ML20034E305
Text
Sample ID:
142526 Type: RLSSS Type Detail: SAND Health Physics Sample Records Status: APPROVED
==
Description:==
140612BD02 PARKING LOT 4 CULVERT 2
~ommonl Resp Org: P4000 - PROJECT MANAGEMEt
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments: COUNT TO MDA I origin I Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Date: 06/12/14 13:04 Unknown Mat:
NO Mat. SizeNolume:
1118 GRAMS Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
PARKING LOT 4 CULVERT 2 I collecu~
Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA IRLSS~U Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes L Location I Unit: NON-UNIT RE Area: MS Stored By:,
Sample Loe: UNIT 1 COUNT ROOM Other: COUNT TO MDA Material Loe:
06/19/2014 12:14 Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
[ii' Elev: 100 Room:
Date: 00/00/00 00:00 Sample Date: 06/12/14 09:30 Sample SizeNolume: 1118 GRAMS Depth:
(in.)
Equip ID:
Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Health Physics Sample Records Sample ID:
142526 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
==
Description:==
140612BD02 PARKING LOT 4 CULVERT 2 I Analysis]
Geometry MCAID Quant.
Units Method FP/AP Lab Analysis By Date Mod ID Mod Date A_ 1 L_marinelli_sand -
1018 1118GR
.000 DYNES, WILLIAM J 06/12/14 14:03 lsotop~ Mode Activity Activity Uncert.
LLD/MDA
%Abund.
Atom. No.
Comments Mod Id Mod Date 0
K-40 NT 0.0000160S 1.89E-6 r
79.441%
40 0
1.033%
137 0
TL-208 NT 2.92E-7 1.038E-7 r
1.442%
208 0
PB-212 NT 5.292E-7 1.552E-7 r
2.613%
212 0
Bl-214 NT 6.864E-7 1.274E-7 r
3.389%
214 0
PB-214 -
NT 1.06E-6 2.9E-7 5.234%
214 0
AC-228 NT 1.387E-6 3.18E-7 r
6.848%
228 0
BE-7 AP 1.2106E-6 Iv 0.000%
7 0
54 0
MN-56 AP 1.2199E-7 IV 0.000%
56 0
C0-57 AP 8.7664E-8 Iv 0.000%
57 0
C0-58 AP 1.483E-7 Iv 0.000%
58 0
C0-60 AP 1.8557E-7 w
0.000%
60 0
SB-124 AP 1.2028E-7 jv 0.000%
124 0
SB-125 FP 2.5134E-7 Iv 0.000%
125 0
CS-134 FP 1.7713E-7 IV 0.000%
134 I Analysis Review Re-Analize:
No Lie Rad Mat Present:
No Reviewed: COOPER, TERRY L Date: 06/17/14 13:28 Hp Eng Rvw Reqd:
Yes Rad Mat Present:
Yes HP Notified Name:
Comments:
06/19/2014 12:14 Page 2 of 3
Health Physics Sample Records Sample ID:
142526 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140612BD02 PARKING LOT 4 CULVERT 2 I Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/17/14 13:29 Comments: Background Reference Sample /w environmental levels of Cs-137 Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/201412:14 Disposition Result Cs-137 is in the environment 1e-7uCi/gr range Final Approval Date: 06/17/14 13:29 Rasterized: r Page 3 of 3
SONGS HEALTH PHYSICS REPORT 12-JUN-2014 13:57
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140612BD02 PARKING LOT 4 CULVERT 2
- ID
- Start Time:
- Stop Time:
- Quantity 1018 12-JUN-2014 13:52:00 12-JUN-2014 13:52:00 1.11800E+03 GR Acquisition date: 12-JUN-2014 13:52:53 *
- Geometry A 11 marinelli sand 1 Operator: BILL Counting System IHPS Sample Number:
Analysis Library DYNES UlGSP 142526 HP NATURAL
>>>>> A -1922924
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:04:30.33 0 00:04:30.41 0.0%
1.00000E+OO 8.00000 PARAMETERS<<<<<
Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 12-JUN-2014 13:16
-1.11209E-01 4.99842E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1
77.32 30 13
- 1. 04 154.92 153 5 25.7 1.78E+OO BI-214 PB-212 PB-214 1
238.82 50 37
- 1. 48 477.99 473 13 29.0 6.76E-01 PB-212 1
294.74 36 17 2.09 589.85 587 13 27.1 3.26E+OO PB-214 1
352.02 36 9
- 1. 56 704.43 697 11 24.0 3.87E-01 PB-214 1
583.47 14 2
2.19 1167.39 1163 9 35.1 2.17E+OO TL-208 1
609.50 30 0
1.97 1219.47 1215 10 18.1 3.16E-01 BI-214 1
661. 70 18 4
1.65 1323.86 1320 8 30.5 l.30E+OO CS-137 1
911. 1 7 29 2
- 1. 92 1822. 81 1817 10 20.1 7.96E-02 AC-228 1
1460.94 86 0
- 1. 73 2922.18 2915 13 11.2 9.25E-01 K-40
Summary of Nuclide Activity Sample ID : 1018 Total number of lines in spectrum Number of unidentified lines Acquisition date 9
0 Page :
2 12-JUN-2014 13:52:53 Number of lines lenlatively identified by NID 9
100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uci/GR uCi/GR 1-Sigma Error
%Error Flags K-40 1.28E+09Y
- 1. 00 l.609E-05 l.609E-05 0.189E-05
- 11. 76 A
TL-208 3.05M
- 1. 96
- 1. 4 92E-07 2.920E-07 1.038E-07 35.54 A
PB-212 10.64H
- 1. 00 5.274E-07 5.292E-07 l.552E-07 29.33 A
BI-214 19.90M 1.11 6.158E-07 6.864E-07 1.274E-07 18.56 A
PB-214
- 26. SOM
- 1. 08 9.776E-07 l.060E-06 0.290E-06 27.38 A
AC-228 6.13H
- 1. 01 1.379E-06 1.387E-06 0.318E-06 22.95 A
Total Activity 1.974E-05 2.004E-05 Nuclide Type : fission Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags CS-137 30.00Y
- 1. 00 2.093E-07 2.093E-07 0.643E-07 30.73 A
Total Activity 2.093E-07 2.093E-07 Grand Total Activity:
l.995E-05 2.025E-05 Flags: "K" = Keyline not found "M" = Manually accepted "E" = Manually edited "A"= Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 1018 None Flags: "T" Tentatively associated Page :
3 Acquisition date 12-JUN-2014 13:52:53
Interference Report Sample ID : 1018 No interference correction performed Acquisition date Page :
4 12-JUN-2014 13:52:53
Nuclide Line Activity Report Page :
5 Sample ID : 1018 Acquisition date 12-JUN-2014 13:52:53 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 86 10.67*
4.482E-01
- 1. 609E-05 1.609E-05
- 11. 76 TL-208
- 72. 80 2.14 1.155E+OO ------
Line Not Found ------
74.97 3.60 1.239E+OO ------
Line Not Found ------
84.79
- 1. 27 l.578E+OO Line Not Found ------
252.45 ------
0.80 l.887E+OO Line Not Found ------
277.28 6.80
- 1. 783E+OO Line Not Found ------
510.61 ------
- 21. 60 1.121E+OO ------
Line Not Found ------
583.02 14 86.00*
9.947E-01 l.492E-07 2.920E-07 35.54 763.06 ------
- 1. 64 7.714E-01 ------
Line Not Found ------
860.30 ------
12.00 6.870E-01 ------
Line Not Found ------
PB-212 74.81 ------
10.50 1.233E+OO ------
Line Not Found ------
77.11 30 17.70 1.327E+OO 1.142E-06 1.145E-06 26.09 87.19 ------
6.27 l.650E+OO ------
Line Not Found ------
90.13 ------
- 1. 86 1.730E+OO ------
Line Not Found ------
115. 12 0.59 2.162E+OO ------
Line Not Found ------
238.58 50 43.60*
l.947E+OO 5.274E-07 5.292E-07 29.33 300.03 ------
3.34 1.694E+OO ------
Line Not Found ------
BI-214 76.86 30 0.58 1.327E+OO 3.484E-05 3.883E-05 26.39 79.29 ------
0.97 1.397E+OO ------
Line Not Found ------
609.31 30 46.10*
9.554E-01 6.158E-07 6.864E-07 18.56 665.44
- 1. 56 8.797E-01 ------
Line Not Found ------
768.35 ------
4.88 7.663E-01 ------
Line Not Found ------
806.16 ------
- 1. 23 7.315E-01 ------
Line Not Found ------
934.04 3.16 6.352E-01 ------
Line Not Found ------
1120. 27 15.00 5.391E-01 Line Not Found 1155.18 ------
- 1. 69 5.255E-01 ------
Line Not Found ------
1238.11 ------
5.92 4.976E-01 ------
Line Not Found ------
1280.95 ------
- 1. 47 4.855E-01 ------
Line Not Found ------
1377.66 ------
4.02 4.629E-01 ------
Line Not Found ------
1385. 30 0.78 4.614E-01 ------
Line Not Found ------
1401. 48
- 1. 39 4.583E-01 ------
Line Not Found ------
1407.97 2.48 4.571E-01 ------
Line Not Found ------
1509.22 ------
2.19 4.415E-01 ------
Line Not Found ------
1583.22 ------
- 0. 72 4.336E-01 ------
Line Not Found ------
1661. 26 1.15 4.280E-01 ------
Line Not Found ------
1729.58 ------
3.05 4.255E-01 ------
Line Not Found ------
1764.49 ------
15.90 4.249E-01 ------
Line Not Found ------
1847.41 ------
2.12 4.256E-01 ------
Line Not Found ------
PB-214 53.17 ------
1.10 3.707E-01 ------
Line Not Found ------
74.81 ------
6.52 1.233E+OO Line Not Found ------
77.11 30
- 11. 00 1.327E+OO
- 1. 837E-06 l.991E-06 26.13 87.19 ------
3.88 1.650E+OO Line Not Found ------
90.13 ------
1.15
- 1. 730E+OO Line Not Found ------
241. 92 7.46 l.933E+OO ------
Line Not Found ------
258.94 ------
0.55 l.859E+OO ------
Line Not Found ------
295.09 36 19.20*
1.714E+OO 9.776E-07 l.060E-06 27.38 351. 87 36 37.10 l.514E+OO 5.747E-07 6.231E-07 24.43 785.83
- 1. 09 7.498E-01 ------
Line Not Found ------
839.00 ------
0.59 7.038E-01 ------
Line Not Found ------
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 1018 Acquisition date 12-JUN-2014 13:52:53 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error AC-228 89.96 ------
3.40 1.726E+OO ------
Line Not Found ------
93.35 ------
5.60
- 1. 811E+OO Line Not Found ------
99.55 ------
- 1. 30 l.943E+OO ------
Line Not Found ------
105.36 ------
2.00 2.042E+OO ------
Line Not Found ------
108.99 ------
- 0. 67 2.093E+OO Line Not Found ------
129.03 ------
2.90 2.254E+OO Line Not Found ------
153.89 ------
0.84 2.276E+OO Line Not Found ------
209.39 ------
4.10 2.079E+OO Line Not Found ------
216.24 0.80 2.048E+OO Line Not Found ------
270.26 3.80 l.812E+OO ------
Line Not Found ------
328.07 3.50 1.593E+OO ------
Line Not Found ------
338.42 ------
12.40 l.558E+OO Line Not Found ------
340.94 0.52 1.550E+OO Line Not Found ------
409.62 2.20 l.348E+OO Line Not Found ------
463.10 ------
4.60
- 1. 219E+OO Line Not Found ------
562.65 ------
- 1. 01 1.028E+OO Line Not Found ------
581.52 3.00 9.978E-01 ------
Line Not Found ------
72 6. 63 0.87 8.087E-01 ------
Line Not Found ------
755.28
- 1. 32 7.791E-Ol ------
Line Not Found ------
772. 28
- 1. 09 7.625E-01 ------
Line Not Found ------
782.12 0.59 7.532E-01 ------
Line Not Found ------
794.79 ------
4.60 7.416E-01 ------
Line Not Found ------
830.59 ------
0.63 7.107E-01 ------
Line Not Found ------
835.60
- 1. 71 7.065E-01 Line Not Found ------
840.44 0.94 7.026E-01 ------
Line Not Found ------
904.29 ------
0.89 6.549E-01 ------
Line Not Found ------
911.16 29 29.00*
6.502E-01 l.379E-06 l.387E-06 22.95 964. 64 5.80 6.162E-01 ------
Line Not Found ------
968. 97 17.40 6.137E-01 ------
Line Not Found ------
1246.60 ------
0.57
- 4. 951E-01 ------
Line Not Found ------
1459.19 ------
- 1. 06 4.485E-01 ------
Line Not Found ------
1496.00 ------
- 1. 05 4.432E-01 ------
Line Not Found ------
1501.44 0.58 4.425E-01 ------
Line Not Found ------
1580.30 ------
0.71 4.338E-01 Line Not Found ------
1588.23 ------
3.60 4.331E-01 ------
Line Not Found ------
1630.47
- 1. 95 4.299E-01 ------
Line Not Found ------
1638.10 ------
0.54 4.294E-01 ------
Line Not Found ------
Nuclide Type: fission Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error CS-137 661.66 18 85.21*
8.845E-01 2.093E-07 2.093E-07 30.73 Flag: "*" = Keyline
Minimum Detectable Activity Report Sample ID : 1018 Nuclide BE-7 MN-54 MN-56 C0-57 C0-58 C0-60 SB-124 SB-125 CS-134 Bckgnd Sum
- 9.
- 3.
- 2.
- 12.
- 4.
- 3.
- 0.
- 3.
- 12.
Energy (keV) 477.61 834.83 846.81 122.06 810.79 1173.24 1690.98 427.88 604. 71 Acquisition date MDA (uCi/GR) 1.2106E-06 1.3606E-07 l.2199E-07 8.7664E-08 1.4830E-07 1.8557E-07 l.2028E-07 2.5134E-07
- 1. 7713E-07 Page :
7 12-JUN-2014 13:52:53