g4 UNITED STATES
[
NUCLEAR REGULATORY COMMISSION 2, !
e-L(*'
E REGION IV l
8 611 RYAN PLAZA DRIVE, SUITE 1000 8
0,,
ARLINGTON, TEXAS 76011 January 21, 1982 MEMORAN' UM FOR:
Ed Jordan, Director, Division of Engineering and J
Quality Assurance, IE FROM:
John T. Collins, Regional Administrator, Region IV
SUBJECT:
HAYWARD TYLER PUMP COMPANY As a follow up to our phone conversation on Wednesday, January 20, 1982, I have enclosed a listing of pumps manufactured by Hayward Tyler Pump Company for the period 1977-1981.
Note that two operating facilities, Salem 1 & 2 and Oconee, have received pumps from this company during this period and that the pumps were for non-safety systems.
From our conversation, it is my understanding that you will discuss with Bob Bernero some type of risk analysis, particularly for those pumps installed in operating facilities.
Please keep mc advised as to your progress in this regard.
Q)b.w'/ bF6bsU' 400hn T. Collins Regional Administrator Enclos ure:
As stated cc: w/o en cl.
R. DeYoung, IE V. Stello, DEDROGR K. Seyfrit, RIV J. Potapovs, RIV 8205100156 820412 PDR FUIA LIEBOLD82-117 PDR Sb