Text

Sample ID:

142509 Type: RLSSS Type Detail: SAND

==

Description:==

14060614BD 09 NORTH LAYDOWN # 19 LCo_mmo_11J Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments: COUNT TO MDA Origin_]

Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/09/14 09:01 Mat. SizeNolume:

1995 GRAMS Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00

==

Description:==

NORTH LA YDOWN # 19 I Collection Sample Tech: DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA lR_i,.s~_J Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes lLocation Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Other: COUNT TO MDA Material Loe:

06/19/2014 09:12 Sample Date: 06/06/14 12:05 Sample SizeNolume: 1995 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

ji7' Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Sample ID:

142509 Type: RLSSS Type Detail: SAND

==

Description:==

14060614BD 09 NORTH LAYDOWN # 19

~aly~~J Geometry_____ MCA ID Quant.

Units Method A_ 1 L_marinelli_sand_

30423 1995GR

_l~~_!9e~-- Mode Activity Activity Uncert.

LLD/MDA 0

K-40 NT 0

PB-212 NT 0

Bl-214 NT 0

PB-214 NT 0

AC-228 NT 0

BE-7 AP 0

MN-54 AP 0

MN-56 AP 0

C0-57 AP 0

C0-58 AP 0

C0-60 AP 0

SB-124 AP 0

SB-125 FP 0

CS-134 FP 0

CS-137 FP

~~is R~_~ew I 9.459E-6 4.986E-7 6.355E-7 6.374E-7 8.077E-7 5.8235E-7 1.3172E-7 2.6287E-8 7.6836E-8 6.7365E-8 1.0085E-7 5.168E-8 1.9471E-7 4.0754E-8 1.0646E-7 1.124E-6 9.46E-8 1.112E-7 1.576E-7 3.55E-7 r r r

~

~

~

~

W-W Iv

~

~

rv Health Physics Sample Records Status: APPROVED FP/AP Lab Analysis By

.000 NEESE, DAVID J

%Abund.

Atom. No.

Comments 78.575%

40 4.142%

212 5.279%

214 5.295%

214 6.709%

228 0.000%

7 0.000%

54 0.000%

56 0.000%

57 0.000%

58 0.000%

60 0.000%

124 0.000%

125 0.000%

134 0.000%

137 Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Rad Mat Present:

Yes Comments:

06/19/2014 09:12 Rasterized: r Date Mod ID Mod Date 06/09/14 20:43 Mod Id Mod Date Date: 06/11/14 08:13 Page 2 of 3

Sample ID:

142509 Type: RLSSS Type Detail: SAND

==

Description:==

140606148D 09 NORTH LAYDOWN # 19 Review/Approve Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/19/2014 09:12 Health Physics Sample Records Status: APPROVED Rasterized: r HP Eng Review Date: 06/11/14 08:14 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/11/14 08:14 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 9-JUN-2014 20:38

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

14060614DD 09 NORTII LAYDOWN # 19

  • ID 30423 Acquisition date: 9-JUN-2014 20:34:56. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 9-JUN-2014 20:34:00.

9-JUN-2014 20:34:00.

Counting System 1.99500E+03 GR IHPS Sample Number:

A 11 marinelli_sand_l Analysis Library Operator: DAVID NEEBE U2GSP 142509 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.43 0 00:03:00.47 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 9-JUN-2014 19:32:

2.30553E-01 4.99505E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

76.98 19 42

1. 24 153.65 153 5 57.1 3.24E+OO BI-214 PB-212 PB-214 1

238.67 60 22 1.16 477.35 473 8 19.0 1.59E+OO PB-212 1

295.22 28 5

1. 31 590.57 585 11 24.7 4.39F.-01 PB-214 1

337.99 40 10 2.06 676.20 672 12 21. 6 1. 72E+OO AC-228 1

352.04 35 12

1. 77 704.34 700 10 24.4 8. llE-01 PB-214 1

609.24 39 3

1. 58 1219.27 1214 10 17.5 2.65E-01 BI-214 1

969. 65 13 7

1. 40 1940.86 1935 9 43.9 3.58E-01 AC-228 1

1460. 55 71 0

1. 77 2923.75 2918 12 11. 9 2.34E-01 K-40

Summary of Nuclide Activity Sample ID : 30423 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 9-JUN-2014 20:34:56 Number of lines tentatively identified by NID 8

0 8

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 l.28E+09Y

1. 00 9.459E-06 9.459E-06 1.124E-06
11. 88 A

PB-212 10.64H

1. 00 4.973E-07 4.986E-07 0.946E-07
18. 96 A

BI-214 19.90M

1. 09 5.839E-07 6.355E-07
1. 112E-07 17.50 A

PB-214

26. SOM
1. 06 5.986E-07 6.374E-07 1.576E-07 24.73 A

AC-228 6.13H

1. 00 8.039E-07 8.077E-07 3.550E-07 43.95 KA Total Activity l.194E-05 l.204E-05 Grand Total Activity :

1.194E-05

1. 204E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30423 None Flags: "T" Tentatively associated Acquisition date Page :

3 9-JUN-2014 20:34:56

Interference Report Sample ID : 30423 No interference correction performed Acquisition date Page :

4 9-JUN-2014 20:34:56

Nuclide Line Activity Report Page :

5 Sample ID : 30423 Acquisition date 9-JUN-2014 20:34:56 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 71 10.67*

5.314E-01 9.459E-06 9.459E-06

11. 88 PB-212 74.81 10.50 l.685E+OO Line Not Found ------

77.11 19 17.70 1.777E+OO 4.529E-07 4.541E-07 57.07 87.19 ------

6.27 2.129E+OO Line Not Found ------

90.13 ------

1. 86 2.206E+OO Line Not Found ------

115. 12 0.59 2.535E+OO ------

Line Not Found ------

238.58 60 43.60*

2.082E+OO 4.973E-07 4.986E-07

18. 96 300.03 ------

3.34

1. 834E+OO Line Not Found ------

BI-214 76.86 19 0.58 1.777E+OO 1.382E-05 l.504E-05 57.07 79.29 ------

0.97

1. 869E+OO ------

Line Not Found ------

609.31 39 46.10*

1.084E+OO 5.839E-07 6.355E-07 17.50 665.44

1. 56 9.985E-01 Line Not Found ------

768.35 ------

4.88 8.685E-01 Line Not Found ------

806.16 ------

1. 23 8.283E-01 Line Not Found ------

934.04 3.16 7.177E-01 ------

Line Not Found ------

1120. 27 ------

15.00 6.114E-01 ------

Line Not Found ------

1155.18 ------

1. 69 5.973E-01 ------

Line Not Found ------

1238.11 ------

5.92 5.697E-01 ------

Line Not Found ------

1280.95 ------

1. 47 5.585E-01 ------

Line Not Found ------

1377.66 ------

4.02 5.401E-01 ------

Line Not Found ------

1385.30 ____..... _

0.78 5.391E-01 ------

Line Not Found ------

1401. 48

1. 39 5.370E-01 ------

Line Not Found ------

1407.97 2.48 5.362E-01 ------

Line Not Found ------

1509.22 ------

2.19 5.292E-01 ------

Line Not Found ------

1583.22 0.72 5.296E-01 ------

Line Not Found ------

1661. 26 1.15 5.351E-01 ------

Line Not Found ------

1729.58 ------

3.05 5.442E-01 ------

Line Not Found ------

1764.49 ------

15.90 5.503E-01 ------

Line Not Found ------

1847.41 ------

2.12 5.694E-01 ------

Line Not Found ------

PB-214 53.17 1.10 5.543E-01 ------

Line Not Found ------

74.81 ------

6.52 1.685E+OO ------

Line Not Found ------

77.11 19

11. 00 1.777E+OO 7.288E-07 7, 7 61E-07 57.07 87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 1.15 2.206E+OO Line Not Found ------

241. 92 7.46 2.067E+OO Line Not Found ------

258.94 0.55 1.994E+OO ------

Line Not Found ------

295.09 28 19.20*

l.852E+OO 5.986E-07 6.374E-07 24.73 351.87 35 37.10 l.662E+OO 4.213E-07 4.487E-07 24.40 785.83 ------

1. 09 8.495E-01 ------

Line Not Found ------

839.00 ------

0.59 7.964E-01 Line Not Found ------

AC-228

89. 96 3.40 2.201E+OO Line Not Found ------

93.35 5.60 2.279E+OO Line Not Found ------

99.55 ------

1. 30 2.389E+OO Line Not Found ------

105.36 ------

2.00 2.463E+OO Line Not Found ------

108.99 ------

0.67 2.496E+OO Line Not Found ------

129.03 2.90 2.562E+OO Line Not Found ------

153.89 ------

0.84

2. 4 96E+OO Line Not Found ------

209.39 ------

4.10 2.221E+OO Line Not Found ------

216.24 0.80 2.187E+OO Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30423 Acquisition date 9-JUN-2014 20:34:56 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error 270.26 3.80 1.948E+OO Line Not Found ------

328.07 3.50

1. 738E+OO Line Not Found ------

338.42 40 12.40 1.705E+OO 1.432E-06

1. 438E-06
21. 62 340.94 0.52 l.696E+OO Line Not Found ------

409.62 2.20 l.499E+OO Line Not Found ------

463.10 ------

4. 60 l.368E+OO Line Not Found ------

562.65 ------

1. 01 1.164E+OO Line Not Found ------

581.52 ------

3.00 1.131E+OO Line Not Found ------

72 6. 63 0.87 9.173E-01 Line Not Found ------

755.28 ------

1. 32 8.833E-01 ------

Line Not Found ------

772.28

1. 09 8.641E-01 ------

Line Not Found ------

782.12 0.59 8.534E-01 ------

Line Not Found ------

794.79 ------

4.60 8.400E-01 ------

Line Not Found ------

830.59 ------

0.63 8.043E-01 Line Not Found ------

835.60

1. 71 7.996E-01 ------

Line Not Found ------

840.44 0.94 7.951E-01 ------

Line Not Found ------

904.29 ------

0.89 7.403E-01 ------

Line Not Found ------

911.16 ------

29.00*

7.349E-01 Line Not Found ------

964. 64 5.80

6. 962E-01 Line Not Found ------

968. 97 13 17.40 6.929E-01 8.039E-07 8.077E-07 43.95 1246.60 ------

0.57 5.673E-01 ------

Line Not Found ------

1459.19 ------

1. 06 5.315E-01 ------

Line Not Found ------

1496. 00 ------

1. 05 5.296E-01 ------

Line Not Found ------

1501. 44 ------

0.58 5.294E-01 ------

Line Not Found ------

1580.30 ------

0. 71 5.295E-01 ------

Line Not Found ------

1588.23 ------

3.60 5.298E-01 ------

Line Not Found ------

1630.47

1. 95 5.324E-01 ------

Line Not Found ------

1638.10 ------

0.54 5.330E-01 ------

Line Not Found ------

Flag: "*" = Keyline

Minimum Detectable Activity Report Page :

7 Sample ID 30423 Acquisition date 9-JUN-2014 20:34:56 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

3.

477.61 5.8235E-07 MN-54

6.

834.83 1.3172E-07 MN-56

0.

846.81 2.6287E-08 C0-57

18.

122.06 7.6836E-08 C0-58

1.

810.79 6.7365E-08 C0-60

1.

1332.50 1.0085E-07 SB-124

1.

602.73 5.1680E-08 SB-125

3.

427.88

1. 94 71E-07 CS-134
0.

604. 71 4.0754E-08 CS-137

4.

661.66 1.0646E-07