ML20034E030
Text
Health Physics Sample Records Sample ID: 142499 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140605BD10 SOUTH LAY DOWN# 20
!Common!
Resp Org: P4000 - PROJECT MANAGEMEr Cross Ref Sample ID: Priority: N
Contact:
COOPER, TERRY L Survey No:
Reference ID: Accounting Subcode: Unknown Mat: NO Hazardous Mat: NO Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Date: 06/06/1410:11 Comments:
Origin Mat. SizeNolume: 2042 GRAMS Docmnt/MO/Act #: Proposed Ship Date: 00/00/00 00:00
Description:
SOUTH LAY DOWN # 20 I Collectic,n]
Sample Tech: DYNES, WILLIAM J Sample Date: 06/05/14 08:40 Count Time: 900 (secs.)
Tritium Req: No Sample SizeNolume: 2042 GRAMS Instructions: COUNT TO MDA Comments: COUNT TO MDA I_.RL5_SSJ Exempt: No Evaluated: No Chem Notification: No State Permit: No Offsite Analysis: No Effluent Permit: No Container Surveyed: No Cleared For Release: Yes Container Evaluated: Yes Form 212 Ready: 1,7' ILocation I Unit: NON-UNIT RE Area: MS Elev: 100 Room: Depth: (in.) Equip ID:
Stored By:, Date: 00/00/00 00:00 Sample Loe:
Other: COUNT TO MDA Material Loe:
06/19/2014 10:17 Page 1 of 3
Health Physics Sample Records Sample ID: 142499 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
140605BD10 SOUTH LAY DOWN# 20 jAnalysis I Geometry MCAID Quant. Units Method FP/AP Lab Analysis By Date Mod ID Mod Date A_1L_marinelli_sand- 30388 2042GR .000 NEESE, DAVID J 06/06/14 20:58 Isotope Mode Activity Activity Uncert. LLDIMDA %Abund. Atom. No. Comments Mod Id Mod Date 0 K-40 NT 8.395E-6 1.043E-6 r 80.168% 40 0 PB-212 NT 4.532E-7 1.049E-7 r 4.328% 212 0 Bl-214 NT 5.209E-7 1.159E-7 r 4.974% 214 0 PB-214 NT 6.633E-7 1.331E-7 r 6.334% 214 0 AC-228 NT 4.394E-7 1.584E-7 r 4.196% 228 0 BE-7 AP 7.5026E-7 )v 0.000% 7 0 MN-54 AP 8.5066E-8 )v 0.000% 54 0 MN-56 AP 6.9817E-8 )v 0.000% 56 0 C0-57 AP 5.376E-8 w 0.000% 57 0 C0-58 AP 1.0546E-7 Iv 0.000% 58 0 C0-60 AP 1.2433E-7 Iv 0.000% 60 0 SB-124 AP 4.7724E-8 )v 0.000% 124 0 SB-125 FP 1.8672E-7 )v 0.000% 125 0 CS-134 FP 6.3888E-8 Iv 0.000% 134 0 CS-137 FP 7.9567E-8 )v 0.000% 137 I An~l_y~is Review Re-Analize: No Lie Rad Mat Present: No Reviewed: COOPER, TERRY L Date: 06/11/14 07:18 Hp Eng Rvw Reqd: Yes Rad Mat Present: Yes HP Notified Name:
Comments:
06/19/2014 10:17 Page 2 of 3
Health Physics Sample Records Sample ID: 142499 Type: RLSSS Type Detail: SAND Status: APPROVED Rasterized: r
Description:
1406058010 SOUTH LAY DOWN# 20 I Review/Ape!:ove I HP Eng Review Reviewed: COOPER, TERRY L Date: 06/11/14 07:18 Comments:
Disposition Disposition: OTHER Result: Sample contains only natural isotopes Remarks:
Final Approval Approved: COOPER, TERRY L Date: 06/11/14 07:18 Comments:
06/19/201410:17 Page 3 of 3
L]roTs'oN
,c,ti,i:,,,. ,~,..,, ...,,,.,,..,i l....,:"">
SONGS RADIOLOGICAL SURVEY £)E5isoN
- "'"""*'"n"'*""" ,..,,_,
DATE 05 / 27 /20141 TIME 1210 Page of UNIT N SURVEY REASON D Post-Decon D Pre-Job SURVEY NO.I"'-... SMEARS MASSLINNS AREA YD D Routine_ __ D Shipment/Receipt MO NO. I -...... 11.T Hot ELEV NIA D Job Coverage D Source/Leak Test REP NO. I ~"a....._ NO. 13-y a NO.I 13-y I a Gross Part.
NO.I dpm INili.l ROOM NIA D Pwr Entry_
MESA- SOUTHSIDE
% IX] Other Confirmatory surveys STAR YARD Crosshatch Area EQUIP. ID.
f+/-+/-\
vDenotes sample location 1
2 3
16 17 18 A
B C
N=33.37819 "'- ~~ \ ----------- 4 19 D W=l17.55323 ~ - ~ ~ 1
\ /
5 ~201 I IE
~~~
6 ~ I IF
~ ~~~:dt~i ~
7 22 I NIA 8 23 I ".
---~ --- l
\_I @ \V (;\ 0 010-n \~)f
( I \
\ \
9 10 24 I 251 I"'
I ~
r:_
i@K- I --'-(6'i:..!- f4\
V (i\
- \
\
\ ,
\ \
11 ~
\ i'C\
l'(!_)
16\1
'\:YI ---~I""\ \\ \\ I 12 ~
"~
i N=33.37782 \ 13 I ~-**'@ I W=I17.55319 \N=~3.37745 \ \ 14
@l e \ \. \
i . 20 9I W=1\'-7.55285 \ \
1 I
ti I
N=33.37759 I
\
\
\
l
\
\ \
\ \
\
15 SURVEY CLASS D Boundary D Trend Pt.
[xi General Area D Component D Individual N=33.3777t // W=117.55349 W=ll7.553f9 l SURVEY DESCRIPTION: Mesa Confrrmatory Surveys I l l
-1 \ \
G 2 L~ ', 1 \
i\
~
1 REMARKS: 100% Gamma Scan walkover peifonned 1 - ik \
- ~ /J ~
\1\ i.
in survey area and static readings taken at survey
\
\\
l
\ \
.P_Oints 1-20. No activity above background detected.
BKG.=8000 cpm l i
... \ \
/ Construction Way \
\ \ '\
ti l ', \ Instruments used I.
~
\ l
\ l Model IASPl-SPl\3 I --r IASPl-SP,1\..3 l
l I \ \
\ \
Serial No.I 1876 TECHNICIAN 1869
~ SURVEYTYPE I
.' - - - - Denotes survey area \\\ \1 PrintM.CrumeslJ.Papson/S.Crum e D Shutdown (S/D)
I' \
N=N orthing GPS rea ~
N O y ard/StormfI drains present . g \
\ Sign I [Reference Number 1---x I'
r
- -------------x..._____---------x W=Westing GPS rea~g
.;\
\
-;,t.. Print APPROVED BY S0123-Vll-20.9 Form Number I*' 1 1 Sign j [ scE HP (213) 1259-1000 I \
II '
Approval Date: Time: REV. 3 09/07
- SONGS HEALTH PHYSICS REPORT 6-JUN-2014 20:49 *
- >>>>> SAMPLE PARAMETERS<<<<<
- Title 140605BD10 SOUTH LAY DOWN# 20
- ID 30388 Acquisition date: 6-JUN-2014 20:46:47. *
- Start Time: 6-JUN-2014 20:46:00.
- Stop Time: 6-JUN-2014 20:46:00.
Counting System U2GSP *
- Quantity 2.04200E+03 GR IHPS Sample Number: 142499
- Geometry A 11 marinelli_sand_l Analysis Library HP NATURAL *
- Operator: DAVID NEEBE
- >>>>> A #41-TP11679B PARAMETERS<<<<< *
- Elapsed Live Time 0 00:03:00.44 Calibration 6-JUN-2014 20:05:
- Elapsed Real Time 0 00:03:00.48 Energy Offset 2.54391E-01 *
- Deadtime 0.0% Energy Slope 4.99481E-01
- Activity Mult Factor: 1.00000E+OO
- Energy Tolerance: 1. 00000 *
- Half Life Ratio 8.00000 Sensitivity 5.00000
- Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1 77.38 20 44 1. 32 154.41 152 7 58.7 4.83E+OO BI-214 PB-212 PB-214 1 238.34 56 23 1. 33 4 7 6. 67 470 12 23.2 3.64E+OO PB-212 1 295.20 30 2 1. 28 590.50 586 8 20.1 7.28E-01 PB-214 1 351. 7 5 37 7 1. 58 703.72 699 8 20.9 2.64E+OO PB-214 1 609.51 33 5 1. 68 1219.74 1215 11 22.2 9.08E-01 BI-214 1 911.22 13 4 1. 77 1823.76 1819 8 36.1 3.13E-01 AC-228 1 1460.88 65 0 1. 96 2924.13 2918 11 12.4 5.14E-01 K-40
Unidentified Energy Lines Page : 3 Sample ID : 30388 Acquisition date 6-JUN-2014 20:46:47 None Flags: "T" Tentatively associated
Interference Report Page : 4 Sample ID : 30388 Acquisition date 6-JUN-2014 20:46:47 No interference correction performed
Nuclide Line Activity Report Page : 5 Sample ID : 30388 Acquisition date 6-JUN-2014 20:46:47 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error K-40 1460.83 65 10.67* 5.314E-01 8.395E-06 8.395E-06 12.42 PB-212 74.81 ------ 10.50 1.685E+OO ------ Line Not Found ------
77 .11 20 17.70 1. 7 93E+OO 4.715E-07 4.726E-07 58.74 87.19 ------ 6.27 2.129E+OO ------ Line Not Found ------
90.13 ------ 1. 86 2.206E+OO ------ Line Not Found ------
115. 12 ------ 0.59 2.535E+OO ------ Line Not Found ------
238.58 56 43.60* 2.083E+OO 4.520E-07 4,532E-07 23.15 300.03 ------ 3.34 1.834E+OO ------ Line Not Found ------
BI-214 76.86 20 0.58 1.793E+OO l.439E-05 1.558E-05 58.74 79.29 ------ 0.97 l.869E+OO ------ Line Not Found ------
609.31 33 46.10* l.084E+OO 4.811E-07 5.209E-07 22.25 665.44 ------ 1. 56 9.985E-01 ------ Line Not Found ------
768.35 ------ 4.88 8.685E-01 ------ Line Not Found ------
806.16 ------ 1. 23 8.283E-01 ------ Line Not Found ------
934.04 ------ 3.16 7.177E-01 ------ Line Not Found ------
1120. 27 ------ 15.00 6 .114E-01 ------ Line Not Found ------
1155.18 ------ 1. 69 5.973E-01 ------ Line Not Found ------
1238 .11 ------ 5.92 5.697E-01 ------ Line Not Found ------
1280.95 ------ 1. 47 5.585E-01 ------ Line Not Found ------
1377.66 ------ 4.02 5.401E-01 ------ Line Not Found ------
1385. 30 ------ 0.78 5.391E-01 ------ Line Not Found ------
1401. 48 ------ 1. 39 5.370E-01 ------ Line Not Found ------
1407.97 ------ 2.48 5.362E-01 ------ Line Not Found ------
1509.22 ------ 2.19 5.292E-01 ------ Line Not Found ------
1583.22 ------ 0. 72 5.296E-01 ------ Line Not Found ------
1661. 26 ------ 1.15 5.351E-01 ------ Line Not Found ------
1729.58 ------ 3.05 5.442E-01 ------ Line Not Found ------
1764.49 ------ 15.90 5.503E-01 ------ Line Not Found ------
1847.41 ------ 2.12 5.694E-01 ------ Line Not Found ------
PB-214 53.17 ------ 1.10 5.543E-01 ------ Line Not Found ------
74.81 ------ 6.52 1. 685E+OO ------ Line Not Found ------
77 .11 20 11. 00 1. 793E+OO 7.586E-07 8.049E-07 58.74 87.19 ------ 3.88 2.129E+OO ------ Line Not Found ------
90.13 ------ 1.15 2.206E+OO ------ Line Not Found ------
241. 92 ------ 7.46 2.067E+OO ------ Line Not Found ------
258.94 ------ 0.55 1.994E+OO ------ Line Not Found ------
295.09 30 19.20* 1.852E+OO 6.252E-07 6.633E-07 20.07 351.87 37 37.10 1.662E+OO 4. 411E-07 4.680E-07 20.88 785.83 ------ 1. 09 8.495E-01 ------ Line Not Found ------
839.00 ------ 0.59 7.964E-01 ------ Line Not Found ------
AC-228 89. 96 ------ 3.40 2.201E+OO ------ Line Not Found ------
93.35 ------ 5.60 2.279E+OO ------ Line Not Found ------
99.55 ------ 1. 30 2.389E+OO ------ Line Not Found ------
105.36 ------ 2.00 2.463E+OO ------ Line Not Found ------
108.99 ------ 0. 67 2.496E+OO ------ Line Not Found ------
129.03 ------ 2.90 2.562E+OO ------ Line Not Found ------
153.89 ------ 0.84 2.496E+OO ------ Line Not Found ------
209.39 ------ 4.10 2.221E+OO ------ Line Not Found ------
216.24 ------ 0.80 2.187E+OO ------ Line Not Found ------
Nuclide Line Activity Report ( continued) Page : 6 Sample ID : 30388 Acquisition date 6-JUN-2014 20:46:47 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area %Abn %Eff uCi/GR uCi/GR %Error 270.26 ------ 3.80 1. 948E+OO Line Not Found -------
328.07 ------ 3.50 1. 738E+OO ------ Line Not Found ------
338.42 ------ 12.40 1. 704E+OO Line Not Found ------
340.94 ------ 0.52 1. 696E+OO Line Not Found ------
409.62 ------ 2.20 1. 499E+OO Line Not Found ------
463.10 ------ 4.60 1. 368E+OO Line Not Found ------
562.65 ------ 1. 01 1.164E+OO Line Not Found ------
581.52 ------ 3.00 1.131E+OO Line Not Found ------
726.63 ------ 0.87 9.173E-01 Line Not Found ------
755.28 ------ 1. 32 8.833E-01 Line Not Found ------
772. 28 ------ 1. 09 8.641E-01 Line Not Found ------
782.12 ------ 0.59 8.534E-01 Line Not Found ------
794.79 ------ 4.60 8.400E-01 Line Not Found ------
830.59 ------ 0.63 8.043E-Ol ------ Line Not Found ------
835.60 ------ 1. 71 7. 996E-01 ------ Line Not Found ------
840.44 ------ 0.94 7.951E-01 ------ Line Not Found ------
904.29 ------ 0.89 7.403E-01 Line Not Found ------
911.16 13 29.00* 7.349E-Ol 4.375E-07 4.394E-07 36.05 964. 64 ------ 5.80 6. 962E-01 Line Not Found ------
968. 97 ------ 17.40 6.933E-01 Line Not Found ------
1246.60 ------ 0.57 5.673E-01 Line Not Found ------
1459.19 ------ 1. 06 5.315E-01 Line Not Found ------
1496. 00 ------ 1. 05 5.296E-Ol Line Not Found ------
1501.44 ------ 0.58 5.294E-01 Line Not Found ------
1580.30 ------ 0.71 5.295E-01 Line Not Found ------
1588.23 ------ 3.60 5.298E-01 Line Not Found ------
1630.47 ------ 1. 95 5.324E-01 Line Not Found ------
1638.10 ------ 0.54 5.330E-01 Line Not Found ------
Flag: "*" = Keyline
Minimum Detectable Activity Report Page : 7 Sample ID 30388 Acquisition date 6-JUN-2014 20:46:47 Bckgnd Energy MDA Nuclide Sum (keV) (uCi/GR)
BE-7 6. 477.61 7.5026E-07 MN-54 2. 834.83 8.5066E-08 MN-56 1. 846.81 6.9817E-08 C0-57 8. ,122.06 5.3760E-08 C0-58 4. 810.79 l.0546E-07 C0-60 2. 1332.50 1.2433E-07 SB-124 1. 602.73 4. 7724E-08 SB-125 3. 427.88 1. 8672E-07 CS-134 2. 604.71 6.3888E-08 CS-137 2. 661.66 7.9567E-08