ML19275A432

From kanterella
Jump to navigation Jump to search

Notifies That Util Response to NRC Acceptably Resolves Issue Re Potential for Reactor Cavity Annulus Seal Ring to Become Destructive Missile During LOCA
ML19275A432
Person / Time
Site: Millstone 
Issue date: 09/11/1979
From: Reid R
Office of Nuclear Reactor Regulation
To: Counsil W
NORTHEAST NUCLEAR ENERGY CO.
References
TAC-11846, TAC-30179, NUDOCS 7910040398
Download: ML19275A432 (2)


Text

. _ s g.

f[ganacg'A, UNITED STATES NUCLEAR REGULATORY COMMISSION y

'c g

'C WASHINGTON, D. C. 20555 11,1979[g(

un)

.)I

,[

E September Docket No. 50-336 Mr. W. G. Counsil, Vice President Nuclear Engineering & Operations Northeast Nuclear Energy Company P. O. Box 270 Hartford, Connecticut 06101

Dear Mr. Counsil:

RE: REACTOR CAVITY SEAL RING GENERIC ISSUE (PWR)

We have completed our review of your response to our letter of February 2, 1978, in regard to the potential for the reactor cavity annulus seal ring to become a destructive missile in the event of a loss-of-coolant accident pipe break inside the reactor cavity.

Your response acceptably resolves this issue for Millstone Nuclear Power Station, Unit No. 2.

Sincerely,

~

w' Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors cc: See next page

~

O e

1095

~

7 910040 9 Y h

Northeast Nuclear Energy Company cc:

William H. Cuddy, Esquire Day, Berry & Howard Counselors at Law One Constitution Pla:a Hartford, Connecticut 06103 Waterford Public Library Rope Ferry Road, Route 156 Waterford, Connecticut 06385 Northeast Nuclear Energy Company ATTN:

Superintendent Millstone Plant Post Office Box 128 llaterford, Connecticut 06385 Northeast Utilities Service Company ATTN: Mr. James R. Himmelwright Nuclear Engineering and Operations P'. O. Box 270 Hartford, Connecticut 06101 Anthony Z. Roisman, Esq.

Natural Resources Defense Council 917 15th Street, N.W.

Washington, D.C.

20005 Mr. John T. Shediosky Nuclear Regulatcry Commission, Region I Office of Inspe: tion and Enforcement 631 Park Avenue King of Prussia, Pennsylvania 19406

~

1095

~3 b

m._..