U23 Ld North 11-10 - Health Physics Sample Records
ML20034E194
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 05/16/2016
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034E194 (10)


Text

Health Physics Sample Records Sample ID: 142506 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

14060614BD 06 NORTH LAYDOWN # 11

~mmon-1 Resp Org: P4000 - PROJECT MANAGEMEt Cross Ref Sample ID: Priority: N

Contact:

COOPER, TERRY L Survey No:

Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/09/14 08:44 Comments: COUNT TO MDA I Origin -I Mat. SizeNolume: 1979 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00

Description:

NORTH LAYDOWN #11 I Collectio-n I Sample Tech: DYNES, WILLIAM J Sample Date: 06/06/14 10:25 Count Time: 900 (secs.)

Tritium Req: No Sample SizeNolume: 1979 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA RLSS§j Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: 1'7' ll..ocationl Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:

Stored By:, Date: 00/00/00 00:00 Sample Loe:

Other: COUNT TO MDA Material Loe:

06/19/2014 09:07 Page 1 of 3

Health Physics Sample Records Sample ID: 142506 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

14060614BD 06 NORTH LAYDOWN # 11 Ana_!ysisJ Geometry _ _ _ _ MCAID Quant. Units Method FPIAP Lab Analysis By Date Mod ID Mod Date C_1L_marinelli_sand_ 30419 1979GR .000 NEESE, DAVID J 06109114 20:18 Isotope Mode Activity Activity Uncert. LLDIMDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 9.533E-6 1.112E-6 r 83.626% 40 0 TL-208 NT 3.351E-7 8.66E-8 r 2.940% 208 0 PB-212 NT 4.512E-7 1.015E-7 r 3.958% 212 0 PB-214 NT 5.505E-7 1.871 E-7 r 4.829% 214 0 AC-228 NT 5.297E-7 1.31E-7 r 4.647% 228 0 BE-7 AP 7.4794E-7 Iv 0.000% 7 0 MN-54 AP 9.9773E-8 li1 0.000% 54 0 MN-56 AP 9.5349E-8 w 0.000% 56 0 C0-57 AP 8.4073E-8 w 0.000% 57 0 C0-58 AP 7.4561E-8 w 0.000% 58 0 C0-60 AP 3.6173E-8 Iv 0.000% 60 0 SB-124 AP 1.8626E-8 li1 0.000% 124 0 SB-125 FP 2.0504E-7 Iv 0.000% 125 0 CS-134 FP 8.5147E-8 Iv' 0.000% 134 0 CS-137 FP 8.0139E-8 Iv 0.000% 137 Analysis Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/11/14 08:03 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:

Comments:

06/19/2014 09:07 Page 2 of 3

Health Physics Sample Records Sample ID: 142506 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r

Description:

14060614BD 06 NORTH LAYDOWN # 11 I Review/Approvej HP Eng Review Reviewed: COOPER, TERRY L Date: 06/11/14 08:03 Comments: the 345 keV peak is not associated with any plant-produced radionuclide Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:

_______ Final Approval Approved: COOPER, TERRY L Date: 06/11/14 08:03 Comments:

06/19/2014 09:07 Page 3 of 3

  • SONGS HEALTH PHYSICS REPORT 9-JUN-2014 20:11 *
  • >>>>> SAMPLE PARAMETERS<<<<< *
  • Title 14060614BD 06 NORTH LAYDOWN # 11 *
  • ID 30419 Acquisition date: 9-JUN-2014 20:08:35. *
  • Start Time: 9-JUN-2014 20:08:00. *
  • Stop Time: 9-JUN-2014 20:08:00. Counting System U2GSP *
  • Quantity l.97900E+03 GR IHPS Sample Number: 142506 *
  • Geometry C lL marinelli sand 1 Analysis Library HP NATURAL *
  • Operator: DAVID NEEBE *
  • >>>>> C #41-TP11750A PARAMETERS<<<<< *
  • Elapsed Live Time 0 00:03:00.42 Calibration 9-JUN-2014 19:38: *
  • Elapsed Real Time 0 00:03:00.47 Energy Offset -1.08890E-01 *
  • Deadtime 0.0% Energy Slope 4.99807E-01 *
  • Activity Mult Factor: 1.00000E+OO Energy Tolerance: 1. 00000 *
  • Half Life Ratio 8.00000 Sensitivity 5.00000
  • Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 238.75 53 22 1. 20 477.87 472 11 22.5 4.24E+OO PB-212 1 241. 82 17 4 1. 25 484.02 482 5 28.0 1.86E-01 PB-214 1 295.64 25 9 1. 98 591. 69 585 13 34.0 1.15E+OO PB-214 1 337.98 28 2 1. 73 67 6. 3 9 672 8 20.6 7.27E-01 AC-228 1 345.65 15 2 2.28 691.74 688 8 28.2 7.51E-01 1 351.86 48 0 1. 46 704.16 698 11 15.0 7.95E-01 PB-214 1 582.87 28 7 3.29 1166.26 1163 12 25.8 1.80E+OO TL-208 1 911. 15 15 0 1. 84 1822.85 1818 8 24.7 2.99E-01 AC-228 1 1460.83 75 0 1. 83 2922.06 2916 12 11. 7 5.58E-01 K-40

Summary of Nuclide Activity Page : 2 Sample ID : 30419 Acquisition date 9-JUN-2014 20:08:35 Total number of lines in spectrum 9 Number of unidentified lines 1 Number of lines tentatively identified by NID 8 88.89%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error %Error Flags K-40 l.28E+09Y 1. 00 9.533E-06 9.533E-06 1.112E-06 11. 67 A TL-208 3.05M 1. 58 2.121E-07 3.351E-07 0.866E-07 25.85 A PB-212 10.64H 1. 00 4.SOlE-07 4.512E-07 1. 015E*-07 22.49 A PB-214 26.80M 1. 06 5.215E-07 5.505E-07 1. 871E-07 33.99 A AC-228 6.13H 1. 00 5.276E-07 5.297E-07 l.310E-07 24.73 A Total Activity 1.124E-05 1.140E-05 Grand Total Activity: 1.124E-05 1.140E-05 Flags: "K" Keyline not found "M" Manually accepted "E" Manually edited "A" Nuclide specific abn. limit

Unidentified Energy Lines Page : 3 Sample ID : 30419 Acquisition date : 9-JUN-2014 20:08:35 It Energy Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err %Eff Flags 1 345.65 15 2 2.28 691.74 688 8 B.33E-02 28.2 1.70E+OO Flags: "T" = Tentatively associated

Interference Report Page : 4 Sample ID : 30419 Acquisition date 9-JUN-2014 20:08:35 No interference correction performed

Nuclide Line Activity Report Page : 5 Sample ID : 30419 Acquisition date 9-JUN-2014 20:08:35 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 75 10.67* 5.560E-01 9.533E-06 9.533E-06 11. 67 TL-208 72.80 ------ 2.14 1.486E+OO ------ Line Not Found ------

74.97 ------ 3.60 1.577E+OO ------ Line Not Found ------

84.79 ------ 1. 27 1.917E+OO ------ Line Not Found ------

252.45 ------ 0.80 2.004E+OO ------ Line Not Found ------

277.28 ------ 6.80 1.917E+OO ------ Line Not Found ------

510.61 ------ 21. 60 1.298E+OO ------ Line Not Found ------

583.02 28 86.00* 1.158E+OO 2.121E-07 3.351E-07 25.85 763.06 ---*--- 1. 64 8.934E-01 ------ Line Not Found ------

860.30 ------ 12.00 7.922E-01 ------ Line Not Found ------

PB-212 74.81 ------ 10.50 1.570E+OO ------ Line Not Found ------

77 .11 ------ 17.70 1.661E+OO ------ Line Not Found ------

87.19 ------ 6.27 1.983E+OO ------ Line Not Found ------

90.13 ------ 1. 86 2.055E+OO ------ Line Not Found ------

115. 12 0.59 2.376E+OO ------ Line Not Found ------

238.58 53 43.60* 2.055E+OO 4.501E-07 4.512E-07 22.49 300.03 ------ 3.34 1. 843E+OO ------ Line Not Found ------

PB-214 53.17 ------ 1.10 5.203E-01 ------ Line Not Found ------

74.81 ------ 6.52 1.570E+OO ------ Line Not Found ------

77 .11 ------ 11. 00 1.661E+OO ------ Line Not Found ------

87.19 ------ 3.88 1.983E+OO ------ Line Not Found ------

90.13 ------ 1.15 2.055E+OO ------ Line Not Found ------

241. 92 17 7.46 2.043E+OO 8.274E-07 8.734E-07 27.95 258.94 ------ 0.55 1.981E+OO ------ Line Not Found ------

295.09 25 19.20* 1.857E+OO 5.215E-07 5.505E-07 33.99 351.87 48 37.10 1.686E+OO 5.800E-07 6.123E-07 15.04 785.83 ------ 1. 09 8.674E-01 ------ Line Not Found ------

839.00 ------ 0.59 8.122E-01 ------ Line Not Found ------

AC-228 89. 96 ------ 3.40 2.051E+OO ------ Line Not Found ------

93.35 ------ 5.60 2.124E+OO ------ Line Not Found ------

99.55 ------ 1. 30 2.229E+OO ------ Line Not Found ------

105.36 ------ 2.00 2.301E+OO ------ Line Not Found ------

108.99 ------ 0. 67 2.335E+OO ------ Line Not Found ------

129.03 ------ 2.90 2.414E+OO ------ Line Not Found ------

153.89 ------ 0.84 2.377E+OO ------ Line Not Found ------

209.39 ------ 4.10 2.168E+OO ------ Line Not Found ------

216.24 ------ 0.80 2.141E+OO ------ Line Not Found ------

270.26 ------ 3.80 1.941E+OO ------ Line Not Found ------

328.07 ------ 3.50 1.756E+OO ------ Line Not Found ------

338.42 28 12.40 1.726E+OO 1.002E-06 1.006E-06 20.58 340.94 ------ 0.52 1.718E+OO ------ Line Not Found ------

409.62 ------ 2.20 l.531E+OO ------ Line Not Found ------

463.10 ------ 4.60 1.401E+OO ------ Line Not Found ------

562.65 ------ 1. 01 1.195E+OO ------ Line Not Found ------

581.52 ------ 3.00 1.160E+OO ------ Line Not Found ------

72 6. 63 ------ 0.87 9.382E-01 ------ Line Not Found ------

755.28 ------ 1. 32 9.027E-01 ------ Line Not Found ------

772. 28 ------ 1. 09 8.827E-01 ------ Line Not Found ------

782.12 ------ 0.59 8. 716E-01 ------ Line Not Found ------

Nuclide Line Activity Report (continued) Page : 6 Sample ID : 30419 Acquisition date 9-JUN-2014 20:08:35 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error 794.79 ------ 4.60 8.576E-01 ------ Line Not Found ------

830.59 ------ 0.63 8.205E-01 ------ Line Not Found ------

835.60 ------ 1. 71 8.155E-01 Line Not Found ------

840.44 ------ 0.94 8.108E-01 ------ Line Not Found ------

904.29 ------ 0.89 7.542E-01 ------ Line Not Found ------

911.16 15 29.00* 7.487E-01 5.276E-07 5.297E-07 24.73 964. 64 ------ 5.80 7.091E-01 ------ Line Not Found ------

968.97 ------ 17.40 7.061E-01 ------ Line Not Found ------

1246.60 ------ 0.57 5.825E-01 ------ Line Not Found ------

1459.19 ------ 1. 06 5.560E-01 ------ Line Not Found ------

1496.00 ------ 1. 05 5.563E-01 ------ Line Not Found ------

1501. 44 ------ 0.58 5.565E-01 ------ Line Not Found ------

1580.30 ------ 0. 71 5.624E-01 Line Not Found ------

1588.23 ------ 3.60 5.634E-Ol Line Not Found ------

1630.47 ------ 1. 95 5.696E-01 Line Not Found ------

1638.10 ------ 0.54 5.709E-01 ------ Line Not Found ------

Flag: "*" = Keyline

Minimum Detectable Activity Report Page : 7 Sample ID 30419 Acquisition date 9-JUN-2014 20:08:35 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)

BE-7 6. 477.61 7.4794E-07 MN-54 3. 834.83 9.9773E-08 MN-56 2. 846.81 9.5349E-08 C0-*57 19. 122.06 8.4073E-08 C0-58 1. 810.79 7.4561E-08 C0-60 0. 1332.50 3.6173E-08 SB-124 0. 602.73 1.8626E-08 SB-125 4. 427.88 2.0504E-07 CS-134 4. 604.71 8.5147E-08 CS-137 2. 661.66 8.0139E-08