ML20034E239

From kanterella
Jump to navigation Jump to search
Sy C-Hatch 9-20 - Health Physics Sample Records
ML20034E239
Person / Time
Site: San Onofre  
Issue date: 06/18/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034E239 (10)


Text

Sample ID:

142439 Type: RLSSS Type Detail: SAND

==

Description:==

1405288D 09 STAR 9-20 Dirt Sample Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments:

Reviewed: DYNES, WILLIAM J Comments:

I _origin I Mat. SizeNolume:

1000 ml

==

Description:==

STAR 02 SOIL SAMPLE l Collection I Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

Comments:

COUNT TO MDA l~RLSSS I Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes LLocationl Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 05/29/1411:30 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 05/28/1413:17 Sample SizeNolume: 1771 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

(\\7" Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth: 3" (in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/18/201411:51 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of3

Health Physics Sample Records Sample ID:

142439 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

1405288D 09 STAR 9-20 Dirt Sample Analysis Geometry MCAID Quant.

Units Method FP/AP A_1L_marinelli_sand -

30273 1771 GR

.000 Isotope Mode Activity Activity Uncert.

LLD/MDA

%Abund.

0 K-40 NT 8.814E-6 0

TL-208 NT 1.642E-7 0

PB-212 NT 3.369E-7 0

81-214 NT 4.786E-7 0

PB-214 NT 2.624E-7 0

RA-226 NT 2.11 E-6 0

U-235 NT 1.306E-7 0

BE-7 AP 6.8536E-7 0

MN-54 AP 6.2046E-8 0

MN-56 AP 8.0248E-8 0

C0-57 AP 7.0245E-8 0

C0-58 AP 1.1102E-7 0

C0-60 AP 4.1759E-8 0

SB-124 AP 9.0122E-8 0

SB-125 FP 2.3429E-7 0

CS-134 FP 7.8924E-8 0

CS-137 FP 7.2703E-8 I Analysis Review I Re-Analize:

No Hp Eng Rvw Reqd:

Yes Comments:

06/18/2014 11 :51 1.155E-6 r

71.678%

6.94E-8 r

1.335%

9.92E-8 r

2.740%

1.076E-7 r

3.892%

1.523E-7 r

2.134%

9.39E-7 r

17.159%

5.81E-8 r

1.062%

w 0.000%

~

0.000%

P' 0.000%

~

0.000%

w 0.000%

~

0.000%

~

0.000%

p-0.000%

~

0.000%

iv-0.000%

Lie Rad Mat Present:

No Rad Mat Present:

Yes Atom. No.

40 208 212 214 214 226 235 7

54 56 57 58 60 124 125 134 137 Lab Analysis By ABERNATHY, AGNES B Comments Reviewed: COOPER, TERRY L HP Notified Name:

Rasterized: r Date Mod ID Mod Date 05/29/1416:33 Mod Id Mod Date Date: 06/10/14 09:50 Page 2 of 3

Sample ID:

142439 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 09 STAR 9-20 Dirt Sample

!Review/Approve I Reviewed: COOPER, TERRY L Comments: Peak at 338 keV is Ac-228 Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/201411:51 Health Physics Sample Records Status: APPROVED Rasterized: r HP Eng Review Date: 06/10/14 09:51 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/14 09:51 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 29-MAY-2014 16:29

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

1405288D 09 STAR 9-20 DIRT SAMPLE

  • ID 30273 Acquisition date: 29-MAY-2014 16:26:04 *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 29-MAY-2014 16:26:00 29-MAY-2014 16:26:00 Counting System l.77100E+03 GR IHPS Sample Number:

A lL marinelli_sand_l Analysis Library Operator: AGNES ABERNATHY U2GSP 142439 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.43 0 00:03:00.48 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 28-MAY-2014 21:10 2.58874E-01 4.99485E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

76.95 28 34

1. 34 153.54 151 7 39.2 1. 21E+OO BI-214 PB-212 PB-214 1

186.03 19 14

1. 24 371. 92 367 10 44.5 1. 41E+OO U-235 RA-226 1

238.65 36 28

1. 66 477.29 474 8 29.5 8.63E+OO PB-212 1

295.45 11 7

1. 27 591.00 585 10 58.1 2.32E+OO PB-214 1

338.46 12 3

1. 31 677.10 674 6 34.6 4.78E-01 1

351. 87 34 3

1. 50 703.95 698 13 22.0 1.lOE+OO PB-214 1

583.59 13 7

1. 62 1167. 88 1164 8 42.3 4.16E-01 TL-208 1

60 9. 2 9 27 2

1. 45.1219. 34 1215 10 22.5 4.73E-01 BI-214 1

1460.81 59 0

2.06 2924.18 2919 10 13.1 1.07E+OO K-40

Summary of Nuclide Activity Sample ID : 30273 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 29-MAY-2014 16:26:04 Number of lines tentatively identified by NID 9

0 9

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 l.28E+09Y

1. 00 8.814E-06 8.814E-06 1.155E-06 13.11 A

TL-208 3.05M

1. 41 l.168E-07 l.642E-07 0.694E-07 42.26 A

PB-212 10.64H

1. 00 3.363E-07 3.369E-07 0.992E-07 29.45 A

BI-214 19.90M

1. 06 4.531E-07 4.786E-07
1. 07 6E-07 22.49 A

PB-214

26. SOM
1. 04 2.519E-07 2.624E-07 l.523E-07 58.05 A

RA-226 1600.00Y

1. 00 2.llOE-06
2. llOE-06 0.939E-06 44.47 A

U-235 7.04E+08Y

1. 00
1. 306E-07 l.306E-07 0.581E-07 44.47 A

Total Activity

1. 221E-05
1. 230E-05 Grand Total Activity :
1. 221E-05 l.230E-05 Flags: "K" Keyline not found

M" Manually accepted "E" = Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30273 Page :

3 Acquisition date : 29-MAY-2014 16:26:04 It 1

Energy 338.46 Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err

%Eff Flags 12 3

1.31 677.10 674 6 6.SlE-02 34.6 1.70E+OO T

Flags: "T" = Tentatively associated

Interference Report Sample ID : 30273 No interference correction performed Page :

4 Acquisition date 29-MAY-2014 16:26:04

Nuclide Line Activity Report Page :

5 Sample ID : 30273 Acquisition date 29-MAY-2014 16:26:04 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 59 10.67*

5.314E-Ol 8.814E-06 8.814E-06 13.11 TL-208

72. 80 2.14 l.594E+OO Line Not Found ------

74.97 3.60

1. 692E+OO Line Not Found ------

84.79 ------

1. 27 2.058E+OO ------

Line Not Found ------

252.45 ------

0.80 2.021E+OO Line Not Found ------

277.28 6.80 l.920E+OO Line Not Found ------

510.61 ------

21. 60 1.265E+OO Line Not Found ------

583.02 13 86.00*

1.127E+OO 1.168E-07 l.642E-07 42.26 763.06 ------

1. 64 8.744E-01 Line Not Found ------

860.30 12.00 7.770E-01 Line Not Found ------

PB-212 74.81 10.50 l.685E+OO Line Not Found ------

77.11 28 17.70 1.776E+OO 7.536E-07 7.549E-07 39.16 87.19 ------

6.27 2.129E+OO Line Not Found ------

90.13 ------

1. 86 2.206E+OO Line Not Found ------

115. 12 0.59 2.535E+OO Line Not Found ------

238.58 36 43.60*

2.082E+OO 3.363E-07 3.369E-07 29.45 300.03 ------

3.34 l.834E+OO Line Not Found ------

BI-214 76.86 28 0.58 1.776E+OO 2.300E-05 2.429E-05 39.16 79.29 ------

0.97 1.869E+OO Line Not Found ------

609.31 27 46.10*

l.084E+OO 4.531E-07 4.786E-07 22.49 665.44 ------

1. 56 9.985E-01 Line Not Found ------

768.35 ------

4.88 8.685E-01 Line Not Found ------

806.16 ------

1. 23 8.283E-01 Line Not Found ------

934.04 3.16 7.177E-01 Line Not Found ------

1120. 27 15.00 6.114E-01 Line Not Found ------

1155.18 ------

1. 69 5.973E-01 Line Not Found ------

1238.11 ------

5. 92 5.697E-01 Line Not Found ------

1280.95 ------

1. 47 5.585E-01 Line Not Found ------

1377.66 ------

4.02 5.401E-01 Line Not Found ------

1385. 30 ------

0.78 5.391E-01 ------

Line Not B"ound 1401.48 ------

1. 39 5.370E-01 Line Not Found ------

1407.97 2.48 5.362E-01 Line Not Found ------

1509.22 ------

2.19 5.292E-01 Line Not Found ------

1583.22 ------

0.72

5. 296E-01 ------

Line Not Found ------

1661.26 ------

1.15 5.351E-01 ------

Line Not Found ------

1729.58 ------

3.05 5.442E-01 ------

Line Not Found ------

1764.49 ------

15.90 5.503E-01 ------

Line Not Found ------

1847.41 ------

2.12 5.694E-01 Line Not Found ------

PB-214 53.17 1.10 5.543E-01 Line Not Found ------

74.81 ------

6.52 1.685E+OO Line Not Found ------

77.11 28

11. 00 1.776E+OO
1. 213E-06
1. 263E-06 39.16 87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 ------

1.15 2.206E+OO Line Not Found ------

241. 92 7.46 2.067E+OO Line Not Found ------

258.94 0.55 1.994E+OO Line Not Found ------

295.09 11 19.20*

l.851E+OO 2.519E-07 2.624E-07 58.05 351.87 34 37.10 l.662E+OO 4.598E-07 4.789E-07 22.04 785.83

1. 09 8.495E-01 ------

Line Not Found ------

839.00 0.59 7.964E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30273 Acquisition date 29-MAY-2014 16:26:04 Nuclide Type: natural Nuclide RA-226 U-235 Flag: "*"

Energy

81. 07 18 6.11
89. 96 93.35 105.36 109.18 143.79 163.38 185.74 194.96 202.13 205.33 Keyline Area 19 19

%Abn

%Eff 0.18 l.934E+OO 3.28*

2.339E+OO 3.36 2.201E+OO 5.50 2.279E+OO

1. 98 2.463E+OO
1. 50 2.498E+OO 10.50 2.533E+OO 4.70 2.453E+OO 53.00*

2.339E+OO 0.59 2.294E+OO

1. 00 2.257E+OO
4. 7 0 2.241E+OO Uncorrected Decay Corr 1-Sigma uCi/GR uCi/GR

%Error Line Not Found ------

2. llOE-06
2. llOE-06 44.47 Line Not Found ------

Line Not Found ------

Line Not Found ------

Line Not Found ------

Line Not Found ------

Line Not Found ------

l.306E-07 l.306E-07 44.47 Line Not Found ------

Line Not Found ------

Line Not Found ------

Minimum Detectable Activity Report Sample ID 30273 Nuclide BE-7 MN-54 MN-56 C0-57 C0-58 C0-60 SB-124 SB-125 CS-134 CS-137 Bckgnd Sum

3.
0.
1.
11.
3.
0.
0.
4.
2.
1.

Energy (keV) 477.61 834.83 846.81 122.06 810.79 1332. 50 1690.98 427.88 604. 71 661. 66 Acquisition date MDA (uCi/GR) 6.8536E-07 6.2046E-08 8.0248E-08 7.0245E-08 l.1102E-07 4.1759E-08 9.0122E-08 2.3429E-07 7.8924E-08 7.2703E-08 Page :

7 29-MAY-2014 16:26:04