Health Physics Sample Records Sample ID:
142478 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140603BD 7 CAMP MESA# 2 Common Resp Org: P4000 - PROJECT MANAGEMEt
Contact:
COOPER, TERRY L Reference ID:
Comments:
Reviewed: DYNES, WILLIAM J Comments:
Origin Mat. SizeNolume:
1611 GRAMS
==
Description:==
CAMP MESA# 2
@:ollection Sample Tech: DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA I.RLSSSl Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes fLocationl Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/05/14 09:25 Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/1412:30 Sample SizeNolume: 1611 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
Iv' Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Other:
Material Loe:
06/19/2014 06:40 Rasterized:
Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Sample ID:
142478 Type: RLSSS Type Detail: SAND
==
Description:==
140603BD 7 CAMP MESA# 2 Analysis Geometry A_ 1 L_marinelli_sand_
MCA ID Quant.
Units 30357 1611 GR Method lsoto~ Mode Activity Activity Uncert.
LLD/MDA 0
K-40 NT 0
TL-208 NT 0
PB-212 NT 0
Bl-214 NT 0
PB-214 NT 0
BE-7 AP 0
MN-56 AP 0
C0-57 AP 0
C0-58 AP 0
C0-60 AP 0
SB-124 AP 0
SB-125 FP 0
CS-134 FP 0
CS-137 FP I Analysis Review j 0.00001237 1.43E-6 3.643E-7 6.97E-8 6.257E-7 9.59E-8 7.037E-7 1.209E-7 6.873E-7 1.985E-7 7.5113E-7 1.0782E-7 3.2475E-8 6.5814E-8 1.0143E-7 4.5904E-8 6.1358E-8 2.233E-7 8.0981E-8 7.9919E-8 r
r r r Iv"
~
Iv" w
~
?" w w
~
w Health Physics Sample Records Status: APPROVED FP/AP Lab Analysis ~y
.000 PARK, MICHAEL C
%Abund.
Atom. No.
Comments 83.859%
40 2.470%
208 4.242%
212 4.771%
214 4.659%
214 0.000%
7 0.000%
54 0.000%
56 0.000%
57 0.000%
58 0.000%
60 0.000%
124 0.000%
125 0.000%
134 0.000%
137 Re-Analize:
No Lie Rad Mat Present:
No Reviewed: COOPER, TERRY L HP Notified Name:
Hp Eng Rvw Reqd:
Yes Rad Mat Present:
Yes Comments:
06/19/2014 06:40 Rasterized: r Date Mod ID Mod Date 06/05/14 15:13 Mod Id Mod Date Date: 06/10/1414:40 Page 2 of 3
Sample ID:
142478 Type: RLSSS Type Detail: SAND
==
Description:==
1406038D 7 CAMP MESA# 2 I Review/Approve I Reviewed: COOPER, TERRY L Comments:
Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/2014 06:40 Health Physics Sample Records Status: APPROVED Rasterized: J HP Eng Review Date: 06/10/1414:40 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/1414:40 Page 3 of 3
SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:02
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140603BD 7 CAMP MESA# 2
- ID 30357 Acquisition date: 5-JUN-2014 14:59:24. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 5-JUN-2014 14:59:00.
5-JUN-2014 14:59:00.
Counting System 1.61100E+03 GR IHPS Sample Number:
A lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142478 HP NATURAL
>>>>> A #41-TP11679B PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.44 0 00:03:00.49 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 5-JUN-2014 08:09:
2.12659E-01 4.99528E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1
77.31 32 26
- 1. 34 154.35 152 8 34.1 3.31E+OO BI-214 PB-212 PB-214 1
238.46 61 9
- 1. 00 476.95 473 7 15.3 3.03E+OO PB-212 1
295.02 25 9
- 1. 40 590.16 586 9 28.9 9.96E-01 PB-214 1
351. 7 5 32 8
- 1. 32 703.74 698 9 23.5 5.05E-01 PB-214 1
583.12 25 0
2.53 1166. 92 1162 9 19.1 4.95E-01 TL-208 1
609.19 35 0
- 1. 89 1219.11 1213 11 17.2 5.04E-01 BI-214 1
1460.95 75 0
2.35 2924.25 2917 13 11. 6 4.95E-01 K-40
Summary of Nuclide Activity Sample ID : 30357 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :
2 5-JUN-2014 14:59:24 Number of lines tentatively identified by NID 7
0 7
100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 1.28E+09Y
- 1. 00
- 1. 237E-05
- 1. 237E-05 0.143E-05
- 11. 56 A
TL-208 3.05M
- 1. 52 2.402E-07 3.643E-07 0.697E-07 19.14 A
PB-212 10.64H
- 1. 00 6.244E-07 6.257E-07 0.959E-07 15.32 A
BI-214 19.90M
- 1. 07 6.584E-07 7.037E-07 1.209E-07 17.18 A
PB-214 26.80M
- 1. 05 6.542E-07 6.873E-07 l.985E-07 28.88 A
Total Activity l.454E-05
- 1. 4 7 5E-05 Grand Total Activity :
1.454E-05
- 1. 4 7 5E-05 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30357 None Flags: "T" Tentatively associated Acquisition date Page :
3 5-JUN-2014 14:59:24
Interference Report Sample ID : 30357 No interference correction performed Acquisition date Page :
4 5-JUN-2014 14:59:24
I Nuclide Line Activity Report Page :
5 Sample ID : 30357 Acquisition date 5-JUN-2014 14:59:24 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 75 10.67*
5.314E-01 1.237E-05
- 1. 237E-05
- 11. 56 TL-208
- 72. 80 2.14 1.594E+OO ------
Line Not Found ------
74.97 3.60 l.692E+OO ------
Line Not Found ------
84.79 ------
- 1. 27 2.058E+OO Line Not Found ------
252.45 ------
0.80
- 2. 021E+OO Line Not Found ------
277.28 6.80 l.920E+OO Line Not* Found ------
510.61
- 21. 60 1.265E+OO Line Not Found ------
583.02 25 86.00*
1.128E+OO 2.402E-07 3.643E-07 19.14 763.06
- 1. 64 8.744E-01 ------
Line Not Found ------
860.30 12.00 7.770E-01 ------
Line Not Found ------
PB-212 74.81 10.50 1.685E+OO Line Not Found ------
77.11 32 17.70 1.791E+OO 9.337E-07 9.357E-07 34.12 87.19 ------
6.27 2.129E+OO Line Not Found ------
90.13
- 1. 86 2.206E+OO ------
Line Not Found ------
115. 12 ------
0.59 2.535E+OO Line Not Found ------
238.58 61 43.60*
2.083E+OO 6.244E-07 6.257E-07 15.32 300.03 ------
3.34 1.834E+OO Line Not Found ------
BI-214 76.86 32 0.58 1.791E+OO 2.850E-05 3.045E-05 34.12 79.29 ------
0.97 l.869E+OO Line Not Found ------
609.31 35 46.10*
1.084E+OO 6.584E-07 7.037E-07 17.18 665.44
- 1. 56 9.985E-01 ------
Line Not Found ------
768.35 4.88 8.685E-01 ------
Line Not Found ------
806.16 ------
- 1. 23 8.283E-01 ------
Line Not Found ------
934.04 ------
3.16 7..177E-01 Line Not Found ------
1120.27 15.00 6.114E-01 Line Not Found ------
1155.18
- 1. 69 5.973E-01 Line Not Found ------
1238.11 ------
5.92 5.697E-01 Line Not Found ------
1280.95 ------
- 1. 47 5.585E-01 Line Not Found ------
1377. 66 4.02 5.401E-01 Line Not Found ------
1385.30 ------
0.78 5.391E-01 Line Not Found ------
1401.48
- 1. 39 5.370E-01 Line Not Found ------
1407.97 2.48 5.362E-01 Line Not Found ------
1509.22 2.19 5.292E-01 Line Not Found ------
1583.22 0.72
- 5. 296E-01 Line Not Found ------
1661. 26 1.15 5.351E-01 Line Not Found ------
1729.58 3.05 5.442E-01 Line Not Found ------
1764.49 ------
15.90 5.503E-01 Line Not Found ------
1847.41 ------
2.12 5.694E-01 ------
Line Not Found ------
PB-214 53.17 1.10 5.543E-01 ------
Line Not Found ------
74.81 ------
6.52 l.685E+OO Line Not Found ------
77.11 32
- 11. 00
- 1. 791E+OO 1.502E-06 1.579E-06 34.12 87.19 ------
3.88 2.129E+OO Line Not Found ------
90.13 1.15 2.206E+OO Line Not Found ------
241.92 7.46 2.067E+OO Line Not Found ------
258.94 0.55 1.994E+OO ------
Line Not Found ------
295.09 25 19.20*
1.853E+OO 6.542E-07 6.873E-07 28.88 351. 87 32 37.10 1.662E+OO 4.898E-07 5.146E-07 23.49 785.83
- 1. 09 8.495E-01 Line Not Found ------
839.00 0.59
- 7. 964E-01 Line Not Found ------
- J I
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 30357 Acquisition date 5-JUN-2014 14:59:24 Flag: "*"
Keyline
Minimum Detectable Activity Report Page :
7 Sample ID 30357 Acquisition date 5-JUN-2014 14:59:24 Bck:gnd Energy MDA Nuclide Sum
( k:eV)
(uCi/GR)
BE-7
- 3.
477.61
- 7. 5113E-07 MN-54
- 2.
834.83 l.0782E-07 MN-56
- 0.
846.81 3.2475E-08 C0-57
- 8.
122.06
- 6. 5814E-*08 C0-58
- 2.
810.79 l.0143E-07 C0-60
- 0.
1332.50 4.5904E-08 SB-124
- 1.
602.73 6.1358E-08 SB-125
- 3.
427.88 2.2330E-07 CS-134
- 2.
604.71 8.0981E-08 CS-137
- 1.
661.66 7.9919E-08