ML20034D975

From kanterella
Jump to navigation Jump to search
Sy C-HATCH 11-20 - Health Physics Sample Records
ML20034D975
Person / Time
Site: San Onofre  
Issue date: 06/18/2014
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034D975 (5)


Text

Sample ID:

142441 Type: RLSSS Type Detail: SAND

==

Description:==

1405288D 11 STAR 11-20 Dirt Sample lcommonl Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

Origin Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:

.survey No:

Accounting Subcode:

Date: 05/30/14 08:03 Unknown Mat:

NO Mat. SizeNolume:

1586 ml Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00

==

Description:==

STAR 11 SOIL SAMPLE I Collectionl Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

Comments:

COUNT TO MDA RLSSS I Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes ILocaiionl Unit: NON-UNIT RE Stored By:,

Sample Loe:

Other:

Material Loe:

06/18/201411:52 Area: MS Sample Date: 05/29/14 07:10 Sample SizeNolume: 1586 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Elev: 100 Room:

Depth: 3" (in.)

Equip ID:

Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records Sample ID:

142441 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

1405288D 11 STAR 11-20 Dirt Sample Analysis Geometry MCAID Quant.

Units Method FP/AP Lab Analysis By A_ 1 L_marinelli_sand -

30280 1586GR

.000 HENDERSON, JOE C Isotope Mode Activity_

Activity Uncert.

LLD/MDA

%Abund.

Atom. No.

Comments 0

K-40 NT 0.00001053 1.35E-6 r

67.732%

40 0

TL-208 NT 2.251E-7 8.54E-8 r

1.448%

208 0

PB-212 NT 4.418E-7 1.011 E-7 r

2.842%

212 0

Bl-214 NT 4.115E-7 1.059E-7 r

2.647%

214 0

PB-214 NT 4.717E-7 1.842E-7 r

3.034%

214 0

RA-226 NT 2.639E-6 9.87E-7 r

16.975%

226 0

AC-228 NT 6.642E-7 1.792E-7 r

4.272%

228 0

U-235 NT 1.633E-7 6.11E-8 r

1.050%

235 0

BE-7 AP 5.9839E-7

~

0.000%

7 0

MN-54 AP 1.4412E-7

~

0.000%

54 0

MN-56 AP 8.9629E-8

~

0.000%

56 0

C0-57 AP 6.1853E-8

~

0.000%

57 0

C0-58 AP 8.4741E-8

~

0.000%

58 0

C0-60 AP 4.6633E-8 P"

0.000%

60 0

SB-124 AP 7.2542E-8 w

0.000%

124 0

SB-125 FP 2.1641E-7 Iv'"

0.000%

125 0

CS-134 FP 8.2266E-8 w

0.000%

134 0

CS-137 FP 1.4465E-7 P"

0.000%

137 I A11a.lysis Review I Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Comments:

06/18/201411:52 Rad Mat Present:

Yes Rasterized: r Date Mod ID Mod Date 05/30/14 12:58 Mod Id Mod Date Date: 06/10/14 09:55 Page 2 of 3

Health Physics Sample Records Sample ID:

142441 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140528BD 11 STAR 11-20 Dirt Sample I Review!Ap-prove I HP Review Reviewed: COOPER, TERRY L Date: 06/10/14 09:56 Comments: U-235 is likely mis-lD'd from Ac-228 and Rn-226 peaks Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/2014 11 :52 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/14 09:57 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 30-MAY-2014 12:48

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140528BD 11 STAR 11-20 DIRT SAMPLE

  • ID
  • Start Time:
  • Stop Time:
  • Quantity 30280 30-MAY--2014 12: 45: 00 30-MAY-2014 12:45:00
1. 58600E+03 GR Acquisition date: 30-MAY-2014 12:45:07 *
  • Geometry A lL marinelli sand 1 Operator: JOE Counting System IHPS Sample Number:

Analysis Library HENDERSON U2GSP 142441 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.42 0 00:03:00.46 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 29-MAY-2014 23:37 2.56487E-01 4.99495E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

92.77 30 25 2.19 185.21 181 9 35.1 2.98E+OO AC-228 U-235 1

186.19 21 12

1. 48 372. 25 367 10 37.4 1.08E+OO U-235 RA-226 1

238.66 42 16 1.14 477.29 473 8 22.9 2.95E+OO PB-212 1

241.78 18 8

1. 67 483.54 481 7 38.6 1. 08E+OO PB-214 1

295.00 17 9

1. 78 590.10 586 9 39.0 8.69E-Ol PB-214 1

338.03 15 0

1. 38 67 6. 25 673 6 27.0 l.87E+OO AC-228 1

351.95 24 11

1. 33 704.12 699 9 31.1 5.03E-01 PB-214 1

583.14 16 7

1. 74 1166.98 1163 9 37.9 2.71E+OO TL-208 1

609.45 21 2

1. 27 1219.66 1215 9 25.7 6.lOE-01 BI-214 1

1460.82 63 0

1. 96 2924.35 2919 10 12.9 1.49E+OO K-40

Summary of Nuclide Activity Sample ID : 30280 Acquisition date Page :

2 30-MAY-2014 12:45:07 Total number of lines in spectrum 10 Number of unidentified lines 0

Number of lines tentatively identified by NID 10 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 l.28E+09Y

1. 00 1.053E-05 l.053E-05 0.135E-05 12.85 A

TL-208 3.05M

1. 42 l.587E-07 2.251E-07 0.854E-07 37.91 A

PB-212 10.64H

1. 00 4.410E-07 4.418E-07
1. OllE-07 22.88 A

BI-214 19.90M

1. 06 3.890E-07 4.115E-07 l.059E-07 25.74 A

PB-214 26.80M

1. 04 4.524E-07
4. 71 7E-07
1. 842E*-07 39.05 A

RA-226 1600.00Y

1. 00 2.639E-06 2.639E-06 0.987E-06 37.40 A

AC-228 6.13H

1. 00 6.621E-07 6.642E-07 l.792E-07 26.98 KA U-235 7.04E+08Y
1. 00 1.633E-07 l.633E-07
0. 611E-07 37.40 A

Total Activity 1.544E-05 l.555E-05 Grand Total Activity :

1.544E-05 1.555E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit