ML20034E004
Text
_________ Health Physics Sample Reco_rd~--- _____________________ _
Sample ID:
142473 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140603BD 2, CULVERT #3
[Commo_!l_J Resp Org: P4000 - PROJECT MANAGEMEt
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:
I _ Qr:igi_rij Mat. SizeNolume:
1642 GRAMS
==
Description:==
CULVERT 3
[co1iec1:io£!J Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA
[_g~~~sJ Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes
[hQ_C_c!tiOrJ Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/05/14 07:01 Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/14 07:57 Sample SizeNolume: 1642 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
~
Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Other:
Material Loe:
06/19/2014 08:05 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
___________ Health Physics Sample Records _________________________ _
Sample ID:
142473 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140603BD 2, CULVERT #3 I ~ 11~,y~!!i Geomet~ry~~~~--
C_1 L_marinelli_sand_
MCA ID Quant.
Units Method FP/AP 30377 1642GR
.000 Isotope Mode -~ctivity Activit¥ Uncert.
LLD/MDA
%Abund.
0 K-40 NT 0.00001757 1 _66E-6 0
PB-212 NT 4.7E-7 1-173E-7 0
Bl-214 NT 3.149E-7 7_37E-8 0
PB-214 NT 6.517E-7 1.796E~7 0
BE-7 AP 8.3663E-7 0
MN-56 AP 8.495E-8 0
C0-57 AP 7.9134E-8 0
C0-58 AP 8.0125E-8 0
C0-60 AP 4.3554E-8 0
SB-124 AP 8.2179E-8 0
SB-125 FP 2.3222E-7 0
CS-134 FP 9.3676E-8 0
[ Analysis RevieV'l_j Re-Analize:
No Hp Eng Rvw Reqd:
Yes Comments:
06/19/2014 08:05 r r r Iv Iv Iv Iv Iv Iv Iv Jv Iv 1,7 92.442%
2.473%
1.657%
3.429%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
Lie Rad Mat Present:
No Rad Mat Present:
Yes Atom. No.
40 212 214 214 7
54 56 57 58 60 124 125 134 137 Lab Analysis By_
PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:
Rasterized:
Date Mod ID Mod Date 06/05/1416:28 Mod Id Mod Date Date: 06/10/1414:26 Page 2 of 3
Sample ID:
142473 Type: RLSSS Type Detail: SAND
==
Description:==
140603BD 2, CULVERT #3 I Review/Approve I
~--
Reviewed: COOPER, TERRY L Comments:
Health Physics_ Sample Records Status: APPROVED HP Review Date: 06/10/14 14:26 D_isposition.::__ _________________________ _
Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/19/2014 08:05 Result: Sample contains only natural isotopes Final Approval Date: 06/10/1414:26 Rasterized: r Page 3 of 3
SONGS HEALTH PHYSICS REPORT 5-JUN-2014 16:25
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140603BD 2, CULVERT #3
- ID 30377 Acquisition date: 5-JUN-2014 16:22:28. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 5-JUN-2014 16:22:00.
5-JUN-2014 16:22:00.
Counting System 1.64200E+03 GR IHPS Sample Number:
C lL marinelli sand 1 Analysis Library Operator: MICHAEL PARK U2GSP 142473 HP NATURAL
>>>>> C #41-TP11750A PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.60 0 00:03:00.64 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 5-JUN-2014 08:14:
-l.39807E-01 4.99820E-01
- 1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1
238.82 46 14
- 1. 89 478.07 472 15 25.0 3.70E+OO PB-212 1
295.56 24 3
- 1. 85 591.59 587 13 27.6 1. OOE+OO PB-214 1
351.84 23 8
- 1. 50 704.17 699 12 33.5 1. 06E+OO PB-214 1
609.20 17 0
- 1. 88 1218.99 1215 8 23.4 4.43E-01 BI-214 1
1460.86 114 0
2.07 2922.26 2916 12 9.5 9.36E-01 I<:-4 0
Summary of Nuclide Activity Sample ID : 30377 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :
2 5-JUN-2014 16:22:28 Number of lines tentatively identified by NID 5
0 5
100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 1.28E+09Y
- 1. 00 1.757E-05 1.757E-05 0.166E-05 9, 4 6 A
PB-212 10.64H
- 1. 00 4.690E-07 4.700E-07 1.173E-07 24.95 A
BI-214 19.90M
- 1. 07 2.940E-07 3.149E-07 0.737E-07 23.42 A
PB-214
- 26. SOM
- 1. 05 6.192E-07 6,517E-07 l.796E-07 27.56 A
Total Activity 1.895E-05 l.901E-05 Grand Total Activity :
l.895E-05 1.901E-05 Flags: "K" Keyline not found "M"
Manually accepted "E" = Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30377 None Flags: "T" Tentatively associated Acquisition date Page :
3 5-JUN-2014 16:22:28
Interference Report Sample ID : 30377 No interference correction performed Acquisition date Page :
4 5-JUN-2014 16:22:28
Nuclide Line Activity Report Page :
5 Sample ID : 30377 Acquisition date 5-JUN-2014 16:22:28 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 114 10.67*
5.560E-01
- 1. 757E-05 1.757E-05 9.46 PB-212 74.81 ------
10.50
- 1. 570E+OO Line Not Found ------
77.11 ------
17.70 1.661E+OO Line Not Found ------
87.19 ------
6.27 1.983E+OO Line Not Found ------
90.13 ------
- 1. 86 2.055E+OO Line Not Found ------
115.12 0.59 2.376E+OO Line Not Found ------
238.58 46 43.60*
2.054E+OO 4.690E-07 4.700E-07 24.95 300.03 ------
3.34 1.843E+OO Line Not Found ------
BI-214 76.86 ------
0.58 1.651E+OO Line Not Found ------
79.29 ------
0.97 1.741E+OO Line Not Found ------
609.31 17 46.10*
1.112E+OO 2.940E-07 3.149E-07 23.42 665.44
- 1. 56 1.023E+OO Line Not Found ------
768.35 ------
4.88 8.873E-01 ------
Line Not Found ------
806.16 ------
- 1. 23 8.454E-01 ------
Line Not Found ------
934.04 3.16 7.310E-01 ------
Line Not Found ------
1120. 27 15.00 6.242E-01 ------
Line Not Found 1155.18
- 1. 69 6.105E-01 ------
Line Not Found ------
1238.11 ------
5.92 5.846E-01 Line Not Found ------
1280.95 ------
- 1. 47 5.747E-01 ------
Line Not Found ------
1377.66 ------
4.02 5.602E-01 ------
Line Not Found ------
1385. 30 0.78 5.595E-01 ------
Line Not Found ------
1401.48 ------
- 1. 39 5.583E-01 Line Not Found ------
1407.97 ------
2.48 5.578E-01 ------
Line Not Found ------
1509.22 ------
2.19 5.568E-01 ------
Line Not Found ------
1583.22 0.72 5.620E-01 ------
Line Not Found ------
1661. 26 ------
1.15 5.753E-01 ------
Line Not Found ------
1729.58 ------
3.05 5.918E-Ol ------
Line Not Found ------
1764.49 ------
15.90 6.023E-01 ------
Line Not Found ------
1847.41 ------
2.12 6.331E-01 ------
Line Not Found ------
PB-214 53.17 ------
1.10 5.203E-01 ------
Line Not Found ------
74.81 ------
6.52
- 1. 570E+OO Line Not Found ------
77.11 ------
- 11. 00 1.661E+OO Line Not Found ------
87.19 ------
3.88 1.983E+OO Line Not Found ------
90.13 ------
1.15 2.055E+OO Line Not Found ------
241. 92 7.46 2.043E+OO Line Not Found 258.94 0.55 1.981E+OO Line Not Found ------
295.09 24 19.20*
1.857E+OO 6.192E-07
- 6. 517E-07 27.56 351.87 23 37.10 1.686E+OO 3.399E-07 3.577E-07 33.48 785.83
- 1. 09 8.674E-01 ------
Line Not Found ------
839.00 ------
0.59 8.122E-01 ------
Line Not Found ------
Flag: "*"
Keyline
Minimum Detectable Activity Report Page :
6 Sample ID 30377 Acquisition date 5-JUN-2014 16:22:28 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 5.
477.61 8.3663E-07 MN-54
- 3.
834.83 1.1637E-07 MN-56
- 1.
846.81 8.4950E-08 C0-57
- 11.
122.06
- 7. 9134E--08 C0-58
- 1.
810.79 8.0125E-08 C0-60
- 0.
1332.50 4.3554E-08 SB-124
- 2.
602.73 8.2179E-08 SB-125
- 3.
427.88 2.3222E-07 CS-134
- 3.
604. 71 9.3676E-08 CS-137
- 2.
661. 66 9.6490E-08