. ________________

H_ealth Physics Sample Rec._o_rd_s ________________________ ~

Sample ID:

142482 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

1406038D 11 CAMP MESA 10

~_mm~

Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MESA Reviewed: DYNES, WILLIAM J Comments:

L_Qri9ii:!J Mat. SizeNolume:

1261 GRAMS

==

Description:==

CAMP MESA# 10 Collection


~

Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA LRLSSS__J Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes l~cc!_!i.!'!!

Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/05/14 09:47 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/1413:00 Sample SizeNolume: 1261 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/19/2014 06:57 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records=-------------------------

Sample ID:

142482 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 11 CAMP MESA 10 l~r1~_!ysis Geometry ____ MCA ID Quant.

Units __

Method FP/AP B_1L_marinelli_sand -

30358 1261 GR

.000 Isotope Mode Activity Activity Uncert.

LLD/MDA

%Abund.

0 K-40 NT 0.0000108 1.98E-6 0

TL-208 NT 4.37E-7 0

PB-212 NT 8.948E-7 0

Bl-214 NT 7.567E-7 0

PB-214 NT 1.1 E-6 0

RA-224 NT 3.331E-6 0

BE-7 AP 1.1903E-6 0

MN-54 AP 1.9573E-7 0

MN-56 AP 2.1043E-7 0

C0-57 AP 1.1501 E-7 0

C0-58 AP 1.649E-7 0

C0-60 AP 1.7557E-7 0

SB-124 AP 1.1645E-7 0

SB-125 FP 3.9252E-7 0

CS-134 FP 1.0059E-7 0

CS-137 FP 1.5332E-7

~sis ~ev_~~~J Re-Analize:

No Hp Eng Rvw Reqd:

Yes Comments:

06/19/2014 06:57 1.044E-7 1.331E-7 1.487E-7 2.25E-7 1.006E-6 r

62.357%

r 2.523%

r 5.166%

r 4.369%

r 6.351%

r 19.233%

w 0.000%

w 0.000%

w 0.000%

w 0.000%

w 0.000%

w 0.000%

w 0.000%

w 0.000%

~

0.000%

~

0.000%

Lie Rad Mat Present:

No Rad Mat Present:

Yes Atom. No.

40 208 212 214 214 224 7

54 56 57 58 60 124 125 134 137 Lab Analysis By PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:

Rasterized: r Date Mod ID Mod Date 06/05/1415:13 Mod Id Mod Date Date: 06/10/14 14:56 Page 2 of 3

Health Physics Sample R_e_c_o_r_ds _______________________ _

Sample ID:

142482 Type: RLSSS Type Detail: SAND

==

Description:==

140603BD 11 CAMP MESA 10 Revi~w/~e.prove J Reviewed: COOPER, TERRY L Comments:

Status: APPROVED HP Review Date: 06/10/14 14:56 D_isposition Disposition: OTHER Remarks:

Result: Sample contains only natural isotopes

--~---------------------

Final Approval Approved: COOPER, TERRY L Comments:

06/19/2014 06:57 Date: 06/10/14 14:56 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:03

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140603BD 11 CAMP MESA 10

  • ID 30358 Acquisition date: 5-JUN-2014 14:59:52. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 5-JUN-2014 14:59:00.

5-JUN-2014 14:59:00.

Counting System l.26100E+03 GR IHPS Sample Number:

B lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142482 HP NATURAL

>>>>> B #42-TP11663A PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.46 0 00:03:00.49 0.0%

l.OOOOOE+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 08:35:

-4. 96372E-01 5.00067E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

238.33 59 5

2.48 477.60 472 10 14.9 2.45E+OO PB-212 1

241.71 20 4

1. 40 484.34 482 8 30.2 l.53E+OO RA-224 PB-214 1

295.27 26 2

1. 67 591. 46 588 7 20.4 2.21E-Ol PB-214 1

351. 7 4 30 2

1. 86 701.39 700 8 19.4 3.43E-01 PB-214 1

583.01 17 0

2.16 1166.87 1162 9 23.9 5.96E-01 TL-208 1

609.55 24 0

1. 77 1219.94 1215 9 19.6 l.42E-01 BI-214 1

1460.90 41 3

2.09 2922.49 2917 12 18.3 2.00E+OO K-40

Summary of Nuclide Activity Sample ID : 30358 Total number of lines in spectrum Number of unidentified lines Page :

2 Acquisition date 5-JUN-2014 14:59:52 Number of lines tentatively identified by NID 7

0 7

100.00%

Nuclide Type : natural Uncorrected Nuclide Hlife Decay uCi/GR K-40 1.28E+09Y

1. 00 1.0SOE-05 TL-208 3.05M
1. 69 2.592E-07 PB-212 10.64H
1. 00 8.925E-07 BI-214 19.90M
1. 09
6. 966E-07 PB-214
26. SOM
1. 06 1.034E-06 RA-224 3.66D
1. 00 3.330E-06 Total Activity 1.701E-05 Grand Total Activity :

1.701E-05 Flags: "K" "E"

Keyline not found Manually edited Decay Corr Decay Corr 1-Sigma uCi/GR 1-Sigma Error

%Error 1.0SOE-05 0.198E-05 18.32 4.370E-07

1. 044E-07 23.88 8.948E-07 l.331E-07 14.88 7.567E-07
1. 487E-07 19.65 1.lOOE-06 0.225E-06 20.43 3.331E-06 1.006E-06 30.21
1. 7 32E-05
1. 7 32E-05 Manually accepted "M"

"A" Nuclide specific abn. limit Flags A

A A

A A

A

Unidentified Energy Lines Sample ID : 30358 None Flags: "T" Tentatively associated Page :

3 Acquisition date 5-JUN-2014 14:59:52

Interference Report Sample ID : 30358 No interference correction performed Acquisition date Page :

4 5-JUN-2014 14:59:52

I Nuclide Line Activity Report Page :

5 Sample ID : 30358 Acquisition date 5-JUN-2014 14:59:52 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 41 10.67*

4. 211E-01 l.080E-05 1.080E-05 18.32 TL-208
72. 80 2.14 1.070E+OO Line Not Found ------

74.97 3.60 1.156E+OO Line Not Found ------

84.79 ------

1. 27 1.506E+OO Line Not Found ------

252.45 ------

0.80 1.745E+OO Line Not Found ------

277.28 ------

6.80

1. 645E+OO Line Not Found ------

510.61 ------

21. 60 l.035E+OO Line Not Found ------

583.02 17 86.00*

9.199E-01 2.592E-07 4.370E-07 23.88 763.06

1. 64 7.126E-01 ----..... -

Line Not Found ------

860.30 12.00 6.341E-Ol ------

Line Not Found ------

PB-212 74.81 ------

10.50 1.150E+OO Line Not Found ------

77.11 ------

17.70 1.239E+OO ------

Line Not Found ------

87.19 ------

6.27

1. 57 9E+OO Line Not Found ------

90.13

1. 86 1.662E+OO ------

Line Not Found ------

115.12 ------

0.59 2.085E+OO Line Not Found ------

238.58 59 43.60*

l.806E+OO 8.925E-07 8.948E-07 14.88 300.03 ------

3.34 1.562E+OO ------

Line Not Found ------

BI-214 76.86 ------

0.58 1.229E+OO Line Not Found ------

79.29 ------

0.97

1. 320E+OO Line Not Found ------

609.31 24 46.10*

8.830E-01

6. 966E-07 7.567E-07 19.65 665.44
1. 56 8.131E-01 ------

Line Not Found ------

768.35 4.88 7.078E-01 ------

Line Not Found ------

806.16 ------

1. 23 6.754E-01 ------

Line Not Found ------

934.04 3.16 5.861E-01 ------

Line Not Found ------

1120. 27 15.00 4.982E-01 Line Not Found ------

1155.18 ------

1. 69 4.860E-01 ------

Line Not Found ------

1238.11 ------

5.92 4.615E-01 ------

Line Not Found ------

1280.95 ------

1. 4 7 4.510E-01 ------

Line Not Found ------

1377. 66 4.02 4.323E-01 ------

Line Not Found ------

1385.30 ------

0.78

4. 311E-01 ------

Line Not Found ------

1401.48 ------

1. 39 4.287E-01 ------

Line Not Found ------

1407.97 2.48 4.277E-01 ------

Line Not Found 1509.22 ------

2.19 4.165E-01 ------

Line Not Found ------

1583.22 ------

0.72 4.120E-01 Line Not Found ------

1661. 26 ------

1.15 4.103E-01 Line Not Found ------

1729.58 ------

3.05 4.114E-01 Line Not Found ------

1764.49 ------

15.90 4.128E-Oi ------

Line Not Found ------

1847.41 ------

2.12 4.187E-01 ------

Line Not Found ------

PB-214 53.17 1.10 2.929E-01 ------

Line Not Found ------

74.81 ------

6.52 1.150E+OO Line Not Found ------

77.11 ------

11. 00 1.239E+OO ------

Line Not Found ------

87.19 ------

3.88 1.579E+OO ------

Line Not Found ------

90.13 1.15 l.662E+OO Line Not Found ------

241. 92 20 7.46

1. 791E+OO 1.741E-06 l.851E-06 30.21 258.94 0.55 1.718E+OO ------

Line Not Found ------

295.09 26 19.20*

1.579E+OO 1.034E-06

1. lOOE-06 20.43 351.87 30 37.10
1. 396E+OO 6.800E-07 7.231E-07 19.38 785.83
1. 09 6.925E-01 ------

Line Not Found ------

839.00 ------

0.59 6.497E-01 ------

Line Not Found ------

I Nuclide Line Activity Report (continued)

Sample ID : 30358 Acquisition date Page :

6 5-JUN-2014 14:59:52 Nuclide Type: natural Nuclide

.RA-224 Flag: "*"

Energy 83.79 240.76 Keyline Area 20

%Abn 0.20 3.90*

%Eff

1. 4 7 4E+OO 1.791E+OO Uncorrected Decay Corr uCi/GR uCi/GR Line Not Found 3.330E-06 3.331E-06 1-Sigma

%Error 30.21

Minimum Detectable Activity Report Page :

7 Sample ID 30358 Acquisition date 5-JUN-2014 14:59:52 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

4.

477.61 1.1903E-06 MN-54

3.

834.83 l.9573E-07 MN-56

3.

846.81 2.1043E-07 C0-57

10.

122.06 1.1501E-07 C0-58

2.

810.79 l.6490E-07 C0-60

1.

1332.50

1. 7557E-07 SB-124
2.

602.73 1.1645E-07 SB-125

4.

427.88 3.9252E-07 CS-134

1.

604. 71 l.0059E-07 CS-137

2.

661.66 l.5332E-07