ML20034E016
Text
Sample ID:
142507 Type: RLSSS Type Detail: SAND
==
Description:==
14060614BD 07 NORTH LAYDOWN # 13
~ommonl Resp Org: P4000 - PROJECT MANAGEMEr
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments: COUNT TO MDA Origin Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/09/14 08:49 Mat. SizeNolume:
2175 GRAMS Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
NORTH LAYDOWN # 13 lf_ollecti~
Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA L_RLSSS Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
No ILocationJ Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Other: COUNT TO MDA Material Loe:
06/19/2014 09:07 Sample Date: 06/06/1411:30 Sample SizeNolume: 2175 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
~
Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Health Physics Sample Records Sample ID:
142507 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
14060614BD 07 NORTH LAYDOWN # 13
[t\\,~lysis Geometry__________ MCA ID Quant.
Units Method B_ 1 L_marinelli_sand_
30418 2175GR FP/AP
.000 Isotope Mode Activity_
Activity Uncert.
LLD/MDA
% Abund.
Atom. No.
0 K-40 0
TL-208 0
81-214 0
PB-214 0
BE-7 0
MN-54 0
MN-56 0
C0-57 0
C0-58 0
C0-60 0
SB-124 0
SB-125 0
CS-134 0
CS-137 NT 8.145E-6 1.287E-6 NT 3.084E-7 7.45E-8 NT 2.771E-7 7.09E-8 NT 6.582E-7 1.6E-7 AP 5.6094E-7 AP 1.1349E-7 AP 1.4311E-7 AP 8.4936E-8 AP 9.5608E-8 AP 1.1503E-7 AP 1.0542E-7 FP 2.5043E-7 FP 7.8264E-8 FP 1.0419E-7 I Analysis Review I Re-Analize:
No Hp Eng Rvw Reqd:
Yes Comments:
06/19/2014 09:07 r r r
Iv Iv Iv Iv Iv Iv Iv Iv Iv Iv 86.753%
3.285%
2.951%
7.011%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
Lie Rad Mat Present:
No Rad Mat Present:
Yes 40 208 214 214 7
54 56 57 58 60 124 125 134 137 Lab Analy~is By NEESE, DAVID J Comments Reviewed: COOPER, TERRY L HP Notified Name:
Rasterized: r Date Mod ID Mod Date 06/09/14 20:13 Mod Id Mod Date Date: 06/11/14 08:04 Page 2 of 3
Sample ID:
142507 Type: RLSSS Type Detail: SAND
==
Description:==
14060614BD 07 NORTH LAYDOWN # 13 I Review/Approve I Reviewed: COOPER, TERRY L Comments: the 338 keV peak is Ac-228 Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/2014 09:07 Health Physics Sample Records Status: APPROVED Rasterized:
HP Eng Review Date: 06/11/14 08:09 Disposition Result: Sample contains only natural isotopes Final Aoorova Date: 06/11/14 08:09 Page 3 of 3
SONGS HEALTH PHYSICS REPORT 9-JUN-2014 20:10
- Title
>>>>> SAMPLE PARAMETERS<<<<<
14060614BD 07 NORTH LAYDOWN # 13
- ID 30418 Acquisition date: 9-JUN-2014 20:07:46. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 9-JUN-2014 20:07:00.
9-JUN-2014 20:07:00.
Counting System 2.17500E+03 GR IHPS Sample Number:
B lL marinelli sand 1 Analysis Library Operator: DAVID NEEBE U2GSP 142507 HP NATURAL
>>>>> B #42-TP11663A PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.45 0 00:03:00.49 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 9-JUN-2014 19:36:
-5.05220E-01 5.00079E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1
77.04 23 34 1.10 155.07 150 8 49.4 2.06E+OO BI-214 PB-214 1
295.07 27 5
- 1. 24 591. 07 586 9 24.3 5.37E-01 PB-214 1
338.07 19 10
- 1. 52 677.04 672 13 41. 2 5.89E-01 1
351.91 41 0
2.17 704.73 698 12 16.2 8.53E-01 PB-214 1
583.14 22 0
- 1. 42 1167.12 1162 12 24.2 8.27E-01 TL-208 1
609.42 15 0
- 1. 50 1219.67 1215 8 25.6 4.05E-01 BI-214 1
1460.83 53 3
- 1. 75 2922.30 2915. 13 15.8 5.19E-01 K-40
Summary of Nuclide Activity Sample ID : 30418 Total number of lines in spectrum Number of unidentified lines Page :
2 Acquisition date 9-JUN-2014 20:07:46 Number of lines tentatively identified by NID 7
0 7
100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 l.28E+09Y
- 1. 00 8.145E-06 8.145E-06 1.287E-06 15.80 A
TL-208 3.05M
- 1. 65 l.873E-07 3.084E-07 0.745E-07 24.15 A
BI-214 19.90M
- 1. 08 2.561E-07
- 2. 771E-07 0.709E-07 25.58 A
PB-214 26.80M
- 1. 06 6.207E-07 6.582E-07 l.600E-07 24.31 A
Total Activity 9.209E-06 9.389E-06 Grand Total Activity :
9.209E-06 9.389E-06 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30418 Page :
3 Acquisition date : 9-JUN-2014 20:07:46 It 1
Energy 338.07 Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err
%Eff Flags 19 10
- 1. 52 677.04 672 13 1.03E-01 41.2 1.44E+OO T
Flags: "T" = Tentatively associated
Interference Report Sample ID : 30418 No interference correction performed Acquisition date Page :
4 9-JUN-2014 20:07:46
I Nuclide Line Activity Report Page :
5 Sample ID : 30418 Acquisition date 9-JUN-2014 20:07:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 53 10.67*
4, 211E-01 8.145E-06 8.145E-06 15.80 TL-208
- 72. 80 2.14 l.070E+OO Line Not Found ------
74.97 ------
3.60 1.156E+OO ------
Line Not Found ------
84.79 ------
- 1. 27 1.506E+OO ------
Line Not Found ------
252.45 ------
0.80 1.745E+OO ------
Line Not Found ------
277.28 ------
6.80 1.645E+OO ------
Line Not Found ------
510.61 ------
- 21. 60 1.035E+OO Line Not Found ------
583.02 22 86.00*
9.197E-01 1.873E-07 3.084E-07 24.15 763.06 ------
- 1. 64 7.126E-01 Line Not Found ------
860.30 ------
12.00 6.341E-01 Line Not Found ------
BI-214
- 76. 86 23 0.58
- 1. 236E+OO 2.191E-05 2.371E-05 49.41 79.29 ------
0.97
- 1. 320E+OO ------
Line Not Found ------
609.31 15 46.10*
8.831E-01 2.561E-07
- 2. 771E-07 25.58 665.44
- 1. 56 8.131E-01 ------
Line Not Found ------
768.35 ------
4.88 7.078E-01 Line Not Found ------
806.16 ------
- 1. 23 6.754E-01 Line Not Found ------
934.04 ------
3.16 5.861E-01 ------
Line Not Found ------
1120. 27 15.00 4.982E-01 Line Not Found ------
1155. 18
- 1. 69 4.860E-01 Line Not Found ------
1238.11 ------
5.92 4.615E-Ol Line Not Found ------
1280.95 ------
- 1. 4 7 4.510E-01 ------
Line Not Found ------
1377.66 ------
4.02 4.323E-01 ------
Line Not Found ------
1385.30 ------
0.78
- 4. 311E-01 ------
Line Not Found ------
1401.48 ------
- 1. 39 4.287E-01 ------
Line Not Found ------
1407.97 2.48 4.277E-01 ------
Line Not Found ------
1509.22 ------
2.19 4.165E-01 ------
Line Not Found ------
1583.22 ------
- 0. 72 4.120E-01 Line Not Found ------
1661.26 ------
1.15 4.103E-01 Line Not Found ------
1729.58 ------
3.05 4.114E-01 Line Not Found ------
1764.49 ------
15.90 4.128E-01 Line Not Found ------
1847.41 ------
2.12 4.187E-01 Line Not Found ------
PB-214 53.17 ------
1.10 2.929E-01 Line Not Found ------
74.81 6.52 1.150E+OO Line Not Found ------
77.11 23
- 11. 00 1.236E+OO 1.155E-06 1.225E-06 49.41 87.19 ------
3.88 1.579E+OO Line Not Found ------
90.13 1.15 1.662E+OO ------
Line Not Found ------
241. 92 7.46 1.790E+OO ------
Line Not Found ------
258.94 0.55
- 1. 718E+OO Line Not Found ------
295.09 27 19.20*
1.579E+OO 6.207E-07 6.582E-07 24.31 351.87 41 37.10 l.395E+OO 5.515E-07 5,848E-07 16.18 785.83 ------
- 1. 09 6.925E-01 ------
Line Not Found ------
839.00 ------
0.59 6.497E-01 ------
Line Not Found ------
Flag: "*"
Keyline
Minimum Detectable Activity Report Page :
6 Sample ID 30418 Acquisition date 9-JUN-2014 20:07:46 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 2.
477.61 5.6094E-07 MN-54
- 3.
834.83 1.1349E-07 MN-56
- 5.
846.81
- 1. 4311E-07 C0-57
- 18.
122.06 8.4936E-08 C0-58
- 2.
810.79 9.5608E-08 C0-60
- 1.
1332. 50 l.1503E-07 SB-124
- 5.
602.73 l.0542E-07 SB-125
- 5.
427.88 2.5043E-07 CS-134
- 2.
604.71 7.8264E-08 CS-137
- 3.
661.66 1.0419E-07