Text

Sample ID:

142468 Type: RLSSS Type Detail: SAND Health Physics Sample Records Status: APPROVED

==

Description:==

1405308D 05 STARYARD SURVEY PT 45

!Common~!

Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference JD:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

r Origin I

Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Date: 06/04/14 08:16 Unknown Mat:

NO Mat. SizeNolume:

2319 GRAMS Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00

==

Description:==

STARYARD SURVEY PT 45 Collection Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA RLSSS Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes

!Location I Unit: NON-UNIT RE Stored By:,

Sample Loe:

Other:

Material Loe:

06/18/201414:10 Area: MS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

Iv'"

Elev: 100 Room:

Date: 00/00/00 00:00 Sample Date: 05/30/1412:40 Sample SizeNolume: 2319 GRAMS Depth:

(in.)

Equip ID:

Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records Sample ID:

142468 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140530BD 05 STARYARD SURVEY PT 45 Analy~~

~eometry MCAID Quant.

Units Method FP/AP Lab Analysis By C_1L_marinelli_sand -

30342 2319GR

.000 PARK, MICHAEL C Isotope Mode Activity Activity Uncert.

LLD/MDA

%Abund.

Atom. No.

Comments 0

K-40 NT 0.000011371.12E-6 r

74.847%

40 0

TL-208 NT 2.497E-7 4.9E-8 r

1.644%

208 0

PB-212 NT 5.788E-7 8.34E-8 r

3.810%

212 0

Bl-214 NT 3.295E-7 8.04E-8 r

2.169%

214 0

PB-214 NT 3.767E-7 1.543E-7 r

2.480%

214 0

RA-224 NT 1.777E-6 7.49E-7 r

11.698%

224 0

AC-228 NT 5.092E-7 1.156E-7 r

3.352%

228 0

BE-7 AP 5.7064E-7 w

0.000%

7 0

MN-54 AP 9.2526E-8

~

0.000%

54 0

MN-56 AP 4.5197E-8 w

0.000%

56 0

C0-57 AP 6.2038E-8 Ii' 0.000%

57 0

C0-58 AP 6.8657E-8

~

0.000%

58 0

C0-60 AP 7.8697E-8 W"

0.000%

60 0

SB-124 AP 5.1748E-8 Iv' 0.000%

124 0

SB-125 FP 1.6637E-7 P"

0.000%

125 0

CS-134 FP 4.7757E-8 Iv' 0.000%

134 0

CS-137 FP 6.2288E-8 Ii' 0.000%

137 Analysis Review Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Comments:

06/18/201414:10 Rad Mat Present:

Yes Rasterized:

Date Mod ID Mod Date 06/04/14 15:48 Mod Id Mod Date Date: 06/10/1413:37 Page 2 of 3

Sample ID:

142468 Type: RLSSS Type Detail: SAND

==

Description:==

140530BD 05 STARYARD SURVEY PT 45

[ Review/Approve I Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/2014 14:10 Health Physics Sample Records Status: APPROVED Rasterized: r HP Review Date: 06/10/1413:37 Disposition Result Sample contains only natural isotopes Final Approval Date: 06/10/1413:37 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 4-JUN-2014 15:43

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140530BD 05 STARYARD SURVEY PT 45

  • ID 30342 Acquisition date: 4-JUN-2014 15:40:13. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 4-JUN-2014 15:40:00.

4-JUN-2014 15:40:00.

Counting System 2.31900E+03 GR IHPS Sample Number:

C lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142468 HP NATURAL

>>>>> C #41-TP11750A PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.45 0 00:03:00.50 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

.Sensitivity 3-JUN-2014 20:44:

-9.06479E-02 4.99783E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

128.41 59 50 6.80 257.11 250 18 30.3 2.35E+OO AC-228 3

238.43 80 15

1. 57 477.22 472 19 14.4 1.05E+00 PB-212 3

241. 51 22 11

1. 57 483.39 472 19 42.1 RA-224 PB-214 1

295.32 20 16

1. 47 591. 05 586 9 41. 0 l.47E+00 PB-214 1

338.17 19 12

1. 86 676.77 673 11 40.5 1.12E+OO AC-228 1

352.15 46 7

1. 50 704.73 700 10 18.2 8.13E-01 PB-214 1

583.28 26 0

2.23 1167.10 1162 11 19.6 5.18E-01 TL-208 1

609.36 25 5

2.07 1219.28 1214 9 24.4 8.87E-01 BI-214 1

911. 24 17 0

2.09 1823.11 1819 8 22.7 3.68E-01 AC-228 1

1460.89 104 0

1. 98 2922.34 2915 13 9.9 8.22E-01 K-40

Summary of Nuclide Activity Sample ID : 30342 Total number of lines in spectrum Number of unidentified lines Acquisition date 10 0

Page :

2 4-JUN-2014 15:40:13 Number of lines tentatively identified by NID 10 Nuclide Type : natural 100.00%

Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00 1.137E-05 l.137E-05
0. 112E-05
9. 8 6 A

TL-208 3.05M

1. 45 1.718E-07 2.497E-07 0.490E-07 19.63 A

PB-212 10.64H

1. 00 5.777E-07 5.788E-07 0.834E-07 14.41 A

BI-214 19.90M

1. 06 3.103E-07 3.295E-07 0.804E-07 24.41 A

PB-214 2 6. SOM

1. 05 3.603E-07 3.767E-07
1. 543E-07
40. 96 A

RA-224 3.66D

1. 00 1.777E-06 1.777E-06 0.749E-06 42.13 A

AC-228 6.13H

1. 00 5.076E-07 5.092E-07 1.156E-07 22.70 A

Total Activity 1.507E-05 l.519E-05 Grand Total Activity :

l.507E-05

1. 519E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30342 None Flags: "T" Tentatively associated Page :

3 Acquisition date 4-JUN-2014 15:40:13

Interference Report Sample ID : 30342 No interference correction performed Acquisition date Page :

4 4-JUN-2014 15:40:13

Nuclide Line Activity Report Page :

5 Sample ID : 30342 Acquisition date 4-JUN-2014 15:40:13 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 104 10.67*

5.560E-01 1.137E-05 l.137E-05 9.86 TL-208

72. 80 2.14 1.486E+OO ------

Line Not Found ------

74.97 3.60 1.577E+OO ------

Line Not Found ------

84.79 ------

1. 27 1.917E+OO ------

Line Not Found ------

252.45 ------

0.80 2.004E+OO Line Not Found ------

277.28 6.80 1.917E+OO ------

Line Not Found ------

510.61 ------

21. 60 l.298E+OO Line Not Found ------

583.02 26 86.00*

1.157E+OO

1. 718E-07 2.497E-07 19.63 763.06 ------
1. 64 8.934E-01 Line Not Found ------

860.30 ------

12.00 7.922E-01 ------

Line Not Found ------

PB-212 74.81 ------

10.50 l.570E+OO Line Not Found ------

77.11 ------

17.70 l.661E+OO Line Not Found ------

87.19 ------

6.27 1.983E+OO Line Not Found ------

90.13 ------

1. 86 2.055E+OO ------

Line Not Found ------

115. 12 0.59 2.376E+OO Line Not Found ------

238.58 80 43.60*

2.056E+OO 5.777E-07 5.788E-07 14.41 300.03 ------

3.34 l.843E+OO Line Not Found ------

BI-214 76.86 ------

0.58 1.651E+OO ------

Line Not Found ------

79.29 0.97 1.741E+OO ------

Line Not Found ------

609.31 25 46.10*

1. 112E+OO 3.103E-07 3.295E-07 24.41 665.44 ------
1. 56 1.023E+OO ------

Line Not Found ------

768.35 ------

4.88 8.873E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.454E-01 ------

Line Not Found ------

934.04 3.16 7.310E-01 Line Not Found ------

1120. 27 ------

15.00 6.242E-01 Line Not Found ------

1155.18 ------

1. 69 6.105E-01 ------

Line Not Found ------

1238.11 ------

5.92 5.846E-01 ------

Line Not Found ------

1280.95 ------

1. 47 5.747E-01 ------

Line Not Found ------

1377. 66 4.02 5.602E-01 ------

Line Not Found ------

1385. 30 0.78 5.595E-01 ------

Line Not Found ------

1401.48 ------

1. 39 5.583E-01 ------

Line Not Found ------

1407.97 2.48 5.578E-01 ------

Line Not Found ------

1509.22 ------

2.19 5.568E-01 ------

Line Not Found ------

1583.22 ------

0.72 5.628E-01 Line Not Found ------

1661. 26 ------

1.15 5.753E-01 ------

Line Not Found ------

1729.58 ------

3.05 5.918E-01 Line Not Found ------

1764.49 ------

15.90 6.023E-01 Line Not Found ------

1847.41 ------

2.12 6.331E-01 Line Not Found ------

PB-214 53.17 ------

1.10 5.203E-01 ------

Line Not Found ------

74.81 ------

6.52 1.570E+OO Line Not Found ------

77.11 ------

11. 00 1.661E+OO Line Not Found ------

87.19 ------

3.88 l.983E+OO Line Not Found ------

90.13 1.15 2.055E+OO ------

Line Not Found ------

241. 92 22 7.46 2.044E+OO 9.288E-07

9. 711E-07 42.13 258.94 0.55 1.981E+OO ------

Line Not Found ------

295.09 20 19.20*

l.858E+OO 3.603E-07

3. 7 67E-07
40. 96 351. 87 46 37.10 1.685E+OO 4.732E-07 4.948E-07 18.23 785. 83
1. 09 8.674E-01 Line Not Found ------

839.00 ------

0.59 8.122E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30342 Acquisition date 4-JON-2014 15:40:13 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error RA-224 83.79 ------

0.20 l.887E+OO ------

Line Not Found 240.76 22 3.90*

2.044E+OO l.777E-06 1.777E-06 42.13 AC-228 89.96 ------

3.40 2.051E+OO Line Not Found ------

93.35 ------

5.60 2.124E+OO Line Not Found ------

99.55 ------

1. 30 2.229E+OO Line Not Found ------

105.36 ------

2.00 2.301E+OO Line Not Found ------

108.99 ------

0.67 2.335E+OO Line Not Found ------

129.03 59 2.90 2.413E+OO 5.463E-06 5.481E-06 30.25 153.89 ------

0.84 2.377E+OO Line Not Found ------

209.39 4.10 2.168E+OO Line Not Found ------

216.24 0.80 2.141E+OO Line Not Found ------

270.26 ------

3.80 l.941E+OO Line Not Found ------

328.07 3.50 1.756E+OO Line Not Found ------

338.42 19 12.40 1.726E+OO 5.778E-07 5.797E-07 40.55 340.94 0.52

1. 718E+OO Line Not Found ------

409.62 2.20

1. 531E+OO Line Not Found ------

463.10

4. 60 1.401E+OO Line Not Found ------

562.65 ------

1. 01 1.195E+OO Line Not Found ------

581.52 ------

3.00 1.160E+OO ------

Line Not Found ------

72 6. 63 0.87 9.382E-01 ------

Line Not Found ------

755.28

1. 32 9.027E-01 ------

Line Not Found ------

772.28

1. 09 8.827E-01 ------

Line Not Found ------

782.12 0.59 8.716E-01 ------

Line Not Found ------

794.79 ------

4. 60 8.576E-01 Line Not Found ------

830.59 ------

0.63 8.205E-01 Line Not Found ------

835.60

1. 71 8.155E-01 Line Not Found ------

840.44 0.94 8.108E-01 Line Not Found ------

904.29 ------

0.89 7.542E-01 Line Not Found ------

911.16 17 29.00*

7.486E-01 5.076E-07 5.092E-07 22.70 964. 64 5.80 7.091E-01 ------

Line Not Found ------

968.97 17.40 7.061E-01 Line Not Found ------

1246.60 ------

0.57 5.825E-01 Line Not Found ------

1459.19 ------

1. 06 5.560E-01 Line Not Found ------

1496. 00

1. 05 5.563E-01 Line Not Found ------

1501. 44 ------

0.58 5.565E-01 Line Not Found ------

1580.30 ------

0. 71 5.624E-01 Line Not Found ------

1588.23 ------

3.60 5.634E-01 Line Not Found ------

1630.47

1. 95
5. 696E-01 Line Not Found ------

1638.10 ------

0.54 5.709E-01 Line Not Found ------

Flag: "*" = Keyline

I

\\*

Minimum Detectable Activity Report Page :

7 Sample ID 30342 Acquisition date 4-JUN-2014 15:40:13 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

4.

477.61 5.7064E-07 MN-54

4.

834.83 9.2526E-08 MN-56

0.

846.81 4.5197E-08 C0-57

13.

122.06 6.2038E-08 C0-58

2.

810.79 6.8657E-08 C0-60

1.

1173.24 7.8697E-08 SB-124

2.

602.73 5.1748E-08 SB-125

3.

427.88 l.6637E-07 CS-134

1.

604.71 4.7757E-08 CS-137

2.

661.66 6.2288E-08