_______________

H_e_a_l_th_P_h~ys_i_cs Sample Records Sample ID:

142485 Type: RLSSS Type Detail: SAND

==

Description:==

140603BD 14 CAMP MESA# 16 CommonJ Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

[~_OJigin ~I Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Date: 06/05/1411:14 Unknown Mat:

NO Mat. SizeNolume:

1384 GRAMS Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00

==

Description:==

CAMP MESA# 16 Collectiori_J Sample Tech: DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA U~-L§§~__l Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes Location Unit: NON-UNIT RE Stored By:,

Sample Loe:

Other:

Material Loe:

06/19/2014 07:28 Area: MS Sample Date: 06/03/14 13:24 Sample SizeNolume: 1384 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3


~----------------*-

Health Physics Sample Rec_o_r_d_s ____________________ _

Sample ID:

142485 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 14 CAMP MESA# 16

!Analysis Geometry MCAID Quant.

Units Method FP/AP A_ 1 L_marinelli_sand -

30375 1384GR

.000

_ Isotope _ Mode Activity _ Activity Uncert.

LLD/MDA

%Abund.

0 K-40 NT 0.000015711.76E-6 0

TL-208 NT 2.773E-7 0

PB-212 NT 6.49E-7 0

Bl-214 NT 3.46E-7 0

PB-214 NT 5.209E-7 0

BE-7 AP 9.3678E-7 0

MN-54 AP 2.1128E-7 0

MN-56 AP 3.7864E-8 0

C0-57 AP 9-3818E-8 0

C0-58 AP 12255E-7 0

C0-60 AP 1.427E-7 0

SB-124 AP 5.8514E-8 0

SB-125 FP 2.7566E-7 0

CS-134 FP 4.0837E-8 0

CS-137 FP 1.3612E-7 Analysis Review Re-Analize:

No Hp Eng Rvw Reqd:

Yes Comments:

06/19/2014 07:28 7.76E-8 1.588E-7 1.177E-7 1.304E-7 r

89.755%

r 1.584%

3.708%

1.977%

2.976%

~

0.000%

~

0.000%

W' 0.000%

w 0.000%

w 0.000%

w 0.000%

~

0.000%

w 0.000%

w 0.000%

Iv 0.000%

Lie Rad Mat Present:

No Rad Mat Present:

Yes Lab Analysis By Date Atom. No.

40 208 212 214 214 7

54 56 57 58 60 124 125 134 137 PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:

06/05/14 16:28 Rasterized: r Mod ID Mod Date Mod Id Mod Date Date: 06/10/1415:43 Page 2 of 3

Sample ID:

142485 Type: RLSSS Type Detail: SAND

==

Description:==

1406038D 14 CAMP MESA# 16 Review/Approve ]

Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/19/2014 07:28 Health Physics Sample Re_c_o_r_d_s __ _

Status: APPROVED Rasterized: r HP Review Date: 06/10/14 15:43 Disposition Result: Sample contains only natural isotopes Final Aooroval Date: 06/10/1415:43 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 5-JUN-2014 16:24

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140603BD 14 CAMP MESA# 16

  • ID 30375 Acquisition date: 5-JUN-2014 16:21:45. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 5-JUN-2014 16:21:00.

5-JUN-2014 16:21:00.

Counting System 1.38400E+03 GR IHPS Sample Number:

A lL marinelli sand 1 Analysis Library Operator: MICHAEL PARK U2GSP 142485 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.41 0 00:03:00.45 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 08:09:

2.12659E-01 4.99528E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

238.73 54 27

1. 65 477.48 472 13 24.5 2.66E+OO PB-212 1

351. 71 28 6

1. 33 703.66 698 9 25.0 4.0lE-01 PB-214 1

583.13 15 2

1. 60 1166.95 1163 7 28.0 4.97E-01 TL-208 1

60 9. 4 6 15 3

1. 44 1219.64 1215 10 34.0 3.44E-01 BI-214 1

1460.67 82 0

1. 84 2923.70 2917 13 11. 2 6.05E-01 K-40

Summary of Nuclide Activity Sample ID : 30375 Total number of lines in spectrum Number of unidentified lines Page :

2 Acquisition date 5-JUN-2014 16:21:45 Number of lines tentatively identified by NID 5

0 5

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00
1. 571E-05
1. 571E-05 0.176E-05
11. 21 A

TL-208 3.05M

1. 64 1.694E-07 2.773E-07 0.776E-07 28.00 A

PB-212 10.64H

1. 00 6.474E-07 6.490E-07 1.588E-07 24.47 A

BI-214 19.90M

1. 08 3.200E-07 3.460E-07 l.177E-07 34.02 A

PB-214

26. 80M
1. 06 4.915E-07 5.209E-07 1.304E-07 25.04 KA Total Activity 1.733E-05 l.750E-05 Grand Total Activity :

l.733E-05 1.750E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30375 None Flags: "T" Tentatively associated Page :

3 Acquisition date 5-JUN-2014 16:21:45

Interference Report Sample ID : 30375 No interference correction performed Acquisition date Page :

4 5-JUN-2014 16:21:45

Nuclide Line Activity Report Page :

5 Sample ID : 30375 Acquisition date 5-JUN-2014 16:21:45 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 82 10.67*

5. 314E-01 l.571E-05
1. 571E-05
11. 21 TL-208 72.80 ------

2.14 1.594E+OO Line Not Found ------

74.97 3.60 1.692E+OO Line Not Found ------

84.79 ------

1. 27 2.058E+OO Line Not Found ------

252.45 ------

0.80 2.021E+OO Line Not Found ------

277.28 6.80 l.920E+OO Line Not Found ------

510.61 ------

21. 60 l.265E+OO Line Not Found ------

583.02 15 86.00*

1.128E+OO l.694E-07 2.773E-07 28.00 763.06 ------

1. 64 8.744E-01 Line Not Found ------

860.30 12.00 7.770E-01 Line Not Found ------

PB-212 74.81 ------

10.50 l.685E+OO Line Not Found ------

77.11 17.70

1. 782E+OO Line Not Found ------

87.19 ------

6.27 2.129E+OO Line Not Found ------

90.13

1. 86 2.206E+OO Line Not Found ------

115.12 ------

0.59 2.535E+OO Line Not Found ------

238.58 54 43.60*

2.082E+OO 6.474E-07 6.490E-07 24.47 300.03 3.34 l.834E+OO ------

Line Not Found ------

BI-214 76.86 ------

0.58

1. 772E+OO Line Not Found ------

79.29 ------

0.97 1.869E+OO Line Not Found ------

609.31 15 46.10*

l.084E+OO 3.200E-07 3.460E-07 34.02 665.44

1. 56 9.985E-01 ------

Line Not Found ------

768.35 4.88 8.685E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.283E-01 ------

Line Not Found ------

934.04 3.16 7.177E-01 Line Not Found ------

1120. 27 15.00 6.114E-01 ------

Line Not Found 1155. 18

1. 69 5.973E-01 ------

Line Not Found ------

1238.11 ------

5.92 5.697E-01 Line Not Found ------

1280.95 ------

1. 4 7 5.585E-01 Line Not Found ------

1377. 66 ------

4.02 5.401E-01 Line Not Found ------

1385.30 ------

0.78 5.391E-01 Line Not Found ------

1401.48

1. 39 5.370E-01 Line Not Found ------

1407.97 2.48 5.362E-01 Line Not Found ------

1509.22 2.19 5.292E-01 Line Not Found ------

1583.22 ------

0.72 5.296E-01 Line Not Found ------

1661.26 ------

1.15 5.351E-01 Line Not Found ------

1729.58 3.05 5.442E-Ol ------

Line Not Found ------

1764.49 ------

15.90 5.503E-01 Line Not Found ------

1847.41 ------

2.12 5.694E-01 ------

Line Not Found ------

PB-214 53.17 1.10 5.543E-01 Line Not Found ------

74.81 ------

6.52 1.685E+OO Line Not Found ------

77.11 ------

11. 00 1.782E+OO Line Not Found ------

87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 1.15 2.206E+OO Line Not Found ------

241. 92 7.46 2.067E+OO Line Not Found ------

258.94 ------

0.55 l.994E+OO Line Not Found ------

295.09 ------

19.20*

1.852E+OO Line Not Found ------

351.87 28 37.10 1.663E+OO 4.915E-07 5.209E-07 25.04 785.83

1. 09 8.495E-01 Line Not Found ------

839.00 0.59

7. 964E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30375 Acquisition date 5-JUN-2014 16:21:45 Flag: "*"

Keyline

Minimum Detectable Activity Report Sample ID 30375 Nuclide BE-7 MN-54 MN-56 C0-57 C0-58 C0-60 SB-124 SB-125 CS-134 CS-137 Bckgnd Sum

4.
8.
0.
12.
2.
1.
0.
3.
0.
3.

Energy (keV) 477.61 834.83 846.81 122.06 810.79 1332.50 602.73 427.88 795.87 661. 66 Acquisition date MDA (uCi/GR) 9.3678E-07 2.1128E-07 3.7864E-08 9.3818E-08 l.2255E-07 l.4270E-07 5.8514E-08 2.7566E-07 4.0837E-08 l.3612E-07 Page :

7 5-JUN-2014 16:21:45