Health Physics Sample Re::...::c::...::o:_::._rd=-s=-------------------------
Sample ID:
142475 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
1406038D 4 CULVERT# 7
~ommo_nJ Resp Org: P4000 - PROJECT MANAGEMEr
Contact:
COOPER, TERRY L Reference ID:
Comments:
Reviewed: DYNES, WILLIAM J Comments:
I_OrigLf!J Mat. SizeNolume:
1675 GRAMS
==
Description:==
CULVERT# 7 l~ollection I Sample Tech: DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA I RLSSS
~-~~
Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes
[hQcation_l Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/05/14 07:14 Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/14 08:11 Sample SizeNolume: 1821 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
~
Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Other:
Material Loe:
06/19/2014 08:19 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Health Physics Sample Records Sample ID:
142475 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140603BD 4 CULVERT# 7
[A11aly~
G~CJm!!_ry MCA ID Quant.
Units Method FP/AP Lab Analysis By C_1L_marinelli_sand -
30368 1821 GR
.000 PARK, MICHAEL C Isotope Mode Activity Activity Uncert. _
LLD/MDA
%Abund.
Atom. No.
Comments 0
K-40 NT 0.000011 1.38E-6 r
85.194%
40 0
TL-208 NT 2.051 E-7 6.16E-8 1.588%
208 0
PB-212 NT 4.561E-7 1.107E-7 3.532%
212 0
Bl-214 NT 4.495E-7 9.81E-8 r
3.481%
214 0
PB-214 NT 3.217E-7 6.81E-8 r
2.492%
214 0
AC-228 NT 4.793E-7 2.089E-7 r
3.712%
228 0
BE-7 AP 7.2411 E-7 Iv 0.000%
7 0
54 0
MN-56 AP 1.1021 E-7 Iv 0.000%
56 0
C0-57 AP 6.5355E-8 Ii' 0.000%
57 0
C0-58 AP 8.0406E-8 Ii' 0.000%
58 0
C0-60 AP 3.9305E-8 Ii' 0.000%
60 0
SB-124 AP 6.9481E-8 Ii' 0.000%
124 0
SB-125 FP 2.0265E-7 w
0.000%
125 0
CS-134 FP 8.0955E-8 Iv 0.000%
134 0
0.000%
137
[_Analysis Review I Re-Analize:
No Lie Rad Mat Present:
No Reviewed: COOPER, TERRY L HP Notified Name:
Hp Eng Rvw Reqd:
Yes Comments:
06/19/2014 08:19 Rad Mat Present:
Yes Rasterized: r Date Mod ID Mod Date 06/05/14 15:58 Mod Id Mod Date Date: 06/10/1414:36 Page 2 of 3
Sample ID:
142475 Type: RLSSS Type Detail: SAND
==
Description:==
140603BD 4 CULVERT# 7 R~view/~p_prove Reviewed: COOPER, TERRY L Comments:
Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/2014 08:19 Health Physics Sample Record-=-s ______________________ _
Status: APPROVED Rasterized: r HP Review Date: 06/10/1414:36 Disposition Result: Sample contains only natural isotopes Final Aooroval Date: 06/10/14 14:36 Page 3 of 3
SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:54
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140603BD 4 CULVERT# 7
- ID 30368 Acquisition date: 5-JUN-2014 15:51:37. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 5-JUN-2014 15:51:00.
5-JUN-2014 15:51:00.
Counting System l.82100E+03 GR IHPS Sample Number:
C 11 marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142475 HP NATURAL
>>>>> C #41-TP11750A PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.45 0 00:03:00.49 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 5-JUN-2014 08:14:
-l.39807E-01 4.99820E-01
- 1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1
238.67 50 28
- 1. 65 477.76 473 11 24.3 3.53E+OO PB-212 1
338.35 21 0
- 1. 89 677.17 674 7 20.7 2.26E-01 AC-228 1
352.14 23 0
1.18 704.77 701 7 21. 2 5.33E-01 PB-214 1
582.94 16 2
- 1. 63 1166.46 1163 8 30.0 l.28E+OO TL-208 1
609.60 26 2
2.45 1219.78 1215 10 21. 8 5.22E-01 BI-214 1
910.94 13 6
- 1. 54 1822.50 1817 9 43.6 1.lOE+OO AC-228 1
1460.99 79 5
2.07 2922.51 2916 11 12.5 9.35E-01 K-40
Summary of Nuclide Activity Sample ID : 30368 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :
2 5-JUN-2014 15:51:37 Number of lines tentatively identified by NID 7
0 7
100.00%
Nuclide Type : natural Uncorrected Nuclide Hlife Decay uCi/GR K-40 1.28E+09Y
- 1. 00 1.lOOE-05 TL-208 3.05M
- 1. 59
- 1. 2 90E-07 PB-212 10.64H
- 1. 00 4.550E-07 BI-214 19.90M
- 1. 08 4.176E-07 PB-214
- 26. SOM
- 1. 06 3.046E-07 AC-228 6.13H
- 1. 00 4.773E-07 Total Activity :
- 1. 279E-05 Grand Total Activity:
1.279E-05 Flags: "K" Keyline not found "E" = Manually edited Decay Corr Decay Corr 1-Sigma uCi/GR 1-Sigma Error
%Error
- 1. lOOE-05 0.138E-05 12.55 2.051E-07 0.616E-07 30.04 4.561E-07 1.107E-07 24.26 4.495E-07 0.981E-07 21.83 3.217E-07 0.681E-07 21.16 4.793E-07 2.089E-07 43.59 l.291E-05
- 1. 291E-05 Manually accepted "M"
"A" Nuclide specific abn. limit Flags A
A A
A KA A
Unidentified Energy Lines Sample ID : 30368 None Flags: "T" Tentatively associated Acquisition date Page :
3 5-JUN-2014 15:51:37
Interference Report Sample ID : 30368 No interference correction performed Acquisition date Page :
4 5-JUN-2014 15:51:37
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 30368 Acquisition date 5-JUN-2014 15:51:37 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error AC-228
- 89. 96 3.40 2.051E+OO Line Not Found ------
93.35 ------
5.60 2.124E+OO Line Not Found ------
99.55 ------
- 1. 30 2.229E+OO Line Not Found ------
105.36 ------
2.00 2.301E+OO Line Not Found ------
108.99 ------
0.67 2.335E+OO Line Not Found ------
129.03 ------
2.90 2.414E+OO Line Not Found ------
153.89 ------
0.84 2.377E+OO Line Not Found ------
209.39 ------
4.10 2.168E+OO Line Not Found ------
216.24 0.80 2.141E+OO Line Not Found ------
270.26 ------
3.80 1.941E+OO ------
Line Not Found ------
328.07 ------
3.50 1.756E+OO Line Not Found ------
338.42 21 12.40
- 1. 725E+OO 8.097E-07 8.129E-07 20.70 340.94 ------
0.52
- 1. 718E+OO Line Not Found ------
409.62 2.20 l.531E+OO Line Not Found ------
463.10 ------
4.60 l.401E+OO Line Not Found ------
562.65 ------
- 1. 01 1.195E+OO Line Not Found ------
581.52 ------
3.00 1.160E+OO Line Not Found ------
72 6. 63 0.87 9.382E-Ol ------
Line Not Found ------
755.28
- 1. 32 9.027E-01 ------
Line Not Found ------
772. 28
- 1. 09 8.827E-01 ------
Line Not Found ------
782.12 0.59
- 8. 716E-01 ------
Line Not Found ------
794.79 4.60 8.576E-01 ------
Line Not Found ------
830.59 ------
0.63 8.205E-Ol ------
Line Not Found ------
835.60
- 1. 71 8.155E-01 ------
Line Not Found ------
840.44 0.94 8.108E-01 ------
Line Not Found ------
904.29 0.89 7.542E-01 ------
Line Not Found ------
911.16 13 29.00*
7.489E-Ol 4.773E-07 4.793E-07 43.59 964.64 5.80 7.091E-01 ------
Line Not Found ------
968.97 17.40 7.061E-01 ------
Line Not Found ------
1246.60 0.57 5.825E-01 ------
Line Not Found ------
1459.19
- 1. 06 5.560E-01 ------
Line Not Found ------
1496.00
- 1. 05 5.563E-Ol ------
Line Not Found ------
1501. 44 0.58 5.565E-01 ------
Line Not Found ------
1580.30 ------
- 0. 71 5.624E-01 ------
Line Not Found ------
1588.23 3.60 5.634E-01 ------
Line Not Found ------
1630.47
- 1. 95
- 5. 696E-Ol Line Not Found ------
1638.10 0.54 5.709E-01 ------
Line Not Found ------
Flag: "*" = Keyline
r J
Minimum Detectable Activity Report Page :
7 Sample ID 30368 Acquisition date 5-JUN-2014 15:51:37 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 4.
477.61
- 7. 2411E-07 MN-54
- 6.
834.83 1.4203E-07 MN-56
- 3.
846.81 l.1021E-07 C0-57
- 9.
122.06 6.5355E-08 C0-58
- 1.
810.79 8.0406E-08 C0-60
- 0.
1332.50 3.9305E-08 SB-124
- 2.
602.73 6.9481E-08 SB-125
- 3.
427.88 2.0265E-07 CS-134
- 3.
604. 71 8.0955E-08 CS-137
- 5.
661.66 1.1972E-07