ML20034E500

From kanterella
Jump to navigation Jump to search
Memo to File Mesa Assessment Locations Summary Table 2
ML20034E500
Person / Time
Site: San Onofre  
Issue date: 05/28/2015
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034E500 (1)


Text

Summary of Affected Areas at the Mesa Table

Location Event Number Description Data Gaps or Sensitivity Concerns Approximate Size (square meters)

Area Remains Intact Included in Confirmatory Survey Plan

a.

Mesa Intersection 1

Contaminated excavation material from Unit 1 was dumped and subsequently removed.

No 2500 Yes No (1)

b.

Old Highway 101 Landfill 2

Non-contaminated excavation from Unit 1 had been transferred during the late 1970s. The Mesa Lease never included the area of the Old Highway 101 Landfill and there was never any indication of contamination as a result of early Unit 1 soil excavation. It is included in this assessment only for completeness.

No 2500 Yes No (1)

c.

Lower Mesa 1, 3, 4, and 5 Former site of the GRIP Facility/STAR Yard and the Fab Shop/Unit 1 Sleeving Mockup Training Facility. Contaminated items were discovered there during the 1980s. That location is not a part of the current Mesa. The area has been re-contoured and re-purposed by the Navy.

Yes N/A No No (2)

d.

Bechtel Warehouse B 4

Only one item was discovered with low level fixed contamination and no removable activity. No potential for spread of contamination. Further, the warehouse has been removed and replaced with a new building.

No N/A No No (2)

e.

Paint/Sandblast Yard 4

Only three items with low levels of fixed contamination and no removable contamination were found. No potential for spread of contamination. Further, the Paint Shop and Yard were relocated and the area re-purposed.

No N/A No No (2)

f.

Edison Warehouse, Building W-50 4

Seven contaminated items were discovered. Two of the items contained removable activity.

No 14,000 Yes Yes

g.

Units 2 and 3 Laydown 4

Sixty-seven contaminated items were discovered. Potential exposure to weather.

Yes 15,000 Yes Yes

h.

STAR Yard and Ameron Laydown 4 and 6 where the majority of inadvertently released contaminated items were discovered. More than 140 contaminated items were found there. Potential exposure to weather.

Yes 35,000 - 50,000 Yes Yes

i.

Mesa Salvage Yard 7

Only three items with low level fixed contamination and no removable activity were found. The area was later included as the western end of Camp Mesa.

No 6,000 Yes Yes

j.

Seaweed Drying Pad 8

Benthic material collected at the site was de-watered there before disposal. The material deposited there was free of detectable plant produced radionuclides. The area is included in this assessment only for completeness.

No 2500 No No

k.

Classroom 105, Building G-48 9

Personnel interviews revealed an event involving a damaged exempt Cl-36 that required decontamination of the room. No documentation exists for this event.

Yes 60 Yes Yes

l.

HP Lab, Building E-50 9

Personnel interview revealed the existence of a floor safe used to store training radioactive check sources in what is now known as the Joint Operation Center (JOC.) No documentation exists for this area.

Yes

<1 Yes Yes

m.

Mesa Paint Shop, Building G-44 10 A pair of pliers with fixed contamination was discovered there. No potential for spread of contamination.

No 1200 Yes No

n.

Sheet Metal Shop, Building G-40 11 A contaminated air hose was discovered in a sealed drum. No potential for spread of contamination.

No 1200 Yes No Notes:

1. Adequacy of the 1981 radiological surveys to be evaluated and documented by separate memorandum.
2. Since the area/building is no longer intact, additional surveys would not provide useful or meaningful information.