ML20034E220

From kanterella
Jump to navigation Jump to search
Culvert 5 - Health Physics Sample Records
ML20034E220
Person / Time
Site: San Onofre  
Issue date: 06/19/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034E220 (10)


Text

Health Physics Sample Records_~---------------------~

Sample ID:

142474 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 3 CULVERT 5 tc~°-'!l'!I~

Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

1 origtn***1 Mat. SizeNolume:

1658 GRAMS

==

Description:==

CULVERT 5 I Collection]

Sample Tech: DYNES, WILLIAM J Tritium Req:

No Instructions:

Comments:

COUNT TO MDA IRLs?s I Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes l!,Qca_!:l9.!!

Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/05/14 07:06 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/14 08:08 Sample SizeNolume: 1658 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/19/2014 08:16 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records Sample ID:

142474 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 3 CULVERT 5 LAnalysisl Geometry MCA ID Quant.

Units Method FP/AP A_ 1 L_marinelli_sand_

30372 1658GR

.000 Isotope Mode

.. Activity Activity Uncert.

LLD/MDA

%Abund.

0 K-40 0

TL-208 0

PB-212 0

Bl-214 0

PB-214 0

BE-7 0

MN-54 0

MN-56 0

C0-57 0

C0-58 0

C0-60 0

SB-124 0

SB-125 0

CS-134 0

CS-137 NT 0.00001367 1.49E-6 NT 2.193E-7 7.88E-8 NT 3.697E-7 8.23E-8 NT 5.234E-7 1.072E-7 NT 2.944E-7 1.556E-7 AP 4.7897E-7 AP 8.3025E-8 AP 1.4038E-7 AP 7.0589E-8 AP 1.1244E-7 AP 1.2135E-7 AP 7.8296E-8 FP 2.4951E-7 FP 4.6653E-8 FP 1.4004E-7 Analysis ~~iew.

Re-Analize:

No Hp Eng Rvw Reqd:

Yes Comments:

06/19/2014 08:16 r

90.669%

r 1.455%

r 2.452%

r 3.472%

r 1.953%

Iv 0.000%

~

0.000%

w 0.000%

Iv 0.000%

Iv 0.000%

Iv' 0.000%

Iv 0.000%

Iv 0.000%

lv7 0.000%

lv7 0.000%

Lie Rad Mat Present:

No Rad Mat Present:

Yes Atom. No.

40 208 212 214 214 7

54 56 57 58 60 124 125 134 137 Lab

---~alysis By PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:

Rasterized: r Date Mod ID Mod Date 06/05/1416:18 Mod Id Mod Date Date: 06/10/1414:33 Page 2 of 3

H_e_a_l_th_P_h~y_si_cs Sample Records ______________________ _

Sample ID:

142474 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 3 CULVERT 5 Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/10/1414:35 Comments: 218 keV peak is not from a plant-produced radionuclide Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/19/2014 08:16 Disposition Result: Sample contains only natural isotopes Final Aooroval Date: 06/10/1414:35 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 5-JUN-2014 16:15

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140603BD 3 CULVERT 5

  • ID 30372 Acquisition date: 5-JUN-2014 16:12:48. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 5-JUN-2014 16:12:00.

5-JUN-2014 16:12:00.

Counting System l.65800E+03 GR IHPS Sample Number:

A lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142474 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.43 0 00:03:00.46 0.0%

l.OOOOOE+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 08:09:

2.12659E-01 4.99528E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

76.09 47 21 5.20 151.90 145 12 24.0 4.64E+OO BI-214 1

218.08 14 6

1. 68 436.14 433 9 41. 9 7.07E-01 1

238.66 37 10

1. 21 477.35 473 8 22.3 1.04E+OO PB-212 1

294.99 11 9

1. 32 590.11 586 7 52.8 3.00E+OO PB-214 1

351. 86 24 4

1. 58 703. 96 700 8 24.8 8.23E-01 PB-214 1

583.07 14 5

2.04 1166.82 1161 9 35.9 6.34E-01 TL-208 1

609.24 27 0

1. 84 1219.21 1212 13 20.5 5.25E-01 BI-214 1

1460.92 86 0

1. 92 2924.20 2918 11 10.9 3.55E-01 K-40

Summary of Nuclide Activity Sample ID : 30372 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 5-JUN-2014 16:12:48 Number of lines tentatively identified by NID 8

1 7

87.50%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 l.28E+09Y

1. 00 1.367E-05 1.367E-05 0.149E-05 10.87 A

TL-208 3.05M

1. 66 1.325E-07 2.193E-07 0.788E-07 35.93 A

PB-212 10.64H

1. 00 3.687E-07 3.697E-07 0.823E-07 22.26 A

BI-214 19.90M

1. 08 4.833E-07 5.234E-07 1.072E-07 20.49 A

PB-214 26.80M

1. 06 2.775E-07 2.944E-07
1. 556E-07 52.83 A

Total Activity

1. 4 94E-05 1.508E-05 Grand Total Activity :

1.494E-05 1.508E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30372 Page :

3 Acquisition date : 5-JUN-2014 16:12:48 It 1

Energy 218.08 Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err

%Eff Flags 14 6

1.68 436.14 433 9 7.96E-02 41.9 2.18E+OO Flags: "T" = Tentatively associated

Interference Report Sample ID : 30372 No interference correction performed Acquisition date Page :

4 5-JUN-2014 16:12:48

Nuclide Line Activity Report Page :

5 Sample ID : 30372 Acquisition date 5-JUN-2014 16:12:48 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 86 10.67*

5. 314E-01 1.367E-05 l.367E-05 10.87 TL-208
72. 80 2.14
1. 594E+OO ------

Line Not Found ------

74.97 3.60 1.692E+OO Line Not Found 84.79 ------

1. 27 2.058E+OO Line Not Found ------

252.45 ------

0.80 2.021E+OO Line Not Found ------

277.28 6.80 l.920E+OO Line Not Found ------

510.61 ------

21. 60 l.265E+OO Line Not Found 583.02 14 86.00*

1.128E+OO l.325E-07 2.193E-07 35.93 763.06 ------

1. 64 8.744E-01 ------

Line Not Found ------

860.30 12.00 7.770E-01 ------

Line Not Found ------

PB-212 74.81 10.50 l.685E+OO Line Not Found ------

77.11 ------

17.70 1.782E+OO Line Not Found 87.19 ------

6.27 2.129E+OO Line Not Found ------

90.13

1. 86 2.206E+OO Line Not Found ------

115. 12 0.59 2.535E+OO Line Not Found ------

238.58 37 43.60*

2.082E+OO 3.687E-07 3.697E-07 22.26 300.03 ------

3.34 1.834E+OO Line Not Found ------

BI-214 7 6. 8 6 47 0.58

1. 740E+OO 4.207E-05 4.557E-05 23.98 7 9. 2 9 ------

0.97 1.869E+OO Line Not Found ------

609.31 27 46.10*

l.084E+OO 4.833E-07 5.234E-07 20.49 665.44

1. 56 9.985E-01 ------

Line Not Found ------

768.35 ------

4.88 8.685E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.283E-01 ------

Line Not Found ------

934.04 3.16 7.177E-01 Line Not Found ------

1120.27 15.00 6.114E-01 Line Not Found ------

1155. 18

1. 69 5.973E-01 Line Not Found ------

1238.11 ------

5.92 5.697E-01 ------

Line Not Found ------

1280.95 ------

1. 47 5.585E-01 ------

Line Not Found ------

1377.66 ------

4.02 5.401E-01 ------

Line Not Found ------

1385.30 ------

0.78

5. 391E-01 ------

Line Not Found ------

1401.48 ------

1. 39 5.370E-01 ------

Line Not Found ------

1407.97 ------

2.48 5.362E-01 Line Not Found ------

1509.22 ------

2.19 5.292E-01 ------

Line Not Found ------

1583.22

0. 72 5.296E-01 Line Not Found ------

1661. 26 1.15 5.351E-01 Line Not Found ------

1729.58 ------

3.05 5.442E-01 ------

Line Not Found ------

1764.49 ------

15.90 5.503E-Ol ------

Line Not Found ------

1847.41 ------

2.12 5.694E-01 ------

Line Not Found ------

PB-214 53.17 1.10 5.543E-01 ------

Line Not Found ------

74.81 ------

6.52 1.685E+OO Line Not Found ------

77.11 ------

11. 00 1.782E+OO Line Not Found ------

87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 ------

1.15 2.206E+OO Line Not Found ------

241. 92 7.46 2.067E+OO Line Not Found ------

258.94 0.55 l.994E+OO Line Not Found ------

295.09 11 19.20*

1.853E+OO 2.775E-07 2.944E-07 52.83 351.87 24 37.10 1.662E+OO 3.449E-07 3.659E-07 24.77 785.83 ------

1. 09 8.495E-01 ------

Line Not Found ------

839.00 ------

0.59

7. 964E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30372 Acquisition date 5-JUN-2014 16:12:48 Flag: "*"

Keyline

Minimum Detectable Activity Report Page :

7 Sample ID 30372 Acquisition date 5-JUN-2014 16:12:48 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

1.

477.61 4.7897E-07 MN-54

1.

834.83 8.3025E-08 MN-56

4.

846.81 l.4038E-07 C0-57

10.

122.06 7.0589E-08 C0-58

3.

810.79 1.1244E-07 C0-60

1.

1332.50 1.2135E-07 SB-124

2.

602.73 7.8296E-08 SB-125

4.

427.88 2.4951E-07 CS-134

0.

604.71 4.6653E-08 CS-137

5.

661.66 1.4004E-07