o

~

"#

  • LICENSEE EVENT REPORT (PLE ASE PRINT OR TYPE ALL REQUtaED INFORMATIONI C0f4 TnOL OLOCK: l e

l l l l l d

lh I'd} [r l N l S l N l p l 1 fh!O !O l~ ! 0LICENSE { 0 lNUMUEH0 { 0 l 0 l - I O25 l 026l@lLICENSE 4 l1 Tl1YP4!1JO l1 l@[

l S i C a t St-l@

^

le 1S is 9 LiCENufLUUL .

'(J'J' f 3l,,ncl l 1. @l 0 I 5 1010 l0 13 12 17 @l o fEvfNTOATE 2 l 1 l 6 I 811 @l nl sitPca , I ,TIdA, TIE g 11 l@

d-] 4 w 6e C oCuti Nuvnt;** 4 63 74 is so rvrNr utsenirr:ON AND rnOOA3LC CONSEQUENCES h I hnel honn vr mnvorf

$ l *] l Oii 6-29-81 it wan (11scove re<l that a nine hanur. 1-067-ERCW-042-2 l

yI from t he 2" ERCW l ine to the lA pipe chase cooler but had not been reinstalled. The the lina l K ] I hanner had been removed to perform a modification to install a spool niece in The event is reportable under 6.9.1.13.c of Sequovah l

] Ll'or the ERCW corrosion studv.

[

B l Unit i Technical Specifications. There was no effect upon public health or safety.

l

]l Previous Occurrences - None.

l TTT! I 80 Coup. valve sys . E u C.* U S E CAUSF SUSCOME COM'ONENT COOE SUSCODE SU8COOE COOE COOF ri q d

Iw I el @ I d @ Lc_l @ l s In 1 9 in in im l@ Ld@ 'tz J @

9 10 ts 12 13 18 39 2 43 M /sstON SEOUE N f f AL OCCUfl AE NCE REPORT 400E TYPE N O.

_EvrNf vtan A E pon T NO.

I-l O,"Ltnino  ;."lg;',', I8 II I 22 l-1 23 101712j 24 26

[gj 21

[0 ~ 13 I 2 01 23 b_J 30 39 LO_l 32

._18 wnO 4 PniVE Coup, COMPONFNT 5Huf00wn A TT ACHUE N T MANUSACTURER AC rtnN suvunt rssfCf SU8Mef f EO n m . 3. SUPP(t E A Or rL ANT METHou HOUnS T M E '8 ACflON Lxi@  ! cIoI oIo aoI laJ@ Lsj@ U.J@ lv la la la i LtJ@LzJ@

33 J4 LzJO JS J6 Ji et 42 43 44 47 CAu:;t ot:;cnlPTIOfJ AfJD COnnCGeVE ACTIONS h ,

f l It l*l l The conuizant engineer f ailed tc, have the hancer reinstalled after comnietion of tha _

~

I l consider reinstallation of the hanger a RBl spool piece installation since he did not The hancer was reinstalled on 6 - 311 - 8 1 . The enenienne oncinnor knn haan

{ii/l l priority item.

1 ns soon as n o n s i b'l o .  !

1 i J il l instructed on the imoortar te of reinstalline 511 connonents

[1 e 4

I[ 80

'l L *}

l r u uit ,

  • f a t 's . %rowEn Of utn 57ATus

] ME fund OF OisCOvtav OiSCOVEnV OESCntPTt0N ..

lBlhl i 3 lClh l0!0l0lhl NA ( OA Observation AL it*/t t y CO f risi LOCATION OF RELE ASE H6 i E A%f n or 688.lf Cr AMOUNT OF ACTIVITY j NA f'I"IlZj@ W @[

'7 al 1 to i NA 44

( l 45 60 PT tt'.rpsN g i r w ro .i m t 0 est e.*n r n t vet ()# ;r nicit ON -

I 0l0 NA 80 u 9 g3 it .iine I

rr n .oN..

tit sunt et nr gr reisteON 41 I

l NA

!91 e 't tl [ 0 l 0 Jl 33 i; 80

[8 t

LOSS (W OR Oau Ar;E f O F ACILITY O

) twr O E LCole riO*4 l

M lZl@l NA

""C * * '

e..uft O h7 lIllIIlIIIIIl i'

dej a 9 Whl(YCnie ION @to NA PDR l ss 89 .

-o Name of Preparer: Clenn B. Kirk / Mike R. Harding Phone: (615) 842-8317

[ i