ML20034D977

From kanterella
Jump to navigation Jump to search
Sy C-HATCH 12-20 - Health Physics Sample Records
ML20034D977
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 06/18/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034D977 (10)


Text

Sample ID:

142442 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 12 STAR 12-20 Dirt Sample Common Resp Org: P4000 - PROJECT MANAGEMEf

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

1arig1nl Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 05/30/14 08:07 Mat. SizeNolume:

1589 GRAMS Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00

==

Description:==

STAR 12 SOIL SAMPLE I Collection Sample Tech: DYNES, WILLIAM J Tritium Req:

No Instructions:

Comments:

COUNT TO MDA

[Kt,_sss l Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes l.b.Q_cation Unit: NON-UNIT RE Stored By:,

Sample Loe:

Other:

Material Loe:

06/18/2014 12:13 Area: MS Sample Date: 05/29/14 07:17 Sample SizeNolume: 1589 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Elev: 100 Room:

Depth: 3" (in.)

Equip ID:

Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Sample ID:

142442 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 12 STAR 12-20 Dirt Sample jAnalysisl Geometry MCAID Quant.

Units B_ 1 L_marinelli_sand_

30279 1589GR Isotope Mode Activity Activity Uncert.

0 K-40 NT 0.000010951.51E-6 0

TL-208 NT 4.293E-7 9.79E-8 0

PB-212 NT 5.279E-7 1.277E-7 0

Bl-214 NT 6.829E-7 1.45E-7 0

PB-214 NT 6.208E-7 2.207E-7 0

AC-228 NT 8.766E-7 2.176E-7 0

BE-7 AP 7.6781E-7 0

MN-54 AP 3.9031E-8 0

MN-56 AP 1.0994E-7 0

C0-57 AP 8.2734E-8 0

C0-58 AP 1.9876E-7 0

C0-60 AP 5.7877E-8 0

SB-124 AP 2.9197E-8 0

SB-125 FP 2.4783E-7 0

CS-134 FP 7.0915E-8 0

CS-137 FP 1.4556E-7 Analysis Review I Health Physics Sample Records Status: APPROVED Method FP/AP Lab Analysis By

.000 HENDERSON, JOE C LLD/MDA

%Abund.

Atom. No.

Comments r

77.728%

40 r

3.047%

208 r

3.747%

212 r

4.848%

214 r

4.407%

214 r

6.223%

228 w

0.000%

7 Iv' 0.000%

54 rvr 0.000%

56

!if" 0.000%

57 rvr 0.000%

58

!if" 0.000%

60 0.000%

124 w

0.000%

125 w

0.000%

134 w

0.000%

137 Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Comments:

06/18/2014 12:13 Rad Mat Present:

Yes Rasterized: r Date Mod ID Mod Date 05/30/14 12:48 Mod Id Mod Date Date: 06/10/14 09:58 Page 2 of 3

Sample ID:

142442 Type: RLSSS Type Detail: SAND

==

Description:==

140528BD 12 STAR 12-20 Dirt Sample r Review/Approve-l Reviewed: COOPER, TERRY L Comments:

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/2014 12:13 Health Physics Sample Records Status: APPROVED Rasterized: r HP Review Date: 06/10/14 09:58 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/14 09:58 Page 3 of 3

SONGS HEALTH PHYSICS REPORT 30-MAY-2014 12:46

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

110528BD 12 STAR 12-20 DIRT SAMPLE

  • ID 30279 Acquisition date: 30-MAY-2014 12:43:46 *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 30-MAY-2014 12:43:00 30-MAY-2014 12:43:00
1. 58900E+03 GR B lL marinelli sand 1 Operator: JOE Counting System IHPS Sample Number:

Analysis Library HENDERSON U2GSP 142442 HP NATURAL

>>>>> B #42-TP11663A PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.45 0 00:03:00.48 0.0%

l.OOOOOE+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 29-MAY-2014 21:44

-l.81343E-02 4.99764E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

238.65 44 22

1. 39 477.58 473 10 24.2 3.55E+OO PB-212 1

241.78 16 1

1. 20 483.83 482 6 26.9 4. llE-01 PB-214 1

295.54 19 8

2.12 591. 41 585 10 35.6 5.33E-01 PB-214 1

351.98 35 6

1. 7 9 704.34 699 12 23.0 1.03E+OO PB-214 1

583.08 22 0

1. 87 1166. 76 1160 11 22.8 1.07E+OO TL-208 1

609.08 27 3

2.66 1218.79 1214 11 21. 2 7.79E-01 BI-214 1

911. 08 16 0

1. 80 1823.12 1817 10 24.8 4.48E-01 AC-228 1

1460.64 52 0

2.51 2922.84 2916 12 13.8 1. 4 7E+OO K-40

Surrnnary of Nuclide Activity Sample ID : 30279 Total number ot' lines in spectrum Number of unidentified lines Page :

2 Acquisition date 30-MAY-2014 12:43:46 Number of lines tentatively identified by NID 8

0 8

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00 l.095E-05
1. 095E-05 0.151E-05
13. 81 A

TL-208 3.05M

1. 64 2.612E-07 4.293E-07 0.979E-07 22.81 A

PB-212 10.64H

1. 00 5.266E-07 5.279E-07 1.277E-07 24.18 A

BI-214 19.90M

1. 08 6.312E-07 6.829E-07 l.450E-07
21. 24 A

PB-214

26. SOM
1. 06 5.855E-07 6.208E-07 2.207E-07 35.56 A

AC-228 6.13H

1. 00 8.728E-07 8.766E-07 2.176E-07 24.82 A

Total Activity

1. 383E-05
1. 409E-05 Grand Total Activity :
1. 383E-05 1.409E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30279 None Flags: "T" Tentatively associated Acquisition date Page :

3 30-MAY-2014 12:43:46

Interference Report Sample ID : 30279 No interference correction performed Acquisition date Page :

4 30-MAY-2014 12:43:46

Nuclide Line Activity Report Sample ID : 30279 Nuclide Type: natural Nuclide Energy Area K-40 1460.83 52 TL-208

72. 80 74.97 84.79 ------

252.45 277.28 ------

510.61 ------

583.02 22 763.06 ------

860.30 PB-212 74.81 ------

77.11 ------

87.19 ------

90.13 ------

115.12 ------

238.58 44 300.03 ------

BI-214 76.86 ------

79.29 ------

609.31 27 665.44 ------

768.35 ------

806.16 ------

934.04 1120. 27 1155.18 ------

1238. 11 ------

1280.95 ------

1377.66 ------

1385. 30 1401. 48 1407.97 1509.22 ------

1583.22 ------

1661. 26 1729.58 ------

1764.49 ------

1847.41 ------

PB-214 53.17 74.81 ------

77.11 ------

87.19 ------

90.13 ------

241. 92 16 258.94 ------

295.09 19 351.87 35 785.83 ------

839.00

%Abn 10.67*

2.14 3.60

1. 27 0.80 6.80
21. 60 86.00*
1. 64 12.00 10.50 17.70 6.27
1. 86 0.59 43.60*

3.34 0.58 0.97 46.10*

1. 56 4.88
1. 23 3.16 15.00
1. 69 5.92
1. 47 4.02 0.78
1. 39 2.48 2.19
0. 72 1.15 3.05 15.90 2.12 1.10 6.52
11. 00 3.88 1.15 7.46 0.55 19.20*

37.10

1. 09 0.59 Page :

5 Acquisition date 30-MAY-2014 12:43:46 Uncorrected Decay Corr 1-Sigma

%Eff uCi/GR uCi/GR

%Error 4.212E-01 l.095E-05 1.095E-05 13.81 1.070E+OO ------

Line Not Found ------

1.156E+OO ------

Line Not Found ------

1.506E+OO ------

Line Not Found ------

1.745E+OO Line Not Found ------

1.645E+OO ------

Line Not Found ------

1.035E+OO ------

Line Not Found ------

9.198E-01 2.612E-07 4.293E-07 22.81 7.126E-01 ------

Line Not Found ------

6.341E-01 ------

Line Not Found ------

1.150E+OO ------

Line Not Found ------

1.239E+OO ------

Line Not Found ------

1.579E+OO Line Not Found ------

1.662E+OO ------

Line Not Found ------

2.085E+OO Line Not Found ------

1.804E+OO 5.266E-07 5.279E-07 24.18 1.562E+OO ------

Line Not Found ------

1.229E+OO ------

Line Not Found ------

1.320E+OO ------

Line Not Found ------

8.836E-01 6.312E-07 6.829E-07

21. 24 8.131E-01 ------

Line Not Found ------

7.078E-01 Line Not Found ------

6.754E-01 Line Not Found ------

5.861E-01 ------

Line Not Found ------

4.982E-01 Line Not Found ------

4.860E-01 ------

Line Not Found ------

4.615E-01 ------

Line Not Found ------

4.510E-01 ------

Line Not Found ------

4.323E-01 ------

Line Not Found ------

4. 311E-01 ------

Line Not Found ------

4.287E-01 Line Not Found ------

4.277E-01 Line Not Found ------

4.165E-01 Line Not Found ------

4.120E-01 Line Not Found ------

4.103E-01 Line Not Found ------

4.114E-01 Line Not Found ------

4.128E-01 Line Not Found ------

4.187E-01 ------

Line Not Found ------

2.929E-01 ------

Line Not Found ------

1.150E+OO ------

Line Not Found ------

1.239E+OO ------

Line Not Found ------

1.579E+OO Line Not Found ------

1.662E+OO ------

Line Not Found ------

1. 791E+OO 1.123E-06 1.190E-06 26.85 1.718E+OO Line Not Found ------

1.578E+OO 5.855E-07 6.208E-07 35.56 1.395E+OO 6.397E-07 6.783E-07 22.95 6.925E-01 Line Not Found ------

6.497E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30279 Acquisition date 30-MAY-2014 12:43:46 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error AC-228

89. 96 3.40 1.657E+OO ------

Line Not Found ------

93.35 ------

5.60 l.743E+OO ------

Line Not Found ------

99.55 ------

1. 30 l.876E+OO Line Not Found ------

105.36 ------

2.00 1.973E+OO Line Not Found ------

108.99 ------

0. 67 2.021E+OO Line Not Found ------

129.03 ------

2.90 2.163E+OO Line Not Found ------

153.89 ------

0.84 2.160E+OO Line Not Found ------

209.39 4.10

1. 937E+OO Line Not Found ------

216.24 0.80 l.905E+OO Line Not Found ------

270.26 ------

3.80 1.673E+OO ------

Line Not Found ------

328.07 3.50

1. 468E+OO Line Not Found ------

338.42 ------

12.40 1.435E+OO ------

Line Not Found ------

340.94 ------

0.52 1.428E+OO ------

Line Not Found ------

409.62 2.20 1.243E+OO ------

Line Not Found ------

463.10

4. 60 1.125E+OO ------

Line Not Found ------

562.65 ------

1. 01 9.501E-01 ------

Line Not Found ------

581. 52 3.00 9.221E-01 Line Not Found ------

72 6. 63 0.87 7.472E-01 Line Not Found ------

755.28 ------

1. 32 7.197E-01 Line Not Found ------

772. 28

1. 09 7.043E-Ol Line Not Found ------

782.12 0.59 6.956E-01 ------

Line Not Found ------

794.79 ------

4. 60 6.848E-01 ------

Line Not Found ------

830.59 ------

0.63 6.561E-01 Line Not Found ------

835.60

1. 71 6.523E-01 ------

Line Not Found ------

840.44 0.94 6.486E-01 Line Not Found ------

904.29 ------

0.89 6.044E-01 Line Not Found ------

911.16 16 29.00*

6.00lE-01

8. 728E-07 8.766E-07 24.82 964. 64 5.80 5.686E-01 ------

Line Not Found ------

968.97 17.40 5.663E-01 ------

Line Not Found ------

1246.60 ------

0.57 4.593E-01 ------

Line Not Found ------

1459.19 ------

1. 06 4.213E-01 ------

Line Not Found ------

1496.00 ------

1. 05 4.176E-01 Line Not Found ------

1501. 44 0.58 4.172E-01 Line Not Found ------

1580.30 ------

0.71 4.121E-01 Line Not Found ------

1588.23 ------

3.60 4.118E-01 Line Not Found ------

1630.47 ------

1. 95 4.106E-01 Line Not Found ------

1638.10 ------

0.54 4.105E-01 ------

Line Not Found ------

Flag: "*" = Keyline

Minimum Detectable Activity Report Page :

7 Sample ID 30279 Acquisition date 30-MAY-2014 12:43:46 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

2.

477.61 7.6781E-07 MN-54

0.

834.83 3.9031E-08 MN-56

1.

846.81 1.0994E-07 C0-57

8.

122.06 8.2734E-08 C0-58

6.

810.79

1. 9876E-07 C0-60
0.

1332.50 5.7877E-08 SB-124

0.

602.73 2.9197E-08 SB-125

2.

427.88 2.4783E-07 CS-134

1.

604.71 7.0915E-08 CS-137

3.

661.66 l.4556E-07