ML20034E212
Text
Sample ID:
142497 Type: RLSSS Type Detail: SAND
==
Description:==
140605BD08 SOUTH LAY DOWN# 16 Common Resp Org: P4000 - PROJECT MANAGEMEt
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:
Origin I Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/06/1410:00 Mat. SizeNolume:
2006 GRAMS Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
SOUTH LAY DOWN# 16 Collectiori]
Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes liocaJJonJ Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Other: COUNT TO MDA Material Loe:
06/19/2014 10:16 Sample Date: 06/05/14 08:30 Sample SizeNolume: 2006 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
~
Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of3
Health Physics Sample Records Sample ID:
142497 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
==
Description:==
140605BD08 SOUTH LAY DOWN# 16 Analysis Geometry MCAID Quant.
Units Method FP/AP Lab Analysis By Date Mod ID Mod Date
~~-----
A_ 1 L_marinelli_sand -
1012 2006GR
.000 DYNES, WILLIAM J 06/11/14 10:18 Isotope Mode Activity Activity Uncert.
LLD/MDA
%Abund.
Atom. No.
Comments Mod Id Mod Date 0
K-40 NT 0.00001345 1.54E-6 r
87.085%
40 0
TL-208 NT 3.243E-7 9.06E-8 r
2.100%
208 0
PB-212 NT 5.252E-7 1.168E-7 r
3.401%
212 0
Bl-214 NT 3.868E-7 1.182E-7 r
2.504%
214 0
PB-214 NT 7.584E-7 1.957E-7 r
4.910%
214 0
BE-7 AP 4.2257E-7 Iv 0.000%
7 0
54 0
MN-56 AP 1.184E-7 Iv 0.000%
56 0
C0-57 AP 9.8611 E-8 fi7' 0.000%
57 0
C0-58 AP 7.5934E-8 Iv 0.000%
58 0
C0-60 AP 4.275E-8 w
0.000%
60 0
SB-124 AP 8.1198E-8 w
0.000%
124 0
SB-125 FP 2.6125E-7 rv 0.000%
125 0
CS-134 FP 9.4846E-8 Iv 0.000%
134 0
137 C_ 1 L_marinelli_sand -
30390 1000 gr
.000 NEEBE, DAVID J 06/06/14 20:58 Isotope Mode Activity Activity Uncert.
LLD/MDA
%Abund.
Atom. No.
Comments Mod Id Mod Date 0
K-40 NT 0.00002544 2.16E-6 r
64.572%
40 0
TL-208 NT 7.222E-7 1.114E-7 r
1.833%
208 0
Bl-212 NT 3.104E-6 8.26E-7 r
7.879%
212 0
PB-212 NT 1.271E-6 1.88E-7 r
3.226%
212 0
Bl-214 NT 9.97E-7 1.699E-7 r
2.531%
214 0
PB-214 NT 3.086E-6 2.95E-7 r
7.833%
214 0
RA-226 NT 3.758E-6 1.939E-6 r
9.539%
226 0
AC-228 NT 7.868E-7 1.959E-7 r
1.997%
228 0
U-235 NT 2.326E-7 1.2E-7 r
0.590%
235 0
BE-7 AP 1.0392E-6 w
0.000%
7 06/19/2014 10:16 Page 2 of 3
Sample ID:
142497 Type: RLSSS Type Detail: SAND
==
Description:==
140605BD08 SOUTH LAY DOWN# 16
!Ana1ysisl Geom.-=--et_ry,__ __ ~
C_ 1 L_marinelli_sand_
Isotope Mode 0
MN-56 AP 0
C0-57 AP 0
C0-58 AP 0
C0-60 AP 0
SB-124 AP 0
SB-125 FP 0
CS-134 FP 0
CS-137 FP I Analysis Review MCA ID Quant.
Units
-~----
30390 1000gr Activity Activity Uncert.
1.4855E-7 1.6207E-7 1.3645E-7 1.4329E-7 1.5182E-7 9.778E-8 3.9874E-7 1.1969E-7 1.7652E-7 Method LLD/MDA iv iv w
Iv Iv Iv iv Iv Iv Health Physics Sample Records Status: APPROVED FP/AP
.000
%Abund.
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
Lab Atom. No.
54 56 57 58 60 124 125 134 137 Anal~!_~~_}'_
NEESE, DAVID J Comments Re-Analize:
No Lie Rad Mat Present:
No Reviewed: COOPER, TERRY L HP Notified Name:
Hp Eng Rvw Reqd:
Yes Comments:
Review/Approve Reviewed: COOPER, TERRY L Comments:
Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/2014 10:16 Rad Mat Present:
Yes HP Review Date: 06/11/1410:34 DiS!)OSition Result: Sample contains only natural isotopes Final Approval Date: 06/11/14 10:34 Rasterized:
Date Mod ID Mod Date 06/06/14 20:58 Mod Id Mod Date Date: 06/11/14 10:33 Page 3 of 3
SONGS HEALTH PHYSICS REPORT ll-JUN-2014 10:11
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140605BD08 SOUTH LAY DOWN# 16
- ID
- Start Time:
- Stop Time:
- Quantity 1012 ll-JUN-2014 10:08:00 ll-JUN-2014 10:08:00 2.00600E+03 GR Acquisition date: ll-JUN-2014 10:08:13 *
- Geometry A 11 marinelli sand 1 Operator: BILL Counting System IHPS Sample Number:
Analysis Library DYNES UlGSP 142497 HP NATURAL
>>>>> A -1922924
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.25 0 00:03:00.32 0.0%
1.00000E+OO 8.00000 PARAMETERS<<<<<
Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity ll-JUN-2014 09:11
-1. 07429E-01 4.99821E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1
238.70 60 25
- 1. 33 477.76 475 11 21. 8 1. 20E+OO PB-212 1
295.44 32 10
- 1. 32 591. 27 586 10 25.5 3.54E-01 PB-214 1
351.90 45 7
- 1. 81 704.21 700 9 17.9 4.18E-01 PB-214 1
583.30 26 7
2.29 1167.10 1163 10 27.3 6.82E-01 TL-208 1
609.45 21 7
- 1. 34 1219.42 1214 9 30.2 4.16E-01 BI-214 1
1460.83 86 0
2.23 2922.15 2917 12 10.9 7.35E-01 K-40
Summary of Nuclide Activity Sample ID : 1012 Total number of lines in spectrum Number of unidentified lines Page :
2 Acquisition date 11-JUN-2014 10:08:13 Number of lines tentatively identified by NID 6
0 6
100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 1.28E+09Y
- 1. 00 1.345E-05 l.345E-05 0.154E-05
- 11. 4 7 A
TL-208 3.05M
- 1. 45 2.232E-07 3.243E-07 0.906E-07 27.93 A
PB-212 10.64H
- 1. 00 5.242E-07 5.252E-07 1.168E-07 22.24 A
BI-214 19.90M
- 1. 06 3.644E-07 3.868E-07 1.182E-07 30.55 A
PB-214 26.SOM
- 1. 05 7.254E-07 7.584E-07 1.957E-07 25.81 A
Total Activity l.529E-05 l.544E-05 Grand Total Activity :
1.529E-05
- 1. 544E-05 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 1012 None Flags: "T" Tentatively associated Acquisition date Page :
3 ll-JUN-2014 10:08:13
Interference Report Sample ID : 1012 No interference correction performed Acquisition date Page :
4 ll-JUN-2014 10:08:13
Nuclide Line Activity Report Page :
5 Sample ID : 1012 Acquisition date 11-JUN-2014 10:08:13 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 86 10.67*
4.482E-01 l.345E-05
- 1. 345E-05
- 11. 4 7 TL-208
- 72. 80 2.14 1.155E+OO Line Not Found ------
74.97 3.60
- 1. 239E+OO Line Not Found ------
84.79 ------
- 1. 27 1.578E+OO Line Not Found ------
252.45 0.80 1.887E+OO Line Not Found ------
277.28 6.80 1.783E+OO Line Not Found ------
510.61
- 21. 60 1.121E+OO Line Not Found ------
583.02 26 86.00*
9.950E-01 2.232E-07 3.243E-07 27.93 763.06
- 1. 64 7.714E-01 ------
Line Not Found ------
860.30 12.00 6.870E-Ol ------
Line Not Found ------
PB-212 74.81 10.50 1.233E+OO Line Not Found ------
77.11 17.70 l.319E+OO Line Not Found ------
87.19 ------
6.27 l.650E+OO Line Not Found ------
90.13
- 1. 86 1.730E+OO Line Not Found ------
115.12 0.59 2.162E+OO Line Not Found ------
238.58 60 43.60*
l.948E+OO 5.242E-07 5.252E-07 22.24 300.03 3.34 l.694E+OO Line Not Found ------
BI-214 76.86 ------
0.58 1.310E+OO Line Not Found ------
79.29 ------
0.97 1.397E+OO Line Not Found ------
609.31 21 46.10*
9.555E-01 3.644E-07 3.868E-07 30.55 665.44
- 1. 56 8.797E-01 ------
Line Not Found ------
768.35 4.88 7.663E-01 ------
Line Not Found ------
806.16 ------
- 1. 23 7.315E-01 ------
Line Not Found ------
934.04 3.16 6.352E-01 ------
Line Not Found ------
1120. 27 15.00 5.391E-01 ------
Line Not Found ------
1155.18
- 1. 69 5.255E-01 ------
Line Not Found ------
1238.11 5.92 4.976E-01 ------
Line Not Found ------
1280.95 ------
- 1. 47 4.855E-01 Line Not Found ------
1377. 66 4.02 4.629E-01 ------
Line Not Found ------
1385.30 0.78 4.614E-01 Line Not Found ------
1401. 48
- 1. 39 4.583E-01 ------
Line Not Found ------
1407.97 2.48 4.571E-01 ------
Line Not Found ------
1509.22 ------
2.19 4.415E-01 ------
Line Not Found ------
1583.22 0.72 4.336E-01 ------
Line Not Found ------
1661. 26 1.15 4.280E-01 ------
Line Not Found ------
1729.58 ------
3.05 4.255E-01 ------
Line Not Found ------
1764.49 ------
15.90 4.249E-01 ------
Line Not Found ------
1847.41 ------
2.12 4.256E-01 ------
Line Not Found ------
PB-214 53.17 1.10 3.707E-01 ------
Line Not Found ------
74.81 6.52 1.233E+OO ------
Line Not Found ------
77.11 ------
- 11. 00 1.319E+OO ------
Line Not Found ------
87.19 ------
3.88 l.650E+OO Line Not Found ------
90.13 1.15
- 1. 730E+OO Line Not Found ------
241. 92 7.46 1.933E+OO ------
Line Not Found ------
258.94 0.55 1.859E+OO ------
Line Not Found ------
295.09 32 19.20*
1.712E+OO 7.254E-07 7.584E-07 25.81 351.87 45 37.10 1.515E+OO 5.990E-07 6.263E-07 18.47 785.83
- 1. 09 7.498E-01 ------
Line Not Found ------
839.00 0.59 7.038E-01 ------
Line Not Found ------
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 1012 Acquisition date ll-JUN-2014 10:08:13 Flag: "*"
Keyline
Minimum Detectable Activity Report Page :
7 Sample ID : 1012 Acquisition date ll-JUN-2014 10:08:13 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 1.
477.61
- 4. 2257E*-07 MN-54
- 2.
834.83 9.BlOOE-08 MN-56
- 3.
846.81 1.1840E-07 C0-57
- 23.
122.06 9.8611E-08 C0-58
- 1.
810.79 7.5934E-08 C0-60
- 0.
1332.50 4.2750E-08 SB-124
- 3.
602.73 8.1198E-08 SB-125
- 5.
427.88 2.6125E-07 CS-134
- 4.
604. 71 9.4846E-08 CS-137
- 4.
661.66 l.2398E-07