ML20034E292

From kanterella
Jump to navigation Jump to search
Salvage 14-10 - Health Physics Sample Records
ML20034E292
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 06/19/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034E292 (9)


Text

Health Physic~ Sample Records Sample ID:

142484 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

1406038D 13, CAMP MESA# 14 ICommo!IJ Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

OriginJ Mat. SizeNolume:

1316 GRAMS.

==

Description:==

CAMP MESA #14

~ollecti~

Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MBA Comments:

COUNT TO MDA l_B._1-:_~§__~J Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes I Locatio!IJ Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/05/14 11 : 1 O Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/1413:16 Sample SizeNolume: 1760 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

Jv1' Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/19/2014 07:23 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records


~

Sample ID:

142484 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 13, CAMP MESA# 14 Analysis j I

~eometry MCAID Quant.

Units Method FP/AP Lab

_ Analysis By Date B_1L_marinelli_sand -

30367 1760GR

.000 Isotope Mode Activity

__ Activity Uncert.

LLD/MDA

%Abund.

0 K-40 NT 9.476E-6 0

TL-208 NT 3.979E-7 0

PB-212 NT 6.136E-7 0

Bl-214 NT 5.399E-7 0

PB-214 NT 4.999E-7 0

BE-7 AP 1.0044E-6 0

MN-54 AP 1.2096E-7 0

MN-56 AP 1.1612E-7 0

C0-57 AP 1.017E-7 0

C0-58 AP 1.5969E-7 0

C0-60 AP 4.7942E-8 0

SB-124 AP 1.122E-7 0

SB-125 FP 2.8895E-7 0

CS-134 FP 1.0367E-7 0

CS-137 FP 1.5784E-7 Analy~is Review Re-Analize:

No Hp Eng Rvw Reqd:

Yes Comments:

06/19/2014 07:23 1.352E-6 r

82.205%

9.16E-8 r

3.452%

1.568E-7 r

5.323%

1.488E-7 r

4.684%

1.204E-7 r

4.337%

w 0.000%

w 0.000%

w 0.000%

w 0.000%

~

0.000%

w 0.000%

w 0.000%

Iv" 0.000%

Iv" 0.000%

(v" 0.000%

Lie Rad Mat Present:

No Rad Mat Present:

Yes Atom. No.

40 208 212 214 214 7

54 56 57 58 60 124 125 134 137 PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:

06/05/1415:58 Rasterized: r Mod ID Mod Date Mod Id Mod Date Date: 06/10/1415:36 Page 2 of 3

H_e_a_lth Physics Sample Records Sample ID:

142484 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 13, CAMP MESA# 14 Review/~_e_erove I Reviewed: COOPER, TERRY L Comments: 338 keV peak is Ac-228 HP Ena Review Date: 06/10/1415:36 D_ispositi.9n _______ _

Disposition: OTHER Remarks:

Result: Sample contains only natural isotopes F_i_n_a_l A~P,P_r_o_v_a_l ___________ _

Approved: COOPER, TERRY L Comments:

06/19/2014 07:23 Date: 06/10/14 15:37 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:54

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140603BD 13, CAMP MESA# 14

  • ID 30367 Acquisition date: 5-JUN-2014 15:51:14. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 5-JUN-2014 15:51:00.

5-JUN-2014 15:51:00.

Counting System 1.76000E+03 GR IHPS Sample Number:

B 11 marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142484 HP NATURAL

>>>>> B #42-TP11663A

'PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.48 0 00:03:00.53 0.0%
1. OOOOOE+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 08:35:

-4.96372E-01 5.00067E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

238.83 57 36

1. 41 478.59 473 13 25.6 l.16E+OO PB-212 1

338.12 21 5

1. 81 677.15 672 10 29.1 2.85E-01 1

351.61 29 7

2.14 704.13 700 11 24.1 1.03E+OO PB-214 1

583.17 25 2

1. 22 1167.20 1162 9 23.0 4.36E-01 TL-208 l

609.03 24 8

2.21 1218.91 1215 8 27.6 1. 71E+OO BI-214 1

1460.92 50 0

2.18 2922.52 2916 12 14.3 3.23E-01 K-40

Unidentified Energy Lines Sample ID : 30367 Page :

3 Acquisition date : 5-JUN-2014 15:51:14 It 1

Energy Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err

%Eff Flags 338.12 21 5

1. 81 677.15 672 10 1.18E-01 29.1 l.44E+OO T

Flags: "T" = Tentatively associated

Interference Report Sample ID : 30367 No interference correction performed Acquisition date Page :

4 5-JUN-2014 15:51:14

Nuclide Line Activity Report Page :

5 Sample ID : 30367 Acquisition date 5-JON-2014 15:51:14 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 50 10.67*

4. 211E-01 9.476E-06 9.476E-06 14.27 TL-208
72. 80 2.14 1.070E+OO Line Not Found ------

74.97 3.60 1.156E+OO Line Not Found ------

84.79 ------

1. 27 1.506E+OO Line Not Found ------

252.45 ------

0.80 1.745E+OO ------

Line Not Found ------

277.28 6.80 l.645E+OO Line Not Found ------

510.61 ------

21. 60 l.035E+OO Line Not Found ------

583.02 25 86.00*

9.197E-01 2.727E-07 3.979E-07 23.03 763.06 ------

1. 64 7.126E-01 ------

Line Not Found ------

860.30 12.00 6.341E-01 Line Not Found ------

PB-212 74.81 ------

10.50 1.150E+OO Line Not Found ------

77.11 ------

17.70 1.239E+OO Line Not Found ------

87.19 ------

6.27 1.579E+OO Line Not Found ------

90.13 ------

1. 86 1.662E+OO Line Not Found ------

115. 12 0.59 2.085E+OO ------

Line Not Found ------

238.58 57 43.60*

l.804E+OO 6.124E-07 6.136E-07 25.55 300.03 ------

3.34 1.562E+OO Line Not Found ------

BI-214 76.86 ------

0.58 1.229E+OO Line Not Found ------

79.29 ------

0.97 1.320E+OO Line Not Found ------

609.31 24 46.10*

8.837E-01 5.082E-07 5.399E-07 27.57 665.44

1. 56 8.131E-01 ------

Line Not Found ------

7 68. 35 4.88 7.078E-01 ------

Line Not Found ------

806.16 ------

1. 23 6.754E-01 ------

Line Not Found ------

934.04 3.16 5.861E-01 ------

Line Not Found ------

1120. 27 15.00 4.982E-01 ------

Line Not Found ------

1155.18 ------

1. 69 4.860E-01 ------

Line Not Found ------

1238.11 ------

5.92 4.615E-01 ------

Line Not Found ------

1280.95 ------

1. 47 4.510E-01 ------

Line Not Found ------

1377.66 ------

4.02 4.323E-01 ------

Line Not Found ------

1385. 30 0.78

4. 311E-01 ------

Line Not Found ------

1401. 48

1. 39 4.287E-01 Line Not Found ------

1407.97 2.48 4.277E-01 Line Not Found ------

1509.22 2.19 4.165E-01 Line Not Found ------

1583.22

0. 72 4.120E-01 ------

Line Not Found ------

1661. 26 1.15 4.103E-01 ------

Line Not Found ------

1729.58 3.05 4.114E-01 Line Not Found ------

1764.49 ------

15.90 4.128E-01 ------

Line Not Found ------

1847.41 ------

2.12 4.187E-01 ------

Line Not Found ------

PB-214 53.17 1.10 2.929E-01 ------

Line Not Found ------

74.81 6.52 1.150E+OO Line Not Found ------

77.11

11. 00 1.239E+OO ------

Line Not Found ------

87.19 ------

3.88 1.579E+OO ------

Line Not Found ------

90.13 1.15 l.662E+OO Line Not Found ------

241.92 7.46 1.790E+OO Line Not Found ------

258.94 0.55

1. 718E+OO Line Not Found ------

295.09 ------

19.20*

1.579E+OO Line Not Found ------

351. 87 29 37.10 1.396E+OO 4.779E-07 4.999E-07 24.10 785.83 ------

1. 09 6.925E-01 Line Not Found ------

839.00 ------

0.59 6.497E-01 ------

Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30367 Acquisition date 5-JUN-2014 15:51:14 Flag: "*"

Keyline

Minimum Detectable Activity Report Page :

7 Sample ID 30367 Acquisition date 5-JUN-2014 15:51:14 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

5.

477.61 l.0044E-06 MN-54

2.

834.83 1.2096E-07 MN-56

2.

846.81 1.1612E-07 C0-57

17.

122.06 1.0170E-07 C0-58

4.

810.79

1. 5969E-07 C0-60
0.

1173.24 4.7942E-08 SB-124

4.

602.73 l.1220E-07 SB-125

4.

427.88 2.8895E-07 CS-134

3.

604.71 1.0367E-07 CS-137

5.

661.66 1.5784E-07