Health Physics Sample Records Sample ID:

142472 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 1 CULVERT 1

!Comm_<>_!!]

. Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments:

Reviewed: DYNES, WILLIAM J Comments:

l.. 9!:l9i!l]

Mat. SizeNolume:

1821 GRAMS

==

Description:==

CULVERT 1 1co11ecti~

Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA

[__B_LSSS_j Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes l.,Q_cation~I Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/05/14 06:54 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/14 07:57 Sample SizeNolume: 1821 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

W" Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/19/2014 08:02 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of3

  • --------~-------------H_e_a.lth Physics Sample Records Sample ID:

142472 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 1 CULVERT 1

[_Analysis]

Method Geometry____ MCA ID Quant.

Units FP/AP A_ 1 L_marinelli_sand_

30378 1821 GR

_ooo Isotope _ Mode Activity Activity Uncert.

LLD/MDA

%Abund.

0 K-40 NT 0.0000153 1.65E-6 0

PB-212 NT 4.662E-7 9.63E-8 0

Bl-214 NT 3.461E-7 1_046E-7 0

PB-214 NT 3.499E-7 1.264E-7 0

AC-228 NT 6.786E-7 1.5E-7 0

BE-7 AP 7.8081E-7 0

MN-54 AP 1.0074E-7 0

MN-56 AP 1.1917E-7 0

C0-57 AP 7.8151E-8 0

C0-58 AP 4.7226E-8 0

C0-60 AP 1.3939E-7 0

SB-124 AP 5_6474E-8 0

SB-125 FP 2-3502E-7 0

CS-134 FP 7.1626E-8 0

CS-137 FP 1.2898E-7

[_~_!laly.5is Revi~

Re-Analize:

No Hp Eng Rvw Reqd:

Yes Comments:

06/19/2014 08:02 r r r r Iv" Iv" w w

Iv'"

Iv Iv" Iv'"

Iv'"

iv 89.261%

2.720%

2_019%

2.041%

3_959%

0.000%

0_000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0_000%

Lie Rad Mat Present:

No Rad Mat Present:

Yes Atom. No.

40 212 214 214 228 7

54 56 57 58 60 124 125 134 137 Lab Analysis By PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:

Rasterized: r Date Mod ID Mod Date 06/05/1416:43 Mod Id Mod Date Date: 06/10/1414:18 Page 2 of 3

Sample ID:

142472 Type: RLSSS Type Detail: SAND

==

Description:==

140603BD 1 CULVERT 1

[Revie'NjApprove~I


~

Reviewed: COOPER, TERRY L Comments:

Health Physics Sample Records Status: APPROVED HP Review Date: 06/10/1414:25 DJ~osi_ti_o_n _______________ _

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/19/2014 08:02 Result: Sample contains only natural isotopes Final Aooroval Date: 06/10/14 14:25 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 5-JUN-2014 16:34

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140603BD 1 CULVERT 1

  • ID 30378 Acquisition date: 5-JUN-2014 16:31:46. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 5-JUN-2014 16:31:00.

5-JUN-2014 16:31:00.

Counting System 1.82100E+03 GR IHPS Sample Number:

A 11 marinelli sand 1 Analysis Library Operator: MICHAEL PARK U2GSP 142472 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.48 0 00:03:00.51 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 08:09:

2.12659E-01 4.99528E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

238.65 51 18 1.14 477.33 472 9 20.7 8.16E-01 PB-212 1

351.94 25 14

1. 53 704.12 698 11 36.1 9.19E-01 PB-214 1

608.99 19 5

2.14 1218.70 1214 10 30.2 8.54E-01 BI-214 1

910.68 18 0

2.07 1822.66 1818 8 22.1 2.22E-01 AC-228 1

1460.69 106 6

1. 80 2923. 73 2917 12 10.8 1.14E+OO K-40

Summary of Nuclide Activity Sample ID : 30378 Total number of lines in spectrum Number of unidentified lines Page :

2 Acquisition date 5-JUN-2014 16:31:46 Number of lines tentatively identified by NID 5

0 5

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 l.28E+09Y

1. 00 1.530E-05 l.530E-05 0.165E-05 10.76 A

PB-212 10.64H

1. 00 4.650E-07 4.662E-07
0. 963E-07 20.66 A

BI-214 19.90M

1. 08 3.198E-07 3.461E-07 1.046E-07 30.21 A

PB-214

26. SOM
1. 06 3.298E-07 3.499E-07 1.264E-07 36.13 KA AC-228 6.13H
1. 00 6.756E-07 6.786E-07 l.SOOE-07 22.11 A

Total Activity 1.709E-05

1. 714E-05 Grand Total Activity :

l.709E-05

1. 714E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30378 None Flags: "T" Tentatively associated Page :

3 Acquisition date 5-JUN-2014 16:31:46

Interference Report Sample ID : 30378 No interference correction performed Acquisition date Page :

4 5-JUN-2014 16:31:46

Nuclide Line Activity Report Sample ID : 30378 Nuclide Type: natural Nuclide Energy Area K-40 1460.83 106 PB-212 74.81 ------

77.11 ------

87.19 ------

90.13 ------

115.12 238.58 51 300.03 BI-214 76.86 79.29 ------

609.31 19 665.44 768.35 ------

806.16 934.04 1120.27 ------

1155.18 1238.11 ------

1280.95 ------

1377.66 ------

1385.30 ------

1401.48 ------

1407.97 ------

1509.22 ------

1583.22 ------

1661. 26 ------

1729.58 ------

1764.49 ------

1847.41 ------

PB-214 53.17 ------

74.81 ------

77.11 ------

87.19 ------

90.13 ------

241. 92 258.94 295.09 ------

351. 87 25 785.83 839.00 ------

AC-228

89. 96 ------

93.35 ------

99.55 ------

105.36 ------

108.99 ------

129.03 153.89 ------

209.39 ------

216.24

%Abn 10.67*

10.50 17.70 6.27

1. 86 0.59 43.60*

3.34 0.58 0.97 46.10*

1. 56
4. 88
1. 23 3.16 15.00
1. 69 5.92
1. 4 7 4.02 0.78
1. 39 2.48 2.19
0. 72 1.15 3.05 15.90 2.12 1.10 6.52
11. 00 3.88 1.15 7.46 0.55 19.20*

37.10

1. 09 0.59 3.40 5.60
1. 30 2.00 0.67 2.90 0.84 4.10 0.80 Page :

5 Acquisition date 5-JUN-2014 16:31:46 Uncorrected Decay Corr 1-Sigma

%Eff uCi/GR uCi/GR

%Error 5.314E-01 l.530E-05 1.530E-05 10.76

1. 685E+OO Line Not Found ------
1. 782E+OO Line Not Found ------

2.129E+OO Line Not Found ------

2.206E+OO Line Not Found ------

2.535E+OO Line Not Found ------

2.082E+OO 4.650E-07 4.662E-07 20.66 l.834E+OO Line Not Found ------

1. 772E+OO Line Not Found ------

l.869E+OO Line Not Found ------

1.085E+OO 3.198E-07 3.461E-07 30.21 9.985E-01 ------

Line Not Found ------

8.685E-01 Line Not Found ------

8.283E-01 Line Not Found ------

7. l 77E-01 ------

Line Not Found ------

6.114E-Ol ------

Line Not Found ------

5.973E-01 ------

Line Not Found ------

5.697E-01 ------

Line Not Found ------

5.585E-01 ------

Line Not Found ------

5.401E-Ol ------

Line Not Found ------

5.391E-01 ------

Line Not Found ------

5.370E-01 ------

Line Not Found ------

5.362E-01 ------

Line Not Found ------

5.292E-01 ------

Line Not Found ------

5. 296E-01 ------

Line Not Found ------

5.351E-01 ------

Line Not Found ------

5.442E-01 ------

Line Not Found ------

5.503E-01 ------

Line Not Found ------

5.694E-01 ------

Line Not Found ------

5.543E-01 ------

Line Not Found ------

1.685E+OO ------

Line Not Found ------

1. 782E+OO Line Not Found ------

2.129E+OO Line Not Found ------

2.206E+OO Line Not Found ------

2.067E+OO Line Not Found ------

l.994E+OO Line Not Found ------

l.852E+OO Line Not Found 1.662E+OO 3.298E-07 3.499E-07 36.13 8.495E-01 Line Not Found ------

7. 964E-01 Line Not Found ------

2.201E+OO Line Not Found ------

2.279E+OO Line Not Found ------

2.389E+OO Line Not Found ------

2.463E+OO Line Not Found ------

2.496E+OO Line Not Found ------

2.562E+OO Line Not Found ------

2. 4 96E+OO Line Not Found ------

2.221E+OO Line Not Found ------

2.187E+OO Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30378 Acquisition date 5-JUN-2014 16:31:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error 270.26 ------

3.80 1.948E+OO Line Not Found ------

328.07 3.50 1.738E+OO ------

Line Not Found ------

338.42 ------

12.40 1.704E+OO Line Not Found ------

340.94 0.52

1. 696E+OO Line Not Found ------

409.62 2.20 l.499E+OO ------

Line Not Found 463.10 ------

4. 60 l.368E+OO Line Not Found ------

562.65 ------

1. 01 1.164E+OO Line Not Found ------

581. 52

Loo 1.131E+OO Line Not Found ------

72 6. 63 ------

0.87 9.173E-01 ------

Line Not Found ------

755.28

1. 32 8.833E-01 Line Not Found ------

772. 28

1. 09 8.641E-01 ------

Line Not Found ------

782.12 0.59 8.534E-01 ------

Line Not Found ------

794.79 ------

4.60 8.400E-01 ------

Line Not Found ------

830.59 ------

0.63 8.043E-01 ------

Line Not Found ------

835.60

1. 71 7.996E-01 ------

Line Not Found ------

840.44 0.94 7.951E-01 ------

Line Not Found ------

904.29 0.89 7.403E-Ol ------

Line Not Found ------

911.16 18 29.00*

7.353E-01 6.756E-07 6.786E-07 22.11 964.64 ------

5.80 6.962E-01 ------

Line Not Found ------

968.97 17.40 6.933E-01 Line Not Found ------

1246.60 0.57 5.673E-01 Line Not Found ------

1459.19 ------

1. 06 5.315E-01 Line Not Found ------

1496.00 ------

1. 05 5.296E-01 Line Not Found ------

1501. 44 0.58 5.294E-01 ------

Line Not Found ------

1580.30 ------

0. 71 5.295E-01 Line Not Found ------

1588.23 ------

3.60 5.298E-Ol Line Not Found ------

1630.47

1. 95 5.324E-01 Line Not Found ------

1638.10 ------

0.54 5.330E-01 Line Not Found ------

Flag: "*" = Keyline

\\

Minimum Detectable Activity Report Page :

7 Sample ID 30378 Acquisition date 5-JUN-2014 16:31:46 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

5.

477.61 7.8081E-07 MN-54

2.

834.83 1.0074E-07 MN-56

3.

846.81 l.1917E-07 C0-57

15.

122.06 7.8151E-08 C0-58

0.

810.79

4. 7226E*-08 C0-60
2.

1332.50 l.3939E-07 SB-124

1.

602.73 5.6474E-08 SB-125

4.

427.88 2.3502E-07 CS-134

2.

604. 71 7.1626E-08 CS-137

5.

661. 66