ML20040G714

From kanterella
Jump to navigation Jump to search
LER 82-001/01T-0:on 820117,reactor Bldg Equipment Hatch Found Leaking Air Through Gap in Seal.Caused by Personnel Not Verifying Good metal-to-gasket Seal Had Been Made. Procedures Revised to Require Verification of Proper Seal
ML20040G714
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 01/29/1982
From: Kutzer J
DUKE POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20040G708 List:
References
LER-82-001-01T, LER-82-1-1T, NUDOCS 8202160395
Download: ML20040G714 (1)


Text

o o w M AC PC A Ae '84 U.s.NUCLsAA AsCULATORY cOmanetsgacas a.ns f.!CENSEE EVENT REPCRT EXHIBIT A cenTmet aLocc l l 1  !

I I l@ teLzAss raixT cm Tves ALL macuineo i*sCAMATtCN3 la I il4 9l S !C l N! El E l 2 gf 010 l -l 0 [0 l 0 ; 010l -l 01 8Olgj 4 l 1l 1; 1l1 lg l lg 3 wcGeste c:04 le 'S bc1MS4 w ueEA 3 webs 4 rvet A 67 :.4 7 .4 ccm-124i6 O lL .e@l 015 l0101012l710 Cla 01111171812 @l 01112191812  !@

i e ei occmav % .a se aviar sara  :. s asecar :4rs so svsNT:sscairnca Amo anceasta cousscussess @

1 o ,21 10n January 17, 1982, during defueling operations, the Reactor Building equip- t

,,,,,  ; ment hatch was found to be leaking air through a gap in the seal at the bottom, of the hatch. This condition existed for fourteen hours of defueling opera-

,,o.I  ;

i,,,,i tions. If a fuel assembly had been dropped, the fuel would have remained t o . , i covered by the borated water in the refueling canal. Due to the small size of,

,3,,, gthe gap and the short duration of the incident, it is felt that the health and

,,, , safety of the public were not affected.

mrw uuss aw. :_ . ..u ,

c=ce cece n..c c. ..w :: n 3. ,s.c::,

li'$a ISIAlg g g lClg

. . i, is I P t l N;E g ; R g ..c; g g ;3-i .. ,,

7; g

$aI"2

=e **~de*I'** 0*."'

' '5**

  • b 'uar.oS Ig= L,

{rv*ar'taa I--! I,.O I 0l 1 I l/t  ! O I 1I lT l ly 2, s 2, a a a O EN J.5r *:,4 20" u..

10 !0 ! 0gl 'E.'1"#G'

,J*t'.. "J"A:*,7 El?;!;4, I

@ @ Zfg l

@ l g lN l@ lL j@ lB l11310 causs cascairvien Ano ccansc nvs Ac- ess i,,ai{The apparent cause of this inc ent was that the personnel who reinstalled the,

,,,,,, hatch did not verify a good metal-to-gasket seal had been made. Fuel handling

,,,,,,was stopped and the equipment hatch properly scaled. The procedure has been ,

revised to require verification of a proper seal and appropriate personnel will, 6 i . :1 I

,,, ,, review this incident. ,

ru"s s ,onen erwensvarus @ Iise:NN oiscovtav cesc imen @

li e 5 l W@ l Of O l 0'2!@l NA l Q'Ql Operator observation l 8 jny,y eyjr,,,, '3 ** **

  • so
    • uasse :n aettese toone,e, aett4se @

l' i8I i Zl @ (,Jd g l amou=ron NA cnvvw l@ l NA g

'se=se=,JLunesua li171l0-l0 l0 g ,s:g l..c.,,,c @

-e.

NA  ;

' .amo

.u ..d'..uJ a2sco,-o @

li4:1lnInlol@l NA I

  1. <** **:ls'NN;2 *"" @ NA Ii i o. l, W@l

.' I ea

.veucw '#" "'C"'"

c'Sca'm ca

, ,,' y NA I lifIi11 iIeil

> ee is ,, ,,

asaus es pauAssa J. F. Kutzer (704) 373-7139 8202160395 820129 PDR ADOCK 05000270 S PDR