Sample ID:

142498 Type: RLSSS Type Detail: SAND

==

Description:==

140605BD09 SOUTH LAY DOWN# 18 ICommon~I Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

Origin l Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/06/1410:07 Mat. SizeNolume:

1861 GRAMS Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00

==

Description:==

SOUTH LAY DOWN #18 ICollecti~

Sample Tech: DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA RLSSS Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

No Location Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Other: COUNT TO MDA Material Loe:

06/19/201410:17 Sample Date: 06/05/14 08:50 Sample SizeNolume: 1861 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records Sample ID:

142498 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

==

Description:==

140605BD09 SOUTH LAY DOWN# 18 I Analysis I Geometry MCAID Quant.

Units Method FP/AP Lab Analysis By Date Mod ID Mod Date B_1L_marinelli_sand -

30389 1861 GR

.000 NEESE, DAVID J 06/06/14 20:58

_ lsoto~ Mode Activity Activity Uncert.

LLD/MDA

%Abund.

Atom. No.

Comments Mod Id Mod Date 0

K-40 NT

0.0 0001361

1. 7E-6 r

87.043%

40 0

TL-208 NT 3.052E-7 6.81E-8 r

1.942%

208 0

PB-212 NT 5.262E-7 1.238E-7 r

3.348%

212 0

Bl-214 NT 6.478E-7 1.192E-7 r

4.122%

214 0

PB-214 NT 5.571E-7 2.092E-7 r

3.545%

214 0

BE-7 AP 9.6467E-7 Iv 0.000%

7 0

MN-54 AP 1.1442E-7 Iv 0.000%

54 0

MN-56 AP 1.5297E-7 Iv 0.000%

56 0

C0-57 AP 7.2437E-8 Iv 0.000%

57 0

C0-58 AP 3.255E-8 Iv 0.000%

58 0

C0-60 AP 1.3445E-7 IV 0.000%

60 0

SB-124 AP 1.1252E-7 Jv 0.000%

124 0

SB-125 FP 2.9902E-7 Iv 0.000%

125 0

CS-134 FP 1.1475E-7 Iv 0.000%

134 0

CS-137 FP 1.0462E-7 Iv 0.000%

137 Analysis Review I Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L Date: 06/11/14 07:12 Hp Eng Rvw Reqd:

Yes Rad Mat Present:

Yes HP Notified Name:

Comments:

06/19/2014 10:17 Page 2 of 3

Sample ID:

142498 Type: RLSSS Type Detail: SAND

==

Description:==

140605BD09 SOUTH LAY DOWN# 18 I ~Review/Approvej Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/19/201410:17 Health Physics Sample Records Status: APPROVED Rasterized:

HP Eng Review Date: 06/11/14 07:16 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/11/14 07:16 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 6-JUN-2014 20:51

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140605BD09 SOUTH LAY DOWN# 18

  • ID 30389 Acquisition date: 6-JUN-2014 20:48:21. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 6-JUN-2014 20:48:00.

6-JUN-2014 20:48:00.

Counting System l.86100E+03 GR IHPS Sample Number:

B 11 marinelli_sand_l Analysis Library Operator: DAVID NEEBE U2GSP 142498 HP NATURAL

>>>>> B #42-TP11663A PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.44 0 00:03:00.49 0.0%
1. OOOOOE+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 6-JUN-2014 20:09:

-4.40560E-01 5.00074E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

87.25 20 12

1. 35 175.36 172 7 36.6 2.94E+OO PB-212 PB-214 1

238.66 51 27

1. 00 478.13 473 10 23.5 5.21E-01 PB-212 1

295.33 20 14

1. 62 591.46 586 9 37.5 3.28E-01 PB-214 1

352.11 31 6

1. 95 704.99 701 8 21. 7 6.89E-01 PB-214 1

583.10 20 0

1. 58 1166.92 1162 9 22.3 5.90E-01 TL-208 1

609.31 31 0

2.13 1219.33 1215 10 18.4 6.09E-01 BI-214 1

1460.77 76 3

2.28 2922.06 2915 13 12.5 4.05E-01 K-40

Unidentified Energy Lines Sample ID : 30389 None Flags: "T" Tenlatively associated Page :

3 Acquisition date 6-JUN-2014 20:48:21