05000416/LER-1982-138, Interim LER 82-138/99X-0:on 821112,during Shutdown,Several Duct Covers Could Not Be Installed Due to Cables Extending Through Ducts.Caused by Faulty Design Document.Engineering Evaluation Underway

From kanterella
(Redirected from ML20079J271)
Jump to navigation Jump to search
Interim LER 82-138/99X-0:on 821112,during Shutdown,Several Duct Covers Could Not Be Installed Due to Cables Extending Through Ducts.Caused by Faulty Design Document.Engineering Evaluation Underway
ML20079J271
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 12/16/1982
From: Ambrosino R
MISSISSIPPI POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20079J253 List:
References
LER-82-138-99X, NUDOCS 8212280154
Download: ML20079J271 (1)


LER-2082-138, Interim LER 82-138/99X-0:on 821112,during Shutdown,Several Duct Covers Could Not Be Installed Due to Cables Extending Through Ducts.Caused by Faulty Design Document.Engineering Evaluation Underway
Event date:
Report date:
4162082138R00 - NRC Website

text

_ _ _ _ _ _ _ _ --_

NRC FC RM 366 > U. S. NUCLE AR REGULATtRY COMMISSION

'. . LICENSEE EVENT REPORT Attachm:nt to AECM-82/611

- Page 1 of 1 CONTROL BLOCK: l 1

l l l l l lh 6

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) l0 l1l 7 8 9 lM l LICENSEE S lG CODE lG lS l1 l@l0 l0 l- l0uCENSE 14 15 l0 l0 NUMBER l0 l0 l- l0 l0 l@l4 25 26 l1LICENSE l1 l1TYPE l1JOl@l$ 7 CAl T 68l@

CON'T lOltl 7 8 3o[n$lLl@l0l 60 61 5l DOCKET Ol Ol NUMBER 0l 4l ll 6 h l 11EVENT 68 69 l1 DATEl2 l8 l2 hl1 12REPORT 74 75 l1 l6 lR I?80 Ih DATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h 10121 lDuring shutdown, while performing approved maintenance work on the control room floor l l c l a l l grid seals and duct covers, it was not possible to install several duct covers because l

!O l4 l lof cables extending through the ducts. Duct covers involved are identified in l l O 151 l Material Nonconformance Report (MNCR)-00648-82. An LCO was entered in accordance withl 10 is l lT.S.3.7.7. This had no effect on the health and safety of the public and did not l l 0 l 7 l l Constitute a threat to plant safety. This is submitted as an interim Special Report l I O la l l pursuant to T.S.6.9.2. A final report will be submitted by February 14, 1982. l 7 8 9 80 C DE CODE SUSC E COMPONENT CODE SU Code SU E 10191 7 8 lZ lZ lh dh lC l@ l Xl Xl Xl Xl Xl Xl@ y@ W @

9 10 11 12 13 18 19 20

_ SEQUENTIAL OCCURRENCE REPORT REVISION LER/RO EVENT YE AR REPORT NO. CODE TYPE NO.

b REPjE gU RT

_ 21 l8l2l 22 l-l 23 l 1l 3l 8l 24 26 l/l 27 l9l9l 28 23 y

30 l-l 31 W32 KN AC ON ON PL NT E HOURS SB IT FoR B. SUPPLI R MANUFACTURER lZ l@[E_j@ l35Z l@ lZ l@ l O l 0 l O l0 l l_Nj @ W@ [A_j@ l44X l 9 l 9 l 947 l@

33 34  % 31 40 41 42 43 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h IilOllAn hourly firewatch was established in accordance with T.S.3.7.7. Cables were l ITTT1 linstalled during construction phase when all covers were removed. Consideration of I lil7l l duct covers was not given by the applicable design document which installed the l lil3l l cables. An engineering evaluation is underway to determine if fire barriers shOuld l li l4 l lbe installed or dust covers modified. This is an interim report. l 7 8 9 80 ST S  % POWER OTHER STATUS DIS O RY Di'CoVERY DESCRIPTION I1 15l $ h l0l0l0l@l NA l lC l@l Special Inspection l A TIVITY CO TENT RELEASED OF RELEASE AVOUNT OF ACTIVITY LOCATION OF RELEASE Q W @ [Zj@l 7 8 9 10 11 NA 44 l l 45 NA l 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION l1 l 7 l l 0 l 0 l 0 l@l Z l@l NA l PERSONNEL INJUF tES NUVBER DESCRIPTION 7

i a 8 9 l0l0l0l@l 11 12 NA 80 l

LOSS TYPE OF DESCRIPTION OR DAMAGE To FACILITY v Q

i 9 lZl@l NA PREPARER: J. M. Floyd l Pueu$TY I 8212280154 821216 l NRC USE ONLY DESCRIPTION hl PDR ADOCK 05000416 i ,

S 2 o ISSUEl81 La ,P,DR l llllllllll lllj 7 8 9 10 68 69 80 %

NAME OF PREPARER Original siened by R.A . Ambrosino PHONE: