. Actions that are embedded in this way create several problems: embedded actions may be overlooked and not performed, or they may be confused with logic statements. The writer's guide should state that THEN will not be used to run action steps together.

4

i d.

The writer's guide should discuss the use of AND and OR within the same step. An example should be provided.~

l S.

The writer's guide should ;e expanded to include examples of referencing and branching formats that are consistent with the text.

6.

Section VII.C.2.b, page 17, states, " Brackets will normally not be used." There is neither a statement as to when brackets are permissable nor an example of the proper use of brackets. The writer's guide should be amended to specify when brackets may be used.

7.

Section VII.C.3.b, page 18, instructs procedure writers to use words that are concrete rather than vague, specific rather than general, familiar rather than formal, precise rather than blanket. -It should also state that key words with more than one meaning will be avoided in E0Ps. Such terms should be included in a list of words to avoid.

If ambiguous key words must be used in E0Ps, they should be defined every time they are used.

8.

The writer's guide should include instructions for writing the I

various types of action steps that an operator may take to cope with different plant situations.

a.

The writer's guide should address the definition and format of the following types of action steps and should provide examples: nonsequential steps, equally acceptable steps, concurrent steps, and diagnostic steps. See NUREG-0899, Section 5.7, for further information.

b.

The writer's guide should include a means by which operators will be reminded to perform recurrent steps, as well as a means of letting operators know when it is no longer necessary to perform a recurrent step.

c.

The writer's guide should discuss the location of E0Ps in the control room and the techniques that will be used to differentiate E0Ps from other plant procedures.

C.

Verification and Validation Program l

The description of the verification and validation program was reviewed to determine if it described acceptable methods for accomplishing the objectives stated in NUREG-0899. The verification program plan-describes methods for confirming the technical accuracy and written correctness of the procedures. The validation program plan describes methods for confirming the usability and operational correctness of the procedures. The staff identified the following concerns:

L 5

1.

The verification and validation programs describe the verification and validation that was performed on existing E0Ps but do not specify that the programs will be followed in the future. The validation and verification programs should describe BG8E's plan for verifying and validating current E0Ps as well as E0Ps'that receive major revisions.

2.

The verification and validation program should specify the criteria for selection'of team members, and the role and re-sponsibilities of each individual involved in all phases of verification and validation program.

With adequate resolution of the above items, the CCNP verification and validation program should accomplish the objectives stated-in NUREG-0899 and should provide assurance that the E0Ps adequately incorporate the guidance of the writer's guide and the technical guidelines and will guide the operator in mitigating emergency conditions.

D.

Training Program The description of the operator training program on the CCNP upgraded E0Ps was reviewed to determine if it described acceptable methods for accomplishing the objectives stated in NUREG-0899. The training program will be established to support implementation of the E0Ps.

The staff identified the following concern:

The training program and CCNP training policy guidelines should state that all operators will be trained in the latest revisions of all E0Ps before assuming responsibility for their assigned duty station.

With adequate resolution of the above item, the CCNP training program should accomplish the objectives stated in NUREG-C099 and should result in appropriate training for the CCNP operators on the upgraded E0Ps.

3.

CONCLUSIONS' i

The staff concludes that, the PGP submitted by Baltisere Gas and Electric

)

Company for Calvert Cliffs Nuclear Plant Units 1 and 2 in letters to the

{

NRC, dated March 14, 1984, October 23, 1985, and July 25, 1988 should be reviewed to address the programmatic improvements outlined in Section 2 of this report. A PGP revision should not be submitted to the NRC. For items the licensee deems inappropriate or no longer appitcable for inclu-sion in its PGP, it should develop and maintain documented justification in an auditable form. All revisions to the PGP should be reficcted in plant E0Ps within a reasonable period of time, e.g., the next planned revision of the E0Ps.

6

.-