LER 80-033/01T-0:on 801014,ultrasonic Insp Per IE Bulletin 80-7 Revealed Crack in Jet Pump 8 Holddown Beam at Mean Diameter of Bolt Thread.Caused by Intergranular Stress Corrosion.Beam Replaced W/One of Higher Strength
ML19339A594
Person / Time
Site: Vermont Yankee Entergy icon.png
Issue date: 10/28/1980
From: Murphy W
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19339A591 List:
References
IEB-80-07, IEB-80-7, LER-80-033-01T, LER-80-33-1T, NUDOCS 8011040381
Download: ML19339A594 (1)


Text

..

NIE #

386 U. S. NUCLEAR REGULATORY COMMisslON (7 "7 LICENSEE EVENT REPORT LER 80-33/lT l

, CONTROL 8 LOCK: l l l l l l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) a foTil8 I9 v i TUCENSEE 7

l v I CODE Y l s I l l@l 14 15 010 l-l 010101010uCENSE NUMBER l- 10 l 0 @l411111111l@l 21i 28 uCENSE TYPE Jo l

67 CAT se l@

CON'T M 8 s$RC60l L l@l 0 l 5 lDOCKET 0 l 0NUM8ER l 0 l 2 l 711 @l 80 1 lEVENT 0 l1DATE l418 l 074 l@l1 75 l0REPORT l 2 lDATE 8 l 8 l080l@

i St 68 EVENT DESCRIPTION AND PROSABLE CONSEQUENCES h j lo I2l l U.T. examination (in accordance with NRC Bulletin 80-7 and approved inservice inspec- l l lTTT1 l tion procedure) revealed a crack in the #8 jet pump hold-down beam at the mean dia- l l

l014IImeter of the bolt thread. .-The crack had not led to failure of the hold-down beam. l l 0 l s t l There were no adverse conac c ences to public health and safety. i l

WI l  ;

Io I7I I l l 101811 I

, 7 8 9 80 E OCE SUSCO E COMPONENT CODE SUS ODE SU E

loist l Cl B lO LEj@ l D l@ lP lU lM lP lX lX l@ [j]@ l Z l @

7 8 9 to 11 12 13 18 19 20

,,,, SEQUENTIAL OCCUR R ENCE REPORT REvtsiON

gg 40 EVENT YEAR REPORY NO. COOE TYPE No.

h y(uggas l-l l 0 13 l 3 l l/l l0l1l lTl l-l l 0l l21 8l22 01 23 24 26 27 28 29 30 38 32 l N AC ON O PLANT ME HOURS 22 38 11 FOR S. $U LE VA UFA RER lCl@lXl@

33 34 lZl@

35 l Z [@ 31l0 l0 l0 l0 40l 38

{g 41 lY lg lN l@ lG l0 l8 l0 l@

42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h I i l o 1 l Tha mcst orobable cause of the #8 hold-down beam crack, was intergranular stress cor- I l

l f

W lrosion. U. T. inspect 10n of the other 19 hold-down beams showed no indications. The I i1 12i l #8 hold-down beam (BWR 3 design) was replaced with a higher strength hold-dc,m beam I ,

Iilal l (BWR 4 design). l  !

11 141 I l 7 8 9 80

$  % POWER oTHER STATUS OIS RY Of SCOVERY DESCRIPT1oM

I i i s l l Hl@ l 0 l 0 l 0 l@l NA l lBl@l Ultrasonic Examination l l AbvlTY CO TENT RELEASE AMoyNT OF ACTIVITY LOCATION OF RELEASE l' i i s' *t L_z1' @D CF RELEASEIzl@l" NA I I NA I

PERSON ~E1 Ex,os3Es NuM8ER TvPE DEsCRi,riON@

l 1 l 7 l l Ol Ol 0l@l Zl@l NA l

,ERso~NEL%uks

  • NUM8ER DESCR* TION

.! fiTa18 9101 0l Ol@l12 NA l l 7 11 80 '

LOSS TYPE OF OR DAMACE To FACILITY Q DESCRIPTION N,/

NA L'_L9.)

7 8 9 I zl@lto l 30 i tssyg DE CRIPTION

  • l 12iolLy_181 8 0110 4- 0 9/ NA i 1. i i i i i i i i i i i l i 7 8 9 10 68 69 80 3 NAME OF PREPARER Warren P. Murphy PHONE:

~

--