Health Physics Sample Records_~---------------------~
Sample ID:
142474 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140603BD 3 CULVERT 5 tc~°-'!l'!I~
Resp Org: P4000 - PROJECT MANAGEMEt
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:
1 origtn***1 Mat. SizeNolume:
1658 GRAMS
==
Description:==
CULVERT 5 I Collection]
Sample Tech: DYNES, WILLIAM J Tritium Req:
No Instructions:
Comments:
COUNT TO MDA IRLs?s I Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes l!,Qca_!:l9.!!
Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/05/14 07:06 Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/14 08:08 Sample SizeNolume: 1658 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
~
Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Other:
Material Loe:
06/19/2014 08:16 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Health Physics Sample Records Sample ID:
142474 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140603BD 3 CULVERT 5 LAnalysisl Geometry MCA ID Quant.
Units Method FP/AP A_ 1 L_marinelli_sand_
30372 1658GR
.000 Isotope Mode
.. Activity Activity Uncert.
LLD/MDA
%Abund.
0 K-40 0
TL-208 0
PB-212 0
Bl-214 0
PB-214 0
BE-7 0
MN-54 0
MN-56 0
C0-57 0
C0-58 0
C0-60 0
SB-124 0
SB-125 0
CS-134 0
CS-137 NT 0.00001367 1.49E-6 NT 2.193E-7 7.88E-8 NT 3.697E-7 8.23E-8 NT 5.234E-7 1.072E-7 NT 2.944E-7 1.556E-7 AP 4.7897E-7 AP 8.3025E-8 AP 1.4038E-7 AP 7.0589E-8 AP 1.1244E-7 AP 1.2135E-7 AP 7.8296E-8 FP 2.4951E-7 FP 4.6653E-8 FP 1.4004E-7 Analysis ~~iew.
Re-Analize:
No Hp Eng Rvw Reqd:
Yes Comments:
06/19/2014 08:16 r
90.669%
r 1.455%
r 2.452%
r 3.472%
r 1.953%
Iv 0.000%
~
0.000%
w 0.000%
Iv 0.000%
Iv 0.000%
Iv' 0.000%
Iv 0.000%
Iv 0.000%
lv7 0.000%
lv7 0.000%
Lie Rad Mat Present:
No Rad Mat Present:
Yes Atom. No.
40 208 212 214 214 7
54 56 57 58 60 124 125 134 137 Lab
---~alysis By PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:
Rasterized: r Date Mod ID Mod Date 06/05/1416:18 Mod Id Mod Date Date: 06/10/1414:33 Page 2 of 3
H_e_a_l_th_P_h~y_si_cs Sample Records ______________________ _
Sample ID:
142474 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140603BD 3 CULVERT 5 Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/10/1414:35 Comments: 218 keV peak is not from a plant-produced radionuclide Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/2014 08:16 Disposition Result: Sample contains only natural isotopes Final Aooroval Date: 06/10/1414:35 Rasterized: r Page 3 of 3
SONGS HEALTH PHYSICS REPORT 5-JUN-2014 16:15
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140603BD 3 CULVERT 5
- ID 30372 Acquisition date: 5-JUN-2014 16:12:48. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 5-JUN-2014 16:12:00.
5-JUN-2014 16:12:00.
Counting System l.65800E+03 GR IHPS Sample Number:
A lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142474 HP NATURAL
>>>>> A #41-TP11679B PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.43 0 00:03:00.46 0.0%
l.OOOOOE+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 5-JUN-2014 08:09:
2.12659E-01 4.99528E-01
- 1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1
76.09 47 21 5.20 151.90 145 12 24.0 4.64E+OO BI-214 1
218.08 14 6
- 1. 68 436.14 433 9 41. 9 7.07E-01 1
238.66 37 10
- 1. 21 477.35 473 8 22.3 1.04E+OO PB-212 1
294.99 11 9
- 1. 32 590.11 586 7 52.8 3.00E+OO PB-214 1
351. 86 24 4
- 1. 58 703. 96 700 8 24.8 8.23E-01 PB-214 1
583.07 14 5
2.04 1166.82 1161 9 35.9 6.34E-01 TL-208 1
609.24 27 0
- 1. 84 1219.21 1212 13 20.5 5.25E-01 BI-214 1
1460.92 86 0
- 1. 92 2924.20 2918 11 10.9 3.55E-01 K-40
Summary of Nuclide Activity Sample ID : 30372 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :
2 5-JUN-2014 16:12:48 Number of lines tentatively identified by NID 8
1 7
87.50%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 l.28E+09Y
- 1. 00 1.367E-05 1.367E-05 0.149E-05 10.87 A
TL-208 3.05M
- 1. 66 1.325E-07 2.193E-07 0.788E-07 35.93 A
PB-212 10.64H
- 1. 00 3.687E-07 3.697E-07 0.823E-07 22.26 A
BI-214 19.90M
- 1. 08 4.833E-07 5.234E-07 1.072E-07 20.49 A
PB-214 26.80M
- 1. 06 2.775E-07 2.944E-07
- 1. 556E-07 52.83 A
Total Activity
- 1. 4 94E-05 1.508E-05 Grand Total Activity :
1.494E-05 1.508E-05 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30372 Page :
3 Acquisition date : 5-JUN-2014 16:12:48 It 1
Energy 218.08 Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err
%Eff Flags 14 6
1.68 436.14 433 9 7.96E-02 41.9 2.18E+OO Flags: "T" = Tentatively associated
Interference Report Sample ID : 30372 No interference correction performed Acquisition date Page :
4 5-JUN-2014 16:12:48
Nuclide Line Activity Report Page :
5 Sample ID : 30372 Acquisition date 5-JUN-2014 16:12:48 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 86 10.67*
- 5. 314E-01 1.367E-05 l.367E-05 10.87 TL-208
- 72. 80 2.14
- 1. 594E+OO ------
Line Not Found ------
74.97 3.60 1.692E+OO Line Not Found 84.79 ------
- 1. 27 2.058E+OO Line Not Found ------
252.45 ------
0.80 2.021E+OO Line Not Found ------
277.28 6.80 l.920E+OO Line Not Found ------
510.61 ------
- 21. 60 l.265E+OO Line Not Found 583.02 14 86.00*
1.128E+OO l.325E-07 2.193E-07 35.93 763.06 ------
- 1. 64 8.744E-01 ------
Line Not Found ------
860.30 12.00 7.770E-01 ------
Line Not Found ------
PB-212 74.81 10.50 l.685E+OO Line Not Found ------
77.11 ------
17.70 1.782E+OO Line Not Found 87.19 ------
6.27 2.129E+OO Line Not Found ------
90.13
- 1. 86 2.206E+OO Line Not Found ------
115. 12 0.59 2.535E+OO Line Not Found ------
238.58 37 43.60*
2.082E+OO 3.687E-07 3.697E-07 22.26 300.03 ------
3.34 1.834E+OO Line Not Found ------
BI-214 7 6. 8 6 47 0.58
- 1. 740E+OO 4.207E-05 4.557E-05 23.98 7 9. 2 9 ------
0.97 1.869E+OO Line Not Found ------
609.31 27 46.10*
l.084E+OO 4.833E-07 5.234E-07 20.49 665.44
- 1. 56 9.985E-01 ------
Line Not Found ------
768.35 ------
4.88 8.685E-01 ------
Line Not Found ------
806.16 ------
- 1. 23 8.283E-01 ------
Line Not Found ------
934.04 3.16 7.177E-01 Line Not Found ------
1120.27 15.00 6.114E-01 Line Not Found ------
1155. 18
- 1. 69 5.973E-01 Line Not Found ------
1238.11 ------
5.92 5.697E-01 ------
Line Not Found ------
1280.95 ------
- 1. 47 5.585E-01 ------
Line Not Found ------
1377.66 ------
4.02 5.401E-01 ------
Line Not Found ------
1385.30 ------
0.78
- 5. 391E-01 ------
Line Not Found ------
1401.48 ------
- 1. 39 5.370E-01 ------
Line Not Found ------
1407.97 ------
2.48 5.362E-01 Line Not Found ------
1509.22 ------
2.19 5.292E-01 ------
Line Not Found ------
1583.22
- 0. 72 5.296E-01 Line Not Found ------
1661. 26 1.15 5.351E-01 Line Not Found ------
1729.58 ------
3.05 5.442E-01 ------
Line Not Found ------
1764.49 ------
15.90 5.503E-Ol ------
Line Not Found ------
1847.41 ------
2.12 5.694E-01 ------
Line Not Found ------
PB-214 53.17 1.10 5.543E-01 ------
Line Not Found ------
74.81 ------
6.52 1.685E+OO Line Not Found ------
77.11 ------
- 11. 00 1.782E+OO Line Not Found ------
87.19 ------
3.88 2.129E+OO Line Not Found ------
90.13 ------
1.15 2.206E+OO Line Not Found ------
241. 92 7.46 2.067E+OO Line Not Found ------
258.94 0.55 l.994E+OO Line Not Found ------
295.09 11 19.20*
1.853E+OO 2.775E-07 2.944E-07 52.83 351.87 24 37.10 1.662E+OO 3.449E-07 3.659E-07 24.77 785.83 ------
- 1. 09 8.495E-01 ------
Line Not Found ------
839.00 ------
0.59
- 7. 964E-01 Line Not Found ------
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 30372 Acquisition date 5-JUN-2014 16:12:48 Flag: "*"
Keyline
Minimum Detectable Activity Report Page :
7 Sample ID 30372 Acquisition date 5-JUN-2014 16:12:48 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 1.
477.61 4.7897E-07 MN-54
- 1.
834.83 8.3025E-08 MN-56
- 4.
846.81 l.4038E-07 C0-57
- 10.
122.06 7.0589E-08 C0-58
- 3.
810.79 1.1244E-07 C0-60
- 1.
1332.50 1.2135E-07 SB-124
- 2.
602.73 7.8296E-08 SB-125
- 4.
427.88 2.4951E-07 CS-134
- 0.
604.71 4.6653E-08 CS-137
- 5.
661.66 1.4004E-07